Three-dimensional surface presentation of optic nerve head from SPECTRALIS OCT images: observing glaucoma patients

verfasst von: Abdel-Razzak M. Al-hinnawi, Arqam M. Alqasem, Bassam O. Al-Naami

Erschienen in: International Ophthalmology | Ausgabe 9/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To propose an innovative three-dimensional surface presentation of the optic nerve head (ONH) from the SPECTRALIS optical coherence tomography (OCT) device.

Method

A dataset of OCT ONH files from eight glaucoma follow-up patients was obtained. The set consisted of OCT ONH images for 20 right eyes (OD) and 17 left eyes (OS). Preprocessing steps followed with OCT reconstruction procedures were designed. The three-dimensional (3D) surface rendering was generated for all OCT ONH images. A set of eight International Organization for Standardization (ISO) roughness parameters were calculated to assess the disparities in the 3D ONH surface morphology during follow-up visit.

Results

The 3D ONH surface presents a new OCT display to ophthalmology; so, the physician can examine the surface morphology of the OCT ONH region. The 3D ONH surface’s shape varied noticeably during follow-up visits in glaucoma patients. The percentage disparity of ONH surface roughness’s can be as small as 3% or almost zero, but it can be as large as 56% or 100%.

Conclusions

The approximation of OCT ONH 3D surface is feasible; it may possibly be beneficial to ophthalmology. It allows ophthalmologist to perceive the entire changes in the ONH surface morphology during the follow-up attendances; so, it can be used to observe patient health. The ISO roughness measurements are suggestive complementary factors to observe the alterations in the OCT ONH region.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Frecher AF, Mengedoht K, Werner W (1988) Eye-length measurement by interferometry with partially coherent light. Opt Lett 13(3):186–188CrossRef Frecher AF, Mengedoht K, Werner W (1988) Eye-length measurement by interferometry with partially coherent light. Opt Lett 13(3):186–188CrossRef
2.
Zurück zum Zitat Huang D, Swanson EA, Lin CP, Schuman JS, Stinson WG, Chang W, Hee MR, Flotte T, Gregory K, Puliafito CA, Fujimoto JG (1991) Opt Coherence Tomogr. Science 254(5035):1178–1181CrossRefPubMedPubMedCentral Huang D, Swanson EA, Lin CP, Schuman JS, Stinson WG, Chang W, Hee MR, Flotte T, Gregory K, Puliafito CA, Fujimoto JG (1991) Opt Coherence Tomogr. Science 254(5035):1178–1181CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Gelikonov VM, Gelikonov GV, Dolin LS, Kamensky VA, Sergeev AM, Shakhova NM, Galdkova ND, Zagaynova EV (2003) Optical coherence tomography: physical principles and applications. Laser Phys 13:692–702 Gelikonov VM, Gelikonov GV, Dolin LS, Kamensky VA, Sergeev AM, Shakhova NM, Galdkova ND, Zagaynova EV (2003) Optical coherence tomography: physical principles and applications. Laser Phys 13:692–702
4.
Zurück zum Zitat Gabriele ML, Wollstein G, Ishikawa H, Kagemann L, Xu J, Folio LS, Schuman JS (2011) Optical coherence tomography: history, current status, and laboratory work. Investig Ophthalmol Vis Sci 52(5):2425–2436CrossRef Gabriele ML, Wollstein G, Ishikawa H, Kagemann L, Xu J, Folio LS, Schuman JS (2011) Optical coherence tomography: history, current status, and laboratory work. Investig Ophthalmol Vis Sci 52(5):2425–2436CrossRef
5.
Zurück zum Zitat Bussel II, Wollstein G, Schuman JS (2014) OCT for glaucoma diagnosis, screening, and detection of glaucoma progression. Br J Ophthalmol 98(Supplement):ii15–ii19CrossRefPubMed Bussel II, Wollstein G, Schuman JS (2014) OCT for glaucoma diagnosis, screening, and detection of glaucoma progression. Br J Ophthalmol 98(Supplement):ii15–ii19CrossRefPubMed
6.
Zurück zum Zitat Töteberg-Harms M, Sturm V, Knecht PB, Funk J, Menke MN (2012) Repeatability of nerve fiber layer thickness measurements in patients with glaucoma and without glaucoma using spectral-domain and time-domain OCT. Graefes Arch Clin Exp Ophthalmol 250:279–287CrossRefPubMed Töteberg-Harms M, Sturm V, Knecht PB, Funk J, Menke MN (2012) Repeatability of nerve fiber layer thickness measurements in patients with glaucoma and without glaucoma using spectral-domain and time-domain OCT. Graefes Arch Clin Exp Ophthalmol 250:279–287CrossRefPubMed
7.
Zurück zum Zitat Firat PG, Doganay S, Demirel EE, Colak C (2013) Comparison of ganglion cell and retinal nerve fiber layer thickness in primary open-angle glaucoma and normal tension glaucoma with spectral-domain OCT. Graefes Arch Clin Exp Ophthalmol 251:831–838CrossRefPubMed Firat PG, Doganay S, Demirel EE, Colak C (2013) Comparison of ganglion cell and retinal nerve fiber layer thickness in primary open-angle glaucoma and normal tension glaucoma with spectral-domain OCT. Graefes Arch Clin Exp Ophthalmol 251:831–838CrossRefPubMed
8.
Zurück zum Zitat Savini G, Carbonelli M, Parisi V, Barboni P (2011) Repeatability of optic nerve head parameters measured by spectral-domain OCT in healthy eyes. Ophthalmic Surg Lasers Imaging 42:209–215CrossRefPubMed Savini G, Carbonelli M, Parisi V, Barboni P (2011) Repeatability of optic nerve head parameters measured by spectral-domain OCT in healthy eyes. Ophthalmic Surg Lasers Imaging 42:209–215CrossRefPubMed
9.
Zurück zum Zitat Al-Hinnawi AM, Al-Naami BO, Al-Latayfeh MM (2017) Optic nerve head slope-based quantitative parameters for identifying open-angle glaucoma on SPECTRALIS OCT images. Int Ophthalmol 37:979–988CrossRefPubMed Al-Hinnawi AM, Al-Naami BO, Al-Latayfeh MM (2017) Optic nerve head slope-based quantitative parameters for identifying open-angle glaucoma on SPECTRALIS OCT images. Int Ophthalmol 37:979–988CrossRefPubMed
10.
Zurück zum Zitat Aref AA, Budenz DL (2010) Spectral Domain optical coherence tomography in the diagnosis and management of glaucoma. Ophthalmic Surg Lasers Imaging 41(Suppl.):S15–S27CrossRefPubMed Aref AA, Budenz DL (2010) Spectral Domain optical coherence tomography in the diagnosis and management of glaucoma. Ophthalmic Surg Lasers Imaging 41(Suppl.):S15–S27CrossRefPubMed
11.
Zurück zum Zitat Litjens G, Kooi T, Babak Bejnordi E, Setio AA, Ciompi F, Ghafoorian M, van der Laak JAWM, Ginneken B, Sánchez CI (2017) A survey on deep learning in medical image analysis. Med Image Anal 42:60–88CrossRef Litjens G, Kooi T, Babak Bejnordi E, Setio AA, Ciompi F, Ghafoorian M, van der Laak JAWM, Ginneken B, Sánchez CI (2017) A survey on deep learning in medical image analysis. Med Image Anal 42:60–88CrossRef
12.
Zurück zum Zitat Wang B, Wollstein G, Schuman JS (2016) Optic nerve: optical coherence tomography. Pearls of Glaucoma Management. Springer, Berlin, pp 51–61CrossRef Wang B, Wollstein G, Schuman JS (2016) Optic nerve: optical coherence tomography. Pearls of Glaucoma Management. Springer, Berlin, pp 51–61CrossRef
14.
Zurück zum Zitat Shoji T, Kuroda H, Suzuki M, Baba M, Araie M, Yoneya S (2015) Three-dimensional optic nerve head images using optical coherence tomography with a broad bandwidth, femtosecond, and mode-locked laser. Graefes Arch Clin Exp Ophthalmol 253:313–321CrossRefPubMed Shoji T, Kuroda H, Suzuki M, Baba M, Araie M, Yoneya S (2015) Three-dimensional optic nerve head images using optical coherence tomography with a broad bandwidth, femtosecond, and mode-locked laser. Graefes Arch Clin Exp Ophthalmol 253:313–321CrossRefPubMed
15.
Zurück zum Zitat Kagemann L, Isikawa H, Wollstein G, Gabriele M, Schuman JS (2009) Visualization of 3D high speed ultrahigh resolution optical coherence tomographic data identifies structures visible in 2D frames. Opt Express 17(5):4208–4220CrossRefPubMedPubMedCentral Kagemann L, Isikawa H, Wollstein G, Gabriele M, Schuman JS (2009) Visualization of 3D high speed ultrahigh resolution optical coherence tomographic data identifies structures visible in 2D frames. Opt Express 17(5):4208–4220CrossRefPubMedPubMedCentral
16.
17.
Zurück zum Zitat ISO 4287:2000 Geometrical product specification (GPS)—Surface texture. Profile method. Terms, definitions and surface texture parameters ISO 4287:2000 Geometrical product specification (GPS)—Surface texture. Profile method. Terms, definitions and surface texture parameters
18.
Zurück zum Zitat ISO 25178-2:2012 Geometrical product specifications (GPS) - Surface texture: areal - Part 2: terms, definitions and surface texture parameters ISO 25178-2:2012 Geometrical product specifications (GPS) - Surface texture: areal - Part 2: terms, definitions and surface texture parameters
19.
Zurück zum Zitat Yousefi S, Goldbaum MH, Balasubramanian M, Jung T, Weinreb RN, Medeiros FA, Zangwill LM, Liebmann JM, Girkin CA, Bowd C (2013) Glaucoma progression detection using structural retinal nerve fiber layer measurements and functional visual field points. IEEE Trans Biomed Eng 00:1–12 Yousefi S, Goldbaum MH, Balasubramanian M, Jung T, Weinreb RN, Medeiros FA, Zangwill LM, Liebmann JM, Girkin CA, Bowd C (2013) Glaucoma progression detection using structural retinal nerve fiber layer measurements and functional visual field points. IEEE Trans Biomed Eng 00:1–12
Metadaten
Titel
Three-dimensional surface presentation of optic nerve head from SPECTRALIS OCT images: observing glaucoma patients
verfasst von
Abdel-Razzak M. Al-hinnawi
Arqam M. Alqasem
Bassam O. Al-Naami
Publikationsdatum
24.09.2018
Verlag
Springer Netherlands
Erschienen in
International Ophthalmology / Ausgabe 9/2019
Print ISSN: 0165-5701
Elektronische ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-018-1023-y

Weitere Artikel der Ausgabe 9/2019

International Ophthalmology 9/2019 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Open Access 22.02.2024 | Peeling | Originalien

Selektive Vitalfarbstoffe in der Makulachirurgie

Erhöhen sie die Wahrscheinlichkeit der intraoperativen ILM-Identifizierung auch bei einem erfahrenen Operateur?

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.