Purpose

Paired blood cultures, drawn from the catheter and a peripheral vein, used for calculation of the differential time to positivity (DTP), have been proposed for the detection of catheter-related bloodstream infections (CRBSIs). The most relevant catheter lumen to be sampled in multi-lumen central venous catheters (CVCs) has not been recommended.

Methods

Forty-four febrile neutropaenic patients, following haematopoietic stem cell transplantation (HSCT) and with multi-lumen CVCs in place, were investigated using the DTP method of blood samples drawn from every lumen of the CVC and a peripheral vein.

Results

Twelve of 44 patients (27 %) had CRBSIs, as determined by the DTP method. In 10 of 12 (83 %) febrile neutropaenic patients, after HSCT, CRBSIs originated from the CVC lumen used for parenteral nutrition and blood products only. 17 % had CRBSI originating from the other CVC lumen (p = 0.039).

Conclusion

In most patients, CRBSIs originated from the CVC lumen used for parenteral nutrition and blood products, indicating that this lumen is the main source of CRBSI. However, since 17 % of patients had CRBSIs originating from another lumen, each lumen of multi-lumen CVCs has to be considered as a potential source of CRBSI and should, ideally, be sampled in order to avoid failure in diagnostic procedures.
Literatur
1.
Zurück zum Zitat Blot F, Nitenberg G, Chachaty E, Raynard B, Germann N, Antoun S, Laplanche A, Brun-Buisson C, Tancrède C. Diagnosis of catheter-related bacteraemia: a prospective comparison of the time to positivity of hub-blood versus peripheral-blood cultures. Lancet. 1999;354:1071–7.PubMedCrossRef Blot F, Nitenberg G, Chachaty E, Raynard B, Germann N, Antoun S, Laplanche A, Brun-Buisson C, Tancrède C. Diagnosis of catheter-related bacteraemia: a prospective comparison of the time to positivity of hub-blood versus peripheral-blood cultures. Lancet. 1999;354:1071–7.PubMedCrossRef
2.
Zurück zum Zitat Machado JDC, Suen VMM, de Castro Figueiredo JF, Marchini JS. Biofilms, infection, and parenteral nutrition therapy. JPEN J Parenter Enteral Nutr. 2009;33:397–403.PubMedCrossRef Machado JDC, Suen VMM, de Castro Figueiredo JF, Marchini JS. Biofilms, infection, and parenteral nutrition therapy. JPEN J Parenter Enteral Nutr. 2009;33:397–403.PubMedCrossRef
3.
Zurück zum Zitat Craven DE. Blood cultures for community-acquired pneumonia: piecing together a mosaic for doing less. Am J Respir Crit Care Med. 2004;169:327–8.PubMedCrossRef Craven DE. Blood cultures for community-acquired pneumonia: piecing together a mosaic for doing less. Am J Respir Crit Care Med. 2004;169:327–8.PubMedCrossRef
4.
Zurück zum Zitat Dimick JB, Swoboda S, Talamini MA, Pelz RK, Hendrix CW, Lipsett PA. Risk of colonization of central venous catheters: catheters for total parenteral nutrition vs other catheters. Am J Crit Care. 2003;12:328–35.PubMed Dimick JB, Swoboda S, Talamini MA, Pelz RK, Hendrix CW, Lipsett PA. Risk of colonization of central venous catheters: catheters for total parenteral nutrition vs other catheters. Am J Crit Care. 2003;12:328–35.PubMed
5.
Zurück zum Zitat Dobbins BM, Catton JA, Kite P, McMahon MJ, Wilcox MH. Each lumen is a potential source of central venous catheter-related bloodstream infection. Crit Care Med. 2003;31:1688–90.PubMedCrossRef Dobbins BM, Catton JA, Kite P, McMahon MJ, Wilcox MH. Each lumen is a potential source of central venous catheter-related bloodstream infection. Crit Care Med. 2003;31:1688–90.PubMedCrossRef
6.
Zurück zum Zitat Guembe M, Rodríguez-Créixems M, Sánchez-Carrillo C, Pérez-Parra A, Martín-Rabadán P, Bouza E. How many lumens should be cultured in the conservative diagnosis of catheter-related bloodstream infections? Clin Infect Dis. 2010;50:1575–9.PubMedCrossRef Guembe M, Rodríguez-Créixems M, Sánchez-Carrillo C, Pérez-Parra A, Martín-Rabadán P, Bouza E. How many lumens should be cultured in the conservative diagnosis of catheter-related bloodstream infections? Clin Infect Dis. 2010;50:1575–9.PubMedCrossRef
7.
Zurück zum Zitat Hockenhull JC, Dwan K, Boland A, Smith G, Bagust A, Dündar Y, Gamble C, McLeod C, Walley T, Dickson R. The clinical effectiveness and cost-effectiveness of central venous catheters treated with anti-infective agents in preventing bloodstream infections: a systematic review and economic evaluation: abstract. Health Technol Assess. 2008;12:1. Hockenhull JC, Dwan K, Boland A, Smith G, Bagust A, Dündar Y, Gamble C, McLeod C, Walley T, Dickson R. The clinical effectiveness and cost-effectiveness of central venous catheters treated with anti-infective agents in preventing bloodstream infections: a systematic review and economic evaluation: abstract. Health Technol Assess. 2008;12:1.
8.
Zurück zum Zitat Krause R, Salzer HF, Hönigl M, Valentin T, Auner HW, Zollner-Schwetz I. Comparison of fluorescence in situ hybridisation using peptide nucleic acid probes, Gram stain/acridine orange leukocyte cytospin and differential time to positivity methods for detection of catheter-related bloodstream infection in patients after haematopoietic stem cell transplantation. Clin Microbiol Infect. 2010;16:1591–3.PubMedCrossRef Krause R, Salzer HF, Hönigl M, Valentin T, Auner HW, Zollner-Schwetz I. Comparison of fluorescence in situ hybridisation using peptide nucleic acid probes, Gram stain/acridine orange leukocyte cytospin and differential time to positivity methods for detection of catheter-related bloodstream infection in patients after haematopoietic stem cell transplantation. Clin Microbiol Infect. 2010;16:1591–3.PubMedCrossRef
9.
Zurück zum Zitat Krause R, Auner HW, Gorkiewicz G, Wölfler A, Daxboeck F, Linkesch W, Krejs GJ, Wenisch C, Reisinger EC. Detection of catheter-related bloodstream infections by the differential-time-to-positivity method and gram stain-acridine orange leukocyte cytospin test in neutropenic patients after hematopoietic stem cell transplantation. J Clin Microbiol. 2004;42:4835–7.PubMedCrossRef Krause R, Auner HW, Gorkiewicz G, Wölfler A, Daxboeck F, Linkesch W, Krejs GJ, Wenisch C, Reisinger EC. Detection of catheter-related bloodstream infections by the differential-time-to-positivity method and gram stain-acridine orange leukocyte cytospin test in neutropenic patients after hematopoietic stem cell transplantation. J Clin Microbiol. 2004;42:4835–7.PubMedCrossRef
10.
Zurück zum Zitat Mermel LA, Allon M, Bouza E, Craven DE, Flynn P, O’Grady NP, Raad II, Rijnders BJ, Sherertz RJ, Warren DK. Clinical practice guidelines for the diagnosis and management of intravascular catheter-related infection: 2009 update by the Infectious Diseases Society of America. Clin Infect Dis. 2009;49:1–45.PubMedCrossRef Mermel LA, Allon M, Bouza E, Craven DE, Flynn P, O’Grady NP, Raad II, Rijnders BJ, Sherertz RJ, Warren DK. Clinical practice guidelines for the diagnosis and management of intravascular catheter-related infection: 2009 update by the Infectious Diseases Society of America. Clin Infect Dis. 2009;49:1–45.PubMedCrossRef
11.
Zurück zum Zitat O’Grady NP, Alexander M, Burns LA, Dellinger EP, Garland J, Heard SO, Lipsett PA, Masur H, Mermel LA, Pearson ML, Raad II, Randolph AG, Rupp ME, Saint S; Healthcare Infection Control Practices Advisory Committee (HICPAC). Guidelines for the prevention of intravascular catheter-related infections. Clin Infect Dis. 2011;52:e162–93.PubMedCrossRef O’Grady NP, Alexander M, Burns LA, Dellinger EP, Garland J, Heard SO, Lipsett PA, Masur H, Mermel LA, Pearson ML, Raad II, Randolph AG, Rupp ME, Saint S; Healthcare Infection Control Practices Advisory Committee (HICPAC). Guidelines for the prevention of intravascular catheter-related infections. Clin Infect Dis. 2011;52:e162–93.PubMedCrossRef
Metadaten
Titel
Which lumen is the source of catheter-related bloodstream infection in patients with multi-lumen central venous catheters?
verfasst von
R. Krause
T. Valentin
H. Salzer
M. Hönigl
A. Valentin
H. Auner
I. Zollner-Schwetz
Publikationsdatum
01.02.2013
Verlag
Springer-Verlag
Erschienen in
Infection / Ausgabe 1/2013
Print ISSN: 0300-8126
Elektronische ISSN: 1439-0973
DOI
https://doi.org/10.1007/s15010-012-0391-x

Weitere Artikel der Ausgabe 1/2013

Infection 1/2013 Zur Ausgabe

Images in Infection

Spinal cord toxoplasmosis

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.