Skip to main content
Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology 2/2012

01.02.2012 | Glaucoma

Astigmatism and optical coherence tomography measurements

verfasst von: Young Hoon Hwang, Sang Mok Lee, Yong Yeon Kim, Jong Yeon Lee, Chungkwon Yoo

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology | Ausgabe 2/2012

Einloggen, um Zugang zu erhalten

Abstract

Background

To evaluate the effect of astigmatism change on measurement of retinal nerve fiber layer (RNFL) and macular thickness by Cirrus HD spectral-domain optical coherence tomography (Cirrus HD OCT; Carl Zeiss Meditec, Dublin, CA, USA).

Methods

A total of 30 right eyes from 30 healthy young subjects underwent RNFL and macular thickness measurements using Cirrus HD OCT. Measurements were performed at the baseline state and induced with-the-rule (WTR) and against-the-rule (ATR) astigmatism states by wearing toric soft contact lenses (+1.50 −3.25 diopter × 90° and +1.50 −3.25 diopter × 180° respectively). Dfferences in RNFL and macular thickness between the baseline state and induced astigmatism states were analyzed.

Results

Wearing toric soft contact lenses induced a mean 2.92 diopter WTR and 3.18 diopter ATR astigmatism respectively. After signal strength change adjustment, RNFL thicknesses of average, superior quadrant, 12 and 6 o’clock hour sectors decreased after induction of a WTR astigmatism (mean difference range, 1.58 to 6.88 μm); RNFL thicknesses of average, nasal, temporal quadrants, 2, 3, and 9 o’clock hour sectors decreased after induction of an ATR astigmatism (mean difference range, 0.75 to 5.11 μm) (all P values <0.05). Macular thickness was not significantly affected by astigmatism changes (all P values ≥ 0.250).

