Why measure cardiac output?

verfasst von: Michael R Pinsky

Erschienen in: Critical Care | Ausgabe 2/2003

Einloggen, um Zugang zu erhalten

Abstract

Although cardiac output is a primary determinant of global O2 transport there are no absolute values that reflect circulatory adequacy, though very low values are of negative prognostic use. There is no agreement as to what constitutes a clinically relevant change in cardiac output. A recent clinical trial suggests that early goal-directed therapy aimed at increasing cardiac output improves survival. Thus, in some patients, measurement of cardiac output is indicated as an aid to prognosis, diagnosis and to monitor the adequacy of therapy. Gonzalez et al. compared PAC thermodilution cardiac output with indirect Fick measures of cardiac output. They found that at lower cardiac outputs (< 5 l/min) the agreement between the two techniques is good, whereas at higher flows increased differences exist between the two measures. As discussed in this commentary, this study did not address the three potential questions related to PAC monitoring of cardiac output. These questions are: can the PAC cardiac output data be used to monitor cardiac output? Do technical and physiological constraints limit the accuracy of PAC cardiac output? And; are PAC cardiac output measurement errors due to respiratory variation in pulmonary blood flow? Ways of answering each question are given.
Literatur
1.
Zurück zum Zitat Uusaro A, Russell JA, Walley KR, Takala J: Gastric-arterial PCO 2 gradient does not reflect systemic and splanchnic hemodynamics or oxygen transport after cardiac surgery. Shock 2000, 14: 13-17.CrossRefPubMed Uusaro A, Russell JA, Walley KR, Takala J: Gastric-arterial PCO 2 gradient does not reflect systemic and splanchnic hemodynamics or oxygen transport after cardiac surgery. Shock 2000, 14: 13-17.CrossRefPubMed
2.
Zurück zum Zitat LeDoux D, Astiz ME, Carpati CM, Rackow EC: Effects of perfusion pressure on tissue perfusion in septic shock. Crit Care Med 2000, 28: 2729-2732. 10.1097/00003246-200008000-00007CrossRefPubMed LeDoux D, Astiz ME, Carpati CM, Rackow EC: Effects of perfusion pressure on tissue perfusion in septic shock. Crit Care Med 2000, 28: 2729-2732. 10.1097/00003246-200008000-00007CrossRefPubMed
3.
Zurück zum Zitat Gutierrez G, Palizas F, Doglio G, Wainsztein N, Gallesio A, Pacin J, Dubin A, Schiavi E, Jorge M, Pusajo J, et al.: Gastric intramucosal pH as a therapeutic index of tissue oxygenation in critically ill patients. Lancet 1992, 339: 195-199. 10.1016/0140-6736(92)90002-KCrossRefPubMed Gutierrez G, Palizas F, Doglio G, Wainsztein N, Gallesio A, Pacin J, Dubin A, Schiavi E, Jorge M, Pusajo J, et al.: Gastric intramucosal pH as a therapeutic index of tissue oxygenation in critically ill patients. Lancet 1992, 339: 195-199. 10.1016/0140-6736(92)90002-KCrossRefPubMed
4.
Zurück zum Zitat Tuchschmidt J, Fired J, Astiz M, Rackow E: Elevation of cardiac output and oxygen delivery improves outcome in septic shock. Chest 1992, 102: 216-220.CrossRefPubMed Tuchschmidt J, Fired J, Astiz M, Rackow E: Elevation of cardiac output and oxygen delivery improves outcome in septic shock. Chest 1992, 102: 216-220.CrossRefPubMed
5.
Zurück zum Zitat Gattinoni L, Brazzi L, Pelosi P, Latini R, Tognoni G, Pesenti A, Fumagalli R: A trial of goal-oriented hemodynamic therapy in critically ill patients. N Engl J Med 1995, 333: 1025-1032. 10.1056/NEJM199510193331601CrossRefPubMed Gattinoni L, Brazzi L, Pelosi P, Latini R, Tognoni G, Pesenti A, Fumagalli R: A trial of goal-oriented hemodynamic therapy in critically ill patients. N Engl J Med 1995, 333: 1025-1032. 10.1056/NEJM199510193331601CrossRefPubMed
6.
Zurück zum Zitat Hayes MA, Timmins AC, Yau EH, Palazzo M, Hindo CJ, Watson D: Evaluation of systemic oxygen delivery in the treatment of the critically ill. N Engl J Med 1994, 330: 1717-1722. 10.1056/NEJM199406163302404CrossRefPubMed Hayes MA, Timmins AC, Yau EH, Palazzo M, Hindo CJ, Watson D: Evaluation of systemic oxygen delivery in the treatment of the critically ill. N Engl J Med 1994, 330: 1717-1722. 10.1056/NEJM199406163302404CrossRefPubMed
7.
Zurück zum Zitat Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B, Peterson E, Tomlanovich M, for the Early Goal-Directed Therapy Collaborative Group: Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001, 345: 1368-1377. 10.1056/NEJMoa010307CrossRefPubMed Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B, Peterson E, Tomlanovich M, for the Early Goal-Directed Therapy Collaborative Group: Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001, 345: 1368-1377. 10.1056/NEJMoa010307CrossRefPubMed
8.
Zurück zum Zitat Jansen JR, Schreuder JJ, Bogaard JM, van Rooyen W, Versprille A: The thermodilution technique for measurement of cardiac output during artificial ventilation. J Appl Physiol 1981, 51: 584-591.PubMed Jansen JR, Schreuder JJ, Bogaard JM, van Rooyen W, Versprille A: The thermodilution technique for measurement of cardiac output during artificial ventilation. J Appl Physiol 1981, 51: 584-591.PubMed
9.
Zurück zum Zitat Jansen JR, Schreuder JJ, Punt KD, van den Berg PC, Alfieri O: Mean cardiac output by thermodilution with a single controlled injection. Crit Care Med 2001, 29: 1868-1873. 10.1097/00003246-200110000-00003CrossRefPubMed Jansen JR, Schreuder JJ, Punt KD, van den Berg PC, Alfieri O: Mean cardiac output by thermodilution with a single controlled injection. Crit Care Med 2001, 29: 1868-1873. 10.1097/00003246-200110000-00003CrossRefPubMed
10.
Zurück zum Zitat Gonzalez J, Delafosse C, Fartoukh M, Capderou A, Straus C, Zelter M, Derenne J-P, Similowski T: Comparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patients. Crit Care 2003,7(2):171-178. 10.1186/cc1848PubMedCentralCrossRefPubMed Gonzalez J, Delafosse C, Fartoukh M, Capderou A, Straus C, Zelter M, Derenne J-P, Similowski T: Comparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patients. Crit Care 2003,7(2):171-178. 10.1186/cc1848PubMedCentralCrossRefPubMed
Metadaten
Titel
Why measure cardiac output?
verfasst von
Michael R Pinsky
Publikationsdatum
01.04.2003
Verlag
BioMed Central
Erschienen in
Critical Care / Ausgabe 2/2003
Elektronische ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc1863

Weitere Artikel der Ausgabe 2/2003

Critical Care 2/2003 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.