Skip to main content
Erschienen in: International Journal of Legal Medicine 4/2008

01.07.2008 | Original Article

Ultra-high-resolution dual-source CT for forensic dental visualization—discrimination of ceramic and composite fillings

verfasst von: C. Jackowski, M. Wyss, A. Persson, M. Classens, M. J. Thali, A. Lussi

Erschienen in: International Journal of Legal Medicine | Ausgabe 4/2008

Einloggen, um Zugang zu erhalten

Abstract

Dental identification is the most valuable method to identify human remains in single cases with major postmortem alterations as well as in mass casualties because of its practicability and demanding reliability. Computed tomography (CT) has been investigated as a supportive tool for forensic identification and has proven to be valuable. It can also scan the dentition of a deceased within minutes. In the present study, we investigated currently used restorative materials using ultra-high-resolution dual-source CT and the extended CT scale for the purpose of a color-encoded, in scale, and artifact-free visualization in 3D volume rendering. In 122 human molars, 220 cavities with 2-, 3-, 4- and 5-mm diameter were prepared. With presently used filling materials (different composites, temporary filling materials, ceramic, and liner), these cavities were restored in six teeth for each material and cavity size (exception amalgam n = 1). The teeth were CT scanned and images reconstructed using an extended CT scale. Filling materials were analyzed in terms of resulting Hounsfield units (HU) and filling size representation within the images. Varying restorative materials showed distinctively differing radiopacities allowing for CT-data-based discrimination. Particularly, ceramic and composite fillings could be differentiated. The HU values were used to generate an updated volume-rendering preset for postmortem extended CT scale data of the dentition to easily visualize the position of restorations, the shape (in scale), and the material used which is color encoded in 3D. The results provide the scientific background for the application of 3D volume rendering to visualize the human dentition for forensic identification purposes.
Literatur
1.
Zurück zum Zitat Brogdon BG (1998) Forensic radiology. CRC Press, Boca Raton Brogdon BG (1998) Forensic radiology. CRC Press, Boca Raton
2.
Zurück zum Zitat James H (2005) Thai tsunami victim identification overview to date. J Forensic Odontostomatol 23:1–18 James H (2005) Thai tsunami victim identification overview to date. J Forensic Odontostomatol 23:1–18
3.
Zurück zum Zitat Jackowski C, Thali M, Sonnenschein M et al (2004) Visualization and quantification of air embolism structure by processing postmortem MSCT data. J Forensic Sci 49:1339–1342PubMedCrossRef Jackowski C, Thali M, Sonnenschein M et al (2004) Visualization and quantification of air embolism structure by processing postmortem MSCT data. J Forensic Sci 49:1339–1342PubMedCrossRef
4.
Zurück zum Zitat Ljung P, Winskog C, Persson A et al (2006) Full body virtual autopsies using a state-of-the-art volume rendering pipeline. IEEE Trans Vis Comput Graph 12:869–876PubMedCrossRef Ljung P, Winskog C, Persson A et al (2006) Full body virtual autopsies using a state-of-the-art volume rendering pipeline. IEEE Trans Vis Comput Graph 12:869–876PubMedCrossRef
5.
Zurück zum Zitat Rutty GN, Boyce P, Robinson CE et al (2007) The role of computed tomography in terminal ballistic analysis. Int J Legal Med 122:1–5PubMedCrossRef Rutty GN, Boyce P, Robinson CE et al (2007) The role of computed tomography in terminal ballistic analysis. Int J Legal Med 122:1–5PubMedCrossRef
6.
Zurück zum Zitat Jackowski C, Sonnenschein M, Thali MJ et al (2005) Virtopsy: postmortem minimally invasive angiography using cross section techniques–implementation and preliminary results. J Forensic Sci 50:1175–1186PubMedCrossRef Jackowski C, Sonnenschein M, Thali MJ et al (2005) Virtopsy: postmortem minimally invasive angiography using cross section techniques–implementation and preliminary results. J Forensic Sci 50:1175–1186PubMedCrossRef
7.
Zurück zum Zitat Shiotani S, Kohno M, Ohashi N et al (2004) Non-traumatic postmortem computed tomographic (PMCT) findings of the lung. Forensic Sci Int 139:39–48PubMedCrossRef Shiotani S, Kohno M, Ohashi N et al (2004) Non-traumatic postmortem computed tomographic (PMCT) findings of the lung. Forensic Sci Int 139:39–48PubMedCrossRef
8.
Zurück zum Zitat Stein KM, Bahner ML, Merkel J et al (2000) Detection of gunshot residues in routine CTs. Int J Legal Med 114:15–18PubMedCrossRef Stein KM, Bahner ML, Merkel J et al (2000) Detection of gunshot residues in routine CTs. Int J Legal Med 114:15–18PubMedCrossRef
9.
Zurück zum Zitat Hayakawa M, Yamamoto S, Motani H et al (2006) Does imaging technology overcome problems of conventional postmortem examination? A trial of computed tomography imaging for postmortem examination. Int J Legal Med 120:24–26PubMedCrossRef Hayakawa M, Yamamoto S, Motani H et al (2006) Does imaging technology overcome problems of conventional postmortem examination? A trial of computed tomography imaging for postmortem examination. Int J Legal Med 120:24–26PubMedCrossRef
10.
Zurück zum Zitat Jackowski C, Thali M, Aghayev E et al (2006) Postmortem imaging of blood and its characteristics using MSCT and MRI. Int J Legal Med 120:233–240PubMedCrossRef Jackowski C, Thali M, Aghayev E et al (2006) Postmortem imaging of blood and its characteristics using MSCT and MRI. Int J Legal Med 120:233–240PubMedCrossRef
11.
Zurück zum Zitat Sidler M, Jackowski C, Dirnhofer R et al (2007) Use of multislice computed tomography in disaster victim identification–advantages and limitations. Forensic Sci Int 169:118–128PubMedCrossRef Sidler M, Jackowski C, Dirnhofer R et al (2007) Use of multislice computed tomography in disaster victim identification–advantages and limitations. Forensic Sci Int 169:118–128PubMedCrossRef
12.
Zurück zum Zitat Dedouit F, Telmon N, Costagliola R et al (2007) New identification possibilities with postmortem multislice computed tomography. Int J Legal Med 121(6):507–510PubMedCrossRef Dedouit F, Telmon N, Costagliola R et al (2007) New identification possibilities with postmortem multislice computed tomography. Int J Legal Med 121(6):507–510PubMedCrossRef
13.
Zurück zum Zitat Tatlisumak E, Yilmaz OG, Aslan A et al (2007) Identification of unknown bodies by using CT images of frontal sinus. Forensic Sci Int 166:42–48PubMedCrossRef Tatlisumak E, Yilmaz OG, Aslan A et al (2007) Identification of unknown bodies by using CT images of frontal sinus. Forensic Sci Int 166:42–48PubMedCrossRef
14.
Zurück zum Zitat Smith DR, Limbird KG, Hoffman JM (2002) Identification of human skeletal remains by comparison of bony details of the cranium using computerized tomographic (CT) scans. J Forensic Sci 47:937–939PubMed Smith DR, Limbird KG, Hoffman JM (2002) Identification of human skeletal remains by comparison of bony details of the cranium using computerized tomographic (CT) scans. J Forensic Sci 47:937–939PubMed
15.
Zurück zum Zitat Pfaeffli M, Vock P, Dirnhofer R et al (2007) Post-mortem radiological CT identification based on classical ante-mortem X-ray examinations. Forensic Sci Int 171:111–117PubMedCrossRef Pfaeffli M, Vock P, Dirnhofer R et al (2007) Post-mortem radiological CT identification based on classical ante-mortem X-ray examinations. Forensic Sci Int 171:111–117PubMedCrossRef
16.
Zurück zum Zitat Dedouit F, Telmon N, Guilbeau-Frugier C et al (2007) Virtual autopsy and forensic identification-practical application: a report of one case. J Forensic Sci 52:960–964PubMedCrossRef Dedouit F, Telmon N, Guilbeau-Frugier C et al (2007) Virtual autopsy and forensic identification-practical application: a report of one case. J Forensic Sci 52:960–964PubMedCrossRef
17.
Zurück zum Zitat Jackowski C, Aghayev E, Sonnenschein M et al (2006) Maximum intensity projection of cranial computed tomography data for dental identification. Int J Legal Med 120:165–167PubMedCrossRef Jackowski C, Aghayev E, Sonnenschein M et al (2006) Maximum intensity projection of cranial computed tomography data for dental identification. Int J Legal Med 120:165–167PubMedCrossRef
18.
Zurück zum Zitat Thali MJ, Markwalder T, Jackowski C et al (2006) Dental CT imaging as a screening tool for dental profiling: advantages and limitations. J Forensic Sci 51:113–119PubMedCrossRef Thali MJ, Markwalder T, Jackowski C et al (2006) Dental CT imaging as a screening tool for dental profiling: advantages and limitations. J Forensic Sci 51:113–119PubMedCrossRef
19.
Zurück zum Zitat Jackowski C, Lussi A, Classens M et al (2006) Extended CT scale overcomes restoration caused streak artifacts for dental identification in CT–3D color encoded automatic discrimination of dental restorations. J Comput Assist Tomogr 30:510–513PubMedCrossRef Jackowski C, Lussi A, Classens M et al (2006) Extended CT scale overcomes restoration caused streak artifacts for dental identification in CT–3D color encoded automatic discrimination of dental restorations. J Comput Assist Tomogr 30:510–513PubMedCrossRef
20.
Zurück zum Zitat Eisenburger M, Hughes J, West NX et al (2001) The use of ultrasonication to study remineralisation of eroded enamel. Caries Res 35:61–66PubMedCrossRef Eisenburger M, Hughes J, West NX et al (2001) The use of ultrasonication to study remineralisation of eroded enamel. Caries Res 35:61–66PubMedCrossRef
Metadaten
Titel
Ultra-high-resolution dual-source CT for forensic dental visualization—discrimination of ceramic and composite fillings
verfasst von
C. Jackowski
M. Wyss
A. Persson
M. Classens
M. J. Thali
A. Lussi
Publikationsdatum
01.07.2008
Verlag
Springer-Verlag
Erschienen in
International Journal of Legal Medicine / Ausgabe 4/2008
Print ISSN: 0937-9827
Elektronische ISSN: 1437-1596
DOI
https://doi.org/10.1007/s00414-008-0224-8

Weitere Artikel der Ausgabe 4/2008

International Journal of Legal Medicine 4/2008 Zur Ausgabe

Neu im Fachgebiet Rechtsmedizin