Conclusion

Although the amount of change was not substantial, RNFL thickness measured by Cirrus HD OCT was affected by astigmatism changes induced by contact lenses. It may be warranted to consider the effect of astigmatism on RNFL thickness measured by OCT in eyes with higher degrees of astigmatism.
Literatur
1.
Zurück zum Zitat Schuman JS, Hee MR, Puliafito CA, Wong C, Pedut-Kloizman T, Lin CP, Hertzmark E, Izatt JA, Swanson EA, Fujimoto JG (1995) Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. Arch Ophthalmol 113:586–596PubMedCrossRef Schuman JS, Hee MR, Puliafito CA, Wong C, Pedut-Kloizman T, Lin CP, Hertzmark E, Izatt JA, Swanson EA, Fujimoto JG (1995) Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. Arch Ophthalmol 113:586–596PubMedCrossRef
2.
Zurück zum Zitat Budenz DL, Michael A, Chang RT, McSoley J, Katz J (2005) Sensitivity and specificity of the StratusOCT for perimetric glaucoma. Ophthalmology 112:3–9PubMedCrossRef Budenz DL, Michael A, Chang RT, McSoley J, Katz J (2005) Sensitivity and specificity of the StratusOCT for perimetric glaucoma. Ophthalmology 112:3–9PubMedCrossRef
3.
Zurück zum Zitat Medeiros FA, Zangwill LM, Bowd C, Vessani RM, Susanna R Jr, Weinreb RN (2005) Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am J Ophthalmol 139:44–55PubMedCrossRef Medeiros FA, Zangwill LM, Bowd C, Vessani RM, Susanna R Jr, Weinreb RN (2005) Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography. Am J Ophthalmol 139:44–55PubMedCrossRef
4.
Zurück zum Zitat Budenz DL, Anderson DR, Varma R, Schuman J, Cantor L, Savell J, Greenfield DS, Patella VM, Quigley HA, Tielsch J (2007) Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT. Ophthalmology 114:1046–1052PubMedCrossRef Budenz DL, Anderson DR, Varma R, Schuman J, Cantor L, Savell J, Greenfield DS, Patella VM, Quigley HA, Tielsch J (2007) Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT. Ophthalmology 114:1046–1052PubMedCrossRef
5.
Zurück zum Zitat Leung CK, Mohamed S, Leung KS, Cheung CY, Chan SL, Cheng DK, Lee AK, Leung GY, Rao SK, Lam DS (2006) Retinal nerve fiber layer measurements in myopia: An optical coherence tomography study. Invest Ophthalmol Vis Sci 47:5171–5176PubMedCrossRef Leung CK, Mohamed S, Leung KS, Cheung CY, Chan SL, Cheng DK, Lee AK, Leung GY, Rao SK, Lam DS (2006) Retinal nerve fiber layer measurements in myopia: An optical coherence tomography study. Invest Ophthalmol Vis Sci 47:5171–5176PubMedCrossRef
6.
Zurück zum Zitat Hwang YH, Yoo C, Kim YY (2011) Myopic optic disc tilt and the characteristics of peripapillary retinal nerve fiber layer thickness measured by spectral-domain optical coherence tomography. J Glaucoma May 26 [Epub ahead of print]. doi:10.1097/IJG.0b013e31820719e1 Hwang YH, Yoo C, Kim YY (2011) Myopic optic disc tilt and the characteristics of peripapillary retinal nerve fiber layer thickness measured by spectral-domain optical coherence tomography. J Glaucoma May 26 [Epub ahead of print]. doi:10.​1097/​IJG.​0b013e31820719e1​
7.
Zurück zum Zitat Kang SH, Hong SW, Im SK, Lee SH, Ahn MD (2010) Effect of myopia on the thickness of the retinal nerve fiber layer measured by Cirrus HD optical coherence tomography. Invest Ophthalmol Vis Sci 51:4075–4083PubMedCrossRef Kang SH, Hong SW, Im SK, Lee SH, Ahn MD (2010) Effect of myopia on the thickness of the retinal nerve fiber layer measured by Cirrus HD optical coherence tomography. Invest Ophthalmol Vis Sci 51:4075–4083PubMedCrossRef
8.
Zurück zum Zitat Savini G, Barboni P, Parisi V, Carbonelli M (2011) The influence of axial length on retinal nerve fibre layer thickness and optic-disc size measurements by spectral-domain OCT. Br J Ophthalmol Feb 24 [Epub ahead of print]. doi:10.1136/bjo.2010.196782 Savini G, Barboni P, Parisi V, Carbonelli M (2011) The influence of axial length on retinal nerve fibre layer thickness and optic-disc size measurements by spectral-domain OCT. Br J Ophthalmol Feb 24 [Epub ahead of print]. doi:10.​1136/​bjo.​2010.​196782
9.
Zurück zum Zitat Cheung CY, Leung CK, Lin D, Pang CP, Lam DS (2008) Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography. Ophthalmology 115:1347–1351PubMedCrossRef Cheung CY, Leung CK, Lin D, Pang CP, Lam DS (2008) Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography. Ophthalmology 115:1347–1351PubMedCrossRef
10.
Zurück zum Zitat Vizzeri G, Bowd C, Medeiros FA, Weinreb RN, Zangwill LM (2009) Effect of signal strength and improper alignment on the variability of Stratus optical coherence tomography retinal nerve fiber layer thickness measurements. Am J Ophthalmol 148:249–255PubMedCrossRef Vizzeri G, Bowd C, Medeiros FA, Weinreb RN, Zangwill LM (2009) Effect of signal strength and improper alignment on the variability of Stratus optical coherence tomography retinal nerve fiber layer thickness measurements. Am J Ophthalmol 148:249–255PubMedCrossRef
11.
Zurück zum Zitat Yoo C, Suh IH, Kim YY (2009) The influence of eccentric scanning of optical coherence tomography on retinal nerve fiber layer analysis in normal subjects. Ophthalmologica 223:326–332PubMedCrossRef Yoo C, Suh IH, Kim YY (2009) The influence of eccentric scanning of optical coherence tomography on retinal nerve fiber layer analysis in normal subjects. Ophthalmologica 223:326–332PubMedCrossRef
12.
Zurück zum Zitat Hwang YH, Lee JY, Kim YY (2011) The effect of head tilt on the measurements of retinal nerve fiber layer and macular thickness by spectral-domain optical coherence tomography. Br J Ophthalmol Feb 24 [Epub ahead of print]. doi:10.1136/bjo.2010.194118 Hwang YH, Lee JY, Kim YY (2011) The effect of head tilt on the measurements of retinal nerve fiber layer and macular thickness by spectral-domain optical coherence tomography. Br J Ophthalmol Feb 24 [Epub ahead of print]. doi:10.​1136/​bjo.​2010.​194118
13.
Zurück zum Zitat Sharma N, Sony P, Gupta A, Vajpayee RB (2006) Effect of laser in situ keratomileusis and laser-assisted subepithelial keratectomy on retinal nerve fiber layer thickness. J Cataract Refract Surg 32:446–450PubMedCrossRef Sharma N, Sony P, Gupta A, Vajpayee RB (2006) Effect of laser in situ keratomileusis and laser-assisted subepithelial keratectomy on retinal nerve fiber layer thickness. J Cataract Refract Surg 32:446–450PubMedCrossRef
