Erschienen in:
Open Access
17.01.2018 | Clinical Investigation
Usefulness of Hydrogel-Coated Coils in Embolization of Pulmonary Arteriovenous Malformations
verfasst von:
Masashi Shimohira, Tatsuya Kawai, Takuya Hashizume, Masahiro Muto, Masanori Kitase, Yuta Shibamoto
Erschienen in:
CardioVascular and Interventional Radiology
|
Ausgabe 6/2018
Einloggen, um Zugang zu erhalten
Abstract
Purpose
To evaluate the usefulness of hydrogel-coated coils for preventing recanalization after coil embolization of pulmonary arteriovenous malformations (PAVMs).
Materials and Methods
Thirty-seven consecutive patients with 57 untreated PAVMs underwent coil embolization with hydrogel-coated coils between January 2013 and Jun 2017. The mean age was 49 years (range 9–83 years), and there were seven male patients and 30 female patients. The median size of the feeding artery was 3.7 mm (range 1.5–6.1 mm), and the median size of the venous sac was 9.3 mm (range 2.6–36.6 mm). For all PAVM, embolization was attempted using 0.018-in. hydrogel-coated coils with or without other coils (0.0135–0.018-in. bare platinum coils and fibered platinum coils). Technical success rate, recanalization rate, and complications were evaluated. Technical success was defined as completion of embolization using hydrogel-coated coils. Recanalization was evaluated with time-resolved magnetic resonance angiography and/or pulmonary angiography.
Results
In 56 of 57 PAVMs, embolization was successfully performed with hydrogel-coated coils. Therefore, the technical success rate was 98% (56/57). The number of PAVMs at risk was 56, 42, 18, and 12 at 0, 12, 24, and 36 months, respectively. There was no recanalization with a mean follow-up period of 19 months (range 2–47 months) in 56 PAVMs embolized with hydrogel-coated coils. There were no major complications. As a minor complication, local pain was observed in 8 of 43 sessions (19%) after embolization.
Conclusions
Hydrogel-coated coils may be useful for preventing recanalization after the embolization of PAVMs.