Abstract

There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). There are no previous studies showing how to visualize polymeric bioresorbable scaffolds (BRSs) by micro-computed tomography (mCT). This study aimed to explore the feasibility of detecting polymeric BRS with 3-dimensional reconstruction of BRS images by contrast-enhanced mCT and to determine the optimal imaging settings. BRSs, made of poly-l-lactic acid (PLLA), were implanted in coronary bifurcation models. Five treatments were conducted to examine an optimal condition for imaging BRSs: Baseline treatment, samples were filled with normal saline and scanned with mCT immediately; Treatment-1, -2, -3 and -4, samples were filled with contrast medium and scanned with mCT immediately and 1, 2 and 3 h thereafter, corresponding to soaking time of contrast medium of 0, 1, 2 and 3 h. Compared to Baseline, mCT scanning completely discriminate the scaffold struts from the vascular lumen immediately after filling the samples with contrast agent but not from the vascular wall until the contrast agent soaking time was more than 2 h (Treatment-3 and -4). By setting 10–15 HU as a cut-point of CT values, the scaffold strut detectable rate at Baseline and Teatment-1, -2, -3 and -4 were 1.23 ± 0.31%, 1.65 ± 0.26%, 58.14 ± 12.84%, 97.97 ± 1.43% and 98.90 ± 0.38%, respectively (Treatment-3 vs. Treatment-2, p < 0.01); meanwhile, the success rate of 3D BRS reconstruction with high quality images at Baseline and Teatment-1, -2, -3 and -4 were 1.23%, 1.65%, 58.14%, 97.97% and 98.90%, respectively (Treatment-3 vs. Treatment-2, p < 0.01). In conclusions, reconstruction of 3D BRS images is technically feasible by contrast-enhanced mCT and soaking time of contrast agent for more than 2 h is necessary for complete separation of scaffold struts from the surrounding structures in the phantom samples.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

e.Med Innere Medizin

Kombi-Abonnement

Mit e.Med Innere Medizin erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Innere Medizin, den Premium-Inhalten der internistischen Fachzeitschriften, inklusive einer gedruckten internistischen Zeitschrift Ihrer Wahl.

Zusatzmaterial
Supplementary material 1 (AVI 2668 KB)
10554_2016_1049_MOESM1_ESM.avi
Supplementary material 2 (AVI 4182 KB)
10554_2016_1049_MOESM2_ESM.avi
Supplementary material 3 (AVI 4966 KB)
10554_2016_1049_MOESM3_ESM.avi
Supplementary material 4 (AVI 4172 KB)
10554_2016_1049_MOESM4_ESM.avi
Supplementary material 5 (AVI 4327 KB)
10554_2016_1049_MOESM5_ESM.avi
Supplementary material 6 (AVI 5194 KB)
10554_2016_1049_MOESM6_ESM.avi
Supplementary material 7 (AVI 5308 KB)
10554_2016_1049_MOESM7_ESM.avi
Supplementary material 8 (AVI 5662 KB)
10554_2016_1049_MOESM8_ESM.avi
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 5/2017

The International Journal of Cardiovascular Imaging 5/2017 Zur Ausgabe

Neu im Fachgebiet Kardiologie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Kardiologie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise