Skip to main content
Erschienen in: Clinical Oral Investigations 4/2005

01.12.2005 | Original Article

Comparison of in vivo visual and computer-aided tooth shade determination

verfasst von: Burkard Hugo, Tobias Witzel, Bernd Klaiber

Erschienen in: Clinical Oral Investigations | Ausgabe 4/2005

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to evaluate the performance of shade-determining devices. For the daily practitioner, it is essential to know whether modern computer-aided shade selection is reliable in everyday life. So the question of how the clinical usability of these machines could be rated has to be clarified. In the following, three actual devices available in the market were compared using a human observer's perception. The SpectroShade device (MHT Optic Research AG, 8155 Niederhasli, Switzerland), the ShadeVision device (X-Rite Co., Grandville, USA) and the Digital Shade Guide DSG4 (A. Rieth, 73614 Schorndorf, Germany) were assessed with respect to their agreement with the color perception of three examiners looking at 57 test persons (six teeth each for a total of 342). Shades were reported in Vita Classical shades. It could be demonstrated that every single human examiner showed a significantly higher agreement value (human group on average 40.2%) when compared with the remaining five methods than each computer-aided tooth shade determination device. The devices reached on average only a value of 28.6%, whereas the X-Rite ShadeVision showed a significant better result (33.2%) than the MHT SpectroShade and Rieth DSG4 (27.0 and 25.7%). Identical shade results given by all three methods of a group (group of three devices and three humans) were found to be rather low for the computer-aided devices (9.9%) compared with humans (36.7%). All six methods together agreed in 3.3% of the cases. It becomes evident that the methods—especially the computer-aided shade determination—are rather divided about the respective tooth color. Deficiencies of the instrumental as well as the visual detection become obvious. The best agreement level was performed by the human examiners. The best agreement of the evaluated devices was obtained—generally as well as among the human testers—by the X-Rite ShadeVision system, followed at a statistically significant distance by the MHT SpectroShade and the Rieth DSG4. The agreement among the examiner group was 52.9%, significantly better than that of each device compared to this group (31.3% on average). Color detection and its realization are very complex. As shown, in many cases, computer-aided color shade determination of natural teeth seems to not reflect human perception.
Literatur
1.
Zurück zum Zitat Berger-Schunn A (1994) Praktische Farbmessung: ein Buch für Anfänger, eine Gedächtnisstütze für Könner, 2nd edn. Muster-Schmidt, Göttingen Zürich Berger-Schunn A (1994) Praktische Farbmessung: ein Buch für Anfänger, eine Gedächtnisstütze für Könner, 2nd edn. Muster-Schmidt, Göttingen Zürich
2.
Zurück zum Zitat Billmeyer FW, Saltzman M (1981) Principles of color technology, 2nd edn. Wiley, New York Billmeyer FW, Saltzman M (1981) Principles of color technology, 2nd edn. Wiley, New York
3.
Zurück zum Zitat Chu SJ, Tarnow DP (2001) Digital shade analysis and verification: a case report and discussion. Pract Proced Aesthet Dent 13:129–136 (quiz 138)PubMed Chu SJ, Tarnow DP (2001) Digital shade analysis and verification: a case report and discussion. Pract Proced Aesthet Dent 13:129–136 (quiz 138)PubMed
4.
Zurück zum Zitat Chu SJ (2002) Precision shade technology: contemporary strategies in shade selection. Pract Proced Aesthet Dent 14:79–83 (quiz 84)PubMed Chu SJ (2002) Precision shade technology: contemporary strategies in shade selection. Pract Proced Aesthet Dent 14:79–83 (quiz 84)PubMed
5.
Zurück zum Zitat Culpepper WD (1970) A comparative study of shade-matching procedures. J Prosthet Dent 24:166–173PubMedCrossRef Culpepper WD (1970) A comparative study of shade-matching procedures. J Prosthet Dent 24:166–173PubMedCrossRef
6.
Zurück zum Zitat Faber FJ, Schlegel G (1995) Visuelle und messtechnische Zuordnung der Zahnfarbe. Dtsch Zahnärztl Z 9:661–663 Faber FJ, Schlegel G (1995) Visuelle und messtechnische Zuordnung der Zahnfarbe. Dtsch Zahnärztl Z 9:661–663
7.
Zurück zum Zitat Horn DJ, Bulan-Brady J, Hicks ML (1998) Sphere spectrophotometer versus human evaluation of tooth shade. J Endod 24:786–790PubMedCrossRef Horn DJ, Bulan-Brady J, Hicks ML (1998) Sphere spectrophotometer versus human evaluation of tooth shade. J Endod 24:786–790PubMedCrossRef
8.
Zurück zum Zitat Kohlmeyer B, Scheller H (2002) Zahnfarbenbestimmung mit dem PC-gestützten Messgerät “Digital Shade Guide”. Dtsch Zahnärztl Z 57:172–175 Kohlmeyer B, Scheller H (2002) Zahnfarbenbestimmung mit dem PC-gestützten Messgerät “Digital Shade Guide”. Dtsch Zahnärztl Z 57:172–175
9.
Zurück zum Zitat Mayekar SM (2001) Shades of a color. Illusion or reality? Dent Clin North Am 45:155–172PubMed Mayekar SM (2001) Shades of a color. Illusion or reality? Dent Clin North Am 45:155–172PubMed
10.
Zurück zum Zitat Paul S, Peter A, Pietrobon N, Hammerle CH (2002) Visual and spectrophotometric shade analysis of human teeth. J Dent Res 81:578–582PubMedCrossRef Paul S, Peter A, Pietrobon N, Hammerle CH (2002) Visual and spectrophotometric shade analysis of human teeth. J Dent Res 81:578–582PubMedCrossRef
11.
Zurück zum Zitat Sproull RC (2001) Color matching in dentistry. Part I. The three-dimensional nature of color. J Prosthet Dent 86:453–457CrossRefPubMed Sproull RC (2001) Color matching in dentistry. Part I. The three-dimensional nature of color. J Prosthet Dent 86:453–457CrossRefPubMed
12.
Zurück zum Zitat Wee AG, Kang EY, Johnston WM, Seghi RR (2000) Evaluating porcelain color match of different porcelain shade-matching systems. J Esthet Dent 12:271–280PubMedCrossRef Wee AG, Kang EY, Johnston WM, Seghi RR (2000) Evaluating porcelain color match of different porcelain shade-matching systems. J Esthet Dent 12:271–280PubMedCrossRef
13.
Zurück zum Zitat Wyszeki G, Stiles WS (1982) Color science, 2nd edn. Wiley, New York Wyszeki G, Stiles WS (1982) Color science, 2nd edn. Wiley, New York
14.
Zurück zum Zitat Yap AU, Sim CP, Loh WL, Teo JH (1999) Human-eye versus computerized color matching. Oper Dent 24:358–363PubMed Yap AU, Sim CP, Loh WL, Teo JH (1999) Human-eye versus computerized color matching. Oper Dent 24:358–363PubMed
Metadaten
Titel
Comparison of in vivo visual and computer-aided tooth shade determination
verfasst von
Burkard Hugo
Tobias Witzel
Bernd Klaiber
Publikationsdatum
01.12.2005
Verlag
Springer-Verlag
Erschienen in
Clinical Oral Investigations / Ausgabe 4/2005
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-005-0014-3

Weitere Artikel der Ausgabe 4/2005

Clinical Oral Investigations 4/2005 Zur Ausgabe

Calendar of Events

Calendar of Events

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.