Skip to main content
Erschienen in: Journal of Digital Imaging 2/2019

31.01.2019

Volumetric Assessment of Pediatric Vascular Malformations Using a Rapid, Hand-Held Three-Dimensional Imaging System

verfasst von: Ethan J. Speir, C. Matthew Hawkins, Michael J. Weiler, Michael Briones, Rachel Swerdlin, Solomon Park, J. Brandon Dixon

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 2/2019

Einloggen, um Zugang zu erhalten

Abstract

The effect of percutaneous, surgical, and medical therapies for vascular malformations (VMs) is often difficult to quantify volumetrically using cross-sectional imaging. Volumetric measurement is often estimated with serial, expensive MRI examinations which may require sedation or anesthesia. We aim to explore whether a portable 3D scanning device is capable of rapid, accurate volumetric analysis of pediatric VMs. Using an iPad-mounted infrared scanning device, 3D scans of patient faces, arms, and legs were acquired over an 8-month study period. Proprietary software was use to perform subsequent volumetric analysis. Of a total of 30 unilateral VMs involving either the face, arms, or legs, 26 (86.7%) VMs were correctly localized by discerning the larger volume of the affected side compared to the normal contralateral side. For patients with unilateral facial VMs (n = 10), volume discrepancy between normal and affected sides differed compared with normal controls (n = 19). This was true for both absolute (60 cc ± 55 vs 15 cc ± 8, p = 0.03) as well as relative (18.1% ± 13.2 vs 4.0% ± 2.1, p = 0.008) volume discrepancy. Following treatment, two patients experienced change in leg volume discrepancy ranging from − 17.3 to − 0.4%. Using a portable 3D scanning device, we were able to rapidly and noninvasively detect and quantify volume discrepancy resulting from VMs of the face, arms, and legs. Preliminary data suggests this technology can detect volume reduction of VMs in response to therapy.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Buckmiller LM, Richter GT, Suen JY: Diagnosis and management of hemangiomas and vascular malformations of the head and neck. Oral Dis. 16(5):405–418, 2010CrossRefPubMed Buckmiller LM, Richter GT, Suen JY: Diagnosis and management of hemangiomas and vascular malformations of the head and neck. Oral Dis. 16(5):405–418, 2010CrossRefPubMed
2.
Zurück zum Zitat Alexander MD, McTaggart RA, Choudhri OA et al.: Quantitative volumetric analysis of head and neck venous and lymphatic malformations to assess response to percutaneous sclerotherapy. Acta Radiol. 57(2):205–209, 2016CrossRefPubMed Alexander MD, McTaggart RA, Choudhri OA et al.: Quantitative volumetric analysis of head and neck venous and lymphatic malformations to assess response to percutaneous sclerotherapy. Acta Radiol. 57(2):205–209, 2016CrossRefPubMed
3.
Zurück zum Zitat Caty V, Kauffmann C, Dubois J, Mansour A, Giroux MF, Oliva V, Piché N, Therasse E, Soulez G: Clinical validation of semi-automated software for volumetric and dynamic contrast enhancement analysis of soft tissue venous malformations on magnetic resonance imaging examination. Eur Radiol. 24(2):542–551, 2014CrossRefPubMed Caty V, Kauffmann C, Dubois J, Mansour A, Giroux MF, Oliva V, Piché N, Therasse E, Soulez G: Clinical validation of semi-automated software for volumetric and dynamic contrast enhancement analysis of soft tissue venous malformations on magnetic resonance imaging examination. Eur Radiol. 24(2):542–551, 2014CrossRefPubMed
4.
Zurück zum Zitat Kirkham EM, Edwards TC, Weaver EM, Balakrishnan K, Perkins JA: The lymphatic malformation function (LMF) instrument. Otolaryngol Head Neck Surg. 153(4):656–662, 2015CrossRefPubMedPubMedCentral Kirkham EM, Edwards TC, Weaver EM, Balakrishnan K, Perkins JA: The lymphatic malformation function (LMF) instrument. Otolaryngol Head Neck Surg. 153(4):656–662, 2015CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Harrison JA, Nixon MA, Fright WR, Snape L: Use of hand-held laser scanning in the assessment of facial swelling: a preliminary study. Br J Oral Maxillofac Surg. 42(1):8–17, 2004CrossRefPubMed Harrison JA, Nixon MA, Fright WR, Snape L: Use of hand-held laser scanning in the assessment of facial swelling: a preliminary study. Br J Oral Maxillofac Surg. 42(1):8–17, 2004CrossRefPubMed
6.
Zurück zum Zitat Kau CH, Cronin AJ, Richmond S: A three-dimensional evaluation of postoperative swelling following orthognathic surgery at 6 months. Plast Reconstr Surg. 119(7):2192–2199, 2007CrossRefPubMed Kau CH, Cronin AJ, Richmond S: A three-dimensional evaluation of postoperative swelling following orthognathic surgery at 6 months. Plast Reconstr Surg. 119(7):2192–2199, 2007CrossRefPubMed
7.
Zurück zum Zitat van der Meer WJ, Dijkstra PU, Visser A, Vissink A, Ren Y: Reliability and validity of measurements of facial swelling with a stereophotogrammetry optical three-dimensional scanner. Br J Oral Maxillofac Surg. 52(10):922–927, 2014CrossRefPubMed van der Meer WJ, Dijkstra PU, Visser A, Vissink A, Ren Y: Reliability and validity of measurements of facial swelling with a stereophotogrammetry optical three-dimensional scanner. Br J Oral Maxillofac Surg. 52(10):922–927, 2014CrossRefPubMed
