Skip to main content
Erschienen in: Heart and Vessels 8/2022

13.01.2022 | Original Article

Usefulness of the patient-specific contrast enhancement optimizer simulation software during the whole-body computed tomography angiography

verfasst von: Takanori Masuda, Toru Higaki, Takeshi Nakaura, Yoshinori Funama, Yoriaki Matsumoto, Tomoyasu Sato, Tomokazu Okimoto, Rumi Gotanda, Keiko Arao, Hiromasa Imaizumi, Shinichi Arao, Junichi Hiratsuka, Kazuo Awai

Erschienen in: Heart and Vessels | Ausgabe 8/2022

Einloggen, um Zugang zu erhalten

Abstract

To evaluate whether the patient-specific contrast enhancement optimizer simulation software (p-COP) is useful for predicting contrast enhancement during whole-body computed tomography angiography (WBCTA). We randomly divided the patients into two groups using a random number table. We used the contrast material (CM) injection protocol selected by p-COP in group A (n = 52). The p-COP used an algorithm including data on the individual patient’s cardiac output. Group B (n = 50) was assigned to the conventional CM injection protocol based on body weight. We compared the CT number in the abdominal aorta at the celiac artery level between the two groups and classified them as acceptable (> 280 HU) and unacceptable (< 279 HU) based on the optimal CT number for the WBCTA scans. To evaluate the difference in both injection protocols, we compared the visual inspection of the images of the artery of Adamkiewicz in both protocols. The CM dosage and injection rate in group A were significantly lower than those in group B (480.8 vs. 501.1 mg I/kg and 3.1 vs. 3.3 ml/s, p < 0.05). The CT number of the abdominal aorta at the celiac level was 382.4 ± 62.3 HU in group A and 363.8 ± 71.3 HU in group B (p = 0.23). CM dosage and injection rate were positively correlated to cardiac output for group A (r = 0.80, p < 0.05) and group B (r = 0.16, p < 0.05). The number of patients with an acceptable CT number was higher in group A [46/6 (86.7%)] than in group B [43/7 (71.4%)], but not significant (p = 0.71). The visualization rate for the Adamkiewicz artery was not significantly different between groups A and B (p = 0.89). The p-COP was useful for predicting contrast enhancement during WBCTA with a lower CM dosage and a lower contrast injection rate than that based on the body weight protocol. In patients with lower cardiac output a reduction in contrast injection rate and CM dosage did not lead to a reduced imaging quality, thus particularly in this group CM dosage can be reduced by p-COP.
Literatur
1.
Zurück zum Zitat Dake MD, Miller DC, Semba CP, Mitchell RS, Walker PJ, Liddell RP (1994) Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med 331(26):1729–1734CrossRef Dake MD, Miller DC, Semba CP, Mitchell RS, Walker PJ, Liddell RP (1994) Transluminal placement of endovascular stent-grafts for the treatment of descending thoracic aortic aneurysms. N Engl J Med 331(26):1729–1734CrossRef
2.
Zurück zum Zitat Volodos NL, Shekhanin VE, Karpovich IP, Troian VI, Gur’ev IuA (1986) A self-fixing synthetic blood vessel endoprosthesis. Vestn Khir Im I I Grek 137(11):123–125PubMed Volodos NL, Shekhanin VE, Karpovich IP, Troian VI, Gur’ev IuA (1986) A self-fixing synthetic blood vessel endoprosthesis. Vestn Khir Im I I Grek 137(11):123–125PubMed
3.
Zurück zum Zitat Wanhainen A, Verzini F, Van Herzeele I, Allaire E, Bown M, Cohnert T, Dick F, van Herwaarden J, Karkos C, Koelemay M, Kölbel T, Loftus I, Mani K, Melissano G, Powell J, Szeberin Z, Esvs Guidelines C, de Borst GJ, Chakfe N, Debus S, Hinchliffe R, Kakkos S, Koncar I, Kolh P, Lindholt JS, de Vega M, Vermassen F, Document R, Björck M, Cheng S, Dalman R, Davidovic L, Donas K, Earnshaw J, Eckstein HH, Golledge J, Haulon S, Mastracci T, Naylor R, Ricco JB, Verhagen H (2019) Editor’s choice—European Society for Vascular Surgery (ESVS) 2019 clinical practice guidelines on the management of abdominal aorto-iliac artery aneurysms. Eur J Vasc Endovasc Surg 57(1):8–93CrossRef Wanhainen A, Verzini F, Van Herzeele I, Allaire E, Bown M, Cohnert T, Dick F, van Herwaarden J, Karkos C, Koelemay M, Kölbel T, Loftus I, Mani K, Melissano G, Powell J, Szeberin Z, Esvs Guidelines C, de Borst GJ, Chakfe N, Debus S, Hinchliffe R, Kakkos S, Koncar I, Kolh P, Lindholt JS, de Vega M, Vermassen F, Document R, Björck M, Cheng S, Dalman R, Davidovic L, Donas K, Earnshaw J, Eckstein HH, Golledge J, Haulon S, Mastracci T, Naylor R, Ricco JB, Verhagen H (2019) Editor’s choice—European Society for Vascular Surgery (ESVS) 2019 clinical practice guidelines on the management of abdominal aorto-iliac artery aneurysms. Eur J Vasc Endovasc Surg 57(1):8–93CrossRef
4.
Zurück zum Zitat Moll FL, Powell JT, Fraedrich G, Verzini F, Haulon S, Waltham M, van Herwaarden JA, Holt PJ, van Keulen JW, Rantner B, Schlösser FJ, Setacci F, Ricco JB (2011) Management of abdominal aortic aneurysms clinical practice guidelines of the European society for vascular surgery. Eur J Vasc Endovasc Surg 41(Suppl 1):S1-s58CrossRef Moll FL, Powell JT, Fraedrich G, Verzini F, Haulon S, Waltham M, van Herwaarden JA, Holt PJ, van Keulen JW, Rantner B, Schlösser FJ, Setacci F, Ricco JB (2011) Management of abdominal aortic aneurysms clinical practice guidelines of the European society for vascular surgery. Eur J Vasc Endovasc Surg 41(Suppl 1):S1-s58CrossRef
5.
Zurück zum Zitat Valente T, Rossi G, Rea G, Pinto A, Romano L, Davies J, Scaglione M (2014) Multidetector CT findings of complications of surgical and endovascular treatment of aortic aneurysms. Radiol Clin North Am 52(5):961–989CrossRef Valente T, Rossi G, Rea G, Pinto A, Romano L, Davies J, Scaglione M (2014) Multidetector CT findings of complications of surgical and endovascular treatment of aortic aneurysms. Radiol Clin North Am 52(5):961–989CrossRef
6.
Zurück zum Zitat Heiken JP, Brink JA, McClennan BL, Sagel SS, Crowe TM, Gaines MV (1995) Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement. Radiology 195(2):353–357CrossRef Heiken JP, Brink JA, McClennan BL, Sagel SS, Crowe TM, Gaines MV (1995) Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement. Radiology 195(2):353–357CrossRef
7.
Zurück zum Zitat Yanaga Y, Awai K, Nakayama Y, Nakaura T, Tamura Y, Funama Y, Aoyama M, Asada N, Yamashita Y (2007) Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT. Radiat Med 25(6):278–288CrossRef Yanaga Y, Awai K, Nakayama Y, Nakaura T, Tamura Y, Funama Y, Aoyama M, Asada N, Yamashita Y (2007) Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT. Radiat Med 25(6):278–288CrossRef
8.
Zurück zum Zitat Awai K, Hori S (2003) Effect of contrast injection protocol with dose tailored to patient weight and fixed injection duration on aortic and hepatic enhancement at multidetector-row helical CT. Eur Radiol 13(9):2155–2160CrossRef Awai K, Hori S (2003) Effect of contrast injection protocol with dose tailored to patient weight and fixed injection duration on aortic and hepatic enhancement at multidetector-row helical CT. Eur Radiol 13(9):2155–2160CrossRef
9.
Zurück zum Zitat Yamashita Y, Komohara Y, Takahashi M, Uchida M, Hayabuchi N, Shimizu T, Narabayashi I (2000) Abdominal helical CT: evaluation of optimal doses of intravenous contrast material—a prospective randomized study. Radiology 216(3):718–723CrossRef Yamashita Y, Komohara Y, Takahashi M, Uchida M, Hayabuchi N, Shimizu T, Narabayashi I (2000) Abdominal helical CT: evaluation of optimal doses of intravenous contrast material—a prospective randomized study. Radiology 216(3):718–723CrossRef
10.
Zurück zum Zitat Higaki T, Nakaura T, Kidoh M, Yuki H, Yamashita Y, Nakamura Y, Tatsugami F, Baba Y, Iida M, Awai K (2018) Effect of contrast material injection duration on arterial enhancement at CT in patients with various cardiac indices: analysis using computer simulation. PLoS One 13(2):e0191347CrossRef Higaki T, Nakaura T, Kidoh M, Yuki H, Yamashita Y, Nakamura Y, Tatsugami F, Baba Y, Iida M, Awai K (2018) Effect of contrast material injection duration on arterial enhancement at CT in patients with various cardiac indices: analysis using computer simulation. PLoS One 13(2):e0191347CrossRef
11.
Zurück zum Zitat Matsumoto Y, Higaki T, Arataki K, Masuda T, Sato T, Fukumoto W, Nakamura Y, Tatsugami F, Awai K (2020) Individual optimization of contrast media injection protocol at hepatic dynamic computed tomography using patient-specific contrast enhancement optimizer. J Comput Assist Tomogr 44(2):230–235CrossRef Matsumoto Y, Higaki T, Arataki K, Masuda T, Sato T, Fukumoto W, Nakamura Y, Tatsugami F, Awai K (2020) Individual optimization of contrast media injection protocol at hepatic dynamic computed tomography using patient-specific contrast enhancement optimizer. J Comput Assist Tomogr 44(2):230–235CrossRef
12.
Zurück zum Zitat Matsumoto Y, Higaki T, Masuda T, Sato T, Nakamura Y, Tatsugami F, Awai K (2019) Minimizing individual variations in arterial enhancement on coronary CT angiographs using “contrast enhancement optimizer”: a prospective randomized single-center study. Eur Radiol 29(6):2998–3005CrossRef Matsumoto Y, Higaki T, Masuda T, Sato T, Nakamura Y, Tatsugami F, Awai K (2019) Minimizing individual variations in arterial enhancement on coronary CT angiographs using “contrast enhancement optimizer”: a prospective randomized single-center study. Eur Radiol 29(6):2998–3005CrossRef
13.
Zurück zum Zitat Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model. Radiology 207(3):647–655CrossRef Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model. Radiology 207(3):647–655CrossRef
14.
Zurück zum Zitat Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model. Radiology 207(3):657–662CrossRef Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model. Radiology 207(3):657–662CrossRef
15.
Zurück zum Zitat Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate–pharmacokinetic analysis and experimental porcine model. Radiology 206(2):455–464CrossRef Bae KT, Heiken JP, Brink JA (1998) Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate–pharmacokinetic analysis and experimental porcine model. Radiology 206(2):455–464CrossRef
16.
Zurück zum Zitat Blohm ME, Obrecht D, Hartwich J, Mueller GC, Kersten JF, Weil J, Singer D (2014) Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non-invasive cardiac output monitoring in pediatric intensive care patients: a prospective single-center observational study. Crit Care 18(6):603CrossRef Blohm ME, Obrecht D, Hartwich J, Mueller GC, Kersten JF, Weil J, Singer D (2014) Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non-invasive cardiac output monitoring in pediatric intensive care patients: a prospective single-center observational study. Crit Care 18(6):603CrossRef
17.
Zurück zum Zitat Hsu KH, Wu TW, Wang YC, Lim WH, Lee CC, Lien R (2016) Hemodynamic reference for neonates of different age and weight: a pilot study with electrical cardiometry. J Perinatol 36(6):481–485CrossRef Hsu KH, Wu TW, Wang YC, Lim WH, Lee CC, Lien R (2016) Hemodynamic reference for neonates of different age and weight: a pilot study with electrical cardiometry. J Perinatol 36(6):481–485CrossRef
18.
