Abstract

Purpose

To evaluate the utility of real-time contrast-enhanced ultrasound (CEUS)-guided coaxial needle biopsies for focal liver lesions (FLL) that were inconspicuous or could not be accurately identified the active site on B-mode ultrasound (US).

Materials and methods

This prospective study included 76 patients who had CEUS-guided coaxial needle biopsies for FLL between December 2015 and June 2017. We recorded characteristics of target lesions. We evaluated conspicuity of target lesions and accuracy of identifying the active site of target lesions on B-mode US and CEUS using a 5-point scale. Patients were divided into three groups, and analyzed according to body mass index (BMI). Based on the final diagnosis, the diagnostic performance was evaluated.

Results

The mean size and depth of target lesions were 41.5 ± 28.5 and 47.9 ± 18.9 mm on CEUS, respectively. In arterial phase, the enhanced pattern of target lesions varied. The conspicuity of target lesions and accuracy of identifying the active site of target lesions was significantly improved on CEUS compared to B-mode US (p < 0.05). The three BMI groups had significant differences in conspicuity of target lesions after using CEUS (p < 0.05). The high BMI group had a greater change in conspicuity of lesions compared to the normal BMI group or the low BMI group (p < 0.05). The sensitivity, specificity, and accuracy of this technique for the diagnosis of FLL were 92.8%, 100%, and 93.4%, respectively.

