It is well-known that tungsten coils are biodegraded in vivo. Previous articles reported cases with follow-ups of not more than 36 months. We describe a case of missing tungsten coils and recurrent subarachnoid haemorrhage 12 years after endovascular embolisation. The relevant literature is reviewed. …
Literatur
1.
Zurück zum Zitat Bachthaler M, Lenhart M, Paetzel C, Feuerbach S, Link J, Manke C. Corrosion of tungsten coils after peripheral vascular embolisation therapy: influence on outcome and tungsten load. Catheter Cardiovasc Interv. 2004;62(3):380–4.PubMedCrossRef Bachthaler M, Lenhart M, Paetzel C, Feuerbach S, Link J, Manke C. Corrosion of tungsten coils after peripheral vascular embolisation therapy: influence on outcome and tungsten load. Catheter Cardiovasc Interv. 2004;62(3):380–4.PubMedCrossRef
2.
Zurück zum Zitat Kampmann C, Brzezinska R, Abidini M, Wenzel A, Wippermann CF, Habermehl P, et al. Biodegradation of tungsten embolisation coils used in children. Pediatr Radiol. 2002;32(12):839–43.PubMedCrossRef Kampmann C, Brzezinska R, Abidini M, Wenzel A, Wippermann CF, Habermehl P, et al. Biodegradation of tungsten embolisation coils used in children. Pediatr Radiol. 2002;32(12):839–43.PubMedCrossRef
3.
Zurück zum Zitat Peuster M, Fink C, von Schnakenburg C, Hausdorf G. Dissolution of tungsten coils does not produce systemic toxicity, but leads to elevated levels of tungsten in the serum and recanalisation of the previously occluded vessel. Cardiol Young. 2002;12(3):229–35.PubMedCrossRef Peuster M, Fink C, von Schnakenburg C, Hausdorf G. Dissolution of tungsten coils does not produce systemic toxicity, but leads to elevated levels of tungsten in the serum and recanalisation of the previously occluded vessel. Cardiol Young. 2002;12(3):229–35.PubMedCrossRef
4.
Zurück zum Zitat Weill A, Ducros V, Cognard C, Piotin M, Moret J. Letter. “Corrosion” of tungsten spirals. A disturbing finding. Interv Neuroradiol. 1998;4(4):337–40.PubMed Weill A, Ducros V, Cognard C, Piotin M, Moret J. Letter. “Corrosion” of tungsten spirals. A disturbing finding. Interv Neuroradiol. 1998;4(4):337–40.PubMed
5.
Zurück zum Zitat Lalak NJ, Moussa SA. ‘Corrosion’ of tungsten spirale coils in the genitourinary tract. Clin Radiol. 2002;57(4):305–8.PubMedCrossRef Lalak NJ, Moussa SA. ‘Corrosion’ of tungsten spirale coils in the genitourinary tract. Clin Radiol. 2002;57(4):305–8.PubMedCrossRef
6.
Zurück zum Zitat Xiao FS, Wu ZX, Li YX. Experimental study on corrosion of tungsten coils. Chin J Exp Surg. 2003;20(5):462–3. Xiao FS, Wu ZX, Li YX. Experimental study on corrosion of tungsten coils. Chin J Exp Surg. 2003;20(5):462–3.
7.
Zurück zum Zitat Peuster M, Fink C, Wohlsein P, Bruegmann M, Gunther A, Kaese V, et al. Degradation of tungsten coils implanted into the subclavian artery of New Zealand white rabbits is not associated with local or systemic toxicity. Biomaterials. 2003;24(3):393–9.PubMedCrossRef Peuster M, Fink C, Wohlsein P, Bruegmann M, Gunther A, Kaese V, et al. Degradation of tungsten coils implanted into the subclavian artery of New Zealand white rabbits is not associated with local or systemic toxicity. Biomaterials. 2003;24(3):393–9.PubMedCrossRef
8.
Zurück zum Zitat Peuster M, Fink C, von Schnakenburg C. Biocompatibility of corroding tungsten coils: in vitro assessment of degradation kinetics and cytotoxicity on human cells. Biomaterials. 2003;24(22):4057–61.PubMedCrossRef Peuster M, Fink C, von Schnakenburg C. Biocompatibility of corroding tungsten coils: in vitro assessment of degradation kinetics and cytotoxicity on human cells. Biomaterials. 2003;24(22):4057–61.PubMedCrossRef
9.
Zurück zum Zitat Tan IY, Agid RF, Willinsky RA. Recanalisation rates after endovascular coil embolization in a cohort of matched ruptured and unruptured cerebral aneurysms. Interv Neuroradiol. 2011;17(1):27–35.PubMedCentralPubMed Tan IY, Agid RF, Willinsky RA. Recanalisation rates after endovascular coil embolization in a cohort of matched ruptured and unruptured cerebral aneurysms. Interv Neuroradiol. 2011;17(1):27–35.PubMedCentralPubMed
10.
Zurück zum Zitat Kole MK, Pelz DM, Kalapos P, Lee DH, Gulka IB, Lownie SP. Endovascular coil embolization of intracranial aneurysms: important factors related to rates and outcomes of incomplete occlusion. J Neurosurg. 2005;102(4):607–15. doi:10.3171/jns.2005.102.4.0607.PubMedCrossRef Kole MK, Pelz DM, Kalapos P, Lee DH, Gulka IB, Lownie SP. Endovascular coil embolization of intracranial aneurysms: important factors related to rates and outcomes of incomplete occlusion. J Neurosurg. 2005;102(4):607–15. doi:10.3171/jns.2005.102.4.0607.PubMedCrossRef
11.
Zurück zum Zitat Mawad ME, Mawad JK, Cartwright J Jr., Gokaslan Z. Long-term histopathologic changes in canine aneurysms embolised with Guglielmi detachable coils. AJNR Am J Neuroradiol. 1995;16(1):7–13.PubMed Mawad ME, Mawad JK, Cartwright J Jr., Gokaslan Z. Long-term histopathologic changes in canine aneurysms embolised with Guglielmi detachable coils. AJNR Am J Neuroradiol. 1995;16(1):7–13.PubMed
12.
Zurück zum Zitat Reul J, Weis J, Spetzger U, Konert T, Fricke C, Thron A. Long-term angiographic and histopathologic findings in experimental aneurysms of the carotid bifurcation embolised with platinum and tungsten coils. AJNR Am J Neuroradiol. 1997;18(1):35–42.PubMed Reul J, Weis J, Spetzger U, Konert T, Fricke C, Thron A. Long-term angiographic and histopathologic findings in experimental aneurysms of the carotid bifurcation embolised with platinum and tungsten coils. AJNR Am J Neuroradiol. 1997;18(1):35–42.PubMed
Metadaten
Titel
Tungsten Coil Disappearance and SAH Recurrence 12 Years After Endovascular Embolisation

verfasst von
Ding Ya-Suo
Lin Yu-Chang
Publikationsdatum
01.06.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Neuroradiology / Ausgabe 2/2014
Print ISSN: 1869-1439
Elektronische ISSN: 1869-1447
DOI
https://doi.org/10.1007/s00062-013-0220-3

Weitere Artikel der Ausgabe 2/2014

Clinical Neuroradiology 2/2014 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.