Skip to main content
main-content

01.12.2019 | Research article | Ausgabe 1/2019 Open Access

BMC Infectious Diseases 1/2019

Utility of oral fluid samples for hepatitis B antibody detection in real life conditions

Zeitschrift:
BMC Infectious Diseases > Ausgabe 1/2019
Autoren:
Helena Medina Cruz, Vanessa Salete de Paula, Elisangela Ferreira da Silva, Kycia Maria Rodrigues do Ó, Flavio Augusto Pádua Milagres, Marcelo Santos Cruz, Francisco Inácio Bastos, Jurema Corrêa da Mota, Priscila Pollo-Flores, Erotildes Leal, Ana Rita Coimbra Motta-Castro, Lia Laura Lewis-Ximenez, Elisabeth Lampe, Livia Melo Villar
Wichtige Hinweise

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Abstract

Background

Hepatitis B virus (HBV) testing in oral fluid samples may provide advantages in diagnosis, screening or prevalence studies, especially among individuals with venous access difficulties. This study aims to optimize one commercially available assay for detecting total anti-HBc marker in oral fluid samples and to evaluate its utility under real life conditions in different settings for the purposes of prevalence and diagnostic studies.

Methods

Oral fluid was collected using a Salivette device and some parameters were initially evaluated: type of elution buffer and sample volume. Thereafter, the utility of oral fluid samples for detection of anti-HBc was evaluated in real life conditions in which, 1296 individuals gave serum and oral fluid samples. All serum samples were submitted to commercial EIAs to detect total anti-HBc, according to the manufacturer’s instructions and oral fluid samples according to previous optimization.

Results

In optimization evaluation, PBS/BSA 0.5% and 100 μL of oral fluid (volume was two-fold increased compared to serum in EIA) were chosen as transport buffer and sample volume. In the field study, anti-HBc was detected in 211 out of 1296 serum samples giving overall oral fluid sensitivity of 52.6% and specificity of 96%. Concordance was higher in ambulatory setting (67.7) compared to general population (31.8). Mean ± standard deviation values of optical density/cutoff (OD/CO) in serum samples were higher in false-negative oral fluid samples than those seen in true positive samples. Sensitivity was higher in those presenting active infection compared to anti-HBc isolate and past infection. Sensitivity also increased in the ambulatory group when HCV individuals were excluded.

Conclusions

It was possible to optimize a commercial EIA for detecting anti-HBc in oral fluid samples and where the highest concordance was found in ambulatory settings and among individuals with active infection.