Variations in the distance between the cricoid cartilage and targets of stellate ganglion block in neutral and extended supine positions: an ultrasonographic evaluation

verfasst von: Jiwon An, Youn-Woo Lee, Woo Young Park, Sungchul Park, Hyungbae Park, Ji Won Yoo, Jong Bum Choi

Erschienen in: Journal of Anesthesia | Ausgabe 6/2016

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN

Abstract

Purpose

Anatomic variations complicate surface landmark-guided needle placement, thereby increasing nerve blockade failure rate. However, little is understood about how anatomic distances change under different clinical conditions. As the cricoid cartilage is an easy and accurate landmark, we investigated changes in distance between the sixth or seventh cervical transverse processes (C6TP or C7TP) and the cricoid cartilage in neutral and extended supine positions.

Methods

Forty-two patients (16 men, 26 women) were included in this study. Distances between the cricoid cartilage and C6TP/C7TP were measured using ultrasonography with the patient in neutral and extended supine positions.

Results

C6TP and C7TP were caudally located at 6.0 ± 8.1 and 15.1 ± 7.2 mm, respectively, from the cricoid cartilage in the neutral supine position, and at 15.2 ± 8.0 and 25.3 ± 8.0 mm, respectively, in the extended supine position. In the extended supine position, the cricoid cartilage was more cephalad than C6TP and C7TP in all patients. The distance from the cricoid cartilage to C6TP was 12.1 ± 7.6 mm in men and 17.2 ± 7.7 mm in women.

Conclusion

C6TP and C7TP are located approximately 15 and 25 mm, respectively, caudal to the cricoid cartilage in the extended supine position. Our results highlight the fact that there can be significant anatomic variation between the extended and neutral supine positions used in stellate ganglion block, which should be kept in mind when devising easily identifiable and palpable surface landmarks.

Introduction

Stellate ganglion block (SGB) is a sympathetic nerve block used in the treatment of head and neck pain, pain of the upper extremities, vascular disease, or sensorineural hearing loss [1]. SGB is generally performed via the anterior paratracheal approach at the level of the C6 transverse process (C6TP) and C7TP. Although ultrasound or fluoroscopy-guided approaches are available, the classical blind technique is mostly used in primary pain clinics, because ultrasound or fluoroscopy-guided techniques require training and are expensive. Moreover, the fluoroscopy-guided technique is injurious to health because of exposure to radiation. However, the classical blind technique is associated with risks due to inappropriate needle placement, such as carotid trauma, neural injury, and vascular trauma. The most common classical blind technique used for SGB is the anterior paratracheal approach at the level of the C6TP [2]. In this approach, the patient is placed in the supine position with a small pillow between the shoulders. After skin draping, the index and middle fingers are placed between the medial head of the sternocleidomastoid muscle and the trachea. A 22-gauge needle is directed through the skin in a perpendicular direction until bone is encountered at the level of the sixth or seventh cervical vertebrae [3]. In this technique, the most important landmark is the C6TP, also known as Chassaignac’s tubercle. It is widely known that, in most patients, the C6TP is located lateral to the cricoid cartilage and is easily palpated [2]. Hence, some clinicians use the cricoid cartilage as the landmark for finding the C6TP. However, in most patients, the C6TP is not located lateral to the cricoid cartilage while performing SGB, because SGB is performed in the extended supine position with a pillow under the patient’s neck, and the cricoid cartilage is expected to be displaced cephalad [4]. Thus, we assume that the cricoid cartilage could be displaced, but it is not clear from textbooks or any research that the cricoid cartilage will displace when the neck extends. Furthermore, it is not known what distances the cricoid cartilage will displace when the neck extends. In this study, we measured the distance from the C6TP and C7TP to the cricoid cartilage in the neutral supine position and the extended supine position using ultrasonography.

Materials and methods

This study was approved by the institutional review board at Yonsei University, Gangnam Severance Hospital. Forty-two patients were enrolled from November 2011 to October 2012 at the pain clinic in our hospital. Written informed consent was obtained from all patients for inclusion in this study. Patients aged >20 years and undergoing musculoskeletal ultrasonography were included. Exclusion criteria were previous neck or cervical spine surgery; a history of rheumatoid arthritis, cerebral palsy or tumor; severe pain at the time of evaluation; and illiteracy. After giving informed consent, patients were placed in the supine position with the neck in the neutral position. The anterior portion of the neck was scanned using ultrasonography (S-nerve; SonoSite Inc., Bothell, WA, USA) with a linear probe drawn longitudinally along the axis of the cervical spine until the cricoid cartilage was located downward from the thyroid cartilage. In this view, we marked the center of the cross-section of the cricoid cartilage and drew a line perpendicular to the neck; this was labeled ‘Cricoid(N)’. In the transverse view of the neck, the neck was scanned anterolaterally with the linear probe along the axis of the neck. After locating the C6TP and C7TP, we marked the two midpoints of the transverse processes on the skin and drew lines perpendicular to the neck and parallel to the line Cricoid(N); these were labeled ‘C6TP(N)’ and ‘C7TP(N)’. The distance between Cricoid(N) and C6TP(N) and that between Cricoid(N) and C7TP(N) was then measured (Fig. 1). To establish the extended supine position, we placed a 10-cm diameter cylindrical pillar under the neck, extending it. A pain clinician with 5 years of experience adjusted the neck until the standard SGB position was reached. Repeating the procedure for the neutral supine position, we drew parallel lines passing through the center of the cross-sections of the cricoid cartilage, C6TP, and C7TP and perpendicular to the neck, and labeled these lines as Cricoid(E), C6TP(E), and C7TP(E), respectively (Fig. 2). We measured the distance between Cricoid(E) and C6TP(E) and that between Cricoid(E) and C7TP(E). If the cricoid cartilage was positioned more cephalad than C6TP or C7TP, we assigned a positive value to the distance; if it was more caudal than C6TP or C7TP, we gave a negative value to the distance.
The requisite patient sample size was determined from the raw data of a previous study by power analysis, with an α-error of 0.05 and a β-error of 0.2. The mean sample size (standard deviation) was −23.3 (9.6), −5.0 (12.5), −5.2 (10.4), and 14.4 (11.8) in the neutral position in men, extended position in men, neutral position in women, and extended position in women, respectively [4]. The final sample size was determined to be 42 (16 men, 26 women), allowing for a dropout rate of 10 %.
Patient characteristics are reported using descriptive statistics. We calculated means and standard deviations for distances from the cricoid cartilage to the C6TP and C7TP in the neutral and extended positions. The paired t test was used to compare differences between the extended and neutral positions. The two-sample t test was used to compare differences by sex. A p value <0.05 was considered to be statistically significant. Statistical Package for the Social Sciences version 20.0 software (IBM Corp., Armonk, NY, USA) was used for all statistical analyses.

Results

Forty-two patients (16 men, 26 women; mean age 54.5 years; range 27–91 years) were included in the study. Demographic data for the participants are shown in Table 1.
Table 1
Demographic data of the patients
 
Male
Female
Total
No.
16
26
42
Age (years)
46.1 (14.7)
59.7 (13.8)
54.5 (15.5)
Height (cm)
172.5 (9.1)
156.3 (6.0)
162.5 (10.7)
Weight (kg)
74 (10.5)
58.9 (10.1)
64.7 (12.6)
Values are mean (SD)
In the neutral supine position, the mean distances from the cricoid cartilage to the C6TP and C7TP were 6.0 and 15.1 mm, respectively. In the extended supine position, these distances were 15.2 and 25.3 mm, respectively. The difference between the corresponding distances in the neutral and extended supine positions was statistically significant (p < 0.001 for both; Table 2).
Table 2
Distances from the cricoid cartilage to the C6 transverse process or the C7 transverse process in the neutral and extended supine positions of the neck (mm)
 
Neutral supine position
Extended supine position
p value
Cricoid-C6TP
6.0 (8.1)
15.2 (8.0)
<0.001*
Cricoid-C7TP
15.1 (7.2)
25.3 (8.0)
<0.001*
Values are mean (SD)
Cricoid-C6TP the distance from the cricoid cartilage to the C6 transverse process, Cricoid-C7TP the distance from the cricoid cartilage to the C7 transverse process
*p < 0.05 between neutral and extended position
The distance from the cricoid cartilage to the C6TP was significantly different between men and women in both the neutral (p = 0.028) and extended (p = 0.041) supine positions. The distance from the cricoid cartilage to the C6TP was significantly different between the neutral and extended supine positions in both sexes (p < 0.001 for men and women; Table 3).
Table 3
Distances from the cricoid cartilage to the C6 transverse process based on sex in the neutral and extended supine positions of the neck (mm)
 
Neutral supine position
Extended supine position
p value
Male
2.6 (9.2)
12.1 (7.6)
<0.001*
Female
8.2 (6.7)
17.2 (7.7)
<0.001*
p value
0.028
0.041
 
Values are mean (SD)
*p < 0.05 between neutral and extended position
p < 0.05 between men and women
The distance from the cricoid cartilage to the C7TP was not significantly different between men and women in the neutral supine position (p = 0.148) or in the extended supine position (p = 0.132); however, it was different between the two positions in both men (p < 0.001) and women (p < 0.001; Table 4).
Table 4
Distances from the cricoid cartilage to the C7 transverse process based on sex in the neutral and extended supine positions of the neck (mm)
 
Neutral supine position
Extended supine position
p value
Male
13.0 (7.1)
22.9 (8.2)
<0.001*
Female
16.4 (7.2)
26.8 (7.6)
<0.001*
p value
0.148
0.132
 
