Skip to main content
Erschienen in: Journal of Orthopaedics and Traumatology 1/2019

Open Access 01.12.2019 | Original article

Tibia plateau fracture mapping and its influence on fracture fixation

verfasst von: Lorcan McGonagle, Tim Cordier, Bjorn C. Link, Mark S. Rickman, Lucian B. Solomon

Erschienen in: Journal of Orthopaedics and Traumatology | Ausgabe 1/2019

Abstract

Background

Tibial plateau fracture classifications are based on anteroposterior radiographs. Precontoured locking plates are commonly used to treat such fractures. The aims of this study are to: (1) describe tibial plateau fracture anatomy in the axial plane and (2) assess whether current plating systems allow screws to be placed suitably.

Materials and methods

A graphical tibial plateau template was developed. One hundred twenty-five tibial plateau fractures (four bilateral) were reviewed (80 men, 41 women; average age 45.5 years, range 21–77.7 years). The axial computed tomography (CT) slice 0.3–0.5 mm below the medial articular surface was reviewed in all cases. Fracture lines were drawn on the template. Four lateral locking plates were placed against a cadaveric adult tibia. Based on the projected screw directions, suitable fracture patterns were identified. Fractures were considered “suitable” if the screws passed 90 ± 22° to the fracture line.

Results

Two hundred sixty-one different fracture lines were identified. One hundred thirty-four fractures involved the lateral plateau; 96 were suitable for lateral plating. Ninety fractures involved the medial plateau, 82 were treatable using the various plate positions on medial-posterior aspect of the medial plateau. Thirty-seven fractures were bicondylar; 20 were treatable with a posteromedial plate.

Conclusions

Tibial plateau fractures follow consistent patterns, with most lateral and medial plateau fracture lines being in the sagittal plane, although there is greater variation medially. Positioning of modern locking plates will deal effectively with 72 % of all lateral plateau fractures and 91 % of medial plateau fractures.

Level of evidence

Level 3.

Introduction

Tibia plateau fractures are common injuries that often require surgical treatment. Most cases occur around the fifth to sixth decades, with men and women affected equally [1, 2]. Challenges with such fractures include gaining anatomical reduction of the articular surface and satisfactory internal fixation, within the constraints of local soft tissues and blood supply. The Schatzker and AO classification systems, commonly used for tibial plateau fractures, are based on anteroposterior radiographs of the knee (i.e., coronal plane) without consideration of fracture anatomy in the axial or sagittal planes [1, 3]. Understanding fracture anatomy is integral to choosing the correct surgical approach for fixation and the correct placement of plate and screws.
Locking plates are widely used for treatment of periarticular fractures, as they provide angular stability and may allow earlier motion and weight bearing, particularly when compared with fracture fixation with nonlocking plates [4, 5]. There has been renewed interest recently in the morphology of tibial plateau fractures, using computed tomography (CT) imaging [6, 7]. However, little is known about whether modern precontoured plates can be satisfactorily placed to deal with such fractures.
The primary aim of this study is to describe the anatomy of tibial plateau fractures in the axial plane. The secondary aim is to determine whether current plating systems are appropriate to deal with these fracture patterns. Appropriate fixation was defined based on biomechanical studies that suggested screws should not be positioned more than 22° from a perpendicular to the fracture line and that locking screws have the best interference strength and stiffness when inserted perpendicular to the plate [8, 9].

Materials and methods

Developing a template

CT scans of 50 knees with no bony pathology were identified from the radiographic database of our institution.
The axial slice for each tibial plateau 0.3–0.5 mm below the joint surface was identified. The maximum anteroposterior (AP) and mediolateral (ML) dimensions of all plateaus were measured. The average AP:ML ratio was 1:1.3, forming the basis of our template. A best-fit line was then drawn based on all the images to reproduce the curved outline of the tibial plateau. All images were viewed as a left tibia. In cases were the right tibia was scanned, the image was flipped horizontally electronically to resemble a left tibia.
This provided us with a graphical template upon which we drew our fractures. Fracture lines were plotted using XY coordinates for the entry and exit points on the cortical surface using a Microsoft Excel 97–2003 worksheet, as described previously by Mandziak [10].

Patients

The inclusion criteria were tibia plateau fractures treated surgically between 2006 and 2014 in patients aged over 18 years, with a fine-cut preoperative CT scan of the injured knee at 0.3–0.5 mm.
Exclusion criteria were fractures treated nonoperatively, isolated tibial tubercle avulsion fractures, isolated anterior cruciate ligament (ACL)/posterior cruciate ligament (PCL) avulsion fractures, patients under 18 years, and in situ metalwork.
One hundred twenty-five tibial plateau fractures (four bilateral) fit the inclusion and exclusion criteria and were included in this study. There were 80 men and 41 women. The average age was 45.5 years (range 21–77.7 years). The mechanism of injury is outlined in Table 1.
Table 1
Mechanism of injury
Mode of injury
Number of cases
Motorbike accident
42
Pedestrian/cyclist versus car
20
Fall from height
19
Fall from standing height
16
Sporting accident
16
Crush injury
12

Image analysis

All patients had a CT scan prior to definitive fixation. The axial CT images were reviewed. Fracture anatomy was drawn out using the tibial plateau grid described above. Emulating the technique used by Cole to configure tibial plafond fractures, we utilized the axial slice 0.3–0.5 mm below the medial articular surface [11]. Only two patients had a spanning external fixator at the time of CT. Fracture lines were drawn as “virtually” reduced fragments as per Molenaars [7], thereby correcting for any fracture displacement, including depressed fractures.
All fracture lines were drawn separately by two of the authors. A subsequent review of all images was carried out by two different authors to ensure agreement and consistency of fracture mapping. This included confirming the coordinates for all fracture lines. Analysis of more distal axial slices as well as reviewing the sagittal and coronal cuts was carried out to confirm the medial/lateral/bicondylar classification of fractures. Disagreement was resolved by consensus.
Postoperative radiographs/CT scans were not reviewed as part of this study.

Cadaveric plate application

Two dried cadaveric adult tibiae (one left, right) with no soft tissue attachments were obtained from the University of Adelaide anatomy department. A selection of modern locking lateral locking plates were obtained:
  • Periarticular proximal tibial locking plate (Zimmer, Warsaw, USA)
  • NCB® proximal tibia system (Zimmer, Warsaw, USA)
  • 3.5-mm LCP proximal tibia plates (Depuy Synthes, West Chester, USA)
  • Tibia PERI-LOC plate (Smith and Nephew, Memphis, USA)
These lateral locking plates were then placed against the cadaveric tibiae as per the respective manufacturer’s technique guide, as shown in Figs. 1, 2. Based on these images, we projected the screw directions as shown by the red arrows in Fig. 1. We then determined which fracture patterns were suitable for treatment with a lateral locking plate. Fractures were deemed suitable for fixation with a lateral plate if the screws would pass 90 ± 22° [8].
Plates on the lateral side are limited in their positioning by the anatomical shape of the plates, whereas on the medial side it is more the surgical approach and soft tissues that limit plate position. As a result of this, the plate position is potentially much more variable medially than on the lateral side, as shown in Fig. 3. Considering the range of possible medial plate positions from direct medial to posteromedial, we used the plates below for analysis.
  • PERI-LOC VL 3.5-mm posteromedial proximal tibia locking plate (Smith and Nephew, Memphis, USA)
  • 3.5-mm LCP posteromedial proximal tibia plate (Depuy Synthes, West Chester, USA)
Variation in possible screw trajectory was taken into account where appropriate.

Results

All fractures

In the 125 patients included in the study, 261 different primary fracture lines were identified, as depicted in Fig. 4.

Lateral plateau fractures

One hundred thirty-four fractures involved the lateral plateau (Fig. 5). Eighty-four of these fractures were suitable for lateral plating.

