Purpose

(1) To compare the incidence of post-operative septic arthritis following anterior cruciate ligament reconstruction (ACLR) between patients receiving routine pre-operative intravenous (IV) prophylaxis only intravenous (IV) infection prophylaxis and patients receiving additional graft-soaking in a vancomycin solution (5 mg/ml) perioperatively. (2) To review the literature regarding effects of graft-soaking in vancomycin solutions on outcomes, complication rates and tendon properties in ACLR.

Methods

To identify studies pertaining to routine pre-operative IV prophylaxis and additional usage of intra-operative vancomycin-soaked grafts in primary ACLR, the Cochrane Library, SCOPUS and MEDLINE were searched till June 2018 for English and German language studies of all levels of evidence following the PRISMA guidelines. Additionally, all accepted abstracts at the ESSKA 2018, ISAKOS 2017, AGA 2017 and AOSSM 2017 meetings were screened. Data regarding the incidence of septic arthritis were abstracted and combined in a meta-analysis. Data including outcome scores, complication rates and in vitro analyses of tendon properties were collected and summarized descriptively.

Results

Upon screening 785 titles, 8 studies were included. These studies examined 5,075 patients following ACLR and followed from 6 to 52 weeks post-operatively. Of those 2099 patients in the routine pre-operative IV prophylaxis group, 44 (2.1%) cases of early septic arthritis were reported. In contrast, there were no reports of septic arthritis following ACLR in 2976 cases of vancomycin-soaked grafts. The meta-analysis yielded an odds ratio of 0.04 (0.01–0.16) favouring the addition of intra-operative vancomycin-soaking of grafts. Across all available studies, no differences in clinical outcome (i.e. incidence of ACL revision, IKDC score, Tegner score), biomechanical tendon properties, or cartilage integrity between patients with and without vancomycin-soaked grafts were identified.

Conclusion

The incidence of septic arthritis following ACLR can be reduced dramatically by vancomycin-soaking the grafts intra-operatively prior to graft passage and fixation. Within the limitation confines of this study, intra-operative graft-soaking in vancomycin appears to be a safe and effective method to reduce the incidence of septic arthritis following ACLR. Still, it remains debatable if the available data facilitate the recommendation for a universal application of vancomycin-soaking for all ACLR patients or if it should be reserved for patients at risk, including the use hamstring tendons, revision cases and in the presence of medical preconditions.

