Skip to main content
Erschienen in: European Radiology 8/2019

Open Access 14.12.2018 | Experimental

Time-series hyperpolarized xenon-129 MRI of lobar lung ventilation of COPD in comparison to V/Q-SPECT/CT and CT

verfasst von: Ozkan Doganay, Tahreema Matin, Mitchell Chen, Minsuok Kim, Anthony McIntyre, Daniel R. McGowan, Kevin M. Bradley, Thomas Povey, Fergus V. Gleeson

Erschienen in: European Radiology | Ausgabe 8/2019

Abstract

Purpose

To derive lobar ventilation in patients with chronic obstructive pulmonary disease (COPD) using a rapid time-series hyperpolarized xenon-129 (HPX) magnetic resonance imaging (MRI) technique and compare this to ventilation/perfusion single-photon emission computed tomography (V/Q-SPECT), correlating the results with high-resolution computed tomography (CT) and pulmonary function tests (PFTs).

Materials and methods

Twelve COPD subjects (GOLD stages I–IV) participated in this study and underwent HPX-MRI, V/Q-SPECT/CT, high-resolution CT, and PFTs. HPX-MRI was performed using a novel time-series spiral k-space sampling approach. Relative percentage ventilations were calculated for individual lobe for comparison to the relative SPECT lobar ventilation and perfusion. The absolute HPX-MRI percentage ventilation in each lobe was compared to the absolute CT percentage emphysema score calculated using a signal threshold method. Pearson’s correlation and linear regression tests were performed to compare each imaging modality.

Results

Strong correlations were found between the relative lobar percentage ventilation with HPX-MRI and percentage ventilation SPECT (r = 0.644; p < 0.001) and percentage perfusion SPECT (r = 0.767; p < 0.001). The absolute CT percentage emphysema and HPX percentage ventilation correlation was also statistically significant (r = 0.695, p < 0.001). The whole lung HPX percentage ventilation correlated with the PFT measurements (FEV1 with r = − 0.886, p < 0.001*, and FEV1/FVC with r = − 0.861, p < 0.001*) better than the whole lung CT percentage emphysema score (FEV1 with r = − 0.635, p = 0.027; and FEV1/FVC with r = − 0.652, p = 0.021).

Conclusion

Lobar ventilation with HPX-MRI showed a strong correlation with lobar ventilation and perfusion measurements derived from SPECT/CT, and is better than the emphysema score obtained with high-resolution CT.

Key Points

The ventilation hyperpolarized xenon-129 MRI correlates well with ventilation and perfusion with SPECT/CT with the advantage of higher temporal and spatial resolution.
• The hyperpolarized xenon-129 MRI correlates with the PFT measurements better than the high-resolution CT with the advantage of avoiding the use of ionizing radiation.
Hinweise

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1007/​s00330-018-5888-y) contains supplementary material, which is available to authorized users.
Abkürzungen
129Xe
Xenon-129
3He
Helium-3
99mTc-DTPA
Technetium-99m diethylene-triamine-pentaacetate
COPD
Chronic obstructive pulmonary disease
CT
Computed tomography
FEV1
Forced expiratory volume in 1 s
FVC
Forced vital capacity
HP
Hyperpolarized
HPX
Hyperpolarized 129Xe
LLL
Left lower lobe
LUL
Left upper lobe
MRI
Magnetic resonance imaging
PFT
Pulmonary function test
Q-SPECT
Perfusion SPECT
RLL
Right lower lobe
RML
Right middle lobe
RUL
Right upper lobe
SPECT
Single-photon emission CT
T1
The longitudinal decay time constant
V-SPECT
Ventilation SPECT
α
Flip angle

Introduction

Chronic obstructive pulmonary disease (COPD), characterized by airflow limitation and parenchymal destruction (emphysema), is currently the fourth leading cause of death worldwide, and its incidence is predicted to increase in the future [1, 2]. The conventional method of assessment of lung function in COPD is performed by using pulmonary function tests, providing an overall measure of lung function but providing limited information about regional or lobar function. The heterogeneous nature of COPD means that accurate and detailed information on regional structural and functional abnormalities are required to better characterize disease severity and enable improved choice of potential therapy, for example, lung volume reduction surgery or endobronchial valves [3]. These targeted regional therapies require robust and detailed functional and structural imaging both to support patient selection and to determine therapeutic response.
High-resolution computed tomography (CT) is widely used to assess lung structure in COPD [4, 5]. Lung parenchymal attenuation has been correlated with emphysema and pulmonary function test (PFT) measurements. Ventilation/perfusion single-photon emission CT (V/Q-SPECT/CT) has also been used to assess ventilation and perfusion in COPD [610]. In clinical practice, V/Q-SPECT has been shown to be a useful imaging technique in the detection of severe ventilation defects in patients with COPD [11]. Its relatively low spatial and temporal resolution may affect the accuracy of ventilation defects measured with V-SPECT [12, 13], and the radiation exposure may be a limiting factor in its use as a tool in the investigation and follow-up of patients with COPD [14, 15].
Over the last decade, the advent of non-ionizing hyperpolarized (HP) gas, i.e., 3He and 129Xe, magnetic resonance imaging (MRI), has shown considerable promise in the detection of regional ventilation defects in patients with COPD [1620]. Although HP 3He exhibits intrinsically stronger MRI signal than HP 129Xe, the use of naturally abundant 129Xe is increasing due to its increased availability, lower cost, and its additional ability to be used to produce an imaging measure of gas transfer [2123]. Conventional proton MRI of lungs, using oxygen, has also been reported to be a promising approach for ventilation and perfusion imaging [24]; however, it is limited by its inherent very low signal-to-noise ratio in the lungs [25].
Combining the increased sensitivity of HP gas MRI in the detection of ventilation defects with the high spatial resolution of thoracic CT has been reported to provide accurate quantification of lobar-specific lung ventilation [3, 2629]. However, lobar gas ventilation measurements are not possible using CT as this only provides information about lung structure and not ventilation. Previously, Stavngaard et al compared HP 3He MRI to 81mKr ventilation scintigraphy using a visual scoring method and showed that the large ventilation defects correlated between the two imaging modalities in healthy patients and a COPD cohort [30]. Stavngaard et al reported two main limitations in his comparison of HP 3He MRI and 81mKr ventilation scintigraphy: (i) HP 3He MRI signal was influenced by the decay of magnetization and (ii) the comparison was performed using whole lung ventilation and HP 3He MRI. Although HP gas MRI has been shown to be sensitive in the detection of ventilation defects, the HP gas MRI signal may be influenced by multiple factors related to the gas hyperpolarization level and the decay of HP gas magnetization as a function of the number of RF pulses, flip angle (α), longitudinal decay time constant of hyperpolarization (T1), imaging hardware, and/or the MR sequence (i.e., k-space sampling) [31]. Recently, the development of rapid HPX-MRI imaging techniques has enabled the acquisition of time-series images in a single imaging session, in turn allowing measurement and/or correction of α and T1 variations [32, 33]. Using a rapid spiral k-space MRI approach, time-series images can be obtained in a single breath-hold interval allowing the measurement of α and T1 enabling the correction of the factors that may influence the HP gas MRI signal.
The objective of this study was to derive accurate lobar ventilation measurements using a rapid time-series HPX-MRI technique correcting the α and T1 variations, in a cohort of patients with COPD, and to compare them to lobar lung percentage emphysema scores measured using high-resolution CT, lobar lung ventilation/perfusion scores measured using technetium-99m diethylene-triamine-pentaacetate (99mTc-DTPA) V/Q-SPECT, and lung function parameters from PFTs.

Methods

Subject enrollment

The study was approved by the National Research Ethics Service Committee, and written informed consent was obtained from all patients (REC approval number: 11/SC/0488). The cohort consisted of 12 patients with COPD (GOLD stages I to IV). Subject demographics, FEV1 (%Pred), and FEV1/FVC measurements from PFTs are detailed in Table 1. Male (n = 4) and female (n = 8) subjects enrolled had average ages of 65.6 ± 5.0 and 61.5 ± 10.8. The patients were scanned using three imaging modalities including high-resolution CT, time-series HPX-MRI, proton MRI, V/Q-SPECT, and anatomical low-dose CT images. All the scans and PFTs were performed on the same day. PFTs were performed according to ATS/ERS guidelines.
Table 1
Subject demographics and lung function test
Subject number
Sex (male/female)
Age (years)
GOLD stage
FEV1(% predicted)
FEV1/FVC (%)
1
Female
72
II
61
70
2
Male
67
III
41
49
3
Male
65
III
46
51
4
Female
58
II
57
68
5
Male
64
III
46
51
6
Male
73
IV
25
37
7
Male
62
II
63
63
8
Male
58
II
47
57
9
Male
64
II
63
75
10
Male
72
II
61
70
11
Female
68
III
30
47
12
Female
48
I
74
68
M ± SD
 
64 ± 7
 
51 ± 14
59 ± 12
FEV1, forced expiratory volume in 1 s; FVC, forced vital capacity

High-resolution CT

Thin-slice (0.625 mm) CT images were acquired (Discovery 670; GE Healthcare) 60 s post-administration of 100 mL of intravenous iohexol contrast (equivalent to 300 mg of organic iodine per mL), administered as part of our approved research protocol, with the following CT parameters: FOV of 50 cm, current 50–400 smart mA, voltage of 120 kV, tube collimation of 1.25 mm, and beam pitch of 0.938:1. Images were acquired after inspiration of air in the supine position. The high-resolution CT images were used to delineate the three lobes in the right lung (i.e., right upper lobe (RUL), right middle lobe (RML), and right lower lobe (RLL)) and two lobes in the left lung (i.e., left upper lobe (LUL), left lower lobe (LLL)). The absolute CT-%emphysema score for each lobe was calculated using dedicated open-access software (Pulmonary Toolkit, PTK, version 3) representing the ratio of number of pixels less than the signal threshold of – 950 HU to the total number of pixels in each lobe as previously described [3]. The percentage CT emphysema was calculated using the equation below:
$$ \%\mathrm{Emphysema}=\left({n}_{\mathrm{pixel}}/{V}_{\mathrm{Lobe}}\ \right)\times 100 $$
where npixel is the number of pixels less than the signal threshold of – 950 HU and VLobe is the volume of lobe.

V/Q-SPECT/CT

SPECT and low-dose CT images were acquired using a GE Discovery 670 SPECT/CT scanner according to local standard protocols. Ventilation SPECT images were acquired using 500 MBq technetium-99m diethylene-triamine-pentaacetate (99mTc-DTPA), LEHR collimators, 64 × 64 matrix size, 20 s per projection with aerosol produced by a SmartVent delivery system (Diagnostic Imaging Ltd., Welford, UK). Perfusion SPECT/CT images were then acquired, low energy, high-resolution (LEHR) collimators, 128 × 128 matrix size, 30 s per projection. This SPECT/CT system has a SPECT spatial resolution of ~ 10 mm, with ~ 4 mm pixel size for a 128 × 128 matrix size. SPECT images were reconstructed using the accompanied low-dose CT for attenuation correction with commercially available software (Xeleris 3, GE Healthcare, Milwaukee, USA). SPECT/CT lobar lung ventilation and perfusion were calculated using semi-automated software (Hermes Lung Lobar Analysis version 2, Hermes Medical Solutions AB, Stockholm, Sweden) by an experienced radiologist (M.C.). The relative percentage ventilation/perfusion (i.e., relative SPECT-%ventilation and relative SPECT-%perfusion) represented the ratio of sum of signal in each lobe and volume of whole lung from low-dose CT images assuming that the sum of the lobar percentages will add up to 100%. Therefore, the absolute CT-%emphysema score was conceptually different to the relative SPECT-%perfusion and relative SPECT-%ventilation although they are both expected to correlate with the ventilation defects of COPD. The percentage lobar ventilation and perfusion were calculated using the equation below:
$$ \%\mathrm{Ventilation}=\left({S}_{\mathrm{lobe}}/{V}_{\mathrm{lung}}\right)\times 100 $$
where Slobe is the sum of signal in a lobe and Vlung is the volume of the whole lung.

Proton MRI

Anatomical proton MR images were acquired on a 1.5-T MR scanner (Signa HDx, GEHC, Milwaukee, WI) using the following scanning parameters: field of view 40 × 40 cm2, bandwidth 125 kHz, TE/TR 2.8 ms/1.2 ms, matrix 128 × 128, slice thickness 15 mm; 13 slices were acquired from posterior to anterior in the coronal plane and a single slice in axial and sagittal planes.

