Background
Management of patients with co-existent coronary and carotid disease is a controversial and challenging issue [
1]. The risk for stroke after coronary artery bypass grafting (CABG), in patients with hemodynamically significant carotid stenosis is up to 30% [
2]. Therefore, in these patients a common practice is to proceed first with the restoration of cerebral perfusion and then perform the coronary revascularization. The rationale is that this strategy will reduce perioperative neurological morbidity and mortality. However, according to our knowledge, there is no published data concerning combined carotid endarterectomy (CEA) and CABG where intraoperatively the carotid procedure was acutely complicated by cardiac instability necessitating the interruption of the carotid procedure. We describe our experience using a temporary carotid shunt in order to maintain cerebral perfusion until CABG was completed and then the operation was concluded with the closure of carotid arteriotomy.
Discussion
The optimal management of patients with combined carotid and coronary artery disease remains controversial. Various strategies have been proposed such as CEA alone, or CABG alone, or staged CEA and CABG, or staged carotid artery stenting (CAS) and CABG, and simultaneous CEA and CABG, or simultaneous CAS and CABG. In the majority of these approaches the CEA or CAS precedes the CABG because it seems that reduces the perioperative neurological morbidity and mortality. We report a case where the CEA procedure was interrupted by the CABG. The carotid procedure was finished after the completion of the CABG. All these handlings were possible through a temporary carotid shunt which proved sufficient to maintain adequate cerebral perfusion for 90 minutes. To our knowledge prolonged cerebral perfusion through a shunt during on pump emergency CABG in patients with bilateral severe carotid stenosis has not been previously reported.
Besides carotid artery stenosis, other stroke risk factors during CABG, frequently quoted in the literature, are: ascending aortic atherosclerosis, previous stroke or transient ischemic attack, age, hypertension, diabetes, smoking, peripheral vascular disease, left ventricular dysfunction, left main CAD, renal failure, and increased cardiopulmonary bypass time [
3]. Our patient had the majority of these risk factors (age, left CAD, heavy smoker in the past, left ventricular dysfunction, peripheral arterial disease). The only preventive measure against stroke were the carotid shunt, which proved to be adequate, and the patent vertebral arteries.
In a recent case report the authors applied a 14 Fr cannula into the distal part of the internal carotid artery. A separate pump was connected in cannula and arterial blood at 23°C was delivered at a flow rate of 300 ml/min [
4]. Although, based on classical findings, the normal carotid artery flow rate is 133-200 ml/min, the appropriate flow rate of the active cerebral perfusion is still unclear [
5]. However, under CPB the cerebral autoregulation is severely impaired, thus a flow rate of 300 ml/min may result to hyperperfusion syndrome and cerebral hemorrhage. Moreover, differences between our technique and the previous mentioned are obvious. Our technique is less complicated, less expensive and less time consuming. Therefore, our report suggests that a carotid shunt could maintain cerebral perfusion and could provide cerebral protection for at least 90 minutes ECC in patient with high grade bilateral carotid stenosis.
Some surgeons prefer the off-pump CABG, especially in patients with severe carotid disease [
6]. Off-pump CABG certainly has many advantages and in a recent study an aorto-carotid shunt was used in patients who underwent combined CEA and CABG with satisfactory results [
7]. However, in our case this was not feasible because of patient's hemodynamic instability.
Finally, the important role of the shunt in the cerebral perfusion during CPB is enhanced by the fact that the patient was under diminished systemic pressure, moderate hypothermia and non pulsatile cerebral perfusion from the pump for 90 minutes.
Competing interests
The authors declare that they have no competing interests.
Authors' contributions
JB, AG, MP came up with original conception and design. JB, AG, MP, NK, CK reviewed the medical literature, and were major contributors in writing the manuscript. NK, CK formatted the media. All authors read and approved the final manuscript.