Abstract

This study was conducted to longitudinally compare a new floating platform mobile-bearing (MB) prosthesis with an established fixed-bearing (FB) system with respect to early clinical outcomes in patients with bilateral TKAs using the MB prosthesis in one knee and the FB prosthesis in the other. Clinical outcomes (ROM, AKS and WOMAC scores, and side preference), evaluated at 6, 12 and 24 months postoperatively, were compared between knees fitted with the MB prosthesis (e.motion-FP) or the FB prosthesis (Genesis II) in 66 patients who underwent bilateral TKA. In addition, the same comparisons between the knees fitted with the MB prosthesis and the knees with the FB prosthesis were made separately in the subgroup of 33 patients implanted with a cruciate retaining FB (FB-CR) prosthesis and the other subgroup of 33 patients with a posteriorly stabilized FB (FB-PS) prosthesis in a knee. The floating platform MB prosthesis achieved comparable clinical outcomes to the FB prosthesis. No significant differences were found between the FB- and MB-implanted sides at any time with respect to the outcome scales, and temporal patterns were similar. However, comparisons of FB-CR and FB-PS patient groups revealed different temporal patterns. In the FB-CR group, most outcome scales were improved at 6 months, peaked at 12 months and then remained at this level at 24 months. In contrast, outcomes in the FB-PS group improved much faster to almost peak at 6 months, and then remained at this level. In the FB-CR group, more patients preferred the knee with fitted with a MB prosthesis at 6 months. In contrast, in the FB-PS group, no side preference for the MB prosthesis was observed, and more patients preferred knees implanted with the FB prosthesis at 12 and 24 months. This study demonstrates that this new mobile-bearing prosthesis, designed as a floating platform, provides satisfactory clinical performances that are comparable to those achieved using the established fixed-bearing prosthesis in terms of clinical outcomes.
Literatur
1.
Zurück zum Zitat Aglietti P, Baldini A, Buzzi R, Lup D, De Luca L (2005) Comparison of mobile-bearing and fixed-bearing total knee arthroplasty: a prospective randomized study. J Arthroplasty 20:145–153CrossRefPubMed Aglietti P, Baldini A, Buzzi R, Lup D, De Luca L (2005) Comparison of mobile-bearing and fixed-bearing total knee arthroplasty: a prospective randomized study. J Arthroplasty 20:145–153CrossRefPubMed
2.
Zurück zum Zitat Beard DJ, Pandit H, Price AJ, Butler-Manuel PA, Dodd CA, Murray DW, Goodfellow JW (2007) Introduction of a new mobile-bearing total knee prosthesis—minimum three year follow-up of an RCT comparing it with a fixed-bearing device. Knee 14:448–451CrossRefPubMed Beard DJ, Pandit H, Price AJ, Butler-Manuel PA, Dodd CA, Murray DW, Goodfellow JW (2007) Introduction of a new mobile-bearing total knee prosthesis—minimum three year follow-up of an RCT comparing it with a fixed-bearing device. Knee 14:448–451CrossRefPubMed
3.
Zurück zum Zitat Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15:1833–1840PubMed Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW (1988) Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol 15:1833–1840PubMed
4.
Zurück zum Zitat Bhan S, Malhotra R, Kiran EK, Shukla S, Bijjawara M (2005) A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years. J Bone Joint Surg Am 87:2290–2296CrossRefPubMed Bhan S, Malhotra R, Kiran EK, Shukla S, Bijjawara M (2005) A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years. J Bone Joint Surg Am 87:2290–2296CrossRefPubMed
5.
Zurück zum Zitat Biau D, Mullins MM, Judet T, Piriou P (2006) Mobile versus fixed-bearing total knee arthroplasty: mid-term comparative clinical results of 216 prostheses. Knee Surg Sports Traumatol Arthrosc 14:927–933CrossRefPubMed Biau D, Mullins MM, Judet T, Piriou P (2006) Mobile versus fixed-bearing total knee arthroplasty: mid-term comparative clinical results of 216 prostheses. Knee Surg Sports Traumatol Arthrosc 14:927–933CrossRefPubMed
6.
Zurück zum Zitat Bourne RB, Laskin RS, Guenin JS (2007) Ten year results of the first 100 Genesis II total knee replacement procedures. Orthopedics 30:S83–S85 Bourne RB, Laskin RS, Guenin JS (2007) Ten year results of the first 100 Genesis II total knee replacement procedures. Orthopedics 30:S83–S85
7.
Zurück zum Zitat Chew JT, Stewart NJ, Hanssen AD, Luo ZP, Rand JA, An KN (1997) Differences in patellar tracking and knee kinematics among three different total knee designs. Clin Orthop Relat Res 345:87–98CrossRefPubMed Chew JT, Stewart NJ, Hanssen AD, Luo ZP, Rand JA, An KN (1997) Differences in patellar tracking and knee kinematics among three different total knee designs. Clin Orthop Relat Res 345:87–98CrossRefPubMed
8.
Zurück zum Zitat Crowninshield RD, Rosenberg AG, Sporer SM (2006) Changing demographics of patients with total joint replacement. Clin Orthop Relat Res 443:266–272CrossRefPubMed Crowninshield RD, Rosenberg AG, Sporer SM (2006) Changing demographics of patients with total joint replacement. Clin Orthop Relat Res 443:266–272CrossRefPubMed
9.
Zurück zum Zitat Dennis DA, Komistek RD (2006) Mobile-bearing total knee arthroplasty: design factors in minimizing wear. Clin Orthop Relat Res 452:70–77CrossRefPubMed Dennis DA, Komistek RD (2006) Mobile-bearing total knee arthroplasty: design factors in minimizing wear. Clin Orthop Relat Res 452:70–77CrossRefPubMed
10.
Zurück zum Zitat Geiger F, Mau H, Kruger M, Thomsen M (2008) Comparison of a new mobile-bearing total knee prosthesis with a fixed-bearing prosthesis: a matched pair analysis. Arch Orthop Trauma Surg 128:285–291CrossRefPubMed Geiger F, Mau H, Kruger M, Thomsen M (2008) Comparison of a new mobile-bearing total knee prosthesis with a fixed-bearing prosthesis: a matched pair analysis. Arch Orthop Trauma Surg 128:285–291CrossRefPubMed
11.
Zurück zum Zitat Haas SB, Cook S, Beksac B (2004) Minimally invasive total knee replacement through a mini midvastus approach: a comparative study. Clin Orthop Relat Res 428:68–73CrossRefPubMed Haas SB, Cook S, Beksac B (2004) Minimally invasive total knee replacement through a mini midvastus approach: a comparative study. Clin Orthop Relat Res 428:68–73CrossRefPubMed
12.
Zurück zum Zitat Hartford JM, Hunt T, Kaufer H (2001) Low contact stress mobile bearing total knee arthroplasty: results at 5 to 13 years. J Arthroplasty 16:977–983CrossRefPubMed Hartford JM, Hunt T, Kaufer H (2001) Low contact stress mobile bearing total knee arthroplasty: results at 5 to 13 years. J Arthroplasty 16:977–983CrossRefPubMed
13.
Zurück zum Zitat Heim CS, Postak PD, Plaxton NA, Greenwald AS (2001) Classification of mobile-bearing knee designs: mobility and constraint. J Bone Joint Surg Am 83:32–37PubMed Heim CS, Postak PD, Plaxton NA, Greenwald AS (2001) Classification of mobile-bearing knee designs: mobility and constraint. J Bone Joint Surg Am 83:32–37PubMed
14.
Zurück zum Zitat Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14PubMed
15.
Zurück zum Zitat Kim YH, Kim DY, Kim JS (2007) Simultaneous mobile- and fixed-bearing total knee replacement in the same patients. A prospective comparison of mid-term outcomes using a similar design of prosthesis. J Bone Joint Surg Br 89:904–910PubMed Kim YH, Kim DY, Kim JS (2007) Simultaneous mobile- and fixed-bearing total knee replacement in the same patients. A prospective comparison of mid-term outcomes using a similar design of prosthesis. J Bone Joint Surg Br 89:904–910PubMed
16.
Zurück zum Zitat Kim YH, Yoon SH, Kim JS (2007) The long-term results of simultaneous fixed-bearing and mobile-bearing total knee replacements performed in the same patient. J Bone Joint Surg Br 89:1317–1323CrossRefPubMed Kim YH, Yoon SH, Kim JS (2007) The long-term results of simultaneous fixed-bearing and mobile-bearing total knee replacements performed in the same patient. J Bone Joint Surg Br 89:1317–1323CrossRefPubMed
17.
Zurück zum Zitat Kim TH, Lee DH, Bin SI (2008) The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Joint Surg Br 90:1304–1310CrossRefPubMed Kim TH, Lee DH, Bin SI (2008) The NexGen LPS-flex to the knee prosthesis at a minimum of three years. J Bone Joint Surg Br 90:1304–1310CrossRefPubMed
18.
Zurück zum Zitat Kim TK, Chang CB, Kang YG, Kim SJ, Seong SC (2009) Causes and predictors of patient’s dissatisfaction after uncomplicated total knee arthroplasty. J Arthroplasty 24:263–271CrossRefPubMed Kim TK, Chang CB, Kang YG, Kim SJ, Seong SC (2009) Causes and predictors of patient’s dissatisfaction after uncomplicated total knee arthroplasty. J Arthroplasty 24:263–271CrossRefPubMed
19.
Zurück zum Zitat Kop AM, Swarts E (2007) Quantification of polyethylene degradation in mobile bearing knees: a retrieval analysis of the Anterior-Posterior-Glide (APG) and Rotating Platform (RP) Low Contact Stress (LCS) knee. Acta Orthop 78:364–370CrossRefPubMed Kop AM, Swarts E (2007) Quantification of polyethylene degradation in mobile bearing knees: a retrieval analysis of the Anterior-Posterior-Glide (APG) and Rotating Platform (RP) Low Contact Stress (LCS) knee. Acta Orthop 78:364–370CrossRefPubMed
20.
Zurück zum Zitat Kurtz S, Mowat F, Ong K, Chan N, Lau E, Halpern M (2005) Prevalence of primary and revision total hip and knee arthroplasty in the united states from 1990 through 2002. J Bone Joint Surg Am 87:1487–1497CrossRefPubMed Kurtz S, Mowat F, Ong K, Chan N, Lau E, Halpern M (2005) Prevalence of primary and revision total hip and knee arthroplasty in the united states from 1990 through 2002. J Bone Joint Surg Am 87:1487–1497CrossRefPubMed
21.
Zurück zum Zitat Ladermann A, Lubbeke A, Stern R, Riand N, Fritschy D (2008) Fixed-bearing versus mobile-bearing total knee arthroplasty: a prospective randomised, clinical and radiological study with mid-term results at 7 years. Knee 15:206–210CrossRefPubMed Ladermann A, Lubbeke A, Stern R, Riand N, Fritschy D (2008) Fixed-bearing versus mobile-bearing total knee arthroplasty: a prospective randomised, clinical and radiological study with mid-term results at 7 years. Knee 15:206–210CrossRefPubMed
22.
Zurück zum Zitat Laskin RS (2001) Lateral release rates after total knee arthroplasty. Clin Orthop Relat Res 392:88–93CrossRefPubMed Laskin RS (2001) Lateral release rates after total knee arthroplasty. Clin Orthop Relat Res 392:88–93CrossRefPubMed
23.
Zurück zum Zitat McEwen HM, Barnett PI, Bell CJ, Farrar R, Auger DD, Stone MH, Fisher J (2005) The influence of design, materials and kinematics on the in vitro wear of total knee replacements. J Biomech 38:357–365CrossRefPubMed McEwen HM, Barnett PI, Bell CJ, Farrar R, Auger DD, Stone MH, Fisher J (2005) The influence of design, materials and kinematics on the in vitro wear of total knee replacements. J Biomech 38:357–365CrossRefPubMed
24.
Zurück zum Zitat Minoda Y, Kobayashi A, Iwaki H, Miyaguchi M, Kadoya Y, