Skip to main content
Erschienen in: European Radiology 8/2004

01.08.2004 | Chest

Virtual endoscopy of the tracheo-bronchial system: sub-millimeter collimation with the 16-row multidetector scanner

verfasst von: M. Fawad Khan, Christopher Herzog, Hanns Ackermann, Thomas O. F. Wagner, Adel Maataoui, Marc Harth, Nasreddin D. Abolmaali, Volkmar Jacobi, Thomas J. Vogl

Erschienen in: European Radiology | Ausgabe 8/2004

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to evaluate the scope of sub-millimeter collimation reconstruction parameters using 16-row computer tomography and ECG triggering on image quality in virtual bronchoscopy. Thirty-two patients (5 women, 27 men, mean age 66.6±1.4) who had been admitted for coronary artery bypass graft surgery underwent CT examination of the thorax (Sensation 16, Siemens, Inc., Forchheim, Germany). All patients were examined with 16×0.75-mm collimation. Image reconstruction was performed for two groups. In group A (n=32), slice thickness of 1.5 mm and an overlap of 0.75 mm were used. In group B (n=32), slice thickness of 0.75 mm and an overlap of 0.4 mm were applied. Retrospective ECG triggering was performed in all patients. The maximum order of recognizable bronchi was determined in each data set. In addition to assessing the maximum order of bronchial bifurcation, bronchial diameter was determined in truly perpendicular sections in each patient. For every segment proximal to a bifurcation, image quality was subjectively graded as poor (grade 1), moderate (grade 2) or good (grade 3). The observers were asked to identify the minimum cardiac movement ECG-triggered image sets assuming that they would be of better quality than the maximum cardiac movement ECG-triggered image sets. The Mann-Whitney U-test and the Fisher’s Exact Test were used for statistical evaluation. In group A, a mean of 4.8±0.2 bifurcations was ascertained vs. 6.5±0.3 bifurcations in group B [P<0.0003]. For bronchial diameters in group A, a mean of 7.5±0.4 mm was determined vs. 4.6±0.4 mm in group B [P<0.0001]. In group B, two independent radiologists observed a significant shift to better image quality in all segments evaluated [P<0.006 to P<0.000001]. Motion artifacts were judged as being significantly reduced by minimum cardiac movement ECG-triggering in group B [observer 1: P=0.0007 (20/32); observer 2: P=0.008 (18/32)], but not in group A [observer 1: P=0.286 (13/32); observer 2: P=0.123 (16/32)]. Sub-millimeter collimation and minimum cardiac movement ECG-triggered data acquisition allow deeper penetration into the tracheo-bronchial system allowing visualization of the bronchial surface down to diameters below 5 mm in certain cases up to the eighth bifurcation. Along with an enhanced visualization as such, better image quality is acquired in all segments evaluated. Trade off between better image quality, of doubtful diagnostic consequence, and much higher irradiation dose must be made.
Literatur
1.
Zurück zum Zitat Naidich DP, Lee JJ, Garay SM et al (1987) Comparison of CT and fiberoptic bronchoscopy in the evaluation of bronchial disease. Am J Roentgenol 148:1–7 Naidich DP, Lee JJ, Garay SM et al (1987) Comparison of CT and fiberoptic bronchoscopy in the evaluation of bronchial disease. Am J Roentgenol 148:1–7
2.
Zurück zum Zitat Henschke CI, Davis SD, Romando AP et al (1987) Detection of bronchial abnormalities: comparison of CT and bronchoscopy. J Comput Assist Tomogr 11:432–435PubMed Henschke CI, Davis SD, Romando AP et al (1987) Detection of bronchial abnormalities: comparison of CT and bronchoscopy. J Comput Assist Tomogr 11:432–435PubMed
3.
Zurück zum Zitat Naidich DP, Harkin TJ (1995) Airways and lung correlation of CT with fiberoptic bronchoscopy. Radiology 197:1–12 Naidich DP, Harkin TJ (1995) Airways and lung correlation of CT with fiberoptic bronchoscopy. Radiology 197:1–12
4.
