Skip to main content
Erschienen in: Endocrine 1/2017

15.05.2017 | Original Article

Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors

verfasst von: In Hye Chae, Eun-Kyung Kim, Hee Jung Moon, Jung Hyun Yoon, Vivian Y. Park, Jin Young Kwak

Erschienen in: Endocrine | Ausgabe 1/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma.

Methods

A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed.

Results

Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001).

Conclusion

Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.
Literatur
1.
Zurück zum Zitat B.R.M. Haugen, E.K. Alexander, K.C. Bible, G. Doherty, S.J. Mandel, Y.E. Nikiforov, F. Pacini, G. Randolph, A. Sawka, M. Schlumberger, K.G. Schuff, S.I. Sherman, J.A. Sosa, D. Steward, R.M.M. Tuttle, L. Wartofsky, 2015 American thyroid association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer. Thyroid 26(1), 1–133 (2015)CrossRef B.R.M. Haugen, E.K. Alexander, K.C. Bible, G. Doherty, S.J. Mandel, Y.E. Nikiforov, F. Pacini, G. Randolph, A. Sawka, M. Schlumberger, K.G. Schuff, S.I. Sherman, J.A. Sosa, D. Steward, R.M.M. Tuttle, L. Wartofsky, 2015 American thyroid association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer. Thyroid 26(1), 1–133 (2015)CrossRef
2.
Zurück zum Zitat J.H. Yoon, H.J. Moon, E.K. Kim, J.Y. Kwak, Inadequate cytology in thyroid nodules: should we repeat aspiration or follow-up? Ann. Surg. Oncol. 18(5), 1282–1289 (2011)CrossRef J.H. Yoon, H.J. Moon, E.K. Kim, J.Y. Kwak, Inadequate cytology in thyroid nodules: should we repeat aspiration or follow-up? Ann. Surg. Oncol. 18(5), 1282–1289 (2011)CrossRef
3.
Zurück zum Zitat J.H. Yoon, E.K. Kim, J.Y. Kwak, H.J. Moon, Effectiveness and limitations of core needle biopsy in the diagnosis of thyroid nodules: review of current literature. J. Pathol. Transl. Med. 49(3), 230–235 (2015)CrossRef J.H. Yoon, E.K. Kim, J.Y. Kwak, H.J. Moon, Effectiveness and limitations of core needle biopsy in the diagnosis of thyroid nodules: review of current literature. J. Pathol. Transl. Med. 49(3), 230–235 (2015)CrossRef
4.
Zurück zum Zitat A.C. Nachiappan, Z.A. Metwalli, B.S. Hailey, R.A. Patel, M.L. Ostrowski, D.M. Wynne, The thyroid: review of imaging features and biopsy techniques with radiologic-pathologic correlation. Radiographics 34(2), 276–293 (2014)CrossRef A.C. Nachiappan, Z.A. Metwalli, B.S. Hailey, R.A. Patel, M.L. Ostrowski, D.M. Wynne, The thyroid: review of imaging features and biopsy techniques with radiologic-pathologic correlation. Radiographics 34(2), 276–293 (2014)CrossRef
5.
Zurück zum Zitat H. Gharib, E. Papini, R. Paschke, D.S. Duick, R. Valcavi, L. Hegedus, P. Vitti, American association of clinical endocrinologists, associazione medici endocrinologi, and European thyroid association medical guidelines for clinical practice for the diagnosis and management of thyroid nodules: executive summary of recommendations. J. Endocrinol. Invest. 33(5 Suppl), 51–56 (2010)PubMed H. Gharib, E. Papini, R. Paschke, D.S. Duick, R. Valcavi, L. Hegedus, P. Vitti, American association of clinical endocrinologists, associazione medici endocrinologi, and European thyroid association medical guidelines for clinical practice for the diagnosis and management of thyroid nodules: executive summary of recommendations. J. Endocrinol. Invest. 33(5 Suppl), 51–56 (2010)PubMed
6.
Zurück zum Zitat Y.H. Kim, H.J. Kwon, E.K. Kim, J.Y. Kwak, H.J. Moon, J.H. Yoon, Applying ultrasound-guided core needle biopsy for diagnosis of thyroid masses: preliminary results from a single institution. J. Ultrasound. Med. 34(10), 1801–1808 (2015)CrossRef Y.H. Kim, H.J. Kwon, E.K. Kim, J.Y. Kwak, H.J. Moon, J.H. Yoon, Applying ultrasound-guided core needle biopsy for diagnosis of thyroid masses: preliminary results from a single institution. J. Ultrasound. Med. 34(10), 1801–1808 (2015)CrossRef
7.
Zurück zum Zitat E. Novoa, N. Gurtler, A. Arnoux, M. Kraft, Role of ultrasound-guided core-needle biopsy in the assessment of head and neck lesions: a meta-analysis and systematic review of the literature. Head Neck 34(10), 1497–1503 (2012)CrossRef E. Novoa, N. Gurtler, A. Arnoux, M. Kraft, Role of ultrasound-guided core-needle biopsy in the assessment of head and neck lesions: a meta-analysis and systematic review of the literature. Head Neck 34(10), 1497–1503 (2012)CrossRef
8.
Zurück zum Zitat B.T. Chen, A.B. Jain, A. Dagis, P. Chu, L. Vora, E. Maghami, B. Salehian, Comparison of the efficacy and safety of ultrasound-guided core needle biopsy versus fine-needle aspiration for evaluating thyroid nodules. Endocr. Pract. 21(2), 128–135 (2015)CrossRef B.T. Chen, A.B. Jain, A. Dagis, P. Chu, L. Vora, E. Maghami, B. Salehian, Comparison of the efficacy and safety of ultrasound-guided core needle biopsy versus fine-needle aspiration for evaluating thyroid nodules. Endocr. Pract. 21(2), 128–135 (2015)CrossRef
9.
Zurück zum Zitat E.J. Ha, J.H. Baek, J.H. Lee, J.K. Kim, Y.J. Choi, T.Y. Sung, T.Y. Kim, Complications following US-guided core-needle biopsy for thyroid lesions: a retrospective study of 6,169 consecutive patients with 6,687 thyroid nodules. Eur. Radiol. 27(3), 1–9 (2016) E.J. Ha, J.H. Baek, J.H. Lee, J.K. Kim, Y.J. Choi, T.Y. Sung, T.Y. Kim, Complications following US-guided core-needle biopsy for thyroid lesions: a retrospective study of 6,169 consecutive patients with 6,687 thyroid nodules. Eur. Radiol. 27(3), 1–9 (2016)
10.
Zurück zum Zitat T.K. Khoo, C.H. Baker, J. Hallanger-Johnson, A.M. Tom, C.S. Grant, C.C. Reading, T.J. Sebo, J.C. Morris, 3rd: comparison of ultrasound-guided fine-needle aspiration biopsy with core-needle biopsy in the evaluation of thyroid nodules. Endocr. Pract. 14(4), 426–431 (2008)CrossRef T.K. Khoo, C.H. Baker, J. Hallanger-Johnson, A.M. Tom, C.S. Grant, C.C. Reading, T.J. Sebo, J.C. Morris, 3rd: comparison of ultrasound-guided fine-needle aspiration biopsy with core-needle biopsy in the evaluation of thyroid nodules. Endocr. Pract. 14(4), 426–431 (2008)CrossRef
11.
Zurück zum Zitat M. Bergeron, D. Beaudoin, Simple core-needle biopsy for thyroid nodule, complicated tinnitus. Eur. Thyroid. J. 3(2), 130–133 (2014)CrossRef M. Bergeron, D. Beaudoin, Simple core-needle biopsy for thyroid nodule, complicated tinnitus. Eur. Thyroid. J. 3(2), 130–133 (2014)CrossRef
12.
Zurück zum Zitat S.A. Polyzos, A.D. Anastasilakis, Clinical complications following thyroid fine-needle biopsy: a systematic review. Clin. Endocrinol. 71(2), 157–165 (2009)CrossRef S.A. Polyzos, A.D. Anastasilakis, Clinical complications following thyroid fine-needle biopsy: a systematic review. Clin. Endocrinol. 71(2), 157–165 (2009)CrossRef
13.
Zurück zum Zitat J.N. Harvey, D. Parker, P. De, R.K. Shrimali, M. Otter, Sonographically guided core biopsy in the assessment of thyroid nodules. J. Clin. Ultrasound. 33(2), 57–62 (2005)CrossRef J.N. Harvey, D. Parker, P. De, R.K. Shrimali, M. Otter, Sonographically guided core biopsy in the assessment of thyroid nodules. J. Clin. Ultrasound. 33(2), 57–62 (2005)CrossRef
14.
