Abstract

Purpose

There are numerous constructs employed in the treatment of metacarpal fractures with varying degrees of success. While plate fixation commonly involves dorsal application of a bicortical non-locking plate, there has been recent exploration of other fixation options including unicortical locked plating. The purpose of this study was to evaluate the biomechanical integrity of a polyetheretherketone (PEEK) inset locking plate and, in doing so, compare it to standard plate fixation (utilizing a clinically proven bicortical non-locking titanium plate) in a simulated porcine metacarpal fracture model.

Methods

Reproducible mid-shaft fractures were created in porcine second metacarpals. The fractured specimens were reduced and plated with either a bicortical non-locking plate or a unicortical locking plate with a PEEK locking design. Constructs were then loaded to failure in the same fashion as performed to create the fracture. Peak load was measured as the apex on the load-to-failure deflection curve. Stiffness was calculated as the linear slope on the load-to-failure deflection curve. Data were analyzed via Student’s t test.

Results

Unicortical locking constructs failed at 344 ± 119 N, while bicortical non-locking constructs were found to fail at 277 ± 101 N (p = 0.19). The unicortical locking constructs demonstrated a stiffness of 80 ± 36 N/mm compared with the bicortical non-locking constructs (69 ± 36 N/mm) although again the difference was not found to be statistically different (p = 0.49).

