Skip to main content
Erschienen in:

11.08.2023 | Original Article

Tolerability and efficacy of a reduced dose adenosine stress cardiac magnetic resonance protocol under general anesthesia in infants and children

verfasst von: Madhusudan Ganigara, Bharti Sharma, Pezad Doctor, Mohamed Nagiub, Sanja Dzelebdzic, Roby Sebastian, Munes Fares, Jeanne Dillenbeck, Gerald Greil, Tarique Hussain

Erschienen in: Pediatric Radiology | Ausgabe 11/2023

Einloggen, um Zugang zu erhalten

Abstract

Background

Intravenous adenosine induces pharmacological stress by causing vasodilatation and thus carries the risk of severe hypotension when combined with vasodilatory effects of anesthetic agents.

Objective

This study describes our experience with a reduced dose adenosine cardiac magnetic resonance imaging (MRI) protocol in young children under general anesthesia (GA).

Materials and methods

This is a retrospective report of all patients from birth to 18 years who underwent adenosine stress cardiac MRI under GA between August 2018 and November 2022. Based on our anecdotal experience of severe adverse effects in patients receiving adenosine infusion under GA and in discussion with the pediatric anesthesia team, we developed a modified protocol starting at a dose of 110 mcg/kg/min with incremental escalation to a full dose of 140 mcg/kg/min to achieve desired hemodynamic effect.

Results

Twenty-two children (mean age 6.5 years, mean weight 28 kg) satisfied the inclusion criteria. The diagnoses included Kawasaki disease (7), anomalous aortic origin of left coronary artery (3), anomalous aortic origin of right coronary artery (2), coronary fistula (3), repaired d-transposition of great arteries (2), repaired anomalous left coronary artery from pulmonary artery (2), repaired truncus arteriosus with left coronary artery occlusion (1), extracardiac-Fontan with left coronary artery myocardial bridge (1), and post heart transplantation (1). Nine patients needed dose escalation beyond 110 mcg/kg/min. Two patients had transient hypotension during testing (systemic blood pressure drop > 25 mmHg). No patient developed significant heart block or bronchospasm. Six patients (repeat study in one) demonstrated inducible perfusion defects (27%) on stress perfusion sequences—5 of whom had confirmed significant coronary abnormalities on angiography or direct surgical inspection.

