01.01.2012 | Original Article | Ausgabe 1/2012

European Journal of Applied Physiology 1/2012

Validity of the Oxycon Mobile metabolic system under field measuring conditions

Zeitschrift:
European Journal of Applied Physiology > Ausgabe 1/2012
Autoren:
Jane Salier Eriksson, Hans Rosdahl, Peter Schantz
Wichtige Hinweise
Communicated by Susan A. Ward.

Abstract

This study aimed to validate a portable metabolic system in field measuring conditions, such as prolonged moderate exercise at low temperatures, high humidity and with external wind. VO2, VCO2, RER and V E were measured using the Oxycon Mobile (OM), with a windshield, during cycle ergometer exercise: (1) indoors at three submaximal workloads with no wind or with external wind (13–20 m s−1) from front, side and back; (2) at two submaximal workloads outdoors (12 ± 2°C; 86 ± 7% relative humidity (RH)), with and without a system for drying the ambient air around the air sampling tube; and (3) at one workload outdoors for 45 min (5 ± 4°C; 69 ± 16.5% RH). Any physiological drift was checked for with pre- and postmeasurements by the Douglas bag method (DBM). A minor effect of external wind from behind was noted in RER and V E (−2 and −3%). The system for drying the ambient air around the gas sampling tube had no effect on the measured levels. A small difference in VCO2 drift between the OM and DBM (1.5 mL min−2) was noted in the stability test. The results indicated that heavy external wind applied from different directions generally does not affect the measurements of the OM and further that, when using a unit for drying the ambient air around the gas sampling tube, the OM can accurately measure VO2, RER and V E at submaximal workloads for at least 45 min under challenging conditions with regard to humidity and temperature.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Jetzt e.Med zum Sonderpreis bestellen!

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 1/2012

European Journal of Applied Physiology 1/2012 Zur Ausgabe
  1. Sie können e.Med Allgemeinmedizin 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.


 

Neu im Fachgebiet Arbeitsmedizin

Bildnachweise