Skip to main content
Erschienen in: International Urogynecology Journal 3/2020

05.07.2019 | Original Article

Validity of bladder volume measurement by ultrasound in women postpartum

verfasst von: Josefine Tangen Jensen, Niels Klarskov, Jeannet Lauenborg

Erschienen in: International Urogynecology Journal | Ausgabe 3/2020

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Vaginal birth increases the risk of urinary retention and overdistention of the bladder. To avoid unnecessary discomfort by catheterization, it is preferable to use ultrasound for diagnosis of these conditions. The aim of this study was to determine the validity of transabdominal ultrasound and a portable ultrasound system, Biocon-700, to measure bladder volume in women postpartum.

Methods

Fifty women were included in this method comparison study. Within 48 h of giving birth, their bladder volume was measured in randomized order with both transabdominal ultrasound and Biocon-700. After urination, participants were scanned with Biocon-700 to measure residual bladder volume, and finally the bladder was emptied by catheterization. The total bladder volume was calculated as the voided volume plus the catheterized volume.

Results

Biocon-700 measured 43.4 ml ± 117.4 ml (mean ± SD) lower than the total bladder volume, while volumes measured by transabdominal ultrasound were 117.8 ml ± 110.0 ml (mean ± SD) lower. Linear regression showed significant proportional bias in both methods. The Biocon-700 could detect a residual bladder volume > 150 ml with a positive predictive value of 66.7% and a negative predictive value of 100%.

Conclusions

Neither transabdominal ultrasound nor the portable ultrasound system, Biocon-700, can be used to measure bladder volume precisely after vaginal delivery. However, both ultrasound methods can be used as screening tools to prevent overdistention of the bladder, and Biocon-700 can furthermore be used to screen women for a residual bladder volume > 150 ml.
Literatur
1.
Zurück zum Zitat Kermans G, Wyndaele JJ, Thiery M, De Sy W. Puerperal urinary retention. Acta Urol Belg. 1986;54(4):376–85.PubMed Kermans G, Wyndaele JJ, Thiery M, De Sy W. Puerperal urinary retention. Acta Urol Belg. 1986;54(4):376–85.PubMed
2.
Zurück zum Zitat Yip SK, Brieger G, Hin LY, Chung T. Urinary retention in the post-partum period. The relationship between obstetric factors and the post-partum post-void residual bladder volume. Acta Obstet Gynecol Scand. 1997;76(7):667–72.CrossRef Yip SK, Brieger G, Hin LY, Chung T. Urinary retention in the post-partum period. The relationship between obstetric factors and the post-partum post-void residual bladder volume. Acta Obstet Gynecol Scand. 1997;76(7):667–72.CrossRef
3.
Zurück zum Zitat Madersbacher H, Cardozo L, Chapple C, Abrams P, Toozs-Hobson P, Young JS, et al. What are the causes and consequences of bladder overdistension? ICI-RS 2011. Neurourol Urodyn. 2012;31(3):317–21.CrossRef Madersbacher H, Cardozo L, Chapple C, Abrams P, Toozs-Hobson P, Young JS, et al. What are the causes and consequences of bladder overdistension? ICI-RS 2011. Neurourol Urodyn. 2012;31(3):317–21.CrossRef
4.
Zurück zum Zitat Mulder FE, Hakvoort RA, Schoffelmeer MA, Limpens J, Van der Post JA, Roovers JP. Postpartum urinary retention: a systematic review of adverse effects and management. Int Urogynecol J. 2014;25(12):1605–12.CrossRef Mulder FE, Hakvoort RA, Schoffelmeer MA, Limpens J, Van der Post JA, Roovers JP. Postpartum urinary retention: a systematic review of adverse effects and management. Int Urogynecol J. 2014;25(12):1605–12.CrossRef
5.
Zurück zum Zitat Cho MK, Noh EJ, Kim CH. Accuracy and precision of a new portable ultrasound scanner, the Biocon-700, in residual urine volume measurement. Int Urogynecol J. 2017;28(7):1057–61.CrossRef Cho MK, Noh EJ, Kim CH. Accuracy and precision of a new portable ultrasound scanner, the Biocon-700, in residual urine volume measurement. Int Urogynecol J. 2017;28(7):1057–61.CrossRef
6.
Zurück zum Zitat Pallis LM, Wilson M. Ultrasound assessment of bladder volume: is it valid after delivery? Aust N Z J Obstet Gynaecol. 2003;43(6):453–6.CrossRef Pallis LM, Wilson M. Ultrasound assessment of bladder volume: is it valid after delivery? Aust N Z J Obstet Gynaecol. 2003;43(6):453–6.CrossRef
7.
Zurück zum Zitat Yip SK, Sahota D, Chang AM. Determining the reliability of ultrasound measurements and the validity of the formulae for ultrasound estimation of postvoid residual bladder volume in postpartum women. Neurourol Urodyn. 2003;22(3):255–60.CrossRef Yip SK, Sahota D, Chang AM. Determining the reliability of ultrasound measurements and the validity of the formulae for ultrasound estimation of postvoid residual bladder volume in postpartum women. Neurourol Urodyn. 2003;22(3):255–60.CrossRef
8.
Zurück zum Zitat Demaria F, Amar N, Biau D, Fritel X, Porcher R, Amarenco G, et al. Prospective 3D ultrasonographic evaluation of immediate postpartum urine retention volume in 100 women who delivered vaginally. Int Urogynecol J Pelvic Floor Dysfunct. 2004;15(4):281–5.PubMed Demaria F, Amar N, Biau D, Fritel X, Porcher R, Amarenco G, et al. Prospective 3D ultrasonographic evaluation of immediate postpartum urine retention volume in 100 women who delivered vaginally. Int Urogynecol J Pelvic Floor Dysfunct. 2004;15(4):281–5.PubMed
9.
Zurück zum Zitat Van Os AF, Van der Linden PJ. Reliability of an automatic ultrasound system in the post partum period in measuring urinary retention. Acta Obstet Gynecol Scand. 2006;85(5):604–7.CrossRef Van Os AF, Van der Linden PJ. Reliability of an automatic ultrasound system in the post partum period in measuring urinary retention. Acta Obstet Gynecol Scand. 2006;85(5):604–7.CrossRef
10.
Zurück zum Zitat Mathew S, Horne AW, Murray LS, Tydeman G, McKinley CA. Are portable bladder scanning and real-time ultrasound accurate measures of bladder volume in postnatal women? J Obstet Gynaecol. 2007;27(6):564–7.CrossRef Mathew S, Horne AW, Murray LS, Tydeman G, McKinley CA. Are portable bladder scanning and real-time ultrasound accurate measures of bladder volume in postnatal women? J Obstet Gynaecol. 2007;27(6):564–7.CrossRef
11.
Zurück zum Zitat Lukasse M, Cederkvist HR, Rosseland LA. Reliability of an automatic ultrasound system for detecting postpartum urinary retention after vaginal birth. Acta Obstet Gynecol Scand. 2007;86(10):1251–5.CrossRef Lukasse M, Cederkvist HR, Rosseland LA. Reliability of an automatic ultrasound system for detecting postpartum urinary retention after vaginal birth. Acta Obstet Gynecol Scand. 2007;86(10):1251–5.CrossRef
12.
Zurück zum Zitat Mulder FEM, van der Velde S, Pol F, Bos M, van Leeuwen JS, Dietz V, et al. Accuracy of postvoid residual volumes after vaginal delivery: a prospective equivalence study to compare an automatic scanning device with transurethral catheterization. Int Urogynecol J. 2018. Mulder FEM, van der Velde S, Pol F, Bos M, van Leeuwen JS, Dietz V, et al. Accuracy of postvoid residual volumes after vaginal delivery: a prospective equivalence study to compare an automatic scanning device with transurethral catheterization. Int Urogynecol J. 2018.
13.
Zurück zum Zitat Haylen BT, Maher CF, Barber MD, Camargo S, Dandolu V, Digesu A, et al. An international urogynecological association (IUGA)/international continence society (ICS) joint report on the terminology for female pelvic organ prolapse (POP). Int Urogynecol J. 2016;27(4):655–84.CrossRef Haylen BT, Maher CF, Barber MD, Camargo S, Dandolu V, Digesu A, et al. An international urogynecological association (IUGA)/international continence society (ICS) joint report on the terminology for female pelvic organ prolapse (POP). Int Urogynecol J. 2016;27(4):655–84.CrossRef
14.
Zurück zum Zitat Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.CrossRef Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.CrossRef
15.
Zurück zum Zitat Yip SK, Fung TY, Chung TK. Ultrasonographic estimation of postpartum postvoid residual bladder volume: a comparison between transabdominal and transvaginal ultrasonography. Int Urogynecol J Pelvic Floor Dysfunct. 1998;9(1):9–12.CrossRef Yip SK, Fung TY, Chung TK. Ultrasonographic estimation of postpartum postvoid residual bladder volume: a comparison between transabdominal and transvaginal ultrasonography. Int Urogynecol J Pelvic Floor Dysfunct. 1998;9(1):9–12.CrossRef
16.
Zurück zum Zitat Goode PS, Locher JL, Bryant RL, Roth DL, Burgio KL. Measurement of postvoid residual urine with portable transabdominal bladder ultrasound scanner and urethral catheterization. Int Urogynecol J Pelvic Floor Dysfunct. 2000;11(5):296–300.CrossRef Goode PS, Locher JL, Bryant RL, Roth DL, Burgio KL. Measurement of postvoid residual urine with portable transabdominal bladder ultrasound scanner and urethral catheterization. Int Urogynecol J Pelvic Floor Dysfunct. 2000;11(5):296–300.CrossRef
17.
Zurück zum Zitat Haylen BT, Lee J. The accuracy of post-void residual measurement in women. Int Urogynecol J Pelvic Floor Dysfunct. 2008;19(5):603–6.CrossRef Haylen BT, Lee J. The accuracy of post-void residual measurement in women. Int Urogynecol J Pelvic Floor Dysfunct. 2008;19(5):603–6.CrossRef
Metadaten
Titel
Validity of bladder volume measurement by ultrasound in women postpartum
verfasst von
Josefine Tangen Jensen
Niels Klarskov
Jeannet Lauenborg
Publikationsdatum
05.07.2019
Verlag
Springer International Publishing
Erschienen in
International Urogynecology Journal / Ausgabe 3/2020
Print ISSN: 0937-3462
Elektronische ISSN: 1433-3023
DOI
https://doi.org/10.1007/s00192-019-04037-1

Weitere Artikel der Ausgabe 3/2020

International Urogynecology Journal 3/2020 Zur Ausgabe

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.