Skip to main content
Erschienen in: International Urogynecology Journal 5/2019

01.05.2019 | Original Article

Ultrasound visualization of sacrocolpopexy polyvinylidene fluoride meshes containing paramagnetic Fe particles compared with polypropylene mesh

verfasst von: Vered H. Eisenberg, Geertje Callewaert, Nikhil Sindhwani, Susanne Housmans, Dominique van Schoubroeck, Lior Lowenstein, Jan Deprest

Erschienen in: International Urogynecology Journal | Ausgabe 5/2019

Einloggen, um Zugang zu erhalten

Abstract

Introduction and hypothesis

Paramagnetic Fe particles can be added during synthetic mesh production to allow visibility on magnetic resonance imaging. Our aim was to evaluate whether transperineal ultrasound (TPUS) allows visualization, measurement, and characterization of polyvinylidene fluoride (PVDF mesh) containing Fe particles compared with regular polypropylene (PP) meshes used for sacrocolpopexy.

Methods

Women up to 1.5 years after laparoscopic sacrocolpopexy who were implanted with a PP or PVDF mesh underwent clinical examination and 2D, 3D, and 4D TPUS. Acquired volumes were analyzed offline for mesh position at rest and maximal Valsalva and for mesh dimensions and characteristics, with the operator blinded to group assignment. The two groups were compared.

Results

There were 17 women in the PP and 25 in the PVDF mesh group, without differences in baseline demographics. None had significant prolapse, recurrence, symptoms, or complications. On TPUS, mesh was visible in all patients both caudally (perineal) and cranially but was more echogenic in the PVDF mesh group. Mesh length from distal to proximal that was visible on TPUS was longer for PVDF mesh, for both anterior and posterior vaginal arms (all P < 0.05), and for mesh above the vaginal apex (P = 0.002). The inferior aspects of the mesh showed areas of double mesh layers, suggesting folding in 80% of women in both groups, without symptoms.

Conclusions

PVDF mesh permits clearer visualization and is seen over a longer stretch on TPUS, with longer visible mesh arms. The latter can be due to differences in operative technique, presence of microparticles, implant textile structure, or patient characteristics.
Literatur
1.
Zurück zum Zitat Lowenstein E, Ottesen B, Gimbel H. Incidence and lifetime risk of pelvic organ prolapse surgery in Denmark from 1977 to 2009. Int Urogynecol J. 2015;26:49–55.CrossRefPubMed Lowenstein E, Ottesen B, Gimbel H. Incidence and lifetime risk of pelvic organ prolapse surgery in Denmark from 1977 to 2009. Int Urogynecol J. 2015;26:49–55.CrossRefPubMed
2.
Zurück zum Zitat Wu JM, Matthews CA, Conover MM, et al. Lifetime risk of stress urinary incontinence or pelvic organ prolapse surgery. Obstet Gynecol. 2014;123:1201–6.CrossRefPubMedPubMedCentral Wu JM, Matthews CA, Conover MM, et al. Lifetime risk of stress urinary incontinence or pelvic organ prolapse surgery. Obstet Gynecol. 2014;123:1201–6.CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Smith FJ, Holman CD, Moorin RE, et al. Lifetime risk of undergoing surgery for pelvic organ prolapse. Obstet Gynecol. 2010;116:1096–100.CrossRefPubMed Smith FJ, Holman CD, Moorin RE, et al. Lifetime risk of undergoing surgery for pelvic organ prolapse. Obstet Gynecol. 2010;116:1096–100.CrossRefPubMed
4.
Zurück zum Zitat Lee D, Zimmern PE. Management of complications of mesh surgery. Curr Opin Urol. 2015;25:284–91.PubMed Lee D, Zimmern PE. Management of complications of mesh surgery. Curr Opin Urol. 2015;25:284–91.PubMed
5.
Zurück zum Zitat Zambon JP, Badlani GH. Vaginal mesh exposure presentation, evaluation, and management. Curr Urol Rep. 2016;17:65.CrossRefPubMed Zambon JP, Badlani GH. Vaginal mesh exposure presentation, evaluation, and management. Curr Urol Rep. 2016;17:65.CrossRefPubMed
6.
Zurück zum Zitat Maher C, Feiner B, Baessler K, et al. Surgical management of pelvic organ prolapse in women. Cochrane Database Syst Rev. 2013;4:CD004014. Maher C, Feiner B, Baessler K, et al. Surgical management of pelvic organ prolapse in women. Cochrane Database Syst Rev. 2013;4:CD004014.
7.
Zurück zum Zitat Nygaard I, Brubaker L, Zyczynski HM, et al. Long-term outcomes following abdominal sacrocolpopexy for pelvic organ prolapse. JAMA. 2013;309:2016–24.CrossRefPubMedPubMedCentral Nygaard I, Brubaker L, Zyczynski HM, et al. Long-term outcomes following abdominal sacrocolpopexy for pelvic organ prolapse. JAMA. 2013;309:2016–24.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Dietz HP. Ultrasound imaging of the pelvic floor. Part II: three-dimensional or volume imaging. Ultrasound Obstet Gynecol. 2004;23:615–25.CrossRefPubMed Dietz HP. Ultrasound imaging of the pelvic floor. Part II: three-dimensional or volume imaging. Ultrasound Obstet Gynecol. 2004;23:615–25.CrossRefPubMed
9.
Zurück zum Zitat Jamadar DA, Jacobson JA, Girish G, et al. Abdominal wall hernia mesh repair: sonography of mesh and common complications. J Ultrasound Med. 2008;27:907–17.CrossRefPubMed Jamadar DA, Jacobson JA, Girish G, et al. Abdominal wall hernia mesh repair: sonography of mesh and common complications. J Ultrasound Med. 2008;27:907–17.CrossRefPubMed
10.
Zurück zum Zitat Dietz HP, Mouritsen L, Ellis G, et al. Does the tension-free vaginal tape stay where you put it? Am J Obstet Gynecol. 2003;188:950–3.CrossRefPubMed Dietz HP, Mouritsen L, Ellis G, et al. Does the tension-free vaginal tape stay where you put it? Am J Obstet Gynecol. 2003;188:950–3.CrossRefPubMed
11.
Zurück zum Zitat Svabik K, Martan A, Masata J, et al. Ultrasound appearances after mesh implantation--evidence of mesh contraction or folding? Int Urogynecol J. 2011;22:529–33.CrossRefPubMed Svabik K, Martan A, Masata J, et al. Ultrasound appearances after mesh implantation--evidence of mesh contraction or folding? Int Urogynecol J. 2011;22:529–33.CrossRefPubMed
12.
Zurück zum Zitat Eisenberg VH, Steinberg M, Weiner Z, et al. Three-dimensional transperineal ultrasound for imaging mesh implants following sacrocolpopexy. Ultrasound Obstet Gynecol. 2014;43:459–65.CrossRefPubMed Eisenberg VH, Steinberg M, Weiner Z, et al. Three-dimensional transperineal ultrasound for imaging mesh implants following sacrocolpopexy. Ultrasound Obstet Gynecol. 2014;43:459–65.CrossRefPubMed
13.
Zurück zum Zitat Eisenberg VH, Steinberg M, Weiner Z, et al. Long-term follow-up of sacrocolpopexy mesh implants at two time intervals at least 1 year apart using 4D transperineal ultrasound. Ultrasound Obstet Gynecol. 2017;49:398–403.CrossRefPubMed Eisenberg VH, Steinberg M, Weiner Z, et al. Long-term follow-up of sacrocolpopexy mesh implants at two time intervals at least 1 year apart using 4D transperineal ultrasound. Ultrasound Obstet Gynecol. 2017;49:398–403.CrossRefPubMed