HPX-MRI

Imaging was performed using 1-L bags of HP-enriched xenon gas (87% 129Xe) polarized to 10–15% using a commercially available polarizer (Model 9300, Polarean, Durham, NC). Time-series HPX images were acquired in the coronal plane using 13 slices with a slice thickness of 15 mm and field of view of 32 cm and constructed with an image matrix size of 128 × 128. Time-series HPX-MRI involved the acquisition of 8 sets of volume images in a single ~ 20-s breath-hold using 8-interleave spiral k-space sampling leading a time delay of ~ 2.5 s for each volume image (i.e., temporal resolution of ~ 2.5 s) and the pixel resolution of 2.5 mm (spatial resolution 2–3 mm) [32]. The time-series HPX-MRI allowed the calculation of the relative percentage ventilation (i.e., relative HPX-%ventilation) similar to the concept of SPECT relative perfusion and ventilation (i.e., relative SPECT-%perfusion and relative SPECT-%ventilation). Additionally, the absolute percentage ventilation (i.e., the absolute HPX-%ventilation) similar to the absolute CT-%emphysema score was calculated using a signal threshold method in each lung lobe.
The lobar lung masks obtained from the CT images were co-registered to proton MRI anatomical images and HPX-MRI for calculation of lobar ventilation using previously described open-source software (ITK-SNAP) [34]. Thereafter, the registered lung lobar masks applied to the HPX time-series images yielding the HPX signal time curves was performed using MATLAB. The HPX signal time curves were then fitted by the HP signal loss equations for calculation and correction of flip angle (α) and the longitudinal HP signal decay time (T1), as explained in Supplementary Material 1 [32]. The effects of flip angle variations on the signal dynamics and image intensity are also explained in Supplementary Material 2.

The relative HPX-%ventilation

The percentage lobar lung ventilation relative to the whole lung volume was calculated for comparison to the relative SPECT-%ventilation and SPECT-%perfusion. The relative HPX-%ventilation was calculated as the ratio of the sum of signal in each lobe and volume of whole lung from the high-resolution CT images assuming that the sum of the lobar percentages will also add up to 100% similar to the relative SPECT-%ventilation.

The absolute HPX-%ventilation

For comparison with absolute CT-%emphysema scores, the percentage ventilation defects were measured using a signal threshold method previously used for similar comparison between HP 3He MRI and CT-%emphysema score [27]. The HPX signal threshold was defined as 5% of the HPX signal measured across the whole lungs. The absolute HPX-%ventilation score was calculated as the ratio of the number of pixels below the signal threshold to the total number of pixels.

Statistical analysis

All statistical tests were performed using GraphPad Prism (version 7.00, GraphPad Software, CA, USA). The absolute CT-%emphysema, relative HPX-%ventilation, and relative V/Q-SPECT/CT scores were compared using Pearson’s correlation with a confidence interval of 95% to investigate any significant differences. Linear regression analysis was also used to investigate the relationship between the imaging modalities for lobar measurements across the entire subject population. FEV1 (%Pred) and FEV1/FVC measured using PFTs were also compared to the whole lung absolute CT-%emphysema score and the absolute HPX-%ventilation for each subject.

Results

Twelve subjects with a mean FEV1 (%Pred) = 51 ± 14 and FEV1/FVC (%) = 59 ± 12 as shown in Table 1 were successfully scanned using HPX-MRI and CT. The first subject was not scanned with V/Q-SPECT/CT and the second subject was not scanned with Q-SPECT.
Representative coronal slices from CT images including the emphysema map, proton MRI, HPX-MRI, and V/Q-SPECT/CT of a severe COPD subject (stages III and IV, subjects 3 and 6 in Table 1) are shown in Fig. 1a–d, respectively. The high percentage areas of emphysema (> 20%) are indicated with yellow lines on the CT in both lower lobes as shown in Fig. 1a with lung parenchyma of low attenuation (< − 950 HU) highlighted in color. Areas of CT emphysema in both lower lobes are in visual agreement with the regions of low ventilation on HPX-MRI in Fig. 1b and regions of low ventilation and perfusion on V/Q-SPECT/CT in Fig. 1c, d.
The lobar CT, HPX-MRI, and V/Q-SPECT/CT measurements from two COPD subjects with GOLD stage IV are shown in Fig. 2a, c individually. The CT-%emphysema scores were 29% and 25% in the RLL and LLL and were greater than in the RUL = 15%, RML = 18%, and LUL = 18%. The high CT-%emphysema in the lower lobes of the lungs corresponded to conspicuous ventilation defects on HPX-MRI with the relative HPX-%ventilation of the RLL = 9% and LLL = 13%, in the V-SPECT images with the relative SPECT-%ventilation of the RLL = 5% and LLL = 6%, and in the Q-SPECT images with the relative SPECT-%perfusion of the RLL = 8% and LLL = 8%. Similarly, another COPD subject GOLD stage IV with a high CT-%emphysema was also inversely correlated to the relative HPX-%ventilation (Pearson’s correlation: r = − 0.856, p < 0.05*), SPECT-%ventilation (Pearson’s correlation: r = − 0.822, p < 0.05*), and SPECT-%perfusion (Pearson’s correlation: r = − 0.828 and p < 0.05*) in Fig. 2c. Although the inversely proportional results were statistically significant in severe COPD subjects (GOLD stage IV), there was a poor correlation between the absolute CT-%emphysema and the relative lobar measurement scores in two COPD subjects (GOLD stage II) in Fig. 2b, d, individually.
The linear regression of lobar measurements in all COPD subjects is shown between the absolute CT-%emphysema and the relative HPX-%ventilation, the absolute HPX-%ventilation, SPECT-%perfusion, and SPECT-%ventilation in Fig. 3a–d, respectively. The linear slopes were negative between CT-%emphysema score and the relative HPX-%ventilation (slope = − 0.36 ± 0.15, p = 0.02*; r = − 0.313, p = 0.015*), the absolute HPX-%ventilation (slope = 1.84 ± 0.15, p < 0.01*; r = 0.701, p < 0.0001*), SPECT-%perfusion (slope = − 0.38 ± 0.15, p = 0.01*; r = − 0.374, p = 0.007*), and SPECT-%ventilation (slope = − 0.28 ± 0.11, p = 0.02*; r = − 0.319, p = 0.017*).
The relative measurements from HPX-MRI and V/Q-SPECT/CT are compared in Fig. 4. The correlations were r = 0.767, r = 0.644, and r = 0.884 with p < 0.001 between the relative HPX-%ventilation and SPECT-%perfusion, between the relative HPX-%ventilation and SPECT-%ventilation, and between the SPECT-%ventilation and SPECT-%perfusion in Fig. 4a–c, respectively.
Figure 5 demonstrates the comparison between PFT measurements FEV1 (%Pred) and FEV1/FVC (%) with whole lung absolute HPX-%ventilation in Fig. 5a, b and absolute CT-%emphysema in Fig. 5c, d. There was a statistically significant correlation between HPX-%ventilation and FEV1 (%Pred) and between HPX-%ventilation and FEV1/FVC (%) with r = − 0.886 and r = − 0.861 with p < 0.001 in Fig. 5a, b suggesting a stronger correlation and then CT-%emphysema and FEV1 (%Pred) and CT-%emphysema and FEV1/FVC (%) with r = − 0.635 with p = 0.027 and r = − 0.652 with p = 0.021.

Discussion

The relative and absolute lobar percentage ventilation defects obtained using a time-series HPX-MRI technique have been compared systematically to (i) the relative lobar ventilation and perfusion scores measured using V/Q-SPECT/CT, (ii) the absolute lobar emphysema score measured using high-resolution CT, and (iii) lung function (i.e., FEV1 (%Pred) and FEV1/FVC) in a COPD cohort. The study findings suggest that there is a very strong correlation between the lobar lung measurements of relative percentage ventilations between the time-series HPX-MRI and V/Q-SPECT/CT. Additionally, time-series HPX-MRI allowed measurement of absolute percentage ventilation of whole lung and correlates with FEV1 (%Pred) and FEV1/FVC measurements better than CT in a COPD cohort with GOLD stages I–IV. Compared to V/Q-SPECT/CT, the time-series HPX-MRI presents a promising non-ionizing technique for longitudinal assessment of COPD, because of its very high temporal resolution (2.5 s) and spatial resolution (2–3 mm) and as it may be employed repeatedly and only takes a few minutes to perform.
The HPX gas signal intensity directly correlates to ventilation in the lung airspaces; however, it may be influenced by other factors including the choice of k-space sampling, RF coil performance and design (i.e., surface or volume coils), and magnetic field strength [32, 35, 36]. The flip angle profiles can significantly vary over the entire imaging volume particularly for the surface RF coils as shown in Supplementary Fig. 2 resulting in variation in the signal intensities of up to a factor of 2 between the anterior and posterior regions of the RUL and LUL of the lung. Despite the HPX-MRI being acquired with a spiral k-space sampling approach using eight interleaves with relatively lower spatial resolution (pixel resolution of 2.5 mm) than the previously used Cartesian k-space sampling method (pixel resolution of ~ 2 mm) [3], the temporal resolution with the proposed technique in this study was higher by a factor of ~ 5 than the previously reported Cartesian k-space sampling method. The use of the time-series HPX-MRI technique can further improve the assessment of ventilation defects by eliminating the RF coil flip angle variations allowing relative and absolute measurements of ventilation defects. Eight time steps were used in this study for estimating the flip angle and T1, allowed a very high goodness-of-fit (R-squared > 0.98), as shown in the supplementary materials. In theory, using three time steps would be sufficient for solving the three unknowns as explained in the supplementary material. Although all the patients in our study were able to tolerate a 20-s breath-hold to enable eight time step scanning, the required number of images (i.e., time steps) can be reduced for the patients who are unable to manage a breath-hold interval of 20 s. Conceptually, the spatial resolution would be further increased by using less time steps and a higher number of interleaves depending on the clinical information and sensitivity required.
The negative correlation between the relative HPX-%ventilation and CT-%emphysema is consistent with previous findings reported by Matin et al [3] in a COPD cohort. As expected, the trend of correlation between HPX-%ventilation and CT-%emphysema depended on the method of HPX-%ventilation calculation (i.e., relative or absolute). There was a significant linear correlation between absolute HPX-%ventilation and CT-%emphysema, similar to a previous HP 3He study by Tahir et al [27, 37]. Despite the statistical correlation between CT-%emphysema score and HPX-%ventilation score, the intrinsic variations between the two imaging modalities are likely due to the sensitivity of (i) HPX to airway blockages, mucus plugs, and collapse of airways and (ii) CT’s structural assessment of the lungs as discussed previously [28, 3840].
Although the correlation between CT and HP gas (129Xe and 3He) has been reported widely, this is the first study to our knowledge comparing lobar ventilation defects from HPX-MRI to V/Q-SPECT/CT. Stavngaard et al investigated large ventilation defects in COPD subjects using a visual (i.e., subjective) scoring factor and showed a good correlation between HP 3He gas MRI and regional 81mKr gas ventilation scintigraphy. However, the objective computational comparison between HP 3He gas MRI and 81mKr ventilation scintigraphy showed a relatively low correlation (r = 0.45, p = 0.016). Although there is an expected difference in diffusion between aerosol radiotracers (i.e., 81mKr) and gas radiotracers (99mTc-DTPA) or HP 129Xe gas, the measured relative lobar ventilation measures correlated better in our study between HPX-MRI and 99mTc-DTPA V/Q-SPECT/CT.
As expected, HPX-MRI provided significantly higher spatial resolution and temporal resolution than V/Q-SPECT/CT. Additionally, there is image blurring in V/Q-SPECT compared to HPX-MRI images, due to motion artifact, because SPECT is performed as the patient breathes normally and the images are acquired over 30 to 40 min. In this respect, the ventilation defects identified on SPECT scans correspond to stationary ventilation defects that have stabilized after many inhalation cycles, making it insensitive to the time course of ventilation dynamics. However, HPX-MRI can capture the dynamics of xenon gas ventilation during the wash-in, breath-hold, and washout cycles separately enabling correlation with different physiological information (i.e., delayed ventilation) as discussed previously [32]. Nonetheless, the lobar lung analysis of the V/Q-SPECT images provided sufficient resolution, to confirm that the lobar ventilation and perfusion were comparable to HPX-MRI, although pixel by pixel analysis of ventilation defects may reveal greater differences between the two imaging modalities. At present a significant limitation when considering the value of HPX-MRI to SPECT/CT is that HPX-MRI is not yet in widespread use as a routine clinical imaging technique, although the body of evidence to support its use is increasing.
Although our CT scans were performed using intravenous contrast as part of our approved research protocol, calculating emphysema scores in patient with COPD does not require contrast [41]. As well as enabling emphysema scores to be calculated, it is also possible to calculate bronchial wall thickness and air flow restriction using novel CT techniques [4244].
Although the uneven distribution of Technegas between V-SPECT and Q-SPECT is to be expected as previously reported by Bajc et al [11], the agreement between the V-SPECT and Q-SPECT measurements was greater than the agreement between HPX-MRI and V/Q-SPECT/CT. This may be because the lobar ventilation and perfusion scores in SPECT were performed using the low-dose CT data acquired in the same imaging session as the V-SPECT and Q-SPECT, potentially enabling better coregistration, whereas the lobar ventilation analysis of HPX-MRI requires image co-registration to CT performed at a different time to the HPX-MRI and is likely to be less accurate. Even though the lungs are deformable, ITK-SNAP was able to register HPX-MRI images to CT using manual segmentation, and in the future, the increased spatial resolution of conventional proton MRI may enable improved lobar segmentation, which will significantly improve the lobar analysis of HPX-MRI ventilation defects. Although in comparison, the dedicated automated software used for V-SPECT and Q-SPECT co-registration and analysis may also provide more accurate image data analysis. It is also important to highlight that the regional (i.e., pixel by pixel) comparisons from the anterior to the posterior parts of the lungs may show a larger variation with HPX-MRI than with V/Q-SPECT/CT due to differences in both the imaging processing, and the temporal and spatial resolution, and need further investigation. As such, this study raises additional questions about which imaging modality would be more sensitive to early-stage COPD when using pixel by pixel comparison of mild ventilation defects in patients with GOLD stages I–II.

Conclusion

We have successfully demonstrated the measurement of absolute and relative percentage lobar ventilation using a novel time-series HPX-MRI sequence that corrects for intrinsic MR parameters in a small cohort of patients with COPD. This time-series HPX-MRI approach has been validated through comparison with V/Q SPECT/CT and high-resolution CT. Relative lobar ventilation measured by time-series HPX-MRI correlated statistically with relative percentage lobar perfusion and ventilation scores obtained with V/Q-SPECT/CT. Furthermore, a strong agreement between the absolute lobar ventilation from time-series HPX-MRI and the absolute lobar CT percentage emphysema score has been shown. Finally, the correlation between whole lung HPX-MRI and PFTs including FEV1 (%Pred) and FEV1/FVC was stronger than the whole lung CT emphysema score.

Compliance with ethical standards

Guarantor

The scientific guarantor of this publication is Professor Fergus Gleeson.

Conflict of interest

The authors of this manuscript declare no relationships with any companies, whose products or services may be related to the subject matter of the article.

Statistics and biometry

One of the authors has significant statistical expertise, and no complex statistical methods were necessary for this paper.
Written informed consent was obtained from all subjects (patients) in this study.

Ethical approval

Institutional Review Board approval was obtained.

Methodology

• prospective
• case-control study
• performed at one institution
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

© Springer Medizin

Bis 11. April 2024 bestellen und im ersten Jahr 50 % sparen!

e.Med Radiologie

Kombi-Abonnement

Mit e.Med Radiologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Radiologie, den Premium-Inhalten der radiologischen Fachzeitschriften, inklusive einer gedruckten Radiologie-Zeitschrift Ihrer Wahl.

© Springer Medizin

Bis 11. April 2024 bestellen und im ersten Jahr 50 % sparen!

Anhänge

Electronic supplementary material

Literatur
1.
Zurück zum Zitat Lopez AD, Shibuya K, Rao C et al (2006) Chronic obstructive pulmonary disease: current burden and future projections. Eur Respir J 27:397–412CrossRefPubMed Lopez AD, Shibuya K, Rao C et al (2006) Chronic obstructive pulmonary disease: current burden and future projections. Eur Respir J 27:397–412CrossRefPubMed
2.
Zurück zum Zitat Adeloye D, Chua S, Lee C et al (2015) Global and regional estimates of COPD prevalence: systematic review and meta-analysis. J Glob Health 5:020415CrossRefPubMedPubMedCentral Adeloye D, Chua S, Lee C et al (2015) Global and regional estimates of COPD prevalence: systematic review and meta-analysis. J Glob Health 5:020415CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Matin TN, Rahman N, Nickol AH et al (2017) Chronic obstructive pulmonary disease: lobar analysis with hyperpolarized 129Xe MR imaging. Radiology 282:857–868CrossRefPubMed Matin TN, Rahman N, Nickol AH et al (2017) Chronic obstructive pulmonary disease: lobar analysis with hyperpolarized 129Xe MR imaging. Radiology 282:857–868CrossRefPubMed
4.
Zurück zum Zitat Matsuoka S, Kurihara Y, Yagihashi K, Hoshino M, Nakajima Y (2008) Airway dimensions at inspiratory and expiratory multisection CT in chronic obstructive pulmonary disease: correlation with airflow limitation. Radiology 248:1042–1049CrossRefPubMed Matsuoka S, Kurihara Y, Yagihashi K, Hoshino M, Nakajima Y (2008) Airway dimensions at inspiratory and expiratory multisection CT in chronic obstructive pulmonary disease: correlation with airflow limitation. Radiology 248:1042–1049CrossRefPubMed
5.
Zurück zum Zitat Litmanovich D, Boiselle PM, Bankier AA (2009) CT of pulmonary emphysema--current status, challenges, and future directions. Eur Radiol 19:537–551CrossRefPubMed Litmanovich D, Boiselle PM, Bankier AA (2009) CT of pulmonary emphysema--current status, challenges, and future directions. Eur Radiol 19:537–551CrossRefPubMed
6.
Zurück zum Zitat Heussel CP, Herth FJ, Kappes J et al (2009) Fully automatic quantitative assessment of emphysema in computed tomography: comparison with pulmonary function testing and normal values. Eur Radiol 19:2391–2402CrossRefPubMed Heussel CP, Herth FJ, Kappes J et al (2009) Fully automatic quantitative assessment of emphysema in computed tomography: comparison with pulmonary function testing and normal values. Eur Radiol 19:2391–2402CrossRefPubMed
7.
Zurück zum Zitat Coxson HO, Dirksen A, Edwards LD et al (2013) The presence and progression of emphysema in COPD as determined by CT scanning and biomarker expression: a prospective analysis from the ECLIPSE study. Lancet Respir Med 1:129–136CrossRefPubMed Coxson HO, Dirksen A, Edwards LD et al (2013) The presence and progression of emphysema in COPD as determined by CT scanning and biomarker expression: a prospective analysis from the ECLIPSE study. Lancet Respir Med 1:129–136CrossRefPubMed
8.
Zurück zum Zitat Froeling V, Heimann U, Huebner RH et al (2015) Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema? Ann Nucl Med 29:528–534 Froeling V, Heimann U, Huebner RH et al (2015) Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema? Ann Nucl Med 29:528–534
9.
Zurück zum Zitat De Backer JW, Vos WG, Vinchurkar SC et al (2010) Validation of computational fluid dynamics in CT-based airway models with SPECT/CT. Radiology 257:854–862CrossRefPubMed De Backer JW, Vos WG, Vinchurkar SC et al (2010) Validation of computational fluid dynamics in CT-based airway models with SPECT/CT. Radiology 257:854–862CrossRefPubMed
10.
Zurück zum Zitat Jogi J, Markstad H, Tufvesson E, Bjermer L, Bajc M (2015) The added value of hybrid ventilation/perfusion SPECT/CT in patients with stable COPD or apparently healthy smokers. Cancer-suspected CT findings in the lungs are common when hybrid imaging is used. Int J Chron Obstruct Pulmon Dis 10:25–30PubMed Jogi J, Markstad H, Tufvesson E, Bjermer L, Bajc M (2015) The added value of hybrid ventilation/perfusion SPECT/CT in patients with stable COPD or apparently healthy smokers. Cancer-suspected CT findings in the lungs are common when hybrid imaging is used. Int J Chron Obstruct Pulmon Dis 10:25–30PubMed
11.
Zurück zum Zitat Bajc M, Chen Y, Wang J et al (2017) Identifying the heterogeneity of COPD by V/P SPECT: a new tool for improving the diagnosis of parenchymal defects and grading the severity of small airways disease. Int J Chron Obstruct Pulmon Dis 12:1579–1587CrossRefPubMedPubMedCentral Bajc M, Chen Y, Wang J et al (2017) Identifying the heterogeneity of COPD by V/P SPECT: a new tool for improving the diagnosis of parenchymal defects and grading the severity of small airways disease. Int J Chron Obstruct Pulmon Dis 12:1579–1587CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Ax M, Karlsson LL, Sánchez-Crespo A et al (2013) Regional lung ventilation in humans during hypergravity studied with quantitative SPECT. Respir Physiol Neurobiol 189:558–564CrossRefPubMed Ax M, Karlsson LL, Sánchez-Crespo A et al (2013) Regional lung ventilation in humans during hypergravity studied with quantitative SPECT. Respir Physiol Neurobiol 189:558–564CrossRefPubMed
13.
Zurück zum Zitat Petersson J, Rohdin M, Sánchez-Crespo A et al (2006) Paradoxical redistribution of pulmonary blood flow in prone and supine humans exposed to hypergravity. J Appl Physiol (1985) 100:240–248CrossRef Petersson J, Rohdin M, Sánchez-Crespo A et al (2006) Paradoxical redistribution of pulmonary blood flow in prone and supine humans exposed to hypergravity. J Appl Physiol (1985) 100:240–248CrossRef
14.
Zurück zum Zitat Petersson J, Sánchez-Crespo A, Rohdin M et al (2004) Physiological evaluation of a new quantitative SPECT method measuring regional ventilation and perfusion. J Appl Physiol (1985) 96:1127–1136CrossRef Petersson J, Sánchez-Crespo A, Rohdin M et al (2004) Physiological evaluation of a new quantitative SPECT method measuring regional ventilation and perfusion. J Appl Physiol (1985) 96:1127–1136CrossRef
15.
Zurück zum Zitat Petersson J, Sánchez-Crespo A, Larsson SA, Mure M (2007) Physiological imaging of the lung: single-photon-emission computed tomography (SPECT). J Appl Physiol (1985) 102:468–476CrossRef Petersson J, Sánchez-Crespo A, Larsson SA, Mure M (2007) Physiological imaging of the lung: single-photon-emission computed tomography (SPECT). J Appl Physiol (1985) 102:468–476CrossRef
16.
Zurück zum Zitat Parraga G, Ouriadov A, Evans A et al (2007) Hyperpolarized 3He ventilation defects and apparent diffusion coefficients in chronic obstructive pulmonary disease: preliminary results at 3.0 Tesla. Invest Radiol 42:384–391CrossRefPubMed Parraga G, Ouriadov A, Evans A et al (2007) Hyperpolarized 3He ventilation defects and apparent diffusion coefficients in chronic obstructive pulmonary disease: preliminary results at 3.0 Tesla. Invest Radiol 42:384–391CrossRefPubMed
17.
Zurück zum Zitat Swift AJ, Wild JM, Fichele S et al (2005) Emphysematous changes and normal variation in smokers and COPD patients using diffusion 3He MRI. Eur J Radiol 54:352–358CrossRefPubMed Swift AJ, Wild JM, Fichele S et al (2005) Emphysematous changes and normal variation in smokers and COPD patients using diffusion 3He MRI. Eur J Radiol 54:352–358CrossRefPubMed
18.
Zurück zum Zitat Driehuys B, Martinez-Jimenez S, Cleveland ZI et al (2012) Chronic obstructive pulmonary disease: safety and tolerability of hyperpolarized 129Xe MR imaging in healthy volunteers and patients. Radiology 262:279–289CrossRefPubMedPubMedCentral Driehuys B, Martinez-Jimenez S, Cleveland ZI et al (2012) Chronic obstructive pulmonary disease: safety and tolerability of hyperpolarized 129Xe MR imaging in healthy volunteers and patients. Radiology 262:279–289CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Virgincar RS, Cleveland ZI, Kaushik SS et al (2013) Quantitative analysis of hyperpolarized 129Xe ventilation imaging in healthy volunteers and subjects with chronic obstructive pulmonary disease. NMR Biomed 26:424–435CrossRefPubMed Virgincar RS, Cleveland ZI, Kaushik SS et al (2013) Quantitative analysis of hyperpolarized 129Xe ventilation imaging in healthy volunteers and subjects with chronic obstructive pulmonary disease. NMR Biomed 26:424–435CrossRefPubMed
20.
Zurück zum Zitat Kirby M, Pike D, Sin DD, Coxson HO, McCormack DG, Parraga G (2015) COPD: do imaging measurements of emphysema and airway disease explain symptoms and exercise capacity? Radiology 277:872–880CrossRefPubMed Kirby M, Pike D, Sin DD, Coxson HO, McCormack DG, Parraga G (2015) COPD: do imaging measurements of emphysema and airway disease explain symptoms and exercise capacity? Radiology 277:872–880CrossRefPubMed
22.
Zurück zum Zitat Kirby M, Ouriadov A, Svenningsen S et al (2014) Hyperpolarized 3He and 129Xe magnetic resonance imaging apparent diffusion coefficients: physiological relevance in older never- and ex-smokers. Physiol Rep 2(7):e12068 Kirby M, Ouriadov A, Svenningsen S et al (2014) Hyperpolarized 3He and 129Xe magnetic resonance imaging apparent diffusion coefficients: physiological relevance in older never- and ex-smokers. Physiol Rep 2(7):e12068
23.
Zurück zum Zitat Svenningsen S, Kirby M, Starr D et al (2013) Hyperpolarized (3) He and (129) Xe MRI: differences in asthma before bronchodilation. J Magn Reson Imaging 38:1521–1530CrossRefPubMed Svenningsen S, Kirby M, Starr D et al (2013) Hyperpolarized (3) He and (129) Xe MRI: differences in asthma before bronchodilation. J Magn Reson Imaging 38:1521–1530CrossRefPubMed
24.
Zurück zum Zitat Voskrebenzev A, Gutberlet M, Klimeš F et al (2017) Feasibility of quantitative regional ventilation and perfusion mapping with phase-resolved functional lung (PREFUL) MRI in healthy volunteers and COPD, CTEPH, and CF patients. Magn Reson Med. https://doi.org/10.1002/mrm.26893 Voskrebenzev A, Gutberlet M, Klimeš F et al (2017) Feasibility of quantitative regional ventilation and perfusion mapping with phase-resolved functional lung (PREFUL) MRI in healthy volunteers and COPD, CTEPH, and CF patients. Magn Reson Med. https://​doi.​org/​10.​1002/​mrm.​26893
25.
Zurück zum Zitat Kruger SJ, Nagle SK, Couch MJ, Ohno Y, Albert M, Fain SB (2016) Functional imaging of the lungs with gas agents. J Magn Reson Imaging 43:295–315CrossRefPubMed Kruger SJ, Nagle SK, Couch MJ, Ohno Y, Albert M, Fain SB (2016) Functional imaging of the lungs with gas agents. J Magn Reson Imaging 43:295–315CrossRefPubMed
26.
Zurück zum Zitat Tahir BA, Swift AJ, Marshall H et al (2014) A method for quantitative analysis of regional lung ventilation using deformable image registration of CT and hybrid hyperpolarized gas/1H MRI. Phys Med Biol 59:7267–7277CrossRefPubMed Tahir BA, Swift AJ, Marshall H et al (2014) A method for quantitative analysis of regional lung ventilation using deformable image registration of CT and hybrid hyperpolarized gas/1H MRI. Phys Med Biol 59:7267–7277CrossRefPubMed
28.
Zurück zum Zitat Pike D, Kirby M, Eddy RL et al (2016) Regional heterogeneity of chronic obstructive pulmonary disease phenotypes: pulmonary (3)He magnetic resonance imaging and computed tomography. COPD 13:601–609CrossRefPubMed Pike D, Kirby M, Eddy RL et al (2016) Regional heterogeneity of chronic obstructive pulmonary disease phenotypes: pulmonary (3)He magnetic resonance imaging and computed tomography. COPD 13:601–609CrossRefPubMed
30.
Zurück zum Zitat Stavngaard T, Søgaard LV, Mortensen J et al (2005) Hyperpolarized 3He MRI and 81mKr SPECT in chronic obstructive pulmonary disease. Eur J Nucl Med Mol Imaging 32:448–457CrossRefPubMed Stavngaard T, Søgaard LV, Mortensen J et al (2005) Hyperpolarized 3He MRI and 81mKr SPECT in chronic obstructive pulmonary disease. Eur J Nucl Med Mol Imaging 32:448–457CrossRefPubMed
31.
Zurück zum Zitat Meersmann T, Brunner E (2015) Hyperpolarized xenon-129 magnetic resonance: concepts, production, techniques and applications, 1st edn. Royal Society of Chemistry, Cambridge Meersmann T, Brunner E (2015) Hyperpolarized xenon-129 magnetic resonance: concepts, production, techniques and applications, 1st edn. Royal Society of Chemistry, Cambridge
32.