Values are mean (SD)
*p < 0.05 between neutral and extended position

Discussion

In this study, we evaluated the distance between the cricoid cartilage and C6TP and C7TP when patients are in the neutral supine position and the extended supine position. The cricoid cartilage was positioned, on average, more cephalad than the C6TP and C7TP in the supine position in all except seven patients (16.7 %) in the neutral supine position [six of these seven patients (94.2 %) were men], and in all patients (100 %) in the extended supine position. This means that the targets of SGB, i.e., C6TP and C7TP, should be located caudal to the cricoid cartilage in the extended position.
Further research on SGB target points was performed using radiography [4]. This study analyzed the cervical vertebrae and explored the relationship between the cricoid cartilage and the C6TP. However, the X-ray of the cervical vertebrae was not obtained in the supine position, so the position was different from that used in SGB.
When the patient is placed in an extended supine position for SGB, the cricoid cartilage moves cephalad. We cannot conclude that the tubercle that moves laterally from the cricoid cartilage is the C6TP. However, we can conclude that when performing SGB with the patient in an extended supine position, C6TP and C7TP are found more caudally than the cricoid cartilage. In the neutral and extended supine positions, the distance from the cricoid cartilage to the C6TP in men was significantly different from that in women, whereas no such difference was found for the distance between the cricoid cartilage and the C7TP. Thus, the SGB injection point will be different between men and women for C6TP, but will not be different for C7TP. The reason for these results may be the anatomic difference between the sexes in the thyroid cartilage or muscular connections between the thyroid cartilage and cricoid cartilage.
There are a few limitations to this study. First, we did not explore any racial differences or effects of aging, body mass index, or other factors that could affect anatomy and neck movement. Second, we did not perform SGB to confirm its success rate using this technique.
To summarize, in this study, we evaluated the distance between the cricoid cartilage and C6TP and C7TP when patients are in the neutral supine and extended supine positions. Establishing these distances will help clinicians find the C6TP and C7TP, targets of SGB, easily and accurately. The currently used classical blind technique is easily performed by clinicians but is inconvenient for patients, especially those who are muscular or have a short neck. The method of finding the C6TP or C7TP by locating the cricoid cartilage is inaccurate at present because the cricoid cartilage moves upon neck extension. Real-time scanning by ultrasonography or fluoroscopy is expensive, time-consuming (requires training), and hazardous because of radiation exposure. Therefore, our method may provide the estimated location of C6TP or C7TP to primary pain clinicians performing SGB procedures. Further studies are required to establish the practicality and accuracy of this method by examining the outcome of SGB when the C6TP and C7TP are located using the cricoid cartilage as a landmark.

Acknowledgments

The authors thank Dong-Su Jang (Research Assistant, Department of Anatomy, Yonsei University College of Medicine, Seoul, Korea) for his excellent support with medical illustration.

Compliance with ethical standards

Conflict of interest

No external funding and no competing interests declared.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Anästhesiologie

Kombi-Abonnement

Mit e.Med Anästhesiologie erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes AINS, den Premium-Inhalten der AINS-Fachzeitschriften, inklusive einer gedruckten AINS-Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Elias M. Cervical sympathetic and stellate ganglion blocks. Pain Phys. 2003;3:294–304. Elias M. Cervical sympathetic and stellate ganglion blocks. Pain Phys. 2003;3:294–304.
2.
Zurück zum Zitat Janik JE, Hoeft MA, Ajar AH, Alsofrom GF, Borrello MT, Rathmell JP. Variable osteology of the sixth cervical vertebra in relation to stellate ganglion block. Regul Anesth Pain Med. 2008;33:102–8.CrossRef Janik JE, Hoeft MA, Ajar AH, Alsofrom GF, Borrello MT, Rathmell JP. Variable osteology of the sixth cervical vertebra in relation to stellate ganglion block. Regul Anesth Pain Med. 2008;33:102–8.CrossRef
3.
Zurück zum Zitat Jones RR. Observations pertaining to block of the stellate ganglion. Anesth Analg. 1961;40:616–8.CrossRefPubMed Jones RR. Observations pertaining to block of the stellate ganglion. Anesth Analg. 1961;40:616–8.CrossRefPubMed
4.
Zurück zum Zitat Park JS, Kim KJ, Lee YW, Yoon DM, Yoon KB, Han MY, Choi JB. Estimation of stellate ganglion block injection point using the cricoid cartilage as landmark through X-ray review. Korean J Pain. 2011;24:141–5.CrossRefPubMedPubMedCentral Park JS, Kim KJ, Lee YW, Yoon DM, Yoon KB, Han MY, Choi JB. Estimation of stellate ganglion block injection point using the cricoid cartilage as landmark through X-ray review. Korean J Pain. 2011;24:141–5.CrossRefPubMedPubMedCentral
Metadaten
Titel
Variations in the distance between the cricoid cartilage and targets of stellate ganglion block in neutral and extended supine positions: an ultrasonographic evaluation
verfasst von
Jiwon An
Youn-Woo Lee
Woo Young Park
Sungchul Park
Hyungbae Park
Ji Won Yoo
Jong Bum Choi
Publikationsdatum
30.08.2016
Verlag
Springer Japan
Erschienen in
Journal of Anesthesia / Ausgabe 6/2016
Print ISSN: 0913-8668
Elektronische ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-016-2236-8

Weitere Artikel der Ausgabe 6/2016

Journal of Anesthesia 6/2016 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.