8.
Zurück zum Zitat Hameeteman M, Verhulst AC, Vreeken RD, Maal TJ, Ulrich DJ: 3D stereophotogrammetry in upper-extremity lymphedema: an accurate diagnostic method. J Plast Reconstr Aesthet Surg. 69(2):241–247, 2016CrossRefPubMed Hameeteman M, Verhulst AC, Vreeken RD, Maal TJ, Ulrich DJ: 3D stereophotogrammetry in upper-extremity lymphedema: an accurate diagnostic method. J Plast Reconstr Aesthet Surg. 69(2):241–247, 2016CrossRefPubMed
9.
Zurück zum Zitat Cau N, Galli M, Cimolin V, Grossi A, Battarin I, Puleo G, Balzarini A, Caraceni A: Quantitative comparison between the laser scanner three-dimensional method and the circumferential method for evaluation of arm volume in patients with lymphedema. J Vasc Surg Venous Lymphat Disord. 6(1):96–103, 2018CrossRefPubMed Cau N, Galli M, Cimolin V, Grossi A, Battarin I, Puleo G, Balzarini A, Caraceni A: Quantitative comparison between the laser scanner three-dimensional method and the circumferential method for evaluation of arm volume in patients with lymphedema. J Vasc Surg Venous Lymphat Disord. 6(1):96–103, 2018CrossRefPubMed
10.
Zurück zum Zitat Mestre S, Veye F, Perez-Martin A, Behar T, Triboulet J, Berron N, Demattei C, Quéré I: Validation of lower limb segmental volumetry with hand-held, self-positioning three-dimensional laser scanner against water displacement. J Vasc Surg Venous Lymphat Disord. 2(1):39–45, 2014CrossRefPubMed Mestre S, Veye F, Perez-Martin A, Behar T, Triboulet J, Berron N, Demattei C, Quéré I: Validation of lower limb segmental volumetry with hand-held, self-positioning three-dimensional laser scanner against water displacement. J Vasc Surg Venous Lymphat Disord. 2(1):39–45, 2014CrossRefPubMed
11.
Zurück zum Zitat Yahathugoda C, Weiler MJ, Rao R, de Silva L, Dixon JB, Weerasooriya MV, Weil GJ, Budge PJ: Use of a novel portable three-dimensional imaging system to measure limb volume and circumference in patients with filarial lymphedema. Am J Trop Med Hyg. 97(6):1836–1842, 2017CrossRefPubMedPubMedCentral Yahathugoda C, Weiler MJ, Rao R, de Silva L, Dixon JB, Weerasooriya MV, Weil GJ, Budge PJ: Use of a novel portable three-dimensional imaging system to measure limb volume and circumference in patients with filarial lymphedema. Am J Trop Med Hyg. 97(6):1836–1842, 2017CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Kau CH, Hartles FR, Knox J, Zhurov AI, Richmond S: Natural head posture for measuring three-dimensional soft tissue morphology. Cardiff: FIRST Numerics, 2005 Kau CH, Hartles FR, Knox J, Zhurov AI, Richmond S: Natural head posture for measuring three-dimensional soft tissue morphology. Cardiff: FIRST Numerics, 2005
13.
Zurück zum Zitat Cignoni P, Callieri M, Corsini M, Dellepiane M, Ganovelli F, Ranzuglia G: Meshlab: an open-source mesh processing tool. Paper presented at: Eurographics Italian Chapter Conference, 2008. Cignoni P, Callieri M, Corsini M, Dellepiane M, Ganovelli F, Ranzuglia G: Meshlab: an open-source mesh processing tool. Paper presented at: Eurographics Italian Chapter Conference, 2008.
14.
Zurück zum Zitat Toma AM, Zhurov A, Playle R, Ong E, Richmond S: Reproducibility of facial soft tissue landmarks on 3D laser-scanned facial images. Orthod Craniofac Res 12(1):33–42, 2009CrossRefPubMed Toma AM, Zhurov A, Playle R, Ong E, Richmond S: Reproducibility of facial soft tissue landmarks on 3D laser-scanned facial images. Orthod Craniofac Res 12(1):33–42, 2009CrossRefPubMed
15.
Zurück zum Zitat Knoops PG, Beaumont CA, Borghi A et al.: Comparison of three-dimensional scanner systems for craniomaxillofacial imaging. J Plast Reconstr Aesthet Surg 70(4):441–449, 2017CrossRefPubMed Knoops PG, Beaumont CA, Borghi A et al.: Comparison of three-dimensional scanner systems for craniomaxillofacial imaging. J Plast Reconstr Aesthet Surg 70(4):441–449, 2017CrossRefPubMed
16.
Zurück zum Zitat Berenguer B, Burrows PE, Zurakowski D, Mulliken JB: Sclerotherapy of craniofacial venous malformations: complications and results. Plast Reconstr Surg 104(1):1–11, 1999 discussion 12-15CrossRefPubMed Berenguer B, Burrows PE, Zurakowski D, Mulliken JB: Sclerotherapy of craniofacial venous malformations: complications and results. Plast Reconstr Surg 104(1):1–11, 1999 discussion 12-15CrossRefPubMed
Metadaten
Titel
Volumetric Assessment of Pediatric Vascular Malformations Using a Rapid, Hand-Held Three-Dimensional Imaging System
verfasst von
Ethan J. Speir
C. Matthew Hawkins
Michael J. Weiler
Michael Briones
Rachel Swerdlin
Solomon Park
J. Brandon Dixon
Publikationsdatum
31.01.2019
Verlag
Springer International Publishing
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 2/2019
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-019-00183-6

Weitere Artikel der Ausgabe 2/2019

Journal of Digital Imaging 2/2019 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.