Skip to main content
Erschienen in:

26.11.2021 | Special Feature: Review Article

Vascular access management of hemodialysis patients at the bedside using point-of-care ultrasound

verfasst von: Atsushi Onoue, Takahiro Akiyama

Erschienen in: Journal of Medical Ultrasonics | Ausgabe 4/2022

Einloggen, um Zugang zu erhalten

Abstract

When vascular access (VA) for hemodialysis is established using an autologous fistula or synthetic graft, repeated damage from needle insertion at each dialysis session can lead to thrombosis, resulting in vascular stenosis or occlusion that can cause poor blood removal, elevated venous pressure, and other impairments of blood flow. Compact, high-performance ultrasound devices have been developed in recent years. Such devices are used for point-of-care ultrasound (POCUS), which has been used on many occasions for emergency evaluation in the dialysis room and is becoming an important tool in VA management. POCUS provides a wealth of imaging information, such as needle position, whether the needle is inside or outside the blood vessel, and lesion position, width, and depth. This allows clinicians to detect VA problems early and take suitable measures, such as changing the cannulation site, thereby avoiding the need for unnecessary and highly invasive angiography or surgical procedures.
Literatur
1.
Zurück zum Zitat Wiese P, Daniel BN. Colour Doppler ultrasound in dialysis access. Nephrol Dial Transplant. 2004;19:1956–63.CrossRefPubMed Wiese P, Daniel BN. Colour Doppler ultrasound in dialysis access. Nephrol Dial Transplant. 2004;19:1956–63.CrossRefPubMed
2.
Zurück zum Zitat Finlay DE, Longley DG, Foshager MC, et al. Duplex and color Doppler sonography of hemodialysis arteriovenous fistulas and grafts. Radiographics. 1993;13:983–99.CrossRefPubMed Finlay DE, Longley DG, Foshager MC, et al. Duplex and color Doppler sonography of hemodialysis arteriovenous fistulas and grafts. Radiographics. 1993;13:983–99.CrossRefPubMed
3.
Zurück zum Zitat Malovrh M. Strategy for the maximal use of native arteriovenous fistulae for hemodialysis. Sci World J. 2006;6:808–915.CrossRef Malovrh M. Strategy for the maximal use of native arteriovenous fistulae for hemodialysis. Sci World J. 2006;6:808–915.CrossRef
4.
Zurück zum Zitat Hossain S, Sharma A, Dubois L, et al. Preoperative point-of-care ultrasound and its impact on arteriovenous fistula maturation outcomes. J Vasc Surg. 2018;68:1157–65.CrossRefPubMed Hossain S, Sharma A, Dubois L, et al. Preoperative point-of-care ultrasound and its impact on arteriovenous fistula maturation outcomes. J Vasc Surg. 2018;68:1157–65.CrossRefPubMed
5.
Zurück zum Zitat Brown PWG. Preoperative radiological assessment for vascular access. Eur J Vasc Endovasc Surg. 2006;31:64–9.CrossRefPubMed Brown PWG. Preoperative radiological assessment for vascular access. Eur J Vasc Endovasc Surg. 2006;31:64–9.CrossRefPubMed
6.
Zurück zum Zitat Silva MB, Hobson RW, Pappas PJ, et al. A strategy for increasing use of autogenous hemodialysis access procedures: Impact of preoperative noninvasive evaluation. J Vasc Surg. 1998;27:302–8.CrossRefPubMed Silva MB, Hobson RW, Pappas PJ, et al. A strategy for increasing use of autogenous hemodialysis access procedures: Impact of preoperative noninvasive evaluation. J Vasc Surg. 1998;27:302–8.CrossRefPubMed
7.
Zurück zum Zitat Korten E, Toonder IM, Schrama YC, et al. Dialysis fistulae patency and preoperative diameter ultrasound measurements. Eur J Endovasc Surg. 2007;33:467–71.CrossRef Korten E, Toonder IM, Schrama YC, et al. Dialysis fistulae patency and preoperative diameter ultrasound measurements. Eur J Endovasc Surg. 2007;33:467–71.CrossRef
8.
Zurück zum Zitat Malovrh M. Native arteriovenous fistula: preoperative evaluation. Am J Kidney Dis. 2002;9:218–25. Malovrh M. Native arteriovenous fistula: preoperative evaluation. Am J Kidney Dis. 2002;9:218–25.
9.
Zurück zum Zitat Yerdel MA, Kesenci M, Yazicioglu KM, et al. Effect of haemodynamic variables on surgically created arteriovenous fistula flow. Nephrol Dial Transplant. 1997;12:1684–8.CrossRefPubMed Yerdel MA, Kesenci M, Yazicioglu KM, et al. Effect of haemodynamic variables on surgically created arteriovenous fistula flow. Nephrol Dial Transplant. 1997;12:1684–8.CrossRefPubMed
10.
Zurück zum Zitat Coritsidis GN, Machado ON, Levi-Haim F, et al. Point-of-care ultrasound for assessing arteriovenous fistula maturity in outpatient hemodialysis. J Vasc Access. 2020;21:923–30.CrossRefPubMed Coritsidis GN, Machado ON, Levi-Haim F, et al. Point-of-care ultrasound for assessing arteriovenous fistula maturity in outpatient hemodialysis. J Vasc Access. 2020;21:923–30.CrossRefPubMed
11.
Zurück zum Zitat Sands JJ, Kapsick B. Assessment of hemodialysis access performance by color-flow Doppler ultrasound. Biomater Appl. 1999;13:224–37.CrossRef Sands JJ, Kapsick B. Assessment of hemodialysis access performance by color-flow Doppler ultrasound. Biomater Appl. 1999;13:224–37.CrossRef
12.