Conclusion

A reduced/incremental dose adenosine stress cardiac MRI protocol under GA in children is safe and feasible. This avoids severe hypotension which is both unsafe and may result in inaccurate data.
Literatur
1.
Zurück zum Zitat Ntsinjana HN, Tann O, Hughes M et al (2017) Utility of adenosine stress perfusion CMR to assess paediatric coronary artery disease. Eur Heart J Cardiovasc Imaging 18:898–905CrossRefPubMed Ntsinjana HN, Tann O, Hughes M et al (2017) Utility of adenosine stress perfusion CMR to assess paediatric coronary artery disease. Eur Heart J Cardiovasc Imaging 18:898–905CrossRefPubMed
2.
3.
Zurück zum Zitat Schwitter J, Wacker CM, Wilke N et al (2013) MR-IMPACT II: Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary artery disease Trial: perfusion-cardiac magnetic resonance vs. single-photon emission computed tomography for the detection of coronary artery disease: a comparative multicentre, multivendor trial. Eur Heart J 34:775–781CrossRefPubMed Schwitter J, Wacker CM, Wilke N et al (2013) MR-IMPACT II: Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary artery disease Trial: perfusion-cardiac magnetic resonance vs. single-photon emission computed tomography for the detection of coronary artery disease: a comparative multicentre, multivendor trial. Eur Heart J 34:775–781CrossRefPubMed
4.
Zurück zum Zitat Biko DM, Collins RT, Partington SL et al (2018) Magnetic resonance myocardial perfusion imaging: safety and indications in pediatrics and young adults. Pediatr Cardiol 39:275–282CrossRefPubMed Biko DM, Collins RT, Partington SL et al (2018) Magnetic resonance myocardial perfusion imaging: safety and indications in pediatrics and young adults. Pediatr Cardiol 39:275–282CrossRefPubMed
5.
Zurück zum Zitat Hauser M, Bengel FM, Kühn A et al (2001) Myocardial blood flow and flow reserve after coronary reimplantation in patients after arterial switch and ross operation. Circulation 103:1875–1880CrossRefPubMed Hauser M, Bengel FM, Kühn A et al (2001) Myocardial blood flow and flow reserve after coronary reimplantation in patients after arterial switch and ross operation. Circulation 103:1875–1880CrossRefPubMed
6.
Zurück zum Zitat Secinaro A, Ntsinjana H, Tann O et al (2011) Cardiovascular magnetic resonance findings in repaired anomalous left coronary artery to pulmonary artery connection (ALCAPA). J Cardiovasc Magn Reson 13:27CrossRefPubMedPubMedCentral Secinaro A, Ntsinjana H, Tann O et al (2011) Cardiovascular magnetic resonance findings in repaired anomalous left coronary artery to pulmonary artery connection (ALCAPA). J Cardiovasc Magn Reson 13:27CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Mavrogeni S, Papadopoulos G, Douskou M et al (2004) Magnetic resonance angiography isequivalent to X-ray coronary angiography for the evaluation of coronary arteries in Kawasaki disease. J Am Coll Cardiol 43:649–652CrossRefPubMed Mavrogeni S, Papadopoulos G, Douskou M et al (2004) Magnetic resonance angiography isequivalent to X-ray coronary angiography for the evaluation of coronary arteries in Kawasaki disease. J Am Coll Cardiol 43:649–652CrossRefPubMed
8.
Zurück zum Zitat Duran SR, Huffaker T, Dixon B et al (2021) Feasibility and safety of quantitative adenosine stress perfusion cardiac magnetic resonance imaging in pediatric heart transplant patients with and without coronary allograft vasculopathy. Pediatr Radiol 51:1311–1321CrossRefPubMed Duran SR, Huffaker T, Dixon B et al (2021) Feasibility and safety of quantitative adenosine stress perfusion cardiac magnetic resonance imaging in pediatric heart transplant patients with and without coronary allograft vasculopathy. Pediatr Radiol 51:1311–1321CrossRefPubMed
9.
Zurück zum Zitat Noel CV, Krishnamurthy R, Masand P et al (2018) Myocardial stress perfusion MRI: experience in pediatric and young-adult patients following arterial switch operation utilizing regadenoson. Pediatr Cardiol 39:1249–1257CrossRefPubMed Noel CV, Krishnamurthy R, Masand P et al (2018) Myocardial stress perfusion MRI: experience in pediatric and young-adult patients following arterial switch operation utilizing regadenoson. Pediatr Cardiol 39:1249–1257CrossRefPubMed
10.
Zurück zum Zitat Noel CV, Krishnamurthy R, Moffett B, Krishnamurthy R (2017) Myocardial stress perfusion magnetic resonance: initial experience in a pediatric and young adult population using regadenoson. Pediatr Radiol 47:280–289CrossRefPubMed Noel CV, Krishnamurthy R, Moffett B, Krishnamurthy R (2017) Myocardial stress perfusion magnetic resonance: initial experience in a pediatric and young adult population using regadenoson. Pediatr Radiol 47:280–289CrossRefPubMed
11.
Zurück zum Zitat Hernandez LE (2018) Myocardial stress perfusion magnetic resonance in children with hypertrophic cardiomyopathy. Cardiol Young 28:702–708CrossRefPubMed Hernandez LE (2018) Myocardial stress perfusion magnetic resonance in children with hypertrophic cardiomyopathy. Cardiol Young 28:702–708CrossRefPubMed
12.
Zurück zum Zitat Patel SG, Husain N, Rigsby CK, Robinson JD (2022) Safety and efficacy of regadenoson for pediatric stress perfusion cardiac MRI with quantification of myocardial blood flow. Children 9:1332CrossRefPubMedPubMedCentral Patel SG, Husain N, Rigsby CK, Robinson JD (2022) Safety and efficacy of regadenoson for pediatric stress perfusion cardiac MRI with quantification of myocardial blood flow. Children 9:1332CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Kramer CM, Barkhausen J, Bucciarelli-Ducci C et al (2020) Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update. J Cardiovasc Magn Reson 22:17CrossRefPubMedPubMedCentral Kramer CM, Barkhausen J, Bucciarelli-Ducci C et al (2020) Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update. J Cardiovasc Magn Reson 22:17CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Dietz SM, Tacke CE, Kuipers IM et al (2015) Cardiovascular imaging in children and adults following Kawasaki disease. Insights Imaging 6:697–705CrossRefPubMedPubMedCentral Dietz SM, Tacke CE, Kuipers IM et al (2015) Cardiovascular imaging in children and adults following Kawasaki disease. Insights Imaging 6:697–705CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Vijarnsorn C, Noga M, Schantz D et al (2017) Stress perfusion magnetic resonance imaging to detect coronary artery lesions in children. Int J Cardiovasc Imaging 33:699–709CrossRefPubMed Vijarnsorn C, Noga M, Schantz D et al (2017) Stress perfusion magnetic resonance imaging to detect coronary artery lesions in children. Int J Cardiovasc Imaging 33:699–709CrossRefPubMed
16.
Zurück zum Zitat Fukunaga AF, Flacke WE, Bloor BC (1982) Hypotensive effects of adenosine and adenosine triphosphate compared with sodium nitroprusside. Anesth Analg 61:273–278CrossRefPubMed Fukunaga AF, Flacke WE, Bloor BC (1982) Hypotensive effects of adenosine and adenosine triphosphate compared with sodium nitroprusside. Anesth Analg 61:273–278CrossRefPubMed
17.
Zurück zum Zitat Bulley SR, Wittnich C (1995) Adenosine infusion: a rational approach towards induced hypotension. Can J Cardiol 11:327–334PubMed Bulley SR, Wittnich C (1995) Adenosine infusion: a rational approach towards induced hypotension. Can J Cardiol 11:327–334PubMed
18.
Zurück zum Zitat Manisty C, Ripley DP, Herrey AS et al (2015) Splenic switch-off: a tool to assess stress adequacy in adenosine perfusion cardiac MR imaging. Radiology 276:732–740CrossRefPubMed Manisty C, Ripley DP, Herrey AS et al (2015) Splenic switch-off: a tool to assess stress adequacy in adenosine perfusion cardiac MR imaging. Radiology 276:732–740CrossRefPubMed
19.
Zurück zum Zitat Ishida M, Schuster A, Morton G et al (2011) Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance. J Cardiovasc Magn Reson 13:28CrossRefPubMedPubMedCentral Ishida M, Schuster A, Morton G et al (2011) Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance. J Cardiovasc Magn Reson 13:28CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Schulz-Menger J, Bluemke DA, Bremerich J et al (2020) Standardized image interpretation and post-processing in cardiovascular magnetic resonance - 2020 update. J Cardiovasc Magn Reson 22:19CrossRefPubMedPubMedCentral Schulz-Menger J, Bluemke DA, Bremerich J et al (2020) Standardized image interpretation and post-processing in cardiovascular magnetic resonance - 2020 update. J Cardiovasc Magn Reson 22:19CrossRefPubMedPubMedCentral
21.
Zurück zum Zitat Buechel ERV, Balmer C, Bauersfeld U et al (2009) Feasibility of perfusion cardiovascular magnetic resonance in paediatric patients. J Cardiovasc Magn Reson 11:51CrossRefPubMedPubMedCentral Buechel ERV, Balmer C, Bauersfeld U et al (2009) Feasibility of perfusion cardiovascular magnetic resonance in paediatric patients. J Cardiovasc Magn Reson 11:51CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Fredholm BB, IJzerman AP, Jacobson KA et al (2011) International Union of Basic and Clinical pharmacology. lxxxi. nomenclature and Classification of Adenosine Receptors—An Update. Pharmacol Rev 63:1–34CrossRefPubMedPubMedCentral Fredholm BB, IJzerman AP, Jacobson KA et al (2011) International Union of Basic and Clinical pharmacology. lxxxi. nomenclature and Classification of Adenosine Receptors—An Update. Pharmacol Rev 63:1–34CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Iwamoto T, Umemura S, Toya Y et al (1994) Identification of adenosine A2 receptor-cAMP system in human aortic endothelial cells. Biochem Biophys Res Commun 199:905–910CrossRefPubMed Iwamoto T, Umemura S, Toya Y et al (1994) Identification of adenosine A2 receptor-cAMP system in human aortic endothelial cells. Biochem Biophys Res Commun 199:905–910CrossRefPubMed
24.
