Skip to main content
Erschienen in: European Journal of Applied Physiology 7/2011

01.07.2011 | Original Article

Validity of the Actical for estimating free-living physical activity

verfasst von: Scott E. Crouter, Diane M. DellaValle, Magdalene Horton, Jere D. Haas, Edward A. Frongillo, David R. Bassett Jr

Erschienen in: European Journal of Applied Physiology | Ausgabe 7/2011

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was twofold: (1) develop a refined 2-regression model for the Actical which predicts METs every 15 s, and (2) compare the refined and 2008 Crouter 2-regression models and the Klippel and Heil equations during free-living activity. To develop the refined 2-regression model, 48 participants (mean ± SD; age 35 ± 11.4 years) performed 10-min bouts of various activities ranging from sedentary to vigorous intensity. An Actical accelerometer was worn on the left hip, and a Cosmed K4b2 was used to measure oxygen consumption. For the free-living measurements, 29 participants (age, 38 ± 11.7 years; BMI, 25.0 ± 4.6 kg m−2) were monitored for approximately 6 h during work (N = 23) or leisure time (N = 9) while wearing an Actical and Cosmed. Actical prediction equations were compared against the Cosmed for METs and time spent in sedentary behaviors, light physical activity (LPA), moderate PA (MPA), vigorous PA (VPA), and moderate and vigorous PA (MVPA). The refined 2-regression model developed used an exponential regression equation and a linear equation to predict METs every 15 s for walking/running and intermittent lifestyle activities, respectively. Based on the free-living measurement, the refined 2-regression model was the only method that was not significantly different from the Cosmed for estimating time spent in sedentary behaviors, LPA, and MVPA (P > 0.05). On average, compared to the Cosmed, the refined 2-regression model and the Klippel and Heil equations had similar mean errors for average METs.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet North Am Ed 1:307–310 Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet North Am Ed 1:307–310
Zurück zum Zitat Byrne NM, Hills AP, Hunter GR, Weinsier RL, Schutz Y (2005) Metabolic equivalent: one size does not fit all. J Appl Physiol 99(3):1112–1119PubMedCrossRef Byrne NM, Hills AP, Hunter GR, Weinsier RL, Schutz Y (2005) Metabolic equivalent: one size does not fit all. J Appl Physiol 99(3):1112–1119PubMedCrossRef
Zurück zum Zitat Corder K, Brage S, Wareham NJ, Ekelund U (2005) Comparison of PAEE from combined and separate heart rate and movement models in children. Med Sci Sports Exerc 37(10):1761–1767PubMedCrossRef Corder K, Brage S, Wareham NJ, Ekelund U (2005) Comparison of PAEE from combined and separate heart rate and movement models in children. Med Sci Sports Exerc 37(10):1761–1767PubMedCrossRef
Zurück zum Zitat Crouter SE, Bassett DR Jr (2008) A new 2-regression model for the Actical accelerometer. Br J Sports Med 42(3):217–224PubMedCrossRef Crouter SE, Bassett DR Jr (2008) A new 2-regression model for the Actical accelerometer. Br J Sports Med 42(3):217–224PubMedCrossRef
Zurück zum Zitat Crouter SE, Churilla JR, Bassett DR Jr (2008) Accuracy of the Actiheart for the assessment of energy expenditure in adults. Eur J Clin Nutr 62:704–711PubMedCrossRef Crouter SE, Churilla JR, Bassett DR Jr (2008) Accuracy of the Actiheart for the assessment of energy expenditure in adults. Eur J Clin Nutr 62:704–711PubMedCrossRef
Zurück zum Zitat Evenson KR, Catellier DJ, Gill K, Ondrak KS, McMurray RG (2008) Calibration of two objective measures of physical activity for children. J Sports Sci 26(14):1557–1565PubMedCrossRef Evenson KR, Catellier DJ, Gill K, Ondrak KS, McMurray RG (2008) Calibration of two objective measures of physical activity for children. J Sports Sci 26(14):1557–1565PubMedCrossRef
Zurück zum Zitat Harris JA, Benedict FG (1919) A biometric study of basal metabolism in men. Carnegie Institute of Washington, Washington, DC Harris JA, Benedict FG (1919) A biometric study of basal metabolism in men. Carnegie Institute of Washington, Washington, DC
Zurück zum Zitat Heil DP (2006) Predicting activity energy expenditure using the Actical activity monitor. Res Q Exerc Sport 77(1):64–80PubMed Heil DP (2006) Predicting activity energy expenditure using the Actical activity monitor. Res Q Exerc Sport 77(1):64–80PubMed