Zurück zum Zitat McAdams HP, Palmer SM, Erasmus JJ et al (1998) Bronchial anastomotic complications in lung transplant recipients: virtual bronchoscopy for noninvasive assessment. Radiology 209:689–695PubMed McAdams HP, Palmer SM, Erasmus JJ et al (1998) Bronchial anastomotic complications in lung transplant recipients: virtual bronchoscopy for noninvasive assessment. Radiology 209:689–695PubMed
5.
Zurück zum Zitat McAdams HP, Goodman PC, Kussin P (1998) Virtual bronchoscopy for directing transbronchial needle aspiration of hilar and mediastinal lymph nodes: a pilot study. Am J Roentgenol 170:1361–1364 McAdams HP, Goodman PC, Kussin P (1998) Virtual bronchoscopy for directing transbronchial needle aspiration of hilar and mediastinal lymph nodes: a pilot study. Am J Roentgenol 170:1361–1364
6.
Zurück zum Zitat Morrin MM, LaMont JT (2003) Screening virtual colonoscopy—ready for prime time? N Engl J Med 349:2191–2200CrossRefPubMed Morrin MM, LaMont JT (2003) Screening virtual colonoscopy—ready for prime time? N Engl J Med 349:2191–2200CrossRefPubMed
7.
Zurück zum Zitat Kay CL, Evangelou HA (1996) A review of the technical and clinical aspects of virtual endoscopy. Endoscopy 28:768–775PubMed Kay CL, Evangelou HA (1996) A review of the technical and clinical aspects of virtual endoscopy. Endoscopy 28:768–775PubMed
8.
Zurück zum Zitat Vining DJ, Liu K, Choplin RH (1996) Virtual bronchoscopy: relationship of virtual reality endobronchial simulations to actual bronchoscopic findings. Chest 109:549–553PubMed Vining DJ, Liu K, Choplin RH (1996) Virtual bronchoscopy: relationship of virtual reality endobronchial simulations to actual bronchoscopic findings. Chest 109:549–553PubMed
9.
Zurück zum Zitat Hoppe H, Dinkel HP, Walder B, Von Allmen G, Gugger M, Vock P (2004) Grading airway stenosis down to the segmental level using virtual bronchoscopy. Chest 125:704–711CrossRefPubMed Hoppe H, Dinkel HP, Walder B, Von Allmen G, Gugger M, Vock P (2004) Grading airway stenosis down to the segmental level using virtual bronchoscopy. Chest 125:704–711CrossRefPubMed
10.
Zurück zum Zitat Finkelstein SE, Schrump DS, Nguyen DM, Hewitt SM, Kunst TF, Summers RM (2003) Comparative evaluation of super high-resolution CT scan and virtual bronchoscopy for the detection of tracheobronchial malignancies. Chest 124:1834–1840CrossRefPubMed Finkelstein SE, Schrump DS, Nguyen DM, Hewitt SM, Kunst TF, Summers RM (2003) Comparative evaluation of super high-resolution CT scan and virtual bronchoscopy for the detection of tracheobronchial malignancies. Chest 124:1834–1840CrossRefPubMed
11.
Zurück zum Zitat Summers RH, Feng DH, Holland SM (1996) Virtual bronchoscopy: segmentation method for real-time display. Radiology 199:321–330PubMed Summers RH, Feng DH, Holland SM (1996) Virtual bronchoscopy: segmentation method for real-time display. Radiology 199:321–330PubMed
12.
Zurück zum Zitat Kalender WA (2003) Computed tomography. Publicis MCD, Munich, p 110 Kalender WA (2003) Computed tomography. Publicis MCD, Munich, p 110
13.
Zurück zum Zitat Neumann K, Winterer J, Kimmig M et al (2000) Real-time interactive virtual endoscopy of the tracheo-bronchial system: influence of CT imaging protocols and observer ability. Eur J Radiol 33:50–54CrossRefPubMed Neumann K, Winterer J, Kimmig M et al (2000) Real-time interactive virtual endoscopy of the tracheo-bronchial system: influence of CT imaging protocols and observer ability. Eur J Radiol 33:50–54CrossRefPubMed
14.
Zurück zum Zitat Herzog C, Abolmaali N, Balzer JO et al (2002) Heart-rate adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed Herzog C, Abolmaali N, Balzer JO et al (2002) Heart-rate adapted image reconstruction in multidetector-row cardiac CT: influence of physiological and technical prerequisite on image quality. Eur Radiol 12:2670–2678PubMed
15.
Zurück zum Zitat Costello P (1994) Spiral CT of the thorax. Semin Ultrasound CT MR 15:90–106PubMed Costello P (1994) Spiral CT of the thorax. Semin Ultrasound CT MR 15:90–106PubMed
16.
