Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 10/2010

01.10.2010 | Orthopaedic Surgery

Two-stage revision surgery for hip prosthesis infection using antibiotic-loaded porous hydroxyapatite blocks

verfasst von: Iori Takigami, Yoshiki Ito, Daichi Ishimaru, Hiroyasu Ogawa, Nobuyuki Mori, Takashi Shimizu, Nobuo Terabayashi, Katsuji Shimizu

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 10/2010

Einloggen, um Zugang zu erhalten

Abstract

Background

Infection of a hip prosthesis is one of the most severe complications encountered in orthopedic practice. Two-stage reconstruction using an antibiotic-impregnated cement spacer has become a popular procedure for the treatment of this condition. However, there are some disadvantages with the use of antibiotic-loaded cement, including low biocompatibility, a very low release ratio, and the possibility of thermal damage to the antibiotic. We have developed an effective drug delivery system for osteomyelitis in which porous hydroxyapatite (HA) blocks are loaded with an antibiotic by the vacuum method. We report here a modification of this delivery system applied for the first stage of two-stage reconstruction surgery against infected hip prosthesis.

Patients and methods

Eight consecutive patients who developed hip prosthesis infection underwent two-stage revision total hip arthroplasty (THA) using antibiotic-loaded porous HA blocks prepared by the vacuum method. Thorough debridement and insertion of antibiotic-loaded HA blocks was performed in the first stage, followed by conversion to THA after eradication of infection in the second stage.

Results

The mean interval between the stages was 16.8 weeks. There were no complications related to the use of the antibiotic-loaded HA blocks. The patients were followed up for an average of 49 months with no evidence of recurrent infection. The mean Japanese Orthopedic Association hip score improved from 45.1 before surgery to 79.6 at the latest follow-up.

Interpretation

This simple approach utilizing antibiotic-impregnated HA blocks prepared by the vacuum method is considered to be effective for treatment of hip prosthesis infection.
Literatur
1.
Zurück zum Zitat Salvati EA, Gonzalez Della Valle A, Masri BA, Duncan CP (2003) The infected total hip arthroplasty. Instr Course Lect 52:223–245PubMed Salvati EA, Gonzalez Della Valle A, Masri BA, Duncan CP (2003) The infected total hip arthroplasty. Instr Course Lect 52:223–245PubMed
2.
Zurück zum Zitat Hanssen AD, Rand JA (1999) Evaluation and treatment of infection at the site of a total hip or knee arthroplasty. Instr Course Lect 48:111–122PubMed Hanssen AD, Rand JA (1999) Evaluation and treatment of infection at the site of a total hip or knee arthroplasty. Instr Course Lect 48:111–122PubMed
3.
Zurück zum Zitat Crockarell JR, Hanssen AD, Osmon DR, Morrey BF (1998) Treatment of infection with debridement and retention of the components following hip arthroplasty. J Bone Joint Surg Am 80:1306–1313PubMed Crockarell JR, Hanssen AD, Osmon DR, Morrey BF (1998) Treatment of infection with debridement and retention of the components following hip arthroplasty. J Bone Joint Surg Am 80:1306–1313PubMed
4.
Zurück zum Zitat Tsukayama DT, Estrada R, Gustilo RB (1996) Infection after total hip arthroplasty. A study of the treatment of one hundred and six infections. J Bone Joint Surg Am 78:512–523PubMed Tsukayama DT, Estrada R, Gustilo RB (1996) Infection after total hip arthroplasty. A study of the treatment of one hundred and six infections. J Bone Joint Surg Am 78:512–523PubMed
5.
Zurück zum Zitat Moyad TF, Thornhill T, Estok D (2008) Evaluation and management of the infected total hip and knee. Orthopedics 31:581–588 (quiz 589–590)CrossRefPubMed Moyad TF, Thornhill T, Estok D (2008) Evaluation and management of the infected total hip and knee. Orthopedics 31:581–588 (quiz 589–590)CrossRefPubMed
6.
Zurück zum Zitat Hsieh PH, Chen LH, Chen CH, Lee MS, Yang WE, Shih CH (2004) Two-stage revision hip arthroplasty for infection with a custom-made, antibiotic-loaded, cement prosthesis as an interim spacer. J Trauma 56:1247–1252CrossRefPubMed Hsieh PH, Chen LH, Chen CH, Lee MS, Yang WE, Shih CH (2004) Two-stage revision hip arthroplasty for infection with a custom-made, antibiotic-loaded, cement prosthesis as an interim spacer. J Trauma 56:1247–1252CrossRefPubMed
7.
Zurück zum Zitat Diwanji SR, Kong IK, Park YH, Cho SG, Song EK, Yoon TR (2008) Two-stage reconstruction of infected hip joints. J Arthroplasty 23:656–661CrossRefPubMed Diwanji SR, Kong IK, Park YH, Cho SG, Song EK, Yoon TR (2008) Two-stage reconstruction of infected hip joints. J Arthroplasty 23:656–661CrossRefPubMed
8.
Zurück zum Zitat Cui Q, Mihalko WM, Shields JS, Ries M, Saleh KJ (2007) Antibiotic-impregnated cement spacers for the treatment of infection associated with total hip or knee arthroplasty. J Bone Joint Surg Am 89:871–882CrossRefPubMed Cui Q, Mihalko WM, Shields JS, Ries M, Saleh KJ (2007) Antibiotic-impregnated cement spacers for the treatment of infection associated with total hip or knee arthroplasty. J Bone Joint Surg Am 89:871–882CrossRefPubMed
9.
Zurück zum Zitat Anagnostakos K, Furst O, Kelm J (2006) Antibiotic-impregnated PMMA hip spacers: current status. Acta Orthop 77:628–637CrossRefPubMed Anagnostakos K, Furst O, Kelm J (2006) Antibiotic-impregnated PMMA hip spacers: current status. Acta Orthop 77:628–637CrossRefPubMed
10.
Zurück zum Zitat Takahira N, Itoman M, Higashi K, Uchiyama K, Miyabe M, Naruse K (2003) Treatment outcome of two-stage revision total hip arthroplasty for infected hip arthroplasty using antibiotic-impregnated cement spacer. J Orthop Sci 8:26–31CrossRefPubMed Takahira N, Itoman M, Higashi K, Uchiyama K, Miyabe M, Naruse K (2003) Treatment outcome of two-stage revision total hip arthroplasty for infected hip arthroplasty using antibiotic-impregnated cement spacer. J Orthop Sci 8:26–31CrossRefPubMed