Zurück zum Zitat Maimon N, Titus PA, Sarelius IH (2014) Pre-exposure to adenosine, acting via A2A receptors on endothelial cells, alters the protein kinase A dependence of adenosine-induced dilation in skeletal muscle resistance arterioles. J Physiol 592:2575–2590CrossRefPubMedPubMedCentral Maimon N, Titus PA, Sarelius IH (2014) Pre-exposure to adenosine, acting via A2A receptors on endothelial cells, alters the protein kinase A dependence of adenosine-induced dilation in skeletal muscle resistance arterioles. J Physiol 592:2575–2590CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Teng B, Fil D, Tilley SL et al (2013) Functional and RNA expression profile of adenosine receptor subtypes in mouse mesenteric arteries. J Cardiovasc Pharmacol 61:70–76CrossRefPubMedPubMedCentral Teng B, Fil D, Tilley SL et al (2013) Functional and RNA expression profile of adenosine receptor subtypes in mouse mesenteric arteries. J Cardiovasc Pharmacol 61:70–76CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Ansari HR, Nadeem A, Talukder MAH et al (2007) Evidence for the involvement of nitric oxide in A2B receptor-mediated vasorelaxation of mouse aorta. Am J Physiol-Heart Circ Physiol 292:H719–H725CrossRefPubMed Ansari HR, Nadeem A, Talukder MAH et al (2007) Evidence for the involvement of nitric oxide in A2B receptor-mediated vasorelaxation of mouse aorta. Am J Physiol-Heart Circ Physiol 292:H719–H725CrossRefPubMed
28.
Zurück zum Zitat Cerqueira MD, Verani MS, Schwaiger M et al (1994) Safety profile of adenosine stress perfusion imaging: results from the adenoscan multicenter trial registry. J Am Coll Cardiol 23:384–389CrossRefPubMed Cerqueira MD, Verani MS, Schwaiger M et al (1994) Safety profile of adenosine stress perfusion imaging: results from the adenoscan multicenter trial registry. J Am Coll Cardiol 23:384–389CrossRefPubMed
29.
Zurück zum Zitat Bernhardt P, Steffens M, Kleinertz K et al (2006) Safety of adenosine stress magnetic resonance imaging using a mobile cardiac magnetic resonance system. J Cardiovasc Magn Reson 8:475–478CrossRefPubMed Bernhardt P, Steffens M, Kleinertz K et al (2006) Safety of adenosine stress magnetic resonance imaging using a mobile cardiac magnetic resonance system. J Cardiovasc Magn Reson 8:475–478CrossRefPubMed
30.
Zurück zum Zitat Prabhu AS, Singh TP, Morrow WR et al (1999) Safety and efficacy of intravenous adenosine for pharmacologic stress testing in children with aortic valve disease or Kawasaki disease. Am J Cardiol 83:284–286CrossRefPubMed Prabhu AS, Singh TP, Morrow WR et al (1999) Safety and efficacy of intravenous adenosine for pharmacologic stress testing in children with aortic valve disease or Kawasaki disease. Am J Cardiol 83:284–286CrossRefPubMed
32.
Zurück zum Zitat Monmeneu Menadas JV, García Gonzalez MP, Lopez-Lereu MP et al (2022) Safety and tolerability of regadenoson in comparison with adenosine stress cardiovascular magnetic resonance: data from a multicentre prospective registry. Int J Cardiovasc Imaging 38:195–209CrossRefPubMed Monmeneu Menadas JV, García Gonzalez MP, Lopez-Lereu MP et al (2022) Safety and tolerability of regadenoson in comparison with adenosine stress cardiovascular magnetic resonance: data from a multicentre prospective registry. Int J Cardiovasc Imaging 38:195–209CrossRefPubMed
33.
Zurück zum Zitat Sollevi A, Lagerkranser M, Irestedt L et al (1984) Controlled hypotension with adenosine in cerebral aneurysm surgery. Anesthesiology 61:400–405CrossRefPubMed Sollevi A, Lagerkranser M, Irestedt L et al (1984) Controlled hypotension with adenosine in cerebral aneurysm surgery. Anesthesiology 61:400–405CrossRefPubMed
34.
Zurück zum Zitat Öwall A, Gordon E, Lagerkranser M et al (1987) Clinical experience with adenosine for controlled hypotension during cerebral aneurysm surgery. Anesth Analg 66:229PubMed Öwall A, Gordon E, Lagerkranser M et al (1987) Clinical experience with adenosine for controlled hypotension during cerebral aneurysm surgery. Anesth Analg 66:229PubMed
35.
Zurück zum Zitat Raj V, Pudhiavan A, Hrishikesh V et al (2020) Safety profile of adenosine stress cardiac MRI in a tertiary hospital in India. Indian J Radiol Imaging 30:459–464CrossRefPubMed Raj V, Pudhiavan A, Hrishikesh V et al (2020) Safety profile of adenosine stress cardiac MRI in a tertiary hospital in India. Indian J Radiol Imaging 30:459–464CrossRefPubMed
36.
Zurück zum Zitat Fares M, Critser PJ, Arruda MJ et al (2019) Pharmacologic stress cardiovascular magnetic resonance in the pediatric population: a review of the literature, proposed protocol, and two examples in patients with Kawasaki disease. Congenit Heart Dis 14:1166–1175CrossRefPubMed Fares M, Critser PJ, Arruda MJ et al (2019) Pharmacologic stress cardiovascular magnetic resonance in the pediatric population: a review of the literature, proposed protocol, and two examples in patients with Kawasaki disease. Congenit Heart Dis 14:1166–1175CrossRefPubMed
Metadaten
Titel
Tolerability and efficacy of a reduced dose adenosine stress cardiac magnetic resonance protocol under general anesthesia in infants and children
verfasst von
Madhusudan Ganigara
Bharti Sharma
Pezad Doctor
Mohamed Nagiub
Sanja Dzelebdzic
Roby Sebastian
Munes Fares
Jeanne Dillenbeck
Gerald Greil
Tarique Hussain
Publikationsdatum
11.08.2023
Verlag
Springer Berlin Heidelberg
Erschienen in
Pediatric Radiology / Ausgabe 11/2023
Print ISSN: 0301-0449
Elektronische ISSN: 1432-1998
DOI
https://doi.org/10.1007/s00247-023-05738-y