Zurück zum Zitat Sands J, Young S, Miranda C. The effect of Doppler flow screening studies and elective revisions on dialysis access failure. ASAIO. 1992;38:524–7.CrossRef Sands J, Young S, Miranda C. The effect of Doppler flow screening studies and elective revisions on dialysis access failure. ASAIO. 1992;38:524–7.CrossRef
13.
Zurück zum Zitat Strauch BS, O’Connell RS, Geoly KL, et al. Forecasting thrombosis of vascular access with Doppler color flow imaging. Am J Kidney Dis. 1992;19:554–7.CrossRefPubMed Strauch BS, O’Connell RS, Geoly KL, et al. Forecasting thrombosis of vascular access with Doppler color flow imaging. Am J Kidney Dis. 1992;19:554–7.CrossRefPubMed
14.
Zurück zum Zitat Pietura R, Janczarek M, Zaluska W, et al. Colour Doppler ultrasound assessment of well-functioning mature arteriovenous fistulas for haemodialysis access. Eur J Radiol. 2005;55:113–9.CrossRefPubMed Pietura R, Janczarek M, Zaluska W, et al. Colour Doppler ultrasound assessment of well-functioning mature arteriovenous fistulas for haemodialysis access. Eur J Radiol. 2005;55:113–9.CrossRefPubMed
15.
Zurück zum Zitat Weitzel WF, Rubin JM, Leavey SF, et al. Analysis of variable flow doppler hemodialysis access flow measurements and comparison with ultrasound dilution. Am J Kidney Dis. 2001;38:935–40.CrossRefPubMed Weitzel WF, Rubin JM, Leavey SF, et al. Analysis of variable flow doppler hemodialysis access flow measurements and comparison with ultrasound dilution. Am J Kidney Dis. 2001;38:935–40.CrossRefPubMed
16.
Zurück zum Zitat Leblanc M, Saint-Sauveur E, Pichette V. Native arterio-venous fistula for hemodialysis: what to expect early after creation? J Vasc Access. 2003;4:39–44.CrossRefPubMed Leblanc M, Saint-Sauveur E, Pichette V. Native arterio-venous fistula for hemodialysis: what to expect early after creation? J Vasc Access. 2003;4:39–44.CrossRefPubMed
17.
Zurück zum Zitat Onoue A, Imada A, Takahashi K, et al. Usefulness of an ultrasonic pulse Doppler method for monitoring vascular access function. Ther Eng. 2007;19:256–62 (in Japanese). Onoue A, Imada A, Takahashi K, et al. Usefulness of an ultrasonic pulse Doppler method for monitoring vascular access function. Ther Eng. 2007;19:256–62 (in Japanese).
18.
Zurück zum Zitat Onoue A, Higashino Y, Ohno T, et al. Usefulness for functional evaluation with blood flow volume, resistance index and stenosis diameter of vascular access. Jpn J Med Ultrasound Technol. 2011;36:587–92 (in Japanese). Onoue A, Higashino Y, Ohno T, et al. Usefulness for functional evaluation with blood flow volume, resistance index and stenosis diameter of vascular access. Jpn J Med Ultrasound Technol. 2011;36:587–92 (in Japanese).
19.
Zurück zum Zitat Gilmore CA, Burnett URH, Straw RJ, et al. Ultrasound guided intravenous cannula insertion – reflection. Radiographer. 2012;59:73–6.CrossRef Gilmore CA, Burnett URH, Straw RJ, et al. Ultrasound guided intravenous cannula insertion – reflection. Radiographer. 2012;59:73–6.CrossRef
20.
Zurück zum Zitat Patel RA, Stern AS, Brown M, et al. Bedside ultrasonography for arteriovenous fistula cannulation. Semin Dial. 2015;28:433–4.CrossRefPubMed Patel RA, Stern AS, Brown M, et al. Bedside ultrasonography for arteriovenous fistula cannulation. Semin Dial. 2015;28:433–4.CrossRefPubMed
21.
Zurück zum Zitat Sedlacek M, Teodorescu V, Falk A, et al. Hemodialysis access placement with preoperative noninvasive vascular mapping: comparison between patients with and without diabetes. Am J Kidney Dis. 2001;38:560–4.CrossRefPubMed Sedlacek M, Teodorescu V, Falk A, et al. Hemodialysis access placement with preoperative noninvasive vascular mapping: comparison between patients with and without diabetes. Am J Kidney Dis. 2001;38:560–4.CrossRefPubMed
22.
Zurück zum Zitat Kukita K, Ohira S, Amano I, et al. 2011 Update Japanese Society for Dialysis Therapy Guidelines of vascular access construction and repair for chronic hemodialysis. Ther Apher Dial. 2015;19:1–39.CrossRefPubMed Kukita K, Ohira S, Amano I, et al. 2011 Update Japanese Society for Dialysis Therapy Guidelines of vascular access construction and repair for chronic hemodialysis. Ther Apher Dial. 2015;19:1–39.CrossRefPubMed
23.
Zurück zum Zitat Nakagawa Y, Ota K, Sato Y, et al. Complications in blood access for hemodialysis. Artif Organs. 1994;18:283–8.CrossRefPubMed Nakagawa Y, Ota K, Sato Y, et al. Complications in blood access for hemodialysis. Artif Organs. 1994;18:283–8.CrossRefPubMed
24.
Zurück zum Zitat Schoch M, Bennett PN, Currey J, et al. Point-of-care ultrasound use for vascular access assessment and cannulation in hemodialysis: a scoping review. Semin Dial. 2020;33:355–68.CrossRefPubMedPubMedCentral Schoch M, Bennett PN, Currey J, et al. Point-of-care ultrasound use for vascular access assessment and cannulation in hemodialysis: a scoping review. Semin Dial. 2020;33:355–68.CrossRefPubMedPubMedCentral
Metadaten
Titel
Vascular access management of hemodialysis patients at the bedside using point-of-care ultrasound
verfasst von
Atsushi Onoue
Takahiro Akiyama
Publikationsdatum
26.11.2021
Verlag
Springer Nature Singapore
Erschienen in
Journal of Medical Ultrasonics / Ausgabe 4/2022
Print ISSN: 1346-4523
Elektronische ISSN: 1613-2254
DOI
https://doi.org/10.1007/s10396-021-01161-8

Neu im Fachgebiet Radiologie

KI-gestütztes Mammografiescreening überzeugt im Praxistest

Mit dem Einsatz künstlicher Intelligenz lässt sich die Detektionsrate im Mammografiescreening offenbar deutlich steigern. Mehr unnötige Zusatzuntersuchungen sind laut der Studie aus Deutschland nicht zu befürchten.

Stumme Schlaganfälle − ein häufiger Nebenbefund im Kopf-CT?

In 4% der in der Notfallambulanz initiierten zerebralen Bildgebung sind „alte“ Schlaganfälle zu erkennen. Gar nicht so selten handelt es sich laut einer aktuellen Studie dabei um unbemerkte Insulte. Bietet sich hier womöglich die Chance auf ein effektives opportunistisches Screening?

Die elektronische Patientenakte kommt: Das sollten Sie jetzt wissen

Am 15. Januar geht die „ePA für alle“ zunächst in den Modellregionen an den Start. Doch schon bald soll sie in allen Praxen zum Einsatz kommen. Was ist jetzt zu tun? Was müssen Sie wissen? Wir geben in einem FAQ Antworten auf 21 Fragen.

Stören weiße Wände und viel Licht die Bildqualitätskontrolle?

Wenn es darum geht, die technische Qualität eines Mammogramms zu beurteilen, könnten graue Wandfarbe und reduzierte Beleuchtung im Bildgebungsraum von Vorteil sein. Darauf deuten zumindest Ergebnisse einer kleinen Studie hin. 

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.