14.
Zurück zum Zitat Gürses-Ozden R, Liebmann JM, Schuffner D, Buxton DF, Soloway BD, Ritch R (2001) Retinal nerve fiber layer thickness remains unchanged following laser-assisted in situ keratomileusis. Am J Ophthalmol 132:512–516PubMedCrossRef Gürses-Ozden R, Liebmann JM, Schuffner D, Buxton DF, Soloway BD, Ritch R (2001) Retinal nerve fiber layer thickness remains unchanged following laser-assisted in situ keratomileusis. Am J Ophthalmol 132:512–516PubMedCrossRef
15.
Zurück zum Zitat Zangwill LM, Abunto T, Bowd C, Angeles R, Schanzlin DJ, Weinreb RN (2005) Scanning laser polarimetry retinal nerve fiber layer thickness measurements after LASIK. Ophthalmology 112:200–207PubMedCrossRef Zangwill LM, Abunto T, Bowd C, Angeles R, Schanzlin DJ, Weinreb RN (2005) Scanning laser polarimetry retinal nerve fiber layer thickness measurements after LASIK. Ophthalmology 112:200–207PubMedCrossRef
16.
Zurück zum Zitat Salchow DJ, Hwang AM, Li FY, Dziura J (2011) Effect of contact lens power on optical coherence tomography of the retinal nerve fiber layer. Invest Ophthalmol Vis Sci 52:1650–1654PubMedCrossRef Salchow DJ, Hwang AM, Li FY, Dziura J (2011) Effect of contact lens power on optical coherence tomography of the retinal nerve fiber layer. Invest Ophthalmol Vis Sci 52:1650–1654PubMedCrossRef
17.
Zurück zum Zitat Lee J, Kim NR, Kim H, Han J, Lee ES, Seong GJ, Kim CY (2010) Negative refraction power causes underestimation of peripapillary retinal nerve fibre layer thickness in spectral-domain optical coherence tomography tomography. Br J Ophthalmol Oct 17 [Epub ahead of print]. doi:10.1136/bjo.2010.186536 Lee J, Kim NR, Kim H, Han J, Lee ES, Seong GJ, Kim CY (2010) Negative refraction power causes underestimation of peripapillary retinal nerve fibre layer thickness in spectral-domain optical coherence tomography tomography. Br J Ophthalmol Oct 17 [Epub ahead of print]. doi:10.​1136/​bjo.​2010.​186536
18.
Zurück zum Zitat Langenbucher A, Viestenz A, Seitz B, Brünner H (2007) Computerized calculation scheme for retinal image size after implantation of toric intraocular lenses. Acta Ophthalmol Scand 85:92–98PubMedCrossRef Langenbucher A, Viestenz A, Seitz B, Brünner H (2007) Computerized calculation scheme for retinal image size after implantation of toric intraocular lenses. Acta Ophthalmol Scand 85:92–98PubMedCrossRef
19.
Zurück zum Zitat Hoffmann PC, Hutz WW (2010) Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes. J Cataract Refract Surg 36:1479–1485PubMedCrossRef Hoffmann PC, Hutz WW (2010) Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes. J Cataract Refract Surg 36:1479–1485PubMedCrossRef
20.
Zurück zum Zitat Fozailoff A, Tarczy-Hornoch K, Cotter S, Wen G, Lin J, Borchert M, Azen S, Varma R (2011) Prevalence of astigmatism in 6- to 72-month-old African American and Hispanic children: The Multi-Ethnic Pediatric Eye Disease Study. Ophthalmology 118:284–293PubMedCrossRef Fozailoff A, Tarczy-Hornoch K, Cotter S, Wen G, Lin J, Borchert M, Azen S, Varma R (2011) Prevalence of astigmatism in 6- to 72-month-old African American and Hispanic children: The Multi-Ethnic Pediatric Eye Disease Study. Ophthalmology 118:284–293PubMedCrossRef
21.
Zurück zum Zitat Thibos LN, Horner D (2001) Power vector analysis of the optical outcome of refractive surgery. J Cataract Refract Surg 27:80–85PubMedCrossRef Thibos LN, Horner D (2001) Power vector analysis of the optical outcome of refractive surgery. J Cataract Refract Surg 27:80–85PubMedCrossRef
22.
Zurück zum Zitat Gabriele ML, Ishikawa H, Wollstein G, Bilonick RA, Kagemann L, Wojtkowski M, Srinivasan VJ, Fujimoto JG, Duker JS, Schuman JS (2007) Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning. Invest Ophthalmol Vis Sci 48:3154–3160PubMedCrossRef Gabriele ML, Ishikawa H, Wollstein G, Bilonick RA, Kagemann L, Wojtkowski M, Srinivasan VJ, Fujimoto JG, Duker JS, Schuman JS (2007) Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning. Invest Ophthalmol Vis Sci 48:3154–3160PubMedCrossRef
23.
Zurück zum Zitat Savini G, Zanini M, Carelli V, Sadun AA, Ross-Cisneros FN, Barboni P (2005) Correlation between retinal nerve fiber layer thickness and optic nerve head size: an optical coherence tomography study. Br J Ophthalmol 89:489–492PubMedCrossRef Savini G, Zanini M, Carelli V, Sadun AA, Ross-Cisneros FN, Barboni P (2005) Correlation between retinal nerve fiber layer thickness and optic nerve head size: an optical coherence tomography study. Br J Ophthalmol 89:489–492PubMedCrossRef
24.
Zurück zum Zitat Campbell RJ, Coupland SG, Buhrmann RR, Kertes PJ (2007) Effect of eccentric and inconsistent fixation on retinal optical coherence tomography measures. Arch Ophthalmol 125:624–627PubMedCrossRef Campbell RJ, Coupland SG, Buhrmann RR, Kertes PJ (2007) Effect of eccentric and inconsistent fixation on retinal optical coherence tomography measures. Arch Ophthalmol 125:624–627PubMedCrossRef
25.
Zurück zum Zitat Sull AC, Vuong LN, Price LL, Srinivasan VJ, Gorczynska I, Fujimoto JG, Schuman JS, Duker JS (2010) Comparison of spectral/Fourier domain optical coherence tomography instruments for assessment of normal macular thickness. Retina 30:235–245PubMedCrossRef Sull AC, Vuong LN, Price LL, Srinivasan VJ, Gorczynska I, Fujimoto JG, Schuman JS, Duker JS (2010) Comparison of spectral/Fourier domain optical coherence tomography instruments for assessment of normal macular thickness. Retina 30:235–245PubMedCrossRef
26.
Zurück zum Zitat Mwanza JC, Chang RT, Budenz DL, Durbin MK, Gendy MG, Shi W, Feuer WJ (2010) Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with Cirrus HD-OCT in glaucomatous eyes. Invest Ophthalmol Vis Sci 51:5724–5730PubMedCrossRef Mwanza JC, Chang RT, Budenz DL, Durbin MK, Gendy MG, Shi W, Feuer WJ (2010) Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with Cirrus HD-OCT in glaucomatous eyes. Invest Ophthalmol Vis Sci 51:5724–5730PubMedCrossRef
Metadaten
Titel
Astigmatism and optical coherence tomography measurements
verfasst von
Young Hoon Hwang
Sang Mok Lee
Yong Yeon Kim
Jong Yeon Lee
Chungkwon Yoo
Publikationsdatum
01.02.2012
Verlag
Springer-Verlag
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 2/2012
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-011-1788-4