Conclusion

Real-time CEUS-guided coaxial needle biopsy can be very useful for FLL that are inconspicuous or cannot be accurately identified the active site on B-mode US.
Literatur
1.
Zurück zum Zitat Sparchez Z, Radu P, Zaharia T, et al. (2010) Contrast enhanced ultrasound guidance: a new tool to improve accuracy in percutaneous biopsies. Med Ultrason 12(2):133–138PubMed Sparchez Z, Radu P, Zaharia T, et al. (2010) Contrast enhanced ultrasound guidance: a new tool to improve accuracy in percutaneous biopsies. Med Ultrason 12(2):133–138PubMed
2.
Zurück zum Zitat Caliskan KC, Cakmakci E, Celebi I, Basak M (2012) The importance of experience in percutaneous liver biopsies guided with ultrasonography: a lesion-focused approach. Acad Radiol 19(2):256–259CrossRefPubMed Caliskan KC, Cakmakci E, Celebi I, Basak M (2012) The importance of experience in percutaneous liver biopsies guided with ultrasonography: a lesion-focused approach. Acad Radiol 19(2):256–259CrossRefPubMed
3.
Zurück zum Zitat Kim JW, Shin SS (2017) Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: tips to ensure safe and effective biopsy. Korean J Radiol 18(2):309–322CrossRefPubMedPubMedCentral Kim JW, Shin SS (2017) Ultrasound-guided percutaneous core needle biopsy of abdominal viscera: tips to ensure safe and effective biopsy. Korean J Radiol 18(2):309–322CrossRefPubMedPubMedCentral
4.
Zurück zum Zitat Sparchez Z, Radu P, Zaharia T, et al. (2011) Usefulness of contrast enhanced ultrasound guidance in percutaneous biopsies of liver tumors. J Gastrointest Liver Dis 20(2):191–196 Sparchez Z, Radu P, Zaharia T, et al. (2011) Usefulness of contrast enhanced ultrasound guidance in percutaneous biopsies of liver tumors. J Gastrointest Liver Dis 20(2):191–196
5.
Zurück zum Zitat Jung EM, Friedrich C, Hoffstetter P, et al. (2012) Volume navigation with contrast enhanced ultrasound and image fusion for percutaneous interventions: first results. PLoS ONE 7(3):e33956CrossRefPubMedPubMedCentral Jung EM, Friedrich C, Hoffstetter P, et al. (2012) Volume navigation with contrast enhanced ultrasound and image fusion for percutaneous interventions: first results. PLoS ONE 7(3):e33956CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Min JH, Lim HK, Lim S, et al. (2014) Radiofrequency ablation of very-early-stage hepatocellular carcinoma inconspicuous on fusion imaging with B-mode US: value of fusion imaging with contrast-enhanced US. Clin Mol Hepatol 20(1):61–70CrossRefPubMedPubMedCentral Min JH, Lim HK, Lim S, et al. (2014) Radiofrequency ablation of very-early-stage hepatocellular carcinoma inconspicuous on fusion imaging with B-mode US: value of fusion imaging with contrast-enhanced US. Clin Mol Hepatol 20(1):61–70CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Minami T, Minami Y, Chishina H, et al. (2014) Combination guidance of contrast-enhanced US and fusion imaging in radiofrequency ablation for hepatocellular carcinoma with poor conspicuity on contrast-enhanced US/fusion imaging. Oncology 87(Suppl 1):55–62CrossRefPubMed Minami T, Minami Y, Chishina H, et al. (2014) Combination guidance of contrast-enhanced US and fusion imaging in radiofrequency ablation for hepatocellular carcinoma with poor conspicuity on contrast-enhanced US/fusion imaging. Oncology 87(Suppl 1):55–62CrossRefPubMed
9.
Zurück zum Zitat Park HS, Kim YJ, Yu MH, et al. (2015) Real-time contrast-enhanced sonographically guided biopsy or radiofrequency ablation of focal liver lesions using perflurobutane microbubbles (sonazoid): value of Kupffer-phase imaging. J Ultrasound Med 34(3):411–421CrossRefPubMed Park HS, Kim YJ, Yu MH, et al. (2015) Real-time contrast-enhanced sonographically guided biopsy or radiofrequency ablation of focal liver lesions using perflurobutane microbubbles (sonazoid): value of Kupffer-phase imaging. J Ultrasound Med 34(3):411–421CrossRefPubMed
10.
Zurück zum Zitat Chung YE, Kim KW (2015) Contrast-enhanced ultrasonography: advance and current status in abdominal imaging. Ultrasonography 34(1):3–18CrossRefPubMed Chung YE, Kim KW (2015) Contrast-enhanced ultrasonography: advance and current status in abdominal imaging. Ultrasonography 34(1):3–18CrossRefPubMed
11.
Zurück zum Zitat Piscaglia F, Nolsøe C, Dietrich CA, et al. (2012) The EFSUMB guidelines and recommendations on the clinical practice of contrast enhanced ultrasound (CEUS): update 2011 on non-hepatic applications. Ultraschall Med 33(1):33–59CrossRefPubMed Piscaglia F, Nolsøe C, Dietrich CA, et al. (2012) The EFSUMB guidelines and recommendations on the clinical practice of contrast enhanced ultrasound (CEUS): update 2011 on non-hepatic applications. Ultraschall Med 33(1):33–59CrossRefPubMed
12.
Zurück zum Zitat Lee MW, Kim YJ, Park SW, et al. (2010) Sequential changes in echogenicity and conspicuity of small hepatocellular carcinoma on gray scale sonography after transcatheter arterial chemoembolization. J Ultrasound Med 29(9):1305–1312CrossRefPubMed Lee MW, Kim YJ, Park SW, et al. (2010) Sequential changes in echogenicity and conspicuity of small hepatocellular carcinoma on gray scale sonography after transcatheter arterial chemoembolization. J Ultrasound Med 29(9):1305–1312CrossRefPubMed
13.
