Abstract

Objectives

To validate the accuracy and reproducibility of linear measurements of three-dimensional (3D) images and to compare the measurements with the direct anthropometry method on cleft lip and palate (CLP) patients.

Materials and methods

Nineteen linear facial measurements were derived from 16 standardized surface landmarks obtained from 37 cleft patients (20 males, 17 females; mean age 23.84 years, standard deviation ± 6.02). They were taken manually with calipers and were compared with the digitally calculated distance on the 3D images captured using the VECTRA-M5 360° Imaging System with pre-marked landmarks. Another pair of 19 linear measurements were computed on the 3D images 2 weeks apart for intra- and inter-observer agreements. Statistical analyses used were paired t test, the Bland-Altman analysis, and the intra-class correlation coefficient (ICC) index.

Results

Most of the linear measurements showed no statistically significant differences between the proposed method and direct anthropometry linear measurements. Nevertheless, bias of the 3D imaging system is present in the linear measurements of the nose width and the upper vermillion height. The measurements’ mean biases were within 2 mm, but the 95% limit of agreement was more than 2 mm. Intra- and inter-observer measurements generally showed good reproducibility. Four inter-observer measurements, the upper and lower face heights, nose width, and pronasale to left alar base were clinically significant.

Conclusions

Measurements obtained from this 3D imaging system are valid and reproducible for evaluating CLP patients.

Clinical relevance

The system is suitable to be used in a clinical setting for cleft patients. However, training of the operator is strictly advisable.
Literatur
1.
Zurück zum Zitat Othman SA, Ahmad R, Asi SM, Ismail NH, Rahman ZAA (2014) Three-dimensional quantitative evaluation of facial morphology in adults with unilateral cleft lip and palate, and patients without clefts. Br J Oral Maxillofac Surg 52:208–213CrossRef Othman SA, Ahmad R, Asi SM, Ismail NH, Rahman ZAA (2014) Three-dimensional quantitative evaluation of facial morphology in adults with unilateral cleft lip and palate, and patients without clefts. Br J Oral Maxillofac Surg 52:208–213CrossRef
2.
Zurück zum Zitat Krimmel M, Kluba S, Bacher M, Dietz K, Reinert S (2006) Digital surface photogrammetry for anthropometric analysis of the cleft infant face. Cleft Palate Craniofac J 43:350–355CrossRef Krimmel M, Kluba S, Bacher M, Dietz K, Reinert S (2006) Digital surface photogrammetry for anthropometric analysis of the cleft infant face. Cleft Palate Craniofac J 43:350–355CrossRef
3.
Zurück zum Zitat Koo MS, Jung S, Park H, Oh HK, Ryu SY, Cho JH, Shin HK (2014) A comparison study of different facial soft tissue analysis methods. J Craniomaxillofac Surg 42:648–656CrossRef Koo MS, Jung S, Park H, Oh HK, Ryu SY, Cho JH, Shin HK (2014) A comparison study of different facial soft tissue analysis methods. J Craniomaxillofac Surg 42:648–656CrossRef
4.
Zurück zum Zitat Dindaroğlu F, Kutlu P, Duran GS, Görgülü S, Aslan E (2016) Accuracy and reliability of 3D stereophotogrammetry: a comparison to direct anthropometry and 2D photogrammetry. Angle Orthod 86:487–494CrossRef Dindaroğlu F, Kutlu P, Duran GS, Görgülü S, Aslan E (2016) Accuracy and reliability of 3D stereophotogrammetry: a comparison to direct anthropometry and 2D photogrammetry. Angle Orthod 86:487–494CrossRef
5.
Zurück zum Zitat Fourie Z, Damstra J, Gerrits PO, Ren Y (2011) Evaluation of anthropometric accuracy and reliability using different three-dimensional scanning systems. Forensic Sci Int 207:127–134CrossRef Fourie Z, Damstra J, Gerrits PO, Ren Y (2011) Evaluation of anthropometric accuracy and reliability using different three-dimensional scanning systems. Forensic Sci Int 207:127–134CrossRef
6.
Zurück zum Zitat Heike CL, Cunningham ML, Hing AV, Stuhaug E, Starr JR (2009) Picture perfect? Reliability of craniofacial anthropometry using three-dimensional digital stereophotogrammetry. Plast Reconstr Surg 124:1261–1272CrossRef Heike CL, Cunningham ML, Hing AV, Stuhaug E, Starr JR (2009) Picture perfect? Reliability of craniofacial anthropometry using three-dimensional digital stereophotogrammetry. Plast Reconstr Surg 124:1261–1272CrossRef
7.
8.
Zurück zum Zitat Brons S, Darroudi A, Nada R, Bronkhorst EM, Vreeken R, Berge SJ, Maal T, Kuijpers-Jagtman AM (2018) Influence of involuntary facial expression on reproducibility of 3D stereophotogrammetry in children with and without complete unilateral cleft lip and palate from 3 to 18 months of age. Clin Oral Investig 23:1041–1050. https://doi.org/10.1007/s00784-018-2520-0 CrossRefPubMed Brons S, Darroudi A, Nada R, Bronkhorst EM, Vreeken R, Berge SJ, Maal T, Kuijpers-Jagtman AM (2018) Influence of involuntary facial expression on reproducibility of 3D stereophotogrammetry in children with and without complete unilateral cleft lip and palate from 3 to 18 months of age. Clin Oral Investig 23:1041–1050. https://​doi.​org/​10.​1007/​s00784-018-2520-0 CrossRefPubMed
9.
Zurück zum Zitat Tse R, Booth L, Keys K, Saltzman B, Stuhaug E, Kapadia H, Heike C (2014) Reliability of nasolabial anthropometric measures using three-dimensional stereophotogrammetry in infants with unrepaired unilateral cleft lip. Plast Reconstr Surg 133:530e–542eCrossRef Tse R, Booth L, Keys K, Saltzman B, Stuhaug E, Kapadia H, Heike C (2014) Reliability of nasolabial anthropometric measures using three-dimensional stereophotogrammetry in infants with unrepaired unilateral cleft lip. Plast Reconstr Surg 133:530e–542eCrossRef
10.
Zurück zum Zitat Khambay B, Nairn N, Bell A, Miller J, Bowman A, Ayoub AF (2008) Validation and reproducibility of a high-resolution three-dimensional facial imaging system. Br J Oral Maxillofac Surg 46:27–32CrossRef Khambay B, Nairn N, Bell A, Miller J, Bowman A, Ayoub AF (2008) Validation and reproducibility of a high-resolution three-dimensional facial imaging system. Br J Oral Maxillofac Surg 46:27–32CrossRef
11.
Zurück zum Zitat Meyer-Marcotty P, Alpers GW, Gerdes ABM, Stellzig-Eisenhauer A (2010) Impact of facial asymmetry in visual perception: a 3-dimensional data analysis. Am J Orthod Dentofac Orthop 137:168.e1–168.e8 Meyer-Marcotty P, Alpers GW, Gerdes ABM, Stellzig-Eisenhauer A (2010) Impact of facial asymmetry in visual perception: a 3-dimensional data analysis. Am J Orthod Dentofac Orthop 137:168.e1–168.e8
12.
Zurück zum Zitat Faul F, Erdfelder E, Lang AG, Buchner A (2007) G* Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39:175–191CrossRef Faul F, Erdfelder E, Lang AG, Buchner A (2007) G* Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods 39:175–191CrossRef
13.
Zurück zum Zitat Asi SM, Ismail NH, Rahman ZA (2012) Validity and reliability evaluation of data acquisition using Vectra 3D compare to direct method. In Biomedical Engineering and Sciences (IECBES), 2012 IEEE EMBS Conference on (pp. 883-887). IEEE Asi SM, Ismail NH, Rahman ZA (2012) Validity and reliability evaluation of data acquisition using Vectra 3D compare to direct method. In Biomedical Engineering and Sciences (IECBES), 2012 IEEE EMBS Conference on (pp. 883-887). IEEE
14.
Zurück zum Zitat Zreaqat M, Hassan R, Halim AS (2012) Facial dimensions of Malay children with repaired unilateral cleft lip and palate: a three dimensional analysis. Int J Oral Maxillofac Surg 41:783–788CrossRef Zreaqat M, Hassan R, Halim AS (2012) Facial dimensions of Malay children with repaired unilateral cleft lip and palate: a three dimensional analysis. Int J Oral Maxillofac Surg 41:783–788CrossRef
15.
Zurück zum Zitat Walter SD, Eliasziw M, Donner A (1998) Sample size and optimal designs for reliability studies. Stat Med 17:101–110CrossRef Walter SD, Eliasziw M, Donner A (1998) Sample size and optimal designs for reliability studies. Stat Med 17:101–110CrossRef
16.
Zurück zum Zitat Roberts CT, Richmond S (1997) The design and analysis of reliability studies for the use of epidemiological and audit indices in orthodontics. Br J Orthod 24:139–147CrossRef Roberts CT, Richmond S (1997) The design and analysis of reliability studies for the use of epidemiological and audit indices in orthodontics. Br J Orthod 24:139–147CrossRef
17.
Zurück zum Zitat Urbaniak GC, Plous S (2013) Research Randomizer (Version 4.0) [Computer software]. Retrieved on June 22, 2013 Urbaniak GC, Plous S (2013) Research Randomizer (Version 4.0) [Computer software]. Retrieved on June 22, 2013
18.
Zurück zum Zitat Aynechi N, Larson BE, Leon-Salazar V, Beiraghi S (2011) Accuracy and precision of a 3D anthropometric facial analysis with and without landmark labeling before image acquisition. Angle Orthod 81:245–252CrossRef Aynechi N, Larson BE, Leon-Salazar V, Beiraghi S (2011) Accuracy and precision of a 3D anthropometric facial analysis with and without landmark labeling before image acquisition. Angle Orthod 81:245–252CrossRef
19.
Zurück zum Zitat Farkas LG, Hajniš K, Posnick JC (1993) Anthropometric and anthroposcopic findings of the nasal and facial region in cleft patients before and after primary lip and palate repair. Cleft Palate Craniofac J 30:1–12CrossRef Farkas LG, Hajniš K, Posnick JC (1993) Anthropometric and anthroposcopic findings of the nasal and facial region in cleft patients before and after primary lip and palate repair. Cleft Palate Craniofac J 30:1–12CrossRef
20.
Zurück zum Zitat Weber DW, Fallis DW, Packer MD (2013) Three-dimensional reproducibility of natural head position. Am J Orthod Dentofacial Orthop 143:738–744CrossRef Weber DW, Fallis DW, Packer MD (2013) Three-dimensional reproducibility of natural head position. Am J Orthod Dentofacial Orthop 143:738–744CrossRef
21.
Zurück zum Zitat Winder RJ, Darvann TA, McKnight W, Magee JD, Ramsay-Baggs P (2008) Technical validation of the Di3D stereophotogrammetry surface imaging system. Br J Oral Maxillofac Surg 46:33–37CrossRef Winder RJ, Darvann TA, McKnight W, Magee JD, Ramsay-Baggs P (2008) Technical validation of the Di3D stereophotogrammetry surface imaging system. Br J Oral Maxillofac Surg 46:33–37CrossRef
22.
Zurück zum Zitat Lee JY, Han Q, Trotman CA (2004) Three-dimensional facial imaging: accuracy and considerations for clinical applications in orthodontics. Angle Orthod 74:587–593PubMed Lee JY, Han Q, Trotman CA (2004) Three-dimensional facial imaging: accuracy and considerations for clinical applications in orthodontics. Angle Orthod 74:587–593PubMed
23.
Zurück zum Zitat Weinberg SM, Naidoo S, Govier DP, Martin RA, Kane AA, Marazita ML (2006) Anthropometric precision and accuracy of digital three-dimensional photogrammetry: comparing the Genex and 3dMD imaging systems with one another and with direct anthropometry. J Craniofac Surg 17:477–483CrossRef Weinberg SM, Naidoo S, Govier DP, Martin RA, Kane AA, Marazita ML (2006) Anthropometric precision and accuracy of digital three-dimensional photogrammetry: comparing the Genex and 3dMD imaging systems with one another and with direct anthropometry. J Craniofac Surg 17:477–483CrossRef
24.
Zurück zum Zitat Wong JY, Oh AK, Ohta E, Hunt AT, Rogers GF, Mulliken JB, Deutsch CK (2008) Validity and reliability of craniofacial anthropometric measurement of 3D digital photogrammetric images. Cleft Palate Craniofac J 45:232–239CrossRef Wong JY, Oh AK, Ohta E, Hunt AT, Rogers GF, Mulliken JB, Deutsch CK (2008) Validity and reliability of craniofacial anthropometric measurement of 3D digital photogrammetric images. Cleft Palate Craniofac J 45:232–239CrossRef
25.
Zurück zum Zitat Metzler P, Sun Y, Zemann W, Bartella A, Lehner M, Obwegeser JA, Lübbers HT (2014) Validity of the 3D VECTRA photogrammetric surface imaging system for cranio-maxillofacial anthropometric measurements. J Oral Maxillofac Surg 18:297–304CrossRef Metzler P, Sun Y, Zemann W, Bartella A, Lehner M, Obwegeser JA, Lübbers HT (2014) Validity of the 3D VECTRA photogrammetric surface imaging system for cranio-maxillofacial anthropometric measurements. J Oral Maxillofac Surg 18:297–304CrossRef
26.
Zurück zum Zitat Plooij JM, Swennen GRJ, Rangel FA, Maal TJJ, Schutyser FAC, Bronkhorst EM, Berge SJ (2009) Evaluation of reproducibility and reliability of 3D soft tissue analysis using 3D stereophotogrammetry. Int J Oral Maxillofac Surg 38:267–273CrossRef Plooij JM, Swennen GRJ, Rangel FA, Maal TJJ, Schutyser FAC, Bronkhorst EM, Berge SJ (2009) Evaluation of reproducibility and reliability of 3D soft tissue analysis using 3D stereophotogrammetry. Int J Oral Maxillofac Surg 38:267–273CrossRef
27.
Zurück zum Zitat Ghoddousi H, Edler R, Haers P, Wertheim D, Greenhill D (2007) Comparison of three methods of facial measurement. Int J Oral Maxillofac Surg 36:250–258CrossRef Ghoddousi H, Edler R, Haers P, Wertheim D, Greenhill D (2007) Comparison of three methods of facial measurement. Int J Oral Maxillofac Surg 36:250–258CrossRef
28.
Zurück zum Zitat de Menezes M, Rosati R, Ferrario VF, Sforza C (2010) Accuracy and reproducibility of a 3-dimensional stereophotogrammetric imaging system. J Oral Maxillofac Surg 68:2129–2135CrossRef de Menezes M, Rosati R, Ferrario VF, Sforza C (2010) Accuracy and reproducibility of a 3-dimensional stereophotogrammetric imaging system. J Oral Maxillofac Surg 68:2129–2135CrossRef
29.
Zurück zum Zitat Aksu M, Kaya D, Kocadereli I (2010) Reliability of reference distance used in photogrammetry. Angle Orthod 80:670–677CrossRef Aksu M, Kaya D, Kocadereli I (2010) Reliability of reference distance used in photogrammetry. Angle Orthod 80:670–677CrossRef
30.
Zurück zum Zitat Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135–160CrossRef Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135–160CrossRef
31.
Zurück zum Zitat Ngeow WC, Aljunid ST (2009) Craniofacial anthropometric norms of Malays. Singap Med J 50:525–528 Ngeow WC, Aljunid ST (2009) Craniofacial anthropometric norms of Malays. Singap Med J 50:525–528
32.
Zurück zum Zitat Aldridge K, Boyadjiev SA, Capone GT, DeLeon VB, Richtsmeier JT (2005) Precision and error of three-dimensional phenotypic measures acquired from 3dMD photogrammetric images. Am J Med Genet A 15:247–253CrossRef Aldridge K, Boyadjiev SA, Capone GT, DeLeon VB, Richtsmeier JT (2005) Precision and error of three-dimensional phenotypic measures acquired from 3dMD photogrammetric images. Am J Med Genet A 15:247–253CrossRef
33.
Zurück zum Zitat Bland JM, Altman D (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327:307–310CrossRef Bland JM, Altman D (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327:307–310CrossRef
34.
Zurück zum Zitat Van Loon B, Maal TJ, Plooij JM, Ingels KJ, Borstlap WA, Kuijpers-Jagtman AM, Berge SJ (2010) 3D Stereophotogrammetric assessment of pre-and postoperative volumetric changes in the cleft lip and palate nose. Int J Oral Maxillofac Surg 39:534–540CrossRef Van Loon B, Maal TJ, Plooij JM, Ingels KJ, Borstlap WA, Kuijpers-Jagtman AM, Berge SJ (2010) 3D Stereophotogrammetric assessment of pre-and postoperative volumetric changes in the cleft lip and palate nose. Int J Oral Maxillofac Surg 39:534–540CrossRef
35.
Zurück zum Zitat Jayaratne YS, Deutsch CK, Zwahlen RA (2013) A 3D anthropometric analysis of the orolabial region in Chinese young adults. Bri J Oral Maxillofac Surg 51:908–912CrossRef Jayaratne YS, Deutsch CK, Zwahlen RA (2013) A 3D anthropometric analysis of the orolabial region in Chinese young adults. Bri J Oral Maxillofac Surg 51:908–912CrossRef
36.
Zurück zum Zitat Hajeer MY, Millett DT, Ayoub AF, Siebert JP (2004) Current products and practices: applications of 3D imaging in orthodontics: part 1. J Orthod 31:62–70CrossRef Hajeer MY, Millett DT, Ayoub AF, Siebert JP (2004) Current products and practices: applications of 3D imaging in orthodontics: part 1. J Orthod 31:62–70CrossRef
37.
Zurück zum Zitat Bartlett JW, Frost C (2008) Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables. Ultrasound Obstet Gynecol 31:466–475CrossRef Bartlett JW, Frost C (2008) Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables. Ultrasound Obstet Gynecol 31:466–475CrossRef
38.
Zurück zum Zitat Houstan WJ (1983) The analysis of errors in orthodontic measurements. Am J Orthod 83:382–390CrossRef Houstan WJ (1983) The analysis of errors in orthodontic measurements. Am J Orthod 83:382–390CrossRef
39.
Zurück zum Zitat Othman SA, Ahmad R, Merican AF, Jamaludin M (2013) Reproducibility of facial soft tissue landmarks on facial images captured on a 3D camera. Aust Orthod J 29:58–65PubMed Othman SA, Ahmad R, Merican AF, Jamaludin M (2013) Reproducibility of facial soft tissue landmarks on facial images captured on a 3D camera. Aust Orthod J 29:58–65PubMed
40.
Zurück zum Zitat Baysal A, Sahan AO, Ozturk MA, Uysal T (2016) Reproducibility and reliability of three-dimensional soft tissue landmark identification using three-dimensional stereophotogrammetry. Angle Orthod 86:1004–1009CrossRef Baysal A, Sahan AO, Ozturk MA, Uysal T (2016) Reproducibility and reliability of three-dimensional soft tissue landmark identification using three-dimensional stereophotogrammetry. Angle Orthod 86:1004–1009CrossRef
Metadaten
Titel
Validity and reproducibility of the 3D VECTRA photogrammetric surface imaging system for the maxillofacial anthropometric measurement on cleft patients
verfasst von
Siti A. Othman
Lyddia Saffai
Wan N. Wan Hassan
Publikationsdatum
21.11.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 8/2020
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-019-03150-1

Weitere Artikel der Ausgabe 8/2020

Clinical Oral Investigations 8/2020 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.