Conclusion

Based on this study, a locked plating construct using a polymer mechanism provides an interesting new locking fixation method for small bone fractures and with our limited number of specimens tested, provided at least a similar strength and rigidity profile in comparison with bicortical fixation in the treatment of metacarpal fractures.
Literatur
1.
Zurück zum Zitat Fusetti C, Meyer H, Borish N, Stern R, Santa DD, Papaloizos M (2002) Complications of plate fixation in metacarpals. J Trauma 52(3):535–539PubMedCrossRef Fusetti C, Meyer H, Borish N, Stern R, Santa DD, Papaloizos M (2002) Complications of plate fixation in metacarpals. J Trauma 52(3):535–539PubMedCrossRef
2.
Zurück zum Zitat Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biologic internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 84(8):1093–1110PubMedCrossRef Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biologic internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 84(8):1093–1110PubMedCrossRef
3.
Zurück zum Zitat Gautier E, Perren SM, Cordey J (2000) Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis. Injury 31(suppl 3):C14–C20PubMedCrossRef Gautier E, Perren SM, Cordey J (2000) Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis. Injury 31(suppl 3):C14–C20PubMedCrossRef
4.
Zurück zum Zitat Egol KA, Kubiak EN, Fulkerson E, Kummer FJ (2004) Biomechanics of locked plates and screws. J Orthop Trauma 18:488–493PubMedCrossRef Egol KA, Kubiak EN, Fulkerson E, Kummer FJ (2004) Biomechanics of locked plates and screws. J Orthop Trauma 18:488–493PubMedCrossRef
5.
Zurück zum Zitat Strauch RJ, Rosenwasser MP, Lunt JG (1998) Metacarpal shaft fractures: the effect of shortening on the extensor tendon mechanism. J Hand Surg Am 23(3):519–523PubMedCrossRef Strauch RJ, Rosenwasser MP, Lunt JG (1998) Metacarpal shaft fractures: the effect of shortening on the extensor tendon mechanism. J Hand Surg Am 23(3):519–523PubMedCrossRef
6.
Zurück zum Zitat Ruchelsman DE, Mudgal CS, Jupiter JB (2010) The role of locking technology in the hand. Hand Clin 26(3):307–319PubMedCrossRef Ruchelsman DE, Mudgal CS, Jupiter JB (2010) The role of locking technology in the hand. Hand Clin 26(3):307–319PubMedCrossRef
8.
Zurück zum Zitat Horn J, Linke B, Hontzsch D, Gueorquiev B, Schweiger K (2009) Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study. Injury 40(7):767–771PubMedCrossRef Horn J, Linke B, Hontzsch D, Gueorquiev B, Schweiger K (2009) Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study. Injury 40(7):767–771PubMedCrossRef
9.
Zurück zum Zitat Ochman S, Doht S, Paletta J, Langer M, Raschke MJ, Meffert RH (2010) Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model. Hand Surg Am 35(4):597–603CrossRef Ochman S, Doht S, Paletta J, Langer M, Raschke MJ, Meffert RH (2010) Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model. Hand Surg Am 35(4):597–603CrossRef
10.
Zurück zum Zitat Page SM, Stern PJ (1998) Complications and range of motion following plate fixation of metacarpal and phalangeal fractures. J Hand Surg Am 23(5):827–832PubMedCrossRef Page SM, Stern PJ (1998) Complications and range of motion following plate fixation of metacarpal and phalangeal fractures. J Hand Surg Am 23(5):827–832PubMedCrossRef
11.
Zurück zum Zitat Doht S, Jansen H, Meffert R, Frey S (2012) Higher stability with locking plates in hand surgery? Biomechanical investigation of the TriLock system in a fracture model. Int Orthop 36(8):1641–1646PubMedCentralPubMedCrossRef Doht S, Jansen H, Meffert R, Frey S (2012) Higher stability with locking plates in hand surgery? Biomechanical investigation of the TriLock system in a fracture model. Int Orthop 36(8):1641–1646PubMedCentralPubMedCrossRef
12.
Zurück zum Zitat Gajendran VK, Szabo RM, Myo GK, Curtiss SB (2009) Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model. J Hand Surg Am 34(10):1851–1858PubMedCrossRef Gajendran VK, Szabo RM, Myo GK, Curtiss SB (2009) Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model. J Hand Surg Am 34(10):1851–1858PubMedCrossRef
13.
Zurück zum Zitat Hoffmeier KL, Hoffman GO, Muckley T (2009) The strength of polyaxial locking interfaces of distal radius plates. Clin Biomech (Bristol, Avon) 24(8):637–641CrossRef Hoffmeier KL, Hoffman GO, Muckley T (2009) The strength of polyaxial locking interfaces of distal radius plates. Clin Biomech (Bristol, Avon) 24(8):637–641CrossRef
14.
Zurück zum Zitat Cordey J, Borgeaud M, Perren SM (2000) Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws friction between the plate and bone. Injury 31(suppl 3):C21–C28PubMedCrossRef Cordey J, Borgeaud M, Perren SM (2000) Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws friction between the plate and bone. Injury 31(suppl 3):C21–C28PubMedCrossRef
15.
Zurück zum Zitat Hallab NJ, McAllister K, Brady M, Jarman-Smith M (2011) Macrophage reactivity to different polymers demonstrates particle size-and material-specific reactivity: PEEK-OPTIMA® particles versus UHMWPE particles in the submicron, micron, and 10 micron size ranges. J Biomed Mater Res B Appl Biomater. E. pub Nov 21 Hallab NJ, McAllister K, Brady M, Jarman-Smith M (2011) Macrophage reactivity to different polymers demonstrates particle size-and material-specific reactivity: PEEK-OPTIMA® particles versus UHMWPE particles in the submicron, micron, and 10 micron size ranges. J Biomed Mater Res B Appl Biomater. E. pub Nov 21
16.
Zurück zum Zitat Rhee PC, Kakar S, Shin AY (2012) Four corner arthrodesis with a locking, dorsal circular polyether-ether ketone (PEEK-Optima) Plate. Tech Hand Up Extrem Surg 16(4):236–241PubMedCrossRef Rhee PC, Kakar S, Shin AY (2012) Four corner arthrodesis with a locking, dorsal circular polyether-ether ketone (PEEK-Optima) Plate. Tech Hand Up Extrem Surg 16(4):236–241PubMedCrossRef
17.
Zurück zum Zitat Kraisarin J, Dennison DG, Berglund LJ, An KN, Shin AY (2011) Biomechanical comparison of three fixation techniques used for four corner arthrodesis. J Hand Surg Eur 36(7):560–567CrossRef Kraisarin J, Dennison DG, Berglund LJ, An KN, Shin AY (2011) Biomechanical comparison of three fixation techniques used for four corner arthrodesis. J Hand Surg Eur 36(7):560–567CrossRef
18.
Zurück zum Zitat Ochman S, Vordemvenne T, Paletta J, Raschke MJ, Meffert RH, Doht S (2011) Experimental fracture model versus osteotomy model in metacarpal bone plate fixation. Sci World J 11:1692–1698CrossRef Ochman S, Vordemvenne T, Paletta J, Raschke MJ, Meffert RH, Doht S (2011) Experimental fracture model versus osteotomy model in metacarpal bone plate fixation. Sci World J 11:1692–1698CrossRef
Metadaten
Titel
Unicortical PEEK inset locking fixation for metacarpal fractures: a biomechanical study
verfasst von
Colin A. Mudrick
John R. Owen
Jennifer S. Wayne
Jonathan E. Isaacs
Publikationsdatum
01.12.2014
Verlag
Springer Paris
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 8/2014
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-013-1322-y

Weitere Artikel der Ausgabe 8/2014

European Journal of Orthopaedic Surgery & Traumatology 8/2014 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.