Zurück zum Zitat Doganay O, Matin TN, McIntyre A et al (2018) Fast dynamic ventilation MRI of hyperpolarized (129) Xe using spiral imaging. Magn Reson Med 79:2597–2606CrossRefPubMed Doganay O, Matin TN, McIntyre A et al (2018) Fast dynamic ventilation MRI of hyperpolarized (129) Xe using spiral imaging. Magn Reson Med 79:2597–2606CrossRefPubMed
33.
Zurück zum Zitat Xiao S, Deng H, Duan C et al (2018) Considering low-rank, sparse and gas-inflow effects constraints for accelerated pulmonary dynamic hyperpolarized (129)Xe MRI. J Magn Reson 290:29–37CrossRefPubMed Xiao S, Deng H, Duan C et al (2018) Considering low-rank, sparse and gas-inflow effects constraints for accelerated pulmonary dynamic hyperpolarized (129)Xe MRI. J Magn Reson 290:29–37CrossRefPubMed
34.
Zurück zum Zitat Yushkevich PA, Piven J, Hazlett HC et al (2006) User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 31:1116–1128CrossRef Yushkevich PA, Piven J, Hazlett HC et al (2006) User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 31:1116–1128CrossRef
35.
Zurück zum Zitat Doganay O, Thind K, Wade T, Ouriadov A, Santyr GE (2015) Transmit-only/receive-only radiofrequency coil configuration for hyperpolarized Xe-129 MRI of rat lungs. Concepts Magn Reson Part B Magn Reson Eng 45:115–124CrossRef Doganay O, Thind K, Wade T, Ouriadov A, Santyr GE (2015) Transmit-only/receive-only radiofrequency coil configuration for hyperpolarized Xe-129 MRI of rat lungs. Concepts Magn Reson Part B Magn Reson Eng 45:115–124CrossRef
36.
Zurück zum Zitat Xu X, Norquay G, Parnell SR et al (2012) Hyperpolarized 129Xe gas lung MRI-SNR and T2* comparisons at 1.5 T and 3 T. Magn Reson Med 68:1900–1904CrossRefPubMed Xu X, Norquay G, Parnell SR et al (2012) Hyperpolarized 129Xe gas lung MRI-SNR and T2* comparisons at 1.5 T and 3 T. Magn Reson Med 68:1900–1904CrossRefPubMed
37.
Zurück zum Zitat Tahir BA, Swift AJ, Marshall H et al (2014) A method for quantitative analysis of regional lung ventilation using deformable image registration of CT and hybrid hyperpolarized gas/1H MRI. Phys Med Biol 59:7267–7277CrossRefPubMed Tahir BA, Swift AJ, Marshall H et al (2014) A method for quantitative analysis of regional lung ventilation using deformable image registration of CT and hybrid hyperpolarized gas/1H MRI. Phys Med Biol 59:7267–7277CrossRefPubMed
38.
Zurück zum Zitat Kirby M, Svenningsen S, Kanhere N et al (2013) Pulmonary ventilation visualized using hyperpolarized helium-3 and xenon-129 magnetic resonance imaging: differences in COPD and relationship to emphysema. J Appl Physiol (1985) 114:707–715CrossRef Kirby M, Svenningsen S, Kanhere N et al (2013) Pulmonary ventilation visualized using hyperpolarized helium-3 and xenon-129 magnetic resonance imaging: differences in COPD and relationship to emphysema. J Appl Physiol (1985) 114:707–715CrossRef
39.
Zurück zum Zitat Kirby M, Svenningsen S, Owrangi A et al (2012) Hyperpolarized 3He and 129Xe MR imaging in healthy volunteers and patients with chronic obstructive pulmonary disease. Radiology 265:600–610CrossRefPubMed Kirby M, Svenningsen S, Owrangi A et al (2012) Hyperpolarized 3He and 129Xe MR imaging in healthy volunteers and patients with chronic obstructive pulmonary disease. Radiology 265:600–610CrossRefPubMed
40.
Zurück zum Zitat Owrangi AM, Etemad-Rezai R, McCormack DG, Cunningham IA, Parraga G (2013) Computed tomography density histogram analysis to evaluate pulmonary emphysema in ex-smokers. Acad Radiol 20:537–545CrossRefPubMed Owrangi AM, Etemad-Rezai R, McCormack DG, Cunningham IA, Parraga G (2013) Computed tomography density histogram analysis to evaluate pulmonary emphysema in ex-smokers. Acad Radiol 20:537–545CrossRefPubMed
41.
Zurück zum Zitat Sverzellati N, Molinari F, Pirronti T, Bonomo L, Spagnolo P, Zompatori M (2007) New insights on COPD imaging via CT and MRI. Int J Chron Obstruct Pulmon Dis 2:301–312PubMedPubMedCentral Sverzellati N, Molinari F, Pirronti T, Bonomo L, Spagnolo P, Zompatori M (2007) New insights on COPD imaging via CT and MRI. Int J Chron Obstruct Pulmon Dis 2:301–312PubMedPubMedCentral
42.
Zurück zum Zitat Yahaba M, Kawata N, Iesato K et al (2014) The effects of emphysema on airway disease: correlations between multi-detector CT and pulmonary function tests in smokers. Eur J Radiol 83:1022–1028CrossRefPubMed Yahaba M, Kawata N, Iesato K et al (2014) The effects of emphysema on airway disease: correlations between multi-detector CT and pulmonary function tests in smokers. Eur J Radiol 83:1022–1028CrossRefPubMed
43.
Zurück zum Zitat Grydeland TB, Dirksen A, Coxson HO et al (2009) Quantitative computed tomography: emphysema and airway wall thickness by sex, age and smoking. Eur Respir J 34:858–865CrossRefPubMed Grydeland TB, Dirksen A, Coxson HO et al (2009) Quantitative computed tomography: emphysema and airway wall thickness by sex, age and smoking. Eur Respir J 34:858–865CrossRefPubMed
44.
Zurück zum Zitat Schroeder JD, McKenzie AS, Zach JA et al (2013) Relationships between airflow obstruction and quantitative CT measurements of emphysema, air trapping, and airways in subjects with and without chronic obstructive pulmonary disease. AJR Am J Roentgenol 201:W460–W470CrossRefPubMedPubMedCentral Schroeder JD, McKenzie AS, Zach JA et al (2013) Relationships between airflow obstruction and quantitative CT measurements of emphysema, air trapping, and airways in subjects with and without chronic obstructive pulmonary disease. AJR Am J Roentgenol 201:W460–W470CrossRefPubMedPubMedCentral
Metadaten
Titel
Time-series hyperpolarized xenon-129 MRI of lobar lung ventilation of COPD in comparison to V/Q-SPECT/CT and CT
verfasst von
Ozkan Doganay
Tahreema Matin
Mitchell Chen
Minsuok Kim
Anthony McIntyre
Daniel R. McGowan
Kevin M. Bradley
Thomas Povey
Fergus V. Gleeson
Publikationsdatum
14.12.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Radiology / Ausgabe 8/2019
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-018-5888-y

Weitere Artikel der Ausgabe 8/2019

European Radiology 8/2019 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.