Skip to main content
main-content

01.03.2012 | Original Paper | Ausgabe 3/2012

International Orthopaedics 3/2012

Variability of medial and posterior offset in patients with fourth-generation stemmed shoulder arthroplasty

Zeitschrift:
International Orthopaedics > Ausgabe 3/2012
Autoren:
Ulrich Irlenbusch, Alexander Berth, Georges Blatter, Peter Zenz

Abstract

Purpose

Most anthropometric data on the proximal humerus has been obtained from deceased healthy individuals with no deformities. Endoprostheses are implanted for primary and secondary osteoarthritis, rheumatoid arthritis, humeral-head necrosis, fracture sequelae and other humeral-head deformities. This indicates that pathologicoanatomical variability may be greater than previously assumed. We therefore investigated a group of patients with typical shoulder replacement diagnoses, including posttraumatic and rheumatic deformities.

Material and methods

One hundred and twenty-two patients with a double eccentrically adjustable shaft endoprosthesis served as a specific dimension gauge to determine in vivo the individual humeral-head rotation centres from the position of the adjustable prosthesis taper and the eccentric head.

Results

All prosthesis heads were positioned eccentrically. The entire adjustment range of the prosthesis of 12 mm medial/lateral and 6 mm dorsal/ventral was required. Mean values for effective offset were 5.84 mm mediolaterally [standard deviation (SD) 1.95, minimum +2, maximum +11] and 1.71 mm anteroposteriorly (SD 1.71, minimum −3, maximum 3 mm), averaging 5.16 mm (SD 1.76, minimum +2, maximum + 10). The posterior offset averaged 1.85 mm (SD 1.85, minimum −1, maximum + 6 mm).

Conclusions

In summary, variability of the combined medial and dorsal offset of the humeral-head rotational centre determined in patients with typical underlying diagnoses in shoulder replacement was not greater than that recorded in the literature for healthy deceased patients. The range of deviation is substantial and shows the need for an adjustable prosthetic system.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 3/2012

International Orthopaedics 3/2012 Zur Ausgabe
  1. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.

Neu im Fachgebiet Orthopädie und Unfallchirurgie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Orthopädie und Unfallchirurgie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise