Skip to main content
Erschienen in: European Journal of Applied Physiology 1/2012

01.01.2012 | Original Article

Validity of the Oxycon Mobile metabolic system under field measuring conditions

verfasst von: Jane Salier Eriksson, Hans Rosdahl, Peter Schantz

Erschienen in: European Journal of Applied Physiology | Ausgabe 1/2012

Einloggen, um Zugang zu erhalten

Abstract

This study aimed to validate a portable metabolic system in field measuring conditions, such as prolonged moderate exercise at low temperatures, high humidity and with external wind. VO2, VCO2, RER and V E were measured using the Oxycon Mobile (OM), with a windshield, during cycle ergometer exercise: (1) indoors at three submaximal workloads with no wind or with external wind (13–20 m s−1) from front, side and back; (2) at two submaximal workloads outdoors (12 ± 2°C; 86 ± 7% relative humidity (RH)), with and without a system for drying the ambient air around the air sampling tube; and (3) at one workload outdoors for 45 min (5 ± 4°C; 69 ± 16.5% RH). Any physiological drift was checked for with pre- and postmeasurements by the Douglas bag method (DBM). A minor effect of external wind from behind was noted in RER and V E (−2 and −3%). The system for drying the ambient air around the gas sampling tube had no effect on the measured levels. A small difference in VCO2 drift between the OM and DBM (1.5 mL min−2) was noted in the stability test. The results indicated that heavy external wind applied from different directions generally does not affect the measurements of the OM and further that, when using a unit for drying the ambient air around the gas sampling tube, the OM can accurately measure VO2, RER and V E at submaximal workloads for at least 45 min under challenging conditions with regard to humidity and temperature.
Literatur
Zurück zum Zitat Åstrand P-O, Rodahl K (1986) Textbook of Work Physiology. Physiological bases of exercise, 3rd edn. McGraw-Hill, New York Åstrand P-O, Rodahl K (1986) Textbook of Work Physiology. Physiological bases of exercise, 3rd edn. McGraw-Hill, New York
Zurück zum Zitat Atkinson G, Davison RCR, Nevill AM (2005) Performance characteristics of gas analysis systems: what we know and what we need to know. Int J Sports Med 26 (Suppl 1):S2–S10PubMedCrossRef Atkinson G, Davison RCR, Nevill AM (2005) Performance characteristics of gas analysis systems: what we know and what we need to know. Int J Sports Med 26 (Suppl 1):S2–S10PubMedCrossRef
Zurück zum Zitat Attinger A, Tüller C, Souren T, Tamm M, Schindler C, Brutsche MH (2006) Feasibility of mobile cardiopulmonary exercise testing. Swiss Med Wkly 136:13–18PubMed Attinger A, Tüller C, Souren T, Tamm M, Schindler C, Brutsche MH (2006) Feasibility of mobile cardiopulmonary exercise testing. Swiss Med Wkly 136:13–18PubMed
Zurück zum Zitat Carefusion GmbH (2003) The windshield documentation. Internal documentation. CareFusion GmbH, Hoechberg Carefusion GmbH (2003) The windshield documentation. Internal documentation. CareFusion GmbH, Hoechberg
Zurück zum Zitat Carefusion GmbH (2006) The nafion tube and drying unit documentation. Internal documentation. CareFusion GmbH, Hoechberg Carefusion GmbH (2006) The nafion tube and drying unit documentation. Internal documentation. CareFusion GmbH, Hoechberg
Zurück zum Zitat Douglas CG (1911) A method for determining the total respiratory exchange in man. J Physiol 42:17–18 Douglas CG (1911) A method for determining the total respiratory exchange in man. J Physiol 42:17–18
Zurück zum Zitat Hodges LD, Brodie DA, Bromley PD (2005) Validity and reliability of selected commercially available metabolic analyzer systems. Scand J Med Sci Sports 15:271–279PubMedCrossRef Hodges LD, Brodie DA, Bromley PD (2005) Validity and reliability of selected commercially available metabolic analyzer systems. Scand J Med Sci Sports 15:271–279PubMedCrossRef
Zurück zum Zitat Huszczuk A, Whipp BJ, Wasserman K (1990) A respiratory gas exchange simulator for routine calibration in metabolic studies. Eur Respir J 3(4):465–468PubMed Huszczuk A, Whipp BJ, Wasserman K (1990) A respiratory gas exchange simulator for routine calibration in metabolic studies. Eur Respir J 3(4):465–468PubMed
Zurück zum Zitat Macfarlane D (2001) Automated metabolic gas analysis systems. A Review. Sports Med 31:841–861PubMedCrossRef Macfarlane D (2001) Automated metabolic gas analysis systems. A Review. Sports Med 31:841–861PubMedCrossRef
Zurück zum Zitat Meyer T, Davison RCR, Kindermann W (2005) Ambulatory gas exchange measurements—current status and future options. Int J Sports Med 26 (Suppl 1): S19–27 Meyer T, Davison RCR, Kindermann W (2005) Ambulatory gas exchange measurements—current status and future options. Int J Sports Med 26 (Suppl 1): S19–27
Zurück zum Zitat Mitchell JH, Saltin B (2003) The oxygen transport system and maximal oxygen uptake. In: Tipton CM (ed) Exercise physiology. People and ideas. Oxford University Press, Oxford Mitchell JH, Saltin B (2003) The oxygen transport system and maximal oxygen uptake. In: Tipton CM (ed) Exercise physiology. People and ideas. Oxford University Press, Oxford
Zurück zum Zitat Perret C, Mueller G (2006) Validation of a new portable ergospirometric device (Oxycon Mobile) during exercise. Int J Sports Med 27:363–367PubMedCrossRef Perret C, Mueller G (2006) Validation of a new portable ergospirometric device (Oxycon Mobile) during exercise. Int J Sports Med 27:363–367PubMedCrossRef
Zurück zum Zitat Rosdahl H, Gullstrand L, Salier-Eriksson J, Johansson P, Schantz P (2010) Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method. Eur J Appl Physiol 109:159–171PubMedCrossRef Rosdahl H, Gullstrand L, Salier-Eriksson J, Johansson P, Schantz P (2010) Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method. Eur J Appl Physiol 109:159–171PubMedCrossRef
Zurück zum Zitat Saltin B, Stenberg J (1964) Circulatory response to prolonged severe exercise. J Appl Physiol 19:833–838PubMed Saltin B, Stenberg J (1964) Circulatory response to prolonged severe exercise. J Appl Physiol 19:833–838PubMed
Zurück zum Zitat Stigell E, Schantz P (2006) Physically active commuting between home and work/study place in Greater Stockholm. In: Proceedings from Transport Research Arena Europe in Göteborg, Sweden, p 109 Stigell E, Schantz P (2006) Physically active commuting between home and work/study place in Greater Stockholm. In: Proceedings from Transport Research Arena Europe in Göteborg, Sweden, p 109
Zurück zum Zitat Stigell E, Schantz P (2011) Active commuting behaviours in a metropolitan setting—distance, duration, velocity and frequency in relation to mode choice and gender (submitted for publication) Stigell E, Schantz P (2011) Active commuting behaviours in a metropolitan setting—distance, duration, velocity and frequency in relation to mode choice and gender (submitted for publication)
Zurück zum Zitat Tipton CM (2006) Historical perspective: origin to recognition. In: Tipton CM, Sawka MN, Tate CA, Terjung RL (eds) ACSM’s advanced exercise physiology. Lippincott Williams & Wilkins, Baltimore, p 30 Tipton CM (2006) Historical perspective: origin to recognition. In: Tipton CM, Sawka MN, Tate CA, Terjung RL (eds) ACSM’s advanced exercise physiology. Lippincott Williams & Wilkins, Baltimore, p 30
Metadaten
Titel
Validity of the Oxycon Mobile metabolic system under field measuring conditions
verfasst von
Jane Salier Eriksson
Hans Rosdahl
Peter Schantz
Publikationsdatum
01.01.2012
Verlag
Springer-Verlag
Erschienen in
European Journal of Applied Physiology / Ausgabe 1/2012
Print ISSN: 1439-6319
Elektronische ISSN: 1439-6327
DOI
https://doi.org/10.1007/s00421-011-1985-1

Weitere Artikel der Ausgabe 1/2012

European Journal of Applied Physiology 1/2012 Zur Ausgabe