Zurück zum Zitat Goto E, Masuzaki R, Tateishi R, et al. (2012) Value of post-vascular phase (Kupffer imaging) by contrast-enhanced ultrasonography using Sonazoid in the detection of hepatocellular carcinoma. J Gastroenterol 47(4):477–485CrossRefPubMed Goto E, Masuzaki R, Tateishi R, et al. (2012) Value of post-vascular phase (Kupffer imaging) by contrast-enhanced ultrasonography using Sonazoid in the detection of hepatocellular carcinoma. J Gastroenterol 47(4):477–485CrossRefPubMed
14.
Zurück zum Zitat Mishima M, Toh U, Iwakuma N, et al. (2016) Evaluation of contrast Sonazoid-enhanced ultrasonography for the detection of hepatic metastases in breast cancer. Breast Cancer 23(2):231–241CrossRefPubMed Mishima M, Toh U, Iwakuma N, et al. (2016) Evaluation of contrast Sonazoid-enhanced ultrasonography for the detection of hepatic metastases in breast cancer. Breast Cancer 23(2):231–241CrossRefPubMed
17.
Zurück zum Zitat Sparchez Z, Radu P, Kacso G, et al. (2015) Prospective comparison between real time contrast enhanced and conventional ultrasound guidance in percutaneous biopsies of liver tumors. Med Ultrason 17(4):456–463PubMed Sparchez Z, Radu P, Kacso G, et al. (2015) Prospective comparison between real time contrast enhanced and conventional ultrasound guidance in percutaneous biopsies of liver tumors. Med Ultrason 17(4):456–463PubMed
18.
Zurück zum Zitat Yoon SH, Lee KH, Kim SY, et al. (2010) Real-time contrast-enhanced ultrasound-guided biopsy of focal hepatic lesions not localised on B-mode ultrasound. Eur Radiol 20(8):2047–2056CrossRefPubMed Yoon SH, Lee KH, Kim SY, et al. (2010) Real-time contrast-enhanced ultrasound-guided biopsy of focal hepatic lesions not localised on B-mode ultrasound. Eur Radiol 20(8):2047–2056CrossRefPubMed
19.
Zurück zum Zitat Park HJ, Lee MW, Lee MH, et al. (2013) Fusion imaging-guided percutaneous biopsy of focal hepatic lesions with poor conspicuity on conventional sonography. J Ultrasound Med 32(9):1557–1564CrossRefPubMed Park HJ, Lee MW, Lee MH, et al. (2013) Fusion imaging-guided percutaneous biopsy of focal hepatic lesions with poor conspicuity on conventional sonography. J Ultrasound Med 32(9):1557–1564CrossRefPubMed
20.
Zurück zum Zitat Kang TW, Lee MW, Song KD, et al. (2017) Added value of contrast-enhanced ultrasound on biopsies of focal hepatic lesions invisible on fusion imaging guidance. Korean J Radiol 18(1):152–161CrossRefPubMedPubMedCentral Kang TW, Lee MW, Song KD, et al. (2017) Added value of contrast-enhanced ultrasound on biopsies of focal hepatic lesions invisible on fusion imaging guidance. Korean J Radiol 18(1):152–161CrossRefPubMedPubMedCentral
21.
Zurück zum Zitat Partovi S, Lu Z, Kessner R, et al. (2017) Contrast enhanced ultrasound guided biopsies of liver lesions not visualized on standard B-mode ultrasound-preliminary experience. J Gastrointest Oncol 8(6):1056–1064CrossRefPubMedPubMedCentral Partovi S, Lu Z, Kessner R, et al. (2017) Contrast enhanced ultrasound guided biopsies of liver lesions not visualized on standard B-mode ultrasound-preliminary experience. J Gastrointest Oncol 8(6):1056–1064CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Maturen KE, Nghiem HV, Marrero JA, et al. (2006) Lack of tumor seeding of hepatocellular carcinoma after percutaneous needle biopsy using coaxial cutting needle technique. Am J Roentgenol 187(5):1184–1187CrossRef Maturen KE, Nghiem HV, Marrero JA, et al. (2006) Lack of tumor seeding of hepatocellular carcinoma after percutaneous needle biopsy using coaxial cutting needle technique. Am J Roentgenol 187(5):1184–1187CrossRef
23.
Zurück zum Zitat Schulze R, Seebacher G, Enderes B, et al. (2015) Complications in CT-guided, semi-automatic coaxial core biopsy of potentially malignant pulmonary lesions. Rofo 187(8):697–702CrossRefPubMed Schulze R, Seebacher G, Enderes B, et al. (2015) Complications in CT-guided, semi-automatic coaxial core biopsy of potentially malignant pulmonary lesions. Rofo 187(8):697–702CrossRefPubMed
24.
Zurück zum Zitat Jandaghi AB, Habibzadeh H, Falahatkar S, et al. (2016) Transperineal prostate core needle biopsy: a comparison of coaxial versus noncoaxial method in a randomised trial. Cardiovasc Intervent Radiol 39(12):1736–1742CrossRef Jandaghi AB, Habibzadeh H, Falahatkar S, et al. (2016) Transperineal prostate core needle biopsy: a comparison of coaxial versus noncoaxial method in a randomised trial. Cardiovasc Intervent Radiol 39(12):1736–1742CrossRef
25.
Zurück zum Zitat Jandaghi AB, Lebady M, Zamani AA, et al. (2017) A randomised clinical trial to compare coaxial and noncoaxial techniques in percutaneous core needle biopsy of renal parenchyma. Cardiovasc Intervent Radiol 40(1):106–111CrossRef Jandaghi AB, Lebady M, Zamani AA, et al. (2017) A randomised clinical trial to compare coaxial and noncoaxial techniques in percutaneous core needle biopsy of renal parenchyma. Cardiovasc Intervent Radiol 40(1):106–111CrossRef
Metadaten
Titel
Usefulness of real-time contrast-enhanced ultrasound guided coaxial needle biopsy for focal liver lesions
verfasst von
Xiaojing Cao
Zhenxing Liu
Xiang Zhou
Chengyun Geng
Qing Chang
Li Zhu
Wenqi Feng
Tianyu Xu
Yujing Xin
Publikationsdatum
07.08.2018
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 1/2019
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-018-1713-y

Weitere Artikel der Ausgabe 1/2019

Abdominal Radiology 1/2019 Zur Ausgabe

Classics in Abdominal Radiology

The hyperdense crescent sign

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.