Medial plateau fractures

Ninety fractures involved the medial plateau (Fig. 6). Sixty-three of these fractures were treatable using the various plate positions on medial-posterior aspect of the medial plateau.

Bicondylar fractures

Thirty-seven fractures were bicondylar (Fig. 7). Such fractures are obviously bicondylar when seen in the coronal plane, whilst the sagittal plane fractures were deemed bicondylar as there was marked metaphyseal comminution (i.e., Schatzker 6 classification) upon reviewing the other CT slices. This comminution prevented medial/lateral classification. Twelve of these fractures were treatable with a posteromedial plate.

Discussion

This study characterizes the axial anatomy of tibia plateau fractures, and shows the applicability of current plating systems. The results for our primary aim show that the most common fracture pattern was a sagittal plane fracture of the lateral plateau, being responsible for just under half of all tibial plateau fractures. Although sagittal plane fracture was also the most common type of fracture involving the medial plateau, the medial side exhibited much greater variation in fracture line orientation.
In a similar CT-based study, Molenaars [7] noted that a lateral split fragment was identified in 75 % of fractures, whilst our study identified that lateral plateau fractures accounted for just over half of all fractures. They also stated that 43 % of their fractures involved a posteromedial fragment, extended from the (antero)medial to the (postero)lateral side of the plateau. Our dataset shows that only 10 % of all fractures and 28 % of medial plateau fractures follow this (antero)medial-(postero) lateral pattern. Patient and mechanism of injury variables between these cohorts could be responsible for these differences.
Luo [6] used axial CT fracture anatomy to describe a “3 column fracture” concept (anterior, medial, posterior). This concept partially matched findings in our bicondylar fractures, although only 12/37 of our bicondylar fractures had a “posterior column” fragment, suggesting that this concept is not universally applicable.
Barei [12] described a posteromedial tibia fragment relative to the posterior femoral condylar axis (PFCA), showing that 74 % of bicondylar fractures include a posteromedial fragment. A similar study by Higgins [13] reported an incidence of 59 % of posteromedial fragments in bicondylar tibia plateau fractures. These two studies described a wide variation in the plane of the posteromedial fracture fragment as described by the major articular fragment angle, which varied from − 87 to + 52° and − 41 to + 23° relative to the PFCA, respectively. This wide variation in the plane of the fracture makes it difficult to predict plate/screw placement consistently.
Thirty-seven patients in our study had bicondylar injuries (including separate medial and lateral plateau fracture lines), although only 18 had a “posteriorly based fracture line of the medial plateau with the fracture line exiting the medial cortex” [13]. Why our bicondylar injury cohort has a lower proportion of posteromedial fragments is unclear, although different definitions of the fragment may be partly responsible.
The results for our secondary aim show that “correct” positioning of lateral locking plates will result in satisfactory positioning of locking screws relative to the fracture line in 71 % of all lateral plateau fractures and 91 % of all medial plateau fractures.
Medial plateau fractures in numerous different planes are treatable as there is wide variation in the potential positioning of the medial locking plates. Lateral locking plate position is relatively fixed. This means that a much narrower range of fracture planes is treatable with these plates.
To the best of our knowledge, no previous study has assessed tibial plateau fracture orientation and plate/screw positioning to the same degree as in this study. However, the importance of placing plates as parallel as possible to fracture lines has been demonstrated by Weaver [14]. Their series on condylar fractures showed that lateral plating alone was effective in maintaining reduction in medial fracture lines in the sagittal plane, but not medial fracture lines in the coronal plane. Those coronal plane medial fractures treated with dual plating had significantly less loss of reduction than isolated lateral plating. These findings are supported by Gosling 2005, who noted that a single lateral Less Invasive Stabilization System (LISS) plate was associated with a secondary loss of reduction in 14 % of complete articular fractures, although crucially this study excluded cases which also had a medial plate [15].
The importance of isolated lateral locking plate versus dual plating has been assessed biomechanically with some variations in results, suggesting that dual plating may not be that important. However, none of these fracture models that used a medial plate had screws that crossed a medial articular fracture at 90°, nor did any of them recreate the posteromedial fracture in the coronal plane [16, 17]. However, Zeng [18] showed that cortical screws via a posterior T-shaped buttress plate allowed the least subsidence of the posteromedial fragment when compared with anteroposterior lag screws, an anteromedial limited contact dynamic compression plate (LC-DCP), a lateral locking plate.
This study has a number of limitations. Firstly, all fractures are drawn as straight lines based only on their entry and exit coordinates. In reality, many were curved or “S” shaped. Secondly, only fracture patterns in the axial plane were considered. Fracture patterns in the sagittal and coronal planes also need to be taken into account when making a preoperative plan. Thirdly, we considered locking screws passing at 90 ± 22° to the fracture line as acceptable [8]. Further research on how much the locking screw angle across fracture fragments affects stability is needed.
Note that not every fracture line needs to be treated with a separate plate/screw construct. Fracture lines that are parallel or nearly parallel can be managed with the same plate/screw construct.
In conclusion, tibial plateau fractures follow consistent patterns, with most lateral and medial plateau fracture lines being in the sagittal plane, although there is greater variation medially.
Positioning of modern locking plates will deal effectively with 72 % of all lateral plateau fractures and 91 % of medial plateau fractures.
Careful analysis of preoperative CT scans, especially in the presence of medial fractures, is required in order to formulate an appropriate surgical plan using currently available locking plate technology.