Level of evidence

Level IV, systematic review of Level III and Level IV studies.
Literatur
1.
Zurück zum Zitat Andrews JM (2001) Determination of minimum inhibitory concentrations. J Antimicrob Chemother 48(Suppl 1):5–16CrossRef Andrews JM (2001) Determination of minimum inhibitory concentrations. J Antimicrob Chemother 48(Suppl 1):5–16CrossRef
2.
Zurück zum Zitat Antoci V, Adams CS, Hickok NJ, Shapiro IM, Parvizi J (2007) Antibiotics for local delivery systems cause skeletal cell toxicity in vitro. Clin Orthop Relat Res 462:200–206CrossRef Antoci V, Adams CS, Hickok NJ, Shapiro IM, Parvizi J (2007) Antibiotics for local delivery systems cause skeletal cell toxicity in vitro. Clin Orthop Relat Res 462:200–206CrossRef
3.
Zurück zum Zitat Badran MA, Moemen DM (2016) Hamstring graft bacterial contamination during anterior cruciate ligament reconstruction: clinical and microbiological study. Int Orthop 40:1899–1903CrossRef Badran MA, Moemen DM (2016) Hamstring graft bacterial contamination during anterior cruciate ligament reconstruction: clinical and microbiological study. Int Orthop 40:1899–1903CrossRef
4.
Zurück zum Zitat Barbier O, Danis J, Versier G, Ollat D (2015) When the tendon autograft is dropped accidently on the floor: A study about bacterial contamination and antiseptic efficacy. Knee 22:280–283CrossRef Barbier O, Danis J, Versier G, Ollat D (2015) When the tendon autograft is dropped accidently on the floor: A study about bacterial contamination and antiseptic efficacy. Knee 22:280–283CrossRef
5.
Zurück zum Zitat Binnet MS, Başarir K (2007) Risk and outcome of infection after different arthroscopic anterior cruciate ligament reconstruction techniques. Arthroscopy 23:862–868CrossRef Binnet MS, Başarir K (2007) Risk and outcome of infection after different arthroscopic anterior cruciate ligament reconstruction techniques. Arthroscopy 23:862–868CrossRef
6.
Zurück zum Zitat Brand R, Kragt H (1992) Importance of trends in the interpretation of an overall odds ratio in the meta-analysis of clinical trials. Stat Med 11:2077–2082CrossRef Brand R, Kragt H (1992) Importance of trends in the interpretation of an overall odds ratio in the meta-analysis of clinical trials. Stat Med 11:2077–2082CrossRef
7.
Zurück zum Zitat Brandl G, Pauzenberger L, Laky B, Anderl W (2018) Vancomycin in ACL reconstruction - a retrospective analysis of clinical outcome and occurrence of postoperative deep infection with or without graft-presoaking. Knee Surg Sports Traumatol Arthrosc 26:5–126CrossRef Brandl G, Pauzenberger L, Laky B, Anderl W (2018) Vancomycin in ACL reconstruction - a retrospective analysis of clinical outcome and occurrence of postoperative deep infection with or without graft-presoaking. Knee Surg Sports Traumatol Arthrosc 26:5–126CrossRef
8.
Zurück zum Zitat Brophy RH, Wright RW, Huston LJ, Nwosu SK, Spindler KP (2015) Factors associated with infection following anterior cruciate ligament reconstruction. J Bone Joint Surg Am 97:450–454CrossRef Brophy RH, Wright RW, Huston LJ, Nwosu SK, Spindler KP (2015) Factors associated with infection following anterior cruciate ligament reconstruction. J Bone Joint Surg Am 97:450–454CrossRef
9.
Zurück zum Zitat Burks RT, Friederichs MG, Fink B, Luker MG, West HS, Greis PE (2003) Treatment of postoperative anterior cruciate ligament infections with graft removal and early reimplantation. Am J Sports Med 31:414–418CrossRef Burks RT, Friederichs MG, Fink B, Luker MG, West HS, Greis PE (2003) Treatment of postoperative anterior cruciate ligament infections with graft removal and early reimplantation. Am J Sports Med 31:414–418CrossRef
10.
Zurück zum Zitat Calvo R, Figueroa D, Anastasiadis Z, Vaisman A, Olid A, Gili F, Valderrama JJ, De La Fuente P (2014) Septic arthritis in ACL reconstruction surgery with hamstring autografts. Eleven years of experience. Knee 21:717–720CrossRef Calvo R, Figueroa D, Anastasiadis Z, Vaisman A, Olid A, Gili F, Valderrama JJ, De La Fuente P (2014) Septic arthritis in ACL reconstruction surgery with hamstring autografts. Eleven years of experience. Knee 21:717–720CrossRef
11.
Zurück zum Zitat Cooper DE, Arnoczky SP, Warren RF (1991) Contaminated patellar tendon grafts: incidence of positive cultures and efficacy of an antibiotic solution soak–an in vitro study. Arthroscopy 7:272–274CrossRef Cooper DE, Arnoczky SP, Warren RF (1991) Contaminated patellar tendon grafts: incidence of positive cultures and efficacy of an antibiotic solution soak–an in vitro study. Arthroscopy 7:272–274CrossRef
12.
Zurück zum Zitat Edin ML, Miclau T, Lester GE, Lindsey RW, Dahners LE (1996) Effect of cefazolin and vancomycin on osteoblasts in vitro. Clin Orthop Relat Res 333:245–251CrossRef Edin ML, Miclau T, Lester GE, Lindsey RW, Dahners LE (1996) Effect of cefazolin and vancomycin on osteoblasts in vitro. Clin Orthop Relat Res 333:245–251CrossRef
13.
Zurück zum Zitat Efe T, Scharm A, Spies-Naumann A, Schüttler K (2017) Untersuchung zur Dosierung und biomechanischem Einfluss von lokalem Vancomycin in einem Infektmodell zur vorderen Kreuzbandplastik. AGA Munich Efe T, Scharm A, Spies-Naumann A, Schüttler K (2017) Untersuchung zur Dosierung und biomechanischem Einfluss von lokalem Vancomycin in einem Infektmodell zur vorderen Kreuzbandplastik. AGA Munich
14.
Zurück zum Zitat Granan L-P, Inacio MCS, Maletis GB, Funahashi TT, Engebretsen L (2012) Intraoperative findings and procedures in culturally and geographically different patient and surgeon populations: an anterior cruciate ligament reconstruction registry comparison between Norway and the USA. Acta Orthop 83:577–582CrossRef Granan L-P, Inacio MCS, Maletis GB, Funahashi TT, Engebretsen L (2012) Intraoperative findings and procedures in culturally and geographically different patient and surgeon populations: an anterior cruciate ligament reconstruction registry comparison between Norway and the USA. Acta Orthop 83:577–582CrossRef
15.
Zurück zum Zitat Grayson JE, Grant GD, Dukie S, Vertullo CJ (2011) The in vitro elution characteristics of vancomycin from tendons. Clin Orthop Relat Res 469:2948–2952CrossRef Grayson JE, Grant GD, Dukie S, Vertullo CJ (2011) The in vitro elution characteristics of vancomycin from tendons. Clin Orthop Relat Res 469:2948–2952CrossRef
16.
Zurück zum Zitat Hiller NL, Chauhan A, Palmer M, Jain S, Sotereanos NG, Altman GT, Nistico L, Kreft R, Post JC, Demeo PJ (2015) Presence of bacteria in failed anterior cruciate ligament reconstructions. Springerplus 4:460CrossRef Hiller NL, Chauhan A, Palmer M, Jain S, Sotereanos NG, Altman GT, Nistico L, Kreft R, Post JC, Demeo PJ (2015) Presence of bacteria in failed anterior cruciate ligament reconstructions. Springerplus 4:460CrossRef
17.
Zurück zum Zitat Holmes N, Tong S, Davis J, Hal S (2015) Treatment of Methicillin-resistant Staphylococcus aureus: vancomycin and beyond. Semin Respir Crit Care Med 36:017–030CrossRef Holmes N, Tong S, Davis J, Hal S (2015) Treatment of Methicillin-resistant Staphylococcus aureus: vancomycin and beyond. Semin Respir Crit Care Med 36:017–030CrossRef
18.
Zurück zum Zitat Indelli PF, Dillingham M, Fanton G, Schurman DJ (2002) Septic arthritis in postoperative anterior cruciate ligament reconstruction. Clin Orthop Relat Res 398:182–188CrossRef Indelli PF, Dillingham M, Fanton G, Schurman DJ (2002) Septic arthritis in postoperative anterior cruciate ligament reconstruction. Clin Orthop Relat Res 398:182–188CrossRef
19.
Zurück zum Zitat Judd D, Bottoni C, Kim D, Burke M, Hooker S (2006) Infections following arthroscopic anterior cruciate ligament reconstruction. Arthroscopy 22:375–384CrossRef Judd D, Bottoni C, Kim D, Burke M, Hooker S (2006) Infections following arthroscopic anterior cruciate ligament reconstruction. Arthroscopy 22:375–384CrossRef
20.
Zurück zum Zitat Kanj WW, Flynn JM, Spiegel DA, Dormans JP, Baldwin KD (2013) Vancomycin prophylaxis of surgical site infection in clean orthopedic surgery. Orthopedics 36:138–146CrossRef Kanj WW, Flynn JM, Spiegel DA, Dormans JP, Baldwin KD (2013) Vancomycin prophylaxis of surgical site infection in clean orthopedic surgery. Orthopedics 36:138–146CrossRef
21.
Zurück zum Zitat Khan M, Rothrauff BB, Merali F, Musahl V, Peterson D, Ayeni OR (2014) Management of the contaminated anterior cruciate ligament graft. Arthroscopy 30:236–244CrossRef Khan M, Rothrauff BB, Merali F, Musahl V, Peterson D, Ayeni OR (2014) Management of the contaminated anterior cruciate ligament graft. Arthroscopy 30:236–244CrossRef
22.
Zurück zum Zitat Kung J, Chiappelli F, Cajulis OO, Avezova R, Kossan G, Chew L, Maida CA (2010) From systematic reviews to clinical recommendations for evidence-based health care: validation of revised assessment of multiple systematic reviews (R-AMSTAR) for grading of clinical relevance. Open Dent J 4:84–91PubMedPubMedCentral Kung J, Chiappelli F, Cajulis OO, Avezova R, Kossan G, Chew L, Maida CA (2010) From systematic reviews to clinical recommendations for evidence-based health care: validation of revised assessment of multiple systematic reviews (R-AMSTAR) for grading of clinical relevance. Open Dent J 4:84–91PubMedPubMedCentral
23.
Zurück zum Zitat Lubowitz JH (2015) Editorial commentary: hamstring autografts are more frequently associated with ACL infection. Arthroscopy 31:1402CrossRef Lubowitz JH (2015) Editorial commentary: hamstring autografts are more frequently associated with ACL infection. Arthroscopy 31:1402CrossRef
24.
Zurück zum Zitat Makhni EC, Steinhaus ME, Mehran N, Schulz BS, Ahmad CS (2015) Functional outcome and graft retention in patients with septic arthritis after anterior cruciate ligament reconstruction: a systematic review. Arthroscopy 31:1392–1401CrossRef Makhni EC, Steinhaus ME, Mehran N, Schulz BS, Ahmad CS (2015) Functional outcome and graft retention in patients with septic arthritis after anterior cruciate ligament reconstruction: a systematic review. Arthroscopy 31:1392–1401CrossRef
25.
Zurück zum Zitat McHugh ML (2012) Interrater reliability: the kappa statistic. Biochem Med 22:276–282CrossRef McHugh ML (2012) Interrater reliability: the kappa statistic. Biochem Med 22:276–282CrossRef
26.
Zurück zum Zitat Molina ME, Nonweiller DE, Evans JA, Contaminated anterior cruciate ligament grafts: the efficacy of 3 sterilization agents. Arthroscopy 16:373–378 Molina ME, Nonweiller DE, Evans JA, Contaminated anterior cruciate ligament grafts: the efficacy of 3 sterilization agents. Arthroscopy 16:373–378
27.
Zurück zum Zitat Offerhaus C, Balke M, Höher J (2018) Pre-soaking of hamstring grafts reduces risk of infection after ACL-reconstruction. A prospective study including 1500 patients. Knee Surg Sports Traumatol Arthrosc 26:5–126CrossRef Offerhaus C, Balke M, Höher J (2018) Pre-soaking of hamstring grafts reduces risk of infection after ACL-reconstruction. A prospective study including 1500 patients. Knee Surg Sports Traumatol Arthrosc 26:5–126CrossRef
28.
Zurück zum Zitat Pérez-Prieto D, Portillo ME, Torres-Claramunt R, Pelfort X, Hinarejos P, Monllau JC (2018) Contamination occurs during ACL graft harvesting and manipulation, but it can be easily eradicated. Knee Surg Sports Traumatol Arthrosc 26:558–562CrossRef Pérez-Prieto D, Portillo ME, Torres-Claramunt R, Pelfort X, Hinarejos P, Monllau JC (2018) Contamination occurs during ACL graft harvesting and manipulation, but it can be easily eradicated. Knee Surg Sports Traumatol Arthrosc 26:558–562CrossRef
29.
Zurück zum Zitat Pérez-Prieto D, Torres-Claramunt R, Gelber PE, Shehata TMA, Pelfort X, Monllau JC (2016) Autograft soaking in vancomycin reduces the risk of infection after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 24:2724–2728CrossRef Pérez-Prieto D, Torres-Claramunt R, Gelber PE, Shehata TMA, Pelfort X, Monllau JC (2016) Autograft soaking in vancomycin reduces the risk of infection after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 24:2724–2728CrossRef
30.
Zurück zum Zitat Phegan M, Grayson JE, Vertullo CJ (2016) No infections in 1300 anterior cruciate ligament reconstructions with vancomycin pre-soaking of hamstring grafts. Knee Surg Sports Traumatol Arthrosc 24:2729–2735CrossRef Phegan M, Grayson JE, Vertullo CJ (2016) No infections in 1300 anterior cruciate ligament reconstructions with vancomycin pre-soaking of hamstring grafts. Knee Surg Sports Traumatol Arthrosc 24:2729–2735CrossRef
31.
Zurück zum Zitat Plante MJ, Li X, Scully G, Brown MA, Busconi BD, DeAngelis NA (2013) Evaluation of sterilization methods following contamination of hamstring autograft during anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 21:696–701CrossRef Plante MJ, Li X, Scully G, Brown MA, Busconi BD, DeAngelis NA (2013) Evaluation of sterilization methods following contamination of hamstring autograft during anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 21:696–701CrossRef
32.
Zurück zum Zitat Schollin-Borg M, Michaëlsson K, Rahme H (2003) Presentation, outcome, and cause of septic arthritis after anterior cruciate ligament reconstruction: a case control study. Arthroscopy 19:941–947CrossRef Schollin-Borg M, Michaëlsson K, Rahme H (2003) Presentation, outcome, and cause of septic arthritis after anterior cruciate ligament reconstruction: a case control study. Arthroscopy 19:941–947CrossRef
33.
Zurück zum Zitat Schulz AP, Götze S, Schmidt HGK, Jürgens C, Faschingbauer M (2007) Septic arthritis of the knee after anterior cruciate ligament surgery: a stage-adapted treatment regimen. Am J Sports Med 35:1064–1069CrossRef Schulz AP, Götze S, Schmidt HGK, Jürgens C, Faschingbauer M (2007) Septic arthritis of the knee after anterior cruciate ligament surgery: a stage-adapted treatment regimen. Am J Sports Med 35:1064–1069CrossRef
34.
Zurück zum Zitat Shea BJ, Grimshaw JM, Wells GA, Boers M, Andersson N, Hamel C, Porter AC, Tugwell P, Moher D, Bouter LM (2007) Development of AMSTAR: a measurement tool to assess the methodological quality of systematic reviews. BMC Med Res Methodol 7:10CrossRef Shea BJ, Grimshaw JM, Wells GA, Boers M, Andersson N, Hamel C, Porter AC, Tugwell P, Moher D, Bouter LM (2007) Development of AMSTAR: a measurement tool to assess the methodological quality of systematic reviews. BMC Med Res Methodol 7:10CrossRef
35.
Zurück zum Zitat Slim K, Nini E, Forestier D, Kwiatkowski F, Panis Y, Chipponi J (2003) Methodological index for non-randomized studies (minors): development and validation of a new instrument. ANZ J Surg 73:712–716CrossRef Slim K, Nini E, Forestier D, Kwiatkowski F, Panis Y, Chipponi J (2003) Methodological index for non-randomized studies (minors): development and validation of a new instrument. ANZ J Surg 73:712–716CrossRef
36.
Zurück zum Zitat Vertullo CJ, Quick M, Jones A, Grayson JE (2012) A surgical technique using presoaked vancomycin hamstring grafts to decrease the risk of infection after anterior cruciate ligament reconstruction. Arthroscopy 28:337–342CrossRef Vertullo CJ, Quick M, Jones A, Grayson JE (2012) A surgical technique using presoaked vancomycin hamstring grafts to decrease the risk of infection after anterior cruciate ligament reconstruction. Arthroscopy 28:337–342CrossRef
Metadaten
Titel
Vancomycin-soaking of the graft reduces the incidence of septic arthritis following ACL reconstruction: results of a systematic review and meta-analysis
verfasst von
Jan-Hendrik Naendrup
Benedikt Marche
Darren de SA
Paola Koenen
Robin Otchwemah
Arasch Wafaisade
Thomas R. Pfeiffer
Publikationsdatum
17.01.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 4/2020
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-019-05353-1

Weitere Artikel der Ausgabe 4/2020

Knee Surgery, Sports Traumatology, Arthroscopy 4/2020 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.