Zurück zum Zitat K.A. Newkirk, M.D. Ringel, J. Jelinek, A. Mark, L. Wartofsky, Z.E. Deeb, R.B. Sessions, K.D. Burman, Ultrasound-guided fine-needle aspiration and thyroid disease. Otolaryngol. Head Neck Surg. 123(6), 700–705 (2000)CrossRef K.A. Newkirk, M.D. Ringel, J. Jelinek, A. Mark, L. Wartofsky, Z.E. Deeb, R.B. Sessions, K.D. Burman, Ultrasound-guided fine-needle aspiration and thyroid disease. Otolaryngol. Head Neck Surg. 123(6), 700–705 (2000)CrossRef
15.
Zurück zum Zitat M. Braga, T.C. Cavalcanti, L.M. Collaco, H. Graf, Efficacy of ultrasound-guided fine-needle aspiration biopsy in the diagnosis of complex thyroid nodules. J. Clin. Endocrinol. Metab. 86(9), 4089–4091 (2001)CrossRef M. Braga, T.C. Cavalcanti, L.M. Collaco, H. Graf, Efficacy of ultrasound-guided fine-needle aspiration biopsy in the diagnosis of complex thyroid nodules. J. Clin. Endocrinol. Metab. 86(9), 4089–4091 (2001)CrossRef
16.
Zurück zum Zitat J.L. Roh, Intrathyroid hemorrhage and acute upper airway obstruction after fine needle aspiration of the thyroid gland. Laryngoscope 116(1), 154–156 (2006)CrossRef J.L. Roh, Intrathyroid hemorrhage and acute upper airway obstruction after fine needle aspiration of the thyroid gland. Laryngoscope 116(1), 154–156 (2006)CrossRef
17.
Zurück zum Zitat T. Hor, S.W. Lahiri, Bilateral thyroid hematomas after fine-needle aspiration causing acute airway obstruction. Thyroid 18(5), 567–569 (2008)CrossRef T. Hor, S.W. Lahiri, Bilateral thyroid hematomas after fine-needle aspiration causing acute airway obstruction. Thyroid 18(5), 567–569 (2008)CrossRef
18.
Zurück zum Zitat E.K. Kim, C.S. Park, W.Y. Chung, K.K. Oh, D.I. Kim, J.T. Lee, H.S. Yoo, New sonographic criteria for recommending fine-needle aspiration biopsy of nonpalpable solid nodules of the thyroid. Am. J. Roentgenol. 178(3), 687–691 (2002)CrossRef E.K. Kim, C.S. Park, W.Y. Chung, K.K. Oh, D.I. Kim, J.T. Lee, H.S. Yoo, New sonographic criteria for recommending fine-needle aspiration biopsy of nonpalpable solid nodules of the thyroid. Am. J. Roentgenol. 178(3), 687–691 (2002)CrossRef
19.
Zurück zum Zitat D.G. Na, J.-h Kim, J.Y. Sung, J.H. Baek, K.C. Jung, H. Lee, H. Yoo, Core-needle biopsy is more useful than repeat fine-needle aspiration in thyroid nodules read as nondiagnostic or atypia of undetermined significance by the Bethesda system for reporting thyroid cytopathology. Thyroid 22(5), 468–475 (2012)CrossRef D.G. Na, J.-h Kim, J.Y. Sung, J.H. Baek, K.C. Jung, H. Lee, H. Yoo, Core-needle biopsy is more useful than repeat fine-needle aspiration in thyroid nodules read as nondiagnostic or atypia of undetermined significance by the Bethesda system for reporting thyroid cytopathology. Thyroid 22(5), 468–475 (2012)CrossRef
20.
Zurück zum Zitat J.S. Pyo, J.H. Sohn, G. Kang, Core needle biopsy is a more conclusive follow-up method than repeat fine needle aspiration for thyroid nodules with initially inconclusive results: a systematic review and meta-analysis. J. Pathol. Transl. Med. 50(3), 217–224 (2016)CrossRef J.S. Pyo, J.H. Sohn, G. Kang, Core needle biopsy is a more conclusive follow-up method than repeat fine needle aspiration for thyroid nodules with initially inconclusive results: a systematic review and meta-analysis. J. Pathol. Transl. Med. 50(3), 217–224 (2016)CrossRef
21.
Zurück zum Zitat J.Y. Sung, D.G. Na, K.S. Kim, H. Yoo, H. Lee, J.H. Kim, J.H. Baek, Diagnostic accuracy of fine-needle aspiration versus core-needle biopsy for the diagnosis of thyroid malignancy in a clinical cohort. Eur. Radiol. 22(7), 1564–1572 (2012)CrossRef J.Y. Sung, D.G. Na, K.S. Kim, H. Yoo, H. Lee, J.H. Kim, J.H. Baek, Diagnostic accuracy of fine-needle aspiration versus core-needle biopsy for the diagnosis of thyroid malignancy in a clinical cohort. Eur. Radiol. 22(7), 1564–1572 (2012)CrossRef
22.
Zurück zum Zitat B. Al Knawy, M. Shiffman, Percutaneous liver biopsy in clinical practice. Liver Int. 27(9), 1166–1173 (2007)CrossRef B. Al Knawy, M. Shiffman, Percutaneous liver biopsy in clinical practice. Liver Int. 27(9), 1166–1173 (2007)CrossRef
23.
Zurück zum Zitat G. Mitsuyoshi, N. Naito, A. Kawai, T. Kunisada, A. Yoshida, H. Yanai, S. Dendo, T. Yoshino, S. Kanazawa, T. Ozaki, Accurate diagnosis of musculoskeletal lesions by core needle biopsy. J. Surg. Oncol. 94(1), 21–27 (2006)CrossRef G. Mitsuyoshi, N. Naito, A. Kawai, T. Kunisada, A. Yoshida, H. Yanai, S. Dendo, T. Yoshino, S. Kanazawa, T. Ozaki, Accurate diagnosis of musculoskeletal lesions by core needle biopsy. J. Surg. Oncol. 94(1), 21–27 (2006)CrossRef
24.
Zurück zum Zitat W. Bruening, J. Fontanarosa, K. Tipton, J.R. Treadwell, J. Launders, K. Schoelles, Systematic review: comparative effectiveness of core-needle and open surgical biopsy to diagnose breast lesions. Ann. Intern. Med. 152(4), 238–246 (2010)CrossRef W. Bruening, J. Fontanarosa, K. Tipton, J.R. Treadwell, J. Launders, K. Schoelles, Systematic review: comparative effectiveness of core-needle and open surgical biopsy to diagnose breast lesions. Ann. Intern. Med. 152(4), 238–246 (2010)CrossRef
25.
Zurück zum Zitat S.Y. Kim, H.S. Lee, J. Moon, E.K. Kim, H.J. Moon, J.H. Yoon, J.Y. Kwak, Fine-needle aspiration versus core needle biopsy for diagnosis of thyroid malignancy and neoplasm: a matched cohort study. Eur. Radiol. 27(2), 801–811 (2017)CrossRef S.Y. Kim, H.S. Lee, J. Moon, E.K. Kim, H.J. Moon, J.H. Yoon, J.Y. Kwak, Fine-needle aspiration versus core needle biopsy for diagnosis of thyroid malignancy and neoplasm: a matched cohort study. Eur. Radiol. 27(2), 801–811 (2017)CrossRef
26.
Zurück zum Zitat N. Nasrollah, P. Trimboli, F. Rossi, S. Amendola, L. Guidobaldi, C. Ventura, R. Maglio, G. Nigri, F. Romanelli, S. Valabrega, Patient’s comfort with and tolerability of thyroid core needle biopsy. Endocrine 45(1), 79–83 (2014)CrossRef N. Nasrollah, P. Trimboli, F. Rossi, S. Amendola, L. Guidobaldi, C. Ventura, R. Maglio, G. Nigri, F. Romanelli, S. Valabrega, Patient’s comfort with and tolerability of thyroid core needle biopsy. Endocrine 45(1), 79–83 (2014)CrossRef
27.
Zurück zum Zitat P. Trimboli, A. Crescenzi, Thyroid core needle biopsy: taking stock of the situation. Endocrine 48(3), 779–785 (2015)CrossRef P. Trimboli, A. Crescenzi, Thyroid core needle biopsy: taking stock of the situation. Endocrine 48(3), 779–785 (2015)CrossRef
28.
Zurück zum Zitat A. Carpi, G. Rossi, A. Nicolini, G. Iervasi, M. Russo, J. Mechanick, Does large needle aspiration biopsy add pain to the thyroid nodule evaluation? PLoS One 8(3), e58016 (2013)CrossRef A. Carpi, G. Rossi, A. Nicolini, G. Iervasi, M. Russo, J. Mechanick, Does large needle aspiration biopsy add pain to the thyroid nodule evaluation? PLoS One 8(3), e58016 (2013)CrossRef
Metadaten
Titel
Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors
verfasst von
In Hye Chae
Eun-Kyung Kim
Hee Jung Moon
Jung Hyun Yoon
Vivian Y. Park
Jin Young Kwak
Publikationsdatum
15.05.2017
Verlag
Springer US
Erschienen in
Endocrine / Ausgabe 1/2017
Print ISSN: 1355-008X
Elektronische ISSN: 1559-0100
DOI
https://doi.org/10.1007/s12020-017-1319-0

Weitere Artikel der Ausgabe 1/2017

Endocrine 1/2017 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.