14.
Zurück zum Zitat Fischer T, Ladurner R, Gangkofer A, et al. Functional cine MRI of the abdomen for the assessment of implanted synthetic mesh in patients after incisional hernia repair: initial results. Eur Radiol. 2007;17:3123–9.CrossRefPubMed Fischer T, Ladurner R, Gangkofer A, et al. Functional cine MRI of the abdomen for the assessment of implanted synthetic mesh in patients after incisional hernia repair: initial results. Eur Radiol. 2007;17:3123–9.CrossRefPubMed
15.
Zurück zum Zitat Kuehnert N, Kraemer NA, Otto J, et al. In vivo MRI visualization of mesh shrinkage using surgical implants loaded with superparamagnetic iron oxides. Surg Endosc. 2012;26:1468–75.CrossRefPubMed Kuehnert N, Kraemer NA, Otto J, et al. In vivo MRI visualization of mesh shrinkage using surgical implants loaded with superparamagnetic iron oxides. Surg Endosc. 2012;26:1468–75.CrossRefPubMed
16.
Zurück zum Zitat Urbankova I, Sindhwani N, Callewaert G, et al. In vivo documentation of shape and position changes of MRI-visible mesh placed in rectovaginal septum. J Mech Behav Biomed Mater. 2017;75:379–89.CrossRef Urbankova I, Sindhwani N, Callewaert G, et al. In vivo documentation of shape and position changes of MRI-visible mesh placed in rectovaginal septum. J Mech Behav Biomed Mater. 2017;75:379–89.CrossRef
17.
Zurück zum Zitat Sindhwani N, Feola A, De Keyzer F, et al. Three-dimensional analysis of implanted magnetic-resonance-visible meshes. Int Urogynecol J. 2015;26:1459–65.CrossRefPubMed Sindhwani N, Feola A, De Keyzer F, et al. Three-dimensional analysis of implanted magnetic-resonance-visible meshes. Int Urogynecol J. 2015;26:1459–65.CrossRefPubMed
18.
Zurück zum Zitat Claerhout F, De Ridder D, Roovers JP, et al. Medium-term anatomic and functional results of laparoscopic sacrocolpopexy beyond the learning curve. Eur Urol. 2009;55:1459–67.CrossRefPubMed Claerhout F, De Ridder D, Roovers JP, et al. Medium-term anatomic and functional results of laparoscopic sacrocolpopexy beyond the learning curve. Eur Urol. 2009;55:1459–67.CrossRefPubMed
19.
Zurück zum Zitat Endo M, Feola A, Sindhwani N, et al. Mesh contraction: in vivo documentation of changes in apparent surface area utilizing meshes visible on magnetic resonance imaging in the rabbit abdominal wall model. Int Urogynecol J. 2014;25:737–43.CrossRefPubMed Endo M, Feola A, Sindhwani N, et al. Mesh contraction: in vivo documentation of changes in apparent surface area utilizing meshes visible on magnetic resonance imaging in the rabbit abdominal wall model. Int Urogynecol J. 2014;25:737–43.CrossRefPubMed
20.
Zurück zum Zitat Sommer T, Friis-Andersen H. DynaMesh(R) in the repair of laparoscopic ventral hernia: a prospective trial. Hernia. 2013;17:613–8.CrossRefPubMed Sommer T, Friis-Andersen H. DynaMesh(R) in the repair of laparoscopic ventral hernia: a prospective trial. Hernia. 2013;17:613–8.CrossRefPubMed
21.
Zurück zum Zitat Gerullis H, Klosterhalfen B, Boros M, et al. IDEAL in meshes for prolapse, urinary incontinence, and hernia repair. Surg Innov. 2013;20:502–8.CrossRefPubMed Gerullis H, Klosterhalfen B, Boros M, et al. IDEAL in meshes for prolapse, urinary incontinence, and hernia repair. Surg Innov. 2013;20:502–8.CrossRefPubMed
22.
Zurück zum Zitat Bump RC, Mattiasson A, Bo K, et al. The standardization of terminology of female pelvic organ prolapse and pelvic floor dysfunction. Am J Obstet Gynecol. 1996;175:10–7.CrossRefPubMed Bump RC, Mattiasson A, Bo K, et al. The standardization of terminology of female pelvic organ prolapse and pelvic floor dysfunction. Am J Obstet Gynecol. 1996;175:10–7.CrossRefPubMed
23.
Zurück zum Zitat Sindhwani N, Liaquat Z, Urbankova I, et al. Immediate postoperative changes in synthetic meshes - In vivo measurements. J Mech Behav Biomed Mater. 2015;55:228–35.CrossRefPubMed Sindhwani N, Liaquat Z, Urbankova I, et al. Immediate postoperative changes in synthetic meshes - In vivo measurements. J Mech Behav Biomed Mater. 2015;55:228–35.CrossRefPubMed
Metadaten
Titel
Ultrasound visualization of sacrocolpopexy polyvinylidene fluoride meshes containing paramagnetic Fe particles compared with polypropylene mesh
verfasst von
Vered H. Eisenberg
Geertje Callewaert
Nikhil Sindhwani
Susanne Housmans
Dominique van Schoubroeck
Lior Lowenstein
Jan Deprest
Publikationsdatum
01.05.2019
Verlag
Springer International Publishing
Erschienen in
International Urogynecology Journal / Ausgabe 5/2019
Print ISSN: 0937-3462
Elektronische ISSN: 1433-3023
DOI
https://doi.org/10.1007/s00192-018-3728-x

Weitere Artikel der Ausgabe 5/2019

International Urogynecology Journal 5/2019 Zur Ausgabe

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.