Zurück zum Zitat Klippel NJ, Heil DP (2003) Validation of energy expenditure prediction algorithms in adults using the Actical electronic activity monitor. Med Sci Sports Exerc 35(suppl 5):S284 Klippel NJ, Heil DP (2003) Validation of energy expenditure prediction algorithms in adults using the Actical electronic activity monitor. Med Sci Sports Exerc 35(suppl 5):S284
Zurück zum Zitat Kozey S, Lyden K, Staudenmayer J, Freedson P (2010a) Errors in met estimates of physical activities using 3.5 ml × kg(−1) × min(−1) as the baseline oxygen consumption. J Phys Act Health 7(4):508–516PubMed Kozey S, Lyden K, Staudenmayer J, Freedson P (2010a) Errors in met estimates of physical activities using 3.5 ml × kg(−1)  × min(−1) as the baseline oxygen consumption. J Phys Act Health 7(4):508–516PubMed
Zurück zum Zitat Kozey SL, Lyden K, Howe CA, Staudenmayer JW, Freedson PS (2010b) Accelerometer output and met values of common physical activities. Med Sci Sports Exerc 42(9):1776–1784PubMedCrossRef Kozey SL, Lyden K, Howe CA, Staudenmayer JW, Freedson PS (2010b) Accelerometer output and met values of common physical activities. Med Sci Sports Exerc 42(9):1776–1784PubMedCrossRef
Zurück zum Zitat Kuffel EE, Crouter SE, Haas JD, Frongillo EA, Bassett DR Jr (2008) Validity of estimating minute-by-minute energy expenditure with accelerometry (abstract). Med Sci Sports Exerc 40:S415 Kuffel EE, Crouter SE, Haas JD, Frongillo EA, Bassett DR Jr (2008) Validity of estimating minute-by-minute energy expenditure with accelerometry (abstract). Med Sci Sports Exerc 40:S415
Zurück zum Zitat McLaughlin JE, King GA, Howley ET, Bassett DR Jr, Ainsworth BE (2001) Validation of the cosmed k4b2 portable metabolic system. Int J Sports Med 22(4):280–284PubMedCrossRef McLaughlin JE, King GA, Howley ET, Bassett DR Jr, Ainsworth BE (2001) Validation of the cosmed k4b2 portable metabolic system. Int J Sports Med 22(4):280–284PubMedCrossRef
Zurück zum Zitat Pfeiffer KA, McIver KL, Dowda M, Almeida MJ, Pate RR (2006) Validation and calibration of the actical accelerometer in preschool children. Med Sci Sports Exerc 38(1):152–157PubMedCrossRef Pfeiffer KA, McIver KL, Dowda M, Almeida MJ, Pate RR (2006) Validation and calibration of the actical accelerometer in preschool children. Med Sci Sports Exerc 38(1):152–157PubMedCrossRef
Zurück zum Zitat Puyau MR, Adolph AL, Vohra FA, Zakeri I, Butte NF (2004) Prediction of activity energy expenditure using accelerometers in children. Med Sci Sports Exerc 36(9):1625–1631PubMed Puyau MR, Adolph AL, Vohra FA, Zakeri I, Butte NF (2004) Prediction of activity energy expenditure using accelerometers in children. Med Sci Sports Exerc 36(9):1625–1631PubMed
Zurück zum Zitat Strath SJ, Bassett DR Jr, Swartz AM (2003) Comparison of mti accelerometer cut-points for predicting time spent in physical activity. Int J Sports Med 24(4):298–303PubMedCrossRef Strath SJ, Bassett DR Jr, Swartz AM (2003) Comparison of mti accelerometer cut-points for predicting time spent in physical activity. Int J Sports Med 24(4):298–303PubMedCrossRef
Zurück zum Zitat Tremblay MS, Wolfson M, Gorber SC (2007) Canadian health measures survey: rationale, background, and overview. Health Rep 18(Suppl):7–20PubMed Tremblay MS, Wolfson M, Gorber SC (2007) Canadian health measures survey: rationale, background, and overview. Health Rep 18(Suppl):7–20PubMed
Zurück zum Zitat Troiano RP, Berrigan D, Dodd KW, Masse LC, Tilert T, McDowell M (2008) Physical activity in the united states measured by accelerometer. Med Sci Sports Exerc 40(1):181–188PubMed Troiano RP, Berrigan D, Dodd KW, Masse LC, Tilert T, McDowell M (2008) Physical activity in the united states measured by accelerometer. Med Sci Sports Exerc 40(1):181–188PubMed
Metadaten
Titel
Validity of the Actical for estimating free-living physical activity
verfasst von
Scott E. Crouter
Diane M. DellaValle
Magdalene Horton
Jere D. Haas
Edward A. Frongillo
David R. Bassett Jr
Publikationsdatum
01.07.2011
Verlag
Springer-Verlag
Erschienen in
European Journal of Applied Physiology / Ausgabe 7/2011
Print ISSN: 1439-6319
Elektronische ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-010-1758-2

Weitere Artikel der Ausgabe 7/2011

European Journal of Applied Physiology 7/2011 Zur Ausgabe