11.
Zurück zum Zitat Leunig M, Chosa E, Speck M, Ganz R (1998) A cement spacer for two-stage revision of infected implants of the hip joint. Int Orthop 22:209–214CrossRefPubMed Leunig M, Chosa E, Speck M, Ganz R (1998) A cement spacer for two-stage revision of infected implants of the hip joint. Int Orthop 22:209–214CrossRefPubMed
12.
Zurück zum Zitat Younger AS, Duncan CP, Masri BA, McGraw RW (1997) The outcome of two-stage arthroplasty using a custom-made interval spacer to treat the infected hip. J Arthroplasty 12:615–623CrossRefPubMed Younger AS, Duncan CP, Masri BA, McGraw RW (1997) The outcome of two-stage arthroplasty using a custom-made interval spacer to treat the infected hip. J Arthroplasty 12:615–623CrossRefPubMed
13.
Zurück zum Zitat Magnan B, Regis D, Biscaglia R, Bartolozzi P (2001) Preformed acrylic bone cement spacer loaded with antibiotics: use of two-stage procedure in 10 patients because of infected hips after total replacement. Acta Orthop Scand 72:591–594CrossRefPubMed Magnan B, Regis D, Biscaglia R, Bartolozzi P (2001) Preformed acrylic bone cement spacer loaded with antibiotics: use of two-stage procedure in 10 patients because of infected hips after total replacement. Acta Orthop Scand 72:591–594CrossRefPubMed
14.
Zurück zum Zitat Yamamoto K, Miyagawa N, Masaoka T, Katori Y, Shishido T, Imakiire A (2003) Clinical effectiveness of antibiotic-impregnated cement spacers for the treatment of infected implants of the hip joint. J Orthop Sci 8:823–828CrossRefPubMed Yamamoto K, Miyagawa N, Masaoka T, Katori Y, Shishido T, Imakiire A (2003) Clinical effectiveness of antibiotic-impregnated cement spacers for the treatment of infected implants of the hip joint. J Orthop Sci 8:823–828CrossRefPubMed
15.
Zurück zum Zitat Duncan CP, Beauchamp C (1993) A temporary antibiotic-loaded joint replacement system for management of complex infections involving the hip. Orthop Clin North Am 24:751–759PubMed Duncan CP, Beauchamp C (1993) A temporary antibiotic-loaded joint replacement system for management of complex infections involving the hip. Orthop Clin North Am 24:751–759PubMed
16.
Zurück zum Zitat Hoff SF, Fitzgerald RH Jr, Kelly PJ (1981) The depot administration of penicillin G and gentamicin in acrylic bone cement. J Bone Joint Surg Am 63:798–804PubMed Hoff SF, Fitzgerald RH Jr, Kelly PJ (1981) The depot administration of penicillin G and gentamicin in acrylic bone cement. J Bone Joint Surg Am 63:798–804PubMed
17.
Zurück zum Zitat Cerretani D, Giorgi G, Fornara P, Bocchi L, Neri L, Ceffa R, Ghisellini F, Ritter MA (2002) The in vitro elution characteristics of vancomycin combined with imipenem-cilastatin in acrylic bone-cements: a pharmacokinetic study. J Arthroplasty 17:619–626CrossRefPubMed Cerretani D, Giorgi G, Fornara P, Bocchi L, Neri L, Ceffa R, Ghisellini F, Ritter MA (2002) The in vitro elution characteristics of vancomycin combined with imipenem-cilastatin in acrylic bone-cements: a pharmacokinetic study. J Arthroplasty 17:619–626CrossRefPubMed
18.
Zurück zum Zitat Itokazu M, Aoki T, Nonomura H, Nishimoto Y, Itoh Y (1998) Antibiotic-loaded porous hydroxyapatite blocks for the treatment of osteomyelitis and postoperative infection. A preliminary report. Bull Hosp Jt Dis 57:125–129PubMed Itokazu M, Aoki T, Nonomura H, Nishimoto Y, Itoh Y (1998) Antibiotic-loaded porous hydroxyapatite blocks for the treatment of osteomyelitis and postoperative infection. A preliminary report. Bull Hosp Jt Dis 57:125–129PubMed
19.
Zurück zum Zitat Itokazu M, Esaki M, Yamamoto K, Tanemori T, Kasai T (1999) Local drug delivery system using ceramics: vacuum method for impregnating a chemotherapeutic agent into a porous hydroxyapatite block. J Mater Sci Mater Med 10:249–252CrossRefPubMed Itokazu M, Esaki M, Yamamoto K, Tanemori T, Kasai T (1999) Local drug delivery system using ceramics: vacuum method for impregnating a chemotherapeutic agent into a porous hydroxyapatite block. J Mater Sci Mater Med 10:249–252CrossRefPubMed
20.
Zurück zum Zitat Itokazu M, Matsunaga T, Kumazawa S, Yang W (1995) A novel drug delivery system for osteomyelitis using porous hydroxyapatite blocks loaded by centrifugation. J Appl Biomater 6:167–169CrossRefPubMed Itokazu M, Matsunaga T, Kumazawa S, Yang W (1995) A novel drug delivery system for osteomyelitis using porous hydroxyapatite blocks loaded by centrifugation. J Appl Biomater 6:167–169CrossRefPubMed
21.
Zurück zum Zitat Itokazu M, Yang W, Aoki T, Ohara A, Kato N (1998) Synthesis of antibiotic-loaded interporous hydroxyapatite blocks by vacuum method and in vitro drug release testing. Biomaterials 19:817–819CrossRefPubMed Itokazu M, Yang W, Aoki T, Ohara A, Kato N (1998) Synthesis of antibiotic-loaded interporous hydroxyapatite blocks by vacuum method and in vitro drug release testing. Biomaterials 19:817–819CrossRefPubMed
22.
Zurück zum Zitat Itokazu M, Itoh Y, Fukuta M, Miyamoto K, Ohara A, Oshima K, Nishimoto Y, Ohno T, Kasai T, Shimizu K (1999) Treatment of osteomyelitis by using antibiotic-loaded porous ceramics. Bioceramics 12:3–6 Itokazu M, Itoh Y, Fukuta M, Miyamoto K, Ohara A, Oshima K, Nishimoto Y, Ohno T, Kasai T, Shimizu K (1999) Treatment of osteomyelitis by using antibiotic-loaded porous ceramics. Bioceramics 12:3–6
23.
Zurück zum Zitat Matsumoto K, Itokazu M, Uemura S, Takigami I, Naganawa T, Shimizu K (2007) Successful joint arthroplasty after treatment of destructive MRSA arthritis of the knee using antibiotic-loaded hydroxyapatite blocks: a case report. Arch Orthop Trauma Surg 127:47–50CrossRefPubMed Matsumoto K, Itokazu M, Uemura S, Takigami I, Naganawa T, Shimizu K (2007) Successful joint arthroplasty after treatment of destructive MRSA arthritis of the knee using antibiotic-loaded hydroxyapatite blocks: a case report. Arch Orthop Trauma Surg 127:47–50CrossRefPubMed
24.
Zurück zum Zitat Tanaka S (1978) Surface replacement of the hip joint. Clin Orthop Relat Res 134:75–79 Tanaka S (1978) Surface replacement of the hip joint. Clin Orthop Relat Res 134:75–79
25.
Zurück zum Zitat Athanasou NA, Pandey R, de Steiger R, Crook D, Smith PM (1995) Diagnosis of infection by frozen section during revision arthroplasty. J Bone Joint Surg Br 77:28–33PubMed Athanasou NA, Pandey R, de Steiger R, Crook D, Smith PM (1995) Diagnosis of infection by frozen section during revision arthroplasty. J Bone Joint Surg Br 77:28–33PubMed
26.
Zurück zum Zitat Takigami I, Itokazu M, Itoh Y, Matsumoto K, Yamamoto T, Shimizu K (2008) Limb-length measurement in total hip arthroplasty using a calipers dual pin retractor. Bull NYU Hosp Jt Dis 66:107–110PubMed Takigami I, Itokazu M, Itoh Y, Matsumoto K, Yamamoto T, Shimizu K (2008) Limb-length measurement in total hip arthroplasty using a calipers dual pin retractor. Bull NYU Hosp Jt Dis 66:107–110PubMed
27.
Zurück zum Zitat Itokazu M, Matsunaga T, Ishii M, Kusakabe H, Wyni Y (1996) Use of arthroscopy and interporous hydroxyapatite as a bone graft substitute in tibial plateau fractures. Arch Orthop Trauma Surg 115:45–48CrossRefPubMed Itokazu M, Matsunaga T, Ishii M, Kusakabe H, Wyni Y (1996) Use of arthroscopy and interporous hydroxyapatite as a bone graft substitute in tibial plateau fractures. Arch Orthop Trauma Surg 115:45–48CrossRefPubMed
28.
Zurück zum Zitat Shinto Y, Uchida A, Korkusuz F, Araki N, Ono K (1992) Calcium hydroxyapatite ceramic used as a delivery system for antibiotics. J Bone Joint Surg Br 74:600–604PubMed Shinto Y, Uchida A, Korkusuz F, Araki N, Ono K (1992) Calcium hydroxyapatite ceramic used as a delivery system for antibiotics. J Bone Joint Surg Br 74:600–604PubMed
29.
Zurück zum Zitat Kawanabe K, Okada Y, Matsusue Y, Iida H, Nakamura T (1998) Treatment of osteomyelitis with antibiotic-soaked porous glass ceramic. J Bone Joint Surg Br 80:527–530CrossRefPubMed Kawanabe K, Okada Y, Matsusue Y, Iida H, Nakamura T (1998) Treatment of osteomyelitis with antibiotic-soaked porous glass ceramic. J Bone Joint Surg Br 80:527–530CrossRefPubMed
30.
Zurück zum Zitat Tomford WW, Thongphasuk J, Mankin HJ, Ferraro MJ (1990) Frozen musculoskeletal allografts. A study of the clinical incidence and causes of infection associated with their use. J Bone Joint Surg Am 72:1137–1143PubMed Tomford WW, Thongphasuk J, Mankin HJ, Ferraro MJ (1990) Frozen musculoskeletal allografts. A study of the clinical incidence and causes of infection associated with their use. J Bone Joint Surg Am 72:1137–1143PubMed
31.
Zurück zum Zitat Tanaka C, Shikata J, Ikenaga M, Takahashi M (2003) Acetabular reconstruction using a Kerboull-type acetabular reinforcement device and hydroxyapatite granules: a 3- to 8-year follow-up study. J Arthroplasty 18:719–725CrossRefPubMed Tanaka C, Shikata J, Ikenaga M, Takahashi M (2003) Acetabular reconstruction using a Kerboull-type acetabular reinforcement device and hydroxyapatite granules: a 3- to 8-year follow-up study. J Arthroplasty 18:719–725CrossRefPubMed
32.
Zurück zum Zitat Oonishi H, Iwaki Y, Kin N, Kushitani S, Murata N, Wakitani S, Imoto K (1997) Hydroxyapatite in revision of total hip replacements with massive acetabular defects: 4- to 10-year clinical results. J Bone Joint Surg Br 79:87–92CrossRefPubMed Oonishi H, Iwaki Y, Kin N, Kushitani S, Murata N, Wakitani S, Imoto K (1997) Hydroxyapatite in revision of total hip replacements with massive acetabular defects: 4- to 10-year clinical results. J Bone Joint Surg Br 79:87–92CrossRefPubMed
33.
Zurück zum Zitat Sudo A, Hasegawa M, Fukuda A, Kawamura G, Muraki M, Uchida A (2007) Acetabular reconstruction using a cementless cup and hydroxyapatite granules: 3- to 8-year clinical results. J Arthroplasty 22:828–832CrossRefPubMed Sudo A, Hasegawa M, Fukuda A, Kawamura G, Muraki M, Uchida A (2007) Acetabular reconstruction using a cementless cup and hydroxyapatite granules: 3- to 8-year clinical results. J Arthroplasty 22:828–832CrossRefPubMed
34.
Zurück zum Zitat Koo KH, Yang JW, Cho SH, Song HR, Park HB, Ha YC, Chang JD, Kim SY, Kim YH (2001) Impregnation of vancomycin, gentamicin, and cefotaxime in a cement spacer for two-stage cementless reconstruction in infected total hip arthroplasty. J Arthroplasty 16:882–892CrossRefPubMed Koo KH, Yang JW, Cho SH, Song HR, Park HB, Ha YC, Chang JD, Kim SY, Kim YH (2001) Impregnation of vancomycin, gentamicin, and cefotaxime in a cement spacer for two-stage cementless reconstruction in infected total hip arthroplasty. J Arthroplasty 16:882–892CrossRefPubMed
Metadaten
Titel
Two-stage revision surgery for hip prosthesis infection using antibiotic-loaded porous hydroxyapatite blocks
verfasst von
Iori Takigami
Yoshiki Ito
Daichi Ishimaru
Hiroyasu Ogawa
Nobuyuki Mori
Takashi Shimizu
Nobuo Terabayashi
Katsuji Shimizu
Publikationsdatum
01.10.2010
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 10/2010
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-009-0991-9

Weitere Artikel der Ausgabe 10/2010

Archives of Orthopaedic and Trauma Surgery 10/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.