Zurück zum Zitat Fleiter T, Merkle EM, Aschoff AJ, Lang G, Stein M, Gorich J, Liewald F, Rilinger N, Sokiranski R (1997) Comparison of real-time virtual and fiberoptic bronchoscopy in patients with bronchial carcinoma: opportunities and limitations. Am J Roentgenol 169:1591–1595PubMed Fleiter T, Merkle EM, Aschoff AJ, Lang G, Stein M, Gorich J, Liewald F, Rilinger N, Sokiranski R (1997) Comparison of real-time virtual and fiberoptic bronchoscopy in patients with bronchial carcinoma: opportunities and limitations. Am J Roentgenol 169:1591–1595PubMed
17.
Zurück zum Zitat Rubin GD, Beaulieu CF, Argiro V et al (1996) Perspective volume rendering of CT and MR images: applications for endoscopic imaging. Radiology 199:321–330PubMed Rubin GD, Beaulieu CF, Argiro V et al (1996) Perspective volume rendering of CT and MR images: applications for endoscopic imaging. Radiology 199:321–330PubMed
18.
Zurück zum Zitat Schaefer-Prokop C, Prokop M (2002) New imaging techniques in the treatment guidelines for lung cancer. Eur Respir J [Suppl] 35:71s–83sPubMed Schaefer-Prokop C, Prokop M (2002) New imaging techniques in the treatment guidelines for lung cancer. Eur Respir J [Suppl] 35:71s–83sPubMed
19.
Zurück zum Zitat Schoepf UJ, Holzknecht N, Helmberger TK et al (2002) Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT. Radiology 222:483–490PubMed Schoepf UJ, Holzknecht N, Helmberger TK et al (2002) Subsegmental pulmonary emboli: improved detection with thin-collimation multi-detector row spiral CT. Radiology 222:483–490PubMed
20.
Zurück zum Zitat Schoepf UJ, Becker CR, Obuchowski NA et al (2001) Multi-slice computed tomography as a screening tool for colon cancer, lung cancer, and coronary artery disease. Eur Radiol 11:1975–1985CrossRefPubMed Schoepf UJ, Becker CR, Obuchowski NA et al (2001) Multi-slice computed tomography as a screening tool for colon cancer, lung cancer, and coronary artery disease. Eur Radiol 11:1975–1985CrossRefPubMed
21.
Zurück zum Zitat Schoepf UJ, Becker C, Brüning R et al (1999) Computertomographie des Abdomens mit der Mehrzeilen-Detektor Spiral CT (Computed tomography of the abdomen with multidetector-array CT). Radiologe 39:652–661PubMed Schoepf UJ, Becker C, Brüning R et al (1999) Computertomographie des Abdomens mit der Mehrzeilen-Detektor Spiral CT (Computed tomography of the abdomen with multidetector-array CT). Radiologe 39:652–661PubMed
22.
Zurück zum Zitat Summers RM, Shaw DJ, Shelhamer JH (1998) CT virtual bronchoscopy of simulated endobronchial lesions: effect of scanning, reconstruction, and display settings and potential pitfalls. Am J Roentgenol 170:947–950 Summers RM, Shaw DJ, Shelhamer JH (1998) CT virtual bronchoscopy of simulated endobronchial lesions: effect of scanning, reconstruction, and display settings and potential pitfalls. Am J Roentgenol 170:947–950
23.
Zurück zum Zitat Rubin GD (1996) Techniques of reconstruction. In: Remy Jardin M, Remy J (eds) Medical radiology spiral CT of the chest. Springer, Berlin Heidelberg New York, pp 101–127 Rubin GD (1996) Techniques of reconstruction. In: Remy Jardin M, Remy J (eds) Medical radiology spiral CT of the chest. Springer, Berlin Heidelberg New York, pp 101–127
24.
Zurück zum Zitat Ferretti GR, Bricault I, Coulomb M (2001) Virtual tools of the thorax. Eur Respir J 18:381–392PubMed Ferretti GR, Bricault I, Coulomb M (2001) Virtual tools of the thorax. Eur Respir J 18:381–392PubMed
25.
Zurück zum Zitat Schwarz Y, Mehta AC, Ernst A, Herth F, Engel A, Besser D, Becker HD (2003) Electromagnetic navigation during flexible bronchoscopy. Respiration 70:516–522CrossRefPubMed Schwarz Y, Mehta AC, Ernst A, Herth F, Engel A, Besser D, Becker HD (2003) Electromagnetic navigation during flexible bronchoscopy. Respiration 70:516–522CrossRefPubMed
Metadaten
Titel
Virtual endoscopy of the tracheo-bronchial system: sub-millimeter collimation with the 16-row multidetector scanner
verfasst von
M. Fawad Khan
Christopher Herzog
Hanns Ackermann
Thomas O. F. Wagner
Adel Maataoui
Marc Harth
Nasreddin D. Abolmaali
Volkmar Jacobi
Thomas J. Vogl
Publikationsdatum
01.08.2004
Erschienen in
European Radiology / Ausgabe 8/2004
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-004-2325-1

Weitere Artikel der Ausgabe 8/2004

European Radiology 8/2004 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.