Zurück zum Zitat Halpern EJ (2009) Triple-rule-out CT angiography for evaluation of acute chest pain and possible acute coronary syndrome. Radiology 252(2):332–345CrossRef Halpern EJ (2009) Triple-rule-out CT angiography for evaluation of acute chest pain and possible acute coronary syndrome. Radiology 252(2):332–345CrossRef
19.
Zurück zum Zitat Higashigaito K, Schmid T, Puippe G, Morsbach F, Lachat M, Seifert B, Pfammatter T, Alkadhi H, Husarik DB (2016) CT angiography of the aorta: prospective evaluation of individualized low-volume contrast media protocols. Radiology 280(3):960–968CrossRef Higashigaito K, Schmid T, Puippe G, Morsbach F, Lachat M, Seifert B, Pfammatter T, Alkadhi H, Husarik DB (2016) CT angiography of the aorta: prospective evaluation of individualized low-volume contrast media protocols. Radiology 280(3):960–968CrossRef
20.
Zurück zum Zitat Lehmkuhl L, Andres C, Lücke C, Hoffmann J, Foldyna B, Grothoff M, Nitzsche S, Schmidt A, Ulrich M, Scheinert D, Gutberlet M (2013) Dynamic CT angiography after abdominal aortic endovascular aneurysm repair: influence of enhancement patterns and optimal bolus timing on endoleak detection. Radiology 268(3):890–899CrossRef Lehmkuhl L, Andres C, Lücke C, Hoffmann J, Foldyna B, Grothoff M, Nitzsche S, Schmidt A, Ulrich M, Scheinert D, Gutberlet M (2013) Dynamic CT angiography after abdominal aortic endovascular aneurysm repair: influence of enhancement patterns and optimal bolus timing on endoleak detection. Radiology 268(3):890–899CrossRef
21.
Zurück zum Zitat Sommer WH, Becker CR, Haack M, Rubin GD, Weidenhagen R, Schwarz F, Nikolaou K, Reiser MF, Johnson TR, Clevert DA (2012) Time-resolved CT angiography for the detection and classification of endoleaks. Radiology 263(3):917–926CrossRef Sommer WH, Becker CR, Haack M, Rubin GD, Weidenhagen R, Schwarz F, Nikolaou K, Reiser MF, Johnson TR, Clevert DA (2012) Time-resolved CT angiography for the detection and classification of endoleaks. Radiology 263(3):917–926CrossRef
22.
Zurück zum Zitat Tillich M, Hausegger KA, Tiesenhausen K, Tauss J, Groell R, Szolar DH (1999) Helical CT angiography of stent-grafts in abdominal aortic aneurysms: morphologic changes and complications. Radiographics 19(6):1573–1583CrossRef Tillich M, Hausegger KA, Tiesenhausen K, Tauss J, Groell R, Szolar DH (1999) Helical CT angiography of stent-grafts in abdominal aortic aneurysms: morphologic changes and complications. Radiographics 19(6):1573–1583CrossRef
23.
Zurück zum Zitat Yoshioka K, Niinuma H, Ehara S, Nakajima T, Nakamura M, Kawazoe K (2006) MR angiography and CT angiography of the artery of Adamkiewicz: state of the art. Radiographics 26(Suppl 1):S63-73CrossRef Yoshioka K, Niinuma H, Ehara S, Nakajima T, Nakamura M, Kawazoe K (2006) MR angiography and CT angiography of the artery of Adamkiewicz: state of the art. Radiographics 26(Suppl 1):S63-73CrossRef
24.
Zurück zum Zitat Meng X-L, Rosenthal R, Rubin DB (1992) Comparing correlated correlation coefficients. Psychol Bull 111(1):172–175CrossRef Meng X-L, Rosenthal R, Rubin DB (1992) Comparing correlated correlation coefficients. Psychol Bull 111(1):172–175CrossRef
25.
Zurück zum Zitat Nakaura T, Awai K, Yauaga Y, Nakayama Y, Oda S, Hatemura M, Nagayoshi Y, Ogawa H, Yamashita Y (2008) Contrast injection protocols for coronary computed tomography angiography using a 64-detector scanner: comparison between patient weight-adjusted- and fixed iodine-dose protocols. Invest Radiol 43(7):512–519CrossRef Nakaura T, Awai K, Yauaga Y, Nakayama Y, Oda S, Hatemura M, Nagayoshi Y, Ogawa H, Yamashita Y (2008) Contrast injection protocols for coronary computed tomography angiography using a 64-detector scanner: comparison between patient weight-adjusted- and fixed iodine-dose protocols. Invest Radiol 43(7):512–519CrossRef
26.
Zurück zum Zitat Masuda T, Nakaura T, Funama Y, Higaki T, Kiguchi M, Imada N, Sato T, Awai K (2017) Aortic and hepatic contrast enhancement during hepatic-arterial and portal venous phase computed tomography scanning: multivariate linear regression analysis using age, sex, total body weight, height, and cardiac output. J Comput Assist Tomogr 41(2):309–314CrossRef Masuda T, Nakaura T, Funama Y, Higaki T, Kiguchi M, Imada N, Sato T, Awai K (2017) Aortic and hepatic contrast enhancement during hepatic-arterial and portal venous phase computed tomography scanning: multivariate linear regression analysis using age, sex, total body weight, height, and cardiac output. J Comput Assist Tomogr 41(2):309–314CrossRef
27.
Zurück zum Zitat Bae KT, Heiken JP (2005) Scan and contrast administration principles of MDCT. Eur Radiol 15(Suppl 5):E46-59CrossRef Bae KT, Heiken JP (2005) Scan and contrast administration principles of MDCT. Eur Radiol 15(Suppl 5):E46-59CrossRef
28.
Zurück zum Zitat Fleischmann D (2005) How to design injection protocols for multiple detector-row CT angiography (MDCTA). Eur Radiol 15(Suppl 5):E60-65CrossRef Fleischmann D (2005) How to design injection protocols for multiple detector-row CT angiography (MDCTA). Eur Radiol 15(Suppl 5):E60-65CrossRef
29.
Zurück zum Zitat Sakai S, Yabuuchi H, Chishaki A, Okafuji T, Matsuo Y, Kamitani T, Setoguchi T, Honda H (2010) Effect of cardiac function on aortic peak time and peak enhancement during coronary CT angiography. Eur J Radiol 75(2):173–177CrossRef Sakai S, Yabuuchi H, Chishaki A, Okafuji T, Matsuo Y, Kamitani T, Setoguchi T, Honda H (2010) Effect of cardiac function on aortic peak time and peak enhancement during coronary CT angiography. Eur J Radiol 75(2):173–177CrossRef
30.
Zurück zum Zitat Ameli-Renani S, Pavlidis V, Morgan RA (2020) Secondary endoleak management following TEVAR and EVAR. Cardiovasc Intervent Radiol 43(12):1839–1854CrossRef Ameli-Renani S, Pavlidis V, Morgan RA (2020) Secondary endoleak management following TEVAR and EVAR. Cardiovasc Intervent Radiol 43(12):1839–1854CrossRef
31.
Zurück zum Zitat Bley T, Roos J (2019) IDKD springer series pre- and post-aortic endovascular interventions: what a radiologist needs to know. In: Hodler J, Kubik-Huch RA, von Schulthess GK (eds) Diseases of the chest, breast, heart and vessels 2019–2022: diagnostic and interventional imaging. Springer, Cham, pp 215–222CrossRef Bley T, Roos J (2019) IDKD springer series pre- and post-aortic endovascular interventions: what a radiologist needs to know. In: Hodler J, Kubik-Huch RA, von Schulthess GK (eds) Diseases of the chest, breast, heart and vessels 2019–2022: diagnostic and interventional imaging. Springer, Cham, pp 215–222CrossRef
32.
Zurück zum Zitat Taterra D, Skinningsrud B, Pękala PA, Hsieh WC, Cirocchi R, Walocha JA, Tubbs RS, Tomaszewski KA, Henry BM (2019) Artery of Adamkiewicz: a meta-analysis of anatomical characteristics. Neuroradiology 61(8):869–880CrossRef Taterra D, Skinningsrud B, Pękala PA, Hsieh WC, Cirocchi R, Walocha JA, Tubbs RS, Tomaszewski KA, Henry BM (2019) Artery of Adamkiewicz: a meta-analysis of anatomical characteristics. Neuroradiology 61(8):869–880CrossRef
Metadaten
Titel
Usefulness of the patient-specific contrast enhancement optimizer simulation software during the whole-body computed tomography angiography
verfasst von
Takanori Masuda
Toru Higaki
Takeshi Nakaura
Yoshinori Funama
Yoriaki Matsumoto
Tomoyasu Sato
Tomokazu Okimoto
Rumi Gotanda
Keiko Arao
Hiromasa Imaizumi
Shinichi Arao
Junichi Hiratsuka
Kazuo Awai
Publikationsdatum
13.01.2022
Verlag
Springer Japan
Erschienen in
Heart and Vessels / Ausgabe 8/2022
Print ISSN: 0910-8327
Elektronische ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-022-02024-z

Weitere Artikel der Ausgabe 8/2022

Heart and Vessels 8/2022 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.