Weitere Artikel der Ausgabe 2/2012

Graefe's Archive for Clinical and Experimental Ophthalmology 2/2012 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Metastase in der periokulären Region

Metastasen Leitthema

Orbitale und periokuläre metastatische Tumoren galten früher als sehr selten. Aber mit der ständigen Aktualisierung von Medikamenten und Nachweismethoden für die Krebsbehandlung werden neue Chemotherapien und Strahlenbehandlungen eingesetzt. Die …

Staging und Systemtherapie bei okulären und periokulären Metastasen

Metastasen Leitthema

Metastasen bösartiger Erkrankungen sind die häufigsten Tumoren, die im Auge diagnostiziert werden. Sie treten bei ungefähr 5–10 % der Patienten mit soliden Tumoren im Verlauf der Erkrankung auf. Besonders häufig sind diese beim Mammakarzinom und …

CME: Wundheilung nach Trabekulektomie

Trabekulektomie CME-Artikel

Wird ein Glaukom chirurgisch behandelt, ist die anschließende Wundheilung von entscheidender Bedeutung. In diesem CME-Kurs lernen Sie, welche Pathomechanismen der Vernarbung zugrunde liegen, wie perioperativ therapiert und Operationsversagen frühzeitig erkannt werden kann.

„standard operating procedures“ (SOP) – Vorschlag zum therapeutischen Management bei periokulären sowie intraokulären Metastasen

Metastasen Leitthema

Peri- sowie intraokuläre Metastasen sind insgesamt gesehen selten und meist Zeichen einer fortgeschrittenen primären Tumorerkrankung. Die Therapie ist daher zumeist palliativ und selten kurativ. Zudem ist die Therapiefindung sehr individuell. Die …

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.