Authors’ contributions

L.M.: data collection, write up, editing. T.C.: template development, data collection, editing. B.C.L.: data collection, editing. M.S.R.: methodology, editing. L.B.S.: initial idea, template development, editing. All authors read and approved the final manuscript.

Acknowledgements

Not applicable.

Competing interests

L.B.S. has received research grants from NHMRC and Zimmer, plus payment for lectures including service on speakers bureaus from AO Trauma and OTC. M.S.R: has received research grants from Depuy and Smith & Nephew, and has worked in a consultancy role with Adler Orthopaedics.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
Not applicable.
Ethical approval was not sought as computed tomography was already performed as part of patient care. No identifiable patient data are presented. Data were analyzed retrospectively.

Funding

Not applicable.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
Literatur
1.
Zurück zum Zitat Schatzker J, McBroom R, Bruce D (1979) The tibial plateau fracture. The Toronto experience 1968–1975. Clin Orthop Relat Res 138:94–104 Schatzker J, McBroom R, Bruce D (1979) The tibial plateau fracture. The Toronto experience 1968–1975. Clin Orthop Relat Res 138:94–104
2.
Zurück zum Zitat Wasserstein D, Henry P, Paterson JM, Kreder HJ, Jenkinson R (2014) Risk of total knee arthroplasty after operatively treated tibial plateau fracture: a matched-population-based cohort study. J Bone Joint Surg Am 96(2):144–150CrossRef Wasserstein D, Henry P, Paterson JM, Kreder HJ, Jenkinson R (2014) Risk of total knee arthroplasty after operatively treated tibial plateau fracture: a matched-population-based cohort study. J Bone Joint Surg Am 96(2):144–150CrossRef
3.
Zurück zum Zitat Marsh JL, Slongo TF, Agel J, Broderick JS, Creevey W, DeCoster TA et al (2007) Fracture and dislocation classification compendium—2007: Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 21(10 Suppl):S1–S133CrossRef Marsh JL, Slongo TF, Agel J, Broderick JS, Creevey W, DeCoster TA et al (2007) Fracture and dislocation classification compendium—2007: Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 21(10 Suppl):S1–S133CrossRef
4.
Zurück zum Zitat Ozkaya U, Parmaksizoglu AS (2015) Dual locked plating of unstable bicondylar tibial plateau fractures. Injury 46(Suppl 2):S9–S13CrossRef Ozkaya U, Parmaksizoglu AS (2015) Dual locked plating of unstable bicondylar tibial plateau fractures. Injury 46(Suppl 2):S9–S13CrossRef
5.
Zurück zum Zitat Van de Pol GJ, Iselin LD, Callary SA, Thewlis D, Jones CF, Atkins GJ et al (2015) Impaction bone grafting has potential as an adjunct to the surgical stabilisation of osteoporotic tibial plateau fractures: early results of a case series. Injury 46(6):1089–1096CrossRef Van de Pol GJ, Iselin LD, Callary SA, Thewlis D, Jones CF, Atkins GJ et al (2015) Impaction bone grafting has potential as an adjunct to the surgical stabilisation of osteoporotic tibial plateau fractures: early results of a case series. Injury 46(6):1089–1096CrossRef
6.
Zurück zum Zitat Luo C-F, Sun H, Zhang B, Zeng B-F (2010) Three-column fixation for complex tibial plateau fractures. J Orthop Trauma 24(11):683–692CrossRef Luo C-F, Sun H, Zhang B, Zeng B-F (2010) Three-column fixation for complex tibial plateau fractures. J Orthop Trauma 24(11):683–692CrossRef
7.
Zurück zum Zitat Molenaars RJ, Mellema JJ, Doornberg JN, Kloen P (2015) Tibial plateau fracture characteristics: computed tomography mapping of lateral, medial, and bicondylar fractures. J Bone Joint Surg Am 97(18):1512–1520CrossRef Molenaars RJ, Mellema JJ, Doornberg JN, Kloen P (2015) Tibial plateau fracture characteristics: computed tomography mapping of lateral, medial, and bicondylar fractures. J Bone Joint Surg Am 97(18):1512–1520CrossRef
8.
Zurück zum Zitat Johner R, Joerger K, Cordey J, Perren SM (1983) Rigidity of pure lag-screw fixation as a function of screw inclination in an in vitro spiral osteotomy. Clin Orthop Relat Res 178:74–79 Johner R, Joerger K, Cordey J, Perren SM (1983) Rigidity of pure lag-screw fixation as a function of screw inclination in an in vitro spiral osteotomy. Clin Orthop Relat Res 178:74–79
9.
Zurück zum Zitat Kääb MJ, Frenk A, Schmeling A, Schaser K, Schütz M, Haas NP (2004) Locked internal fixator: sensitivity of screw/plate stability to the correct insertion angle of the screw. J Orthop Trauma 18(8):483–487CrossRef Kääb MJ, Frenk A, Schmeling A, Schaser K, Schütz M, Haas NP (2004) Locked internal fixator: sensitivity of screw/plate stability to the correct insertion angle of the screw. J Orthop Trauma 18(8):483–487CrossRef
10.
Zurück zum Zitat Mandziak DG, Watts AC, Bain GI (2011) Ligament contribution to patterns of articular fractures of the distal radius. J Hand Surg Am 36(10):1621–1625CrossRef Mandziak DG, Watts AC, Bain GI (2011) Ligament contribution to patterns of articular fractures of the distal radius. J Hand Surg Am 36(10):1621–1625CrossRef
11.
Zurück zum Zitat Cole PA, Mehrle RK, Bhandari M, Zlowodzki M (2013) The pilon map: fracture lines and comminution zones in OTA/AO type 43C3 pilon fractures. J Orthop Trauma 27(7):e152–e156CrossRef Cole PA, Mehrle RK, Bhandari M, Zlowodzki M (2013) The pilon map: fracture lines and comminution zones in OTA/AO type 43C3 pilon fractures. J Orthop Trauma 27(7):e152–e156CrossRef
12.
Zurück zum Zitat Barei DP, O’Mara TJ, Taitsman LA, Dunbar RP, Nork SE (2008) Frequency and fracture morphology of the posteromedial fragment in bicondylar tibial plateau fracture patterns. J Orthop Trauma 22(3):176–182CrossRef Barei DP, O’Mara TJ, Taitsman LA, Dunbar RP, Nork SE (2008) Frequency and fracture morphology of the posteromedial fragment in bicondylar tibial plateau fracture patterns. J Orthop Trauma 22(3):176–182CrossRef
13.
Zurück zum Zitat Higgins TF, Kemper D, Klatt J (2009) Incidence and morphology of the posteromedial fragment in bicondylar tibial plateau fractures. J Orthop Trauma 23(1):45–51CrossRef Higgins TF, Kemper D, Klatt J (2009) Incidence and morphology of the posteromedial fragment in bicondylar tibial plateau fractures. J Orthop Trauma 23(1):45–51CrossRef
14.
Zurück zum Zitat Weaver MJ, Harris MB, Strom AC, Smith RM, Lhowe D, Zurakowski D et al (2012) Fracture pattern and fixation type related to loss of reduction in bicondylar tibial plateau fractures. Injury 43(6):864–869CrossRef Weaver MJ, Harris MB, Strom AC, Smith RM, Lhowe D, Zurakowski D et al (2012) Fracture pattern and fixation type related to loss of reduction in bicondylar tibial plateau fractures. Injury 43(6):864–869CrossRef
15.
Zurück zum Zitat Gosling T, Schandelmaier P, Muller M, Hankemeier S, Wagner M, Krettek C (2005) Single lateral locked screw plating of bicondylar tibial plateau fractures. Clin Orthop Relat Res 439:207–214CrossRef Gosling T, Schandelmaier P, Muller M, Hankemeier S, Wagner M, Krettek C (2005) Single lateral locked screw plating of bicondylar tibial plateau fractures. Clin Orthop Relat Res 439:207–214CrossRef
16.
Zurück zum Zitat Mueller KL, Karunakar MA, Frankenburg EP, Scott DS (2003) Bicondylar tibial plateau fractures: a biomechanical study. Clin Orthop Relat Res 412:189–195CrossRef Mueller KL, Karunakar MA, Frankenburg EP, Scott DS (2003) Bicondylar tibial plateau fractures: a biomechanical study. Clin Orthop Relat Res 412:189–195CrossRef
17.
Zurück zum Zitat Gösling T, Schandelmaier P, Marti A, Hufner T, Partenheimer A, Krettek C (2004) Less invasive stabilization of complex tibial plateau fractures: a biomechanical evaluation of a unilateral locked screw plate and double plating. J Orthop Trauma 18(8):546–551CrossRef Gösling T, Schandelmaier P, Marti A, Hufner T, Partenheimer A, Krettek C (2004) Less invasive stabilization of complex tibial plateau fractures: a biomechanical evaluation of a unilateral locked screw plate and double plating. J Orthop Trauma 18(8):546–551CrossRef
18.
Zurück zum Zitat Zeng Z-M, Luo C-F, Putnis S, Zeng B-F (2011) Biomechanical analysis of posteromedial tibial plateau split fracture fixation. Knee 18(1):51–54CrossRef Zeng Z-M, Luo C-F, Putnis S, Zeng B-F (2011) Biomechanical analysis of posteromedial tibial plateau split fracture fixation. Knee 18(1):51–54CrossRef
Metadaten
Titel
Tibia plateau fracture mapping and its influence on fracture fixation
verfasst von
Lorcan McGonagle
Tim Cordier
Bjorn C. Link
Mark S. Rickman
Lucian B. Solomon
Publikationsdatum
01.12.2019
Verlag
Springer International Publishing
Erschienen in
Journal of Orthopaedics and Traumatology / Ausgabe 1/2019
Print ISSN: 1590-9921
Elektronische ISSN: 1590-9999
DOI
https://doi.org/10.1186/s10195-019-0519-1

Weitere Artikel der Ausgabe 1/2019

Journal of Orthopaedics and Traumatology 1/2019 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.