Neu im Fachgebiet Radiologie

Stumme Schlaganfälle − ein häufiger Nebenbefund im Kopf-CT?

In 4% der in der Notfallambulanz initiierten zerebralen Bildgebung sind „alte“ Schlaganfälle zu erkennen. Gar nicht so selten handelt es sich laut einer aktuellen Studie dabei um unbemerkte Insulte. Bietet sich hier womöglich die Chance auf ein effektives opportunistisches Screening?

Stören weiße Wände und viel Licht die Bildqualitätskontrolle?

Wenn es darum geht, die technische Qualität eines Mammogramms zu beurteilen, könnten graue Wandfarbe und reduzierte Beleuchtung im Bildgebungsraum von Vorteil sein. Darauf deuten zumindest Ergebnisse einer kleinen Studie hin. 

PMBCL mit CMR: Radiatio kann ohne Risiko weggelassen werden

Patienten mit primär mediastinalem B-Zell-Lymphom (PMBCL), die nach der Induktionstherapie eine komplette metabolische Remission (CMR) erreichen und keine konsolidierende Bestrahlung erhalten, müssen offenbar keine Überlebensnachteile fürchten.

Hypoxisch-ischämische Enzephalopathie: Indikatoren für eine ungünstige Prognose

Eine US-amerikanische Studie widmete sich der Identifizierung prognostischer Parameter bei Neugeborenen mit mittelschwerer oder schwerer hypoxisch-ischämischer Enzephalopathie (HIE), die mittels induzierter Hypoxie behandelt wurden. Besonders im 24-Stunden-EEG und der MRT konnten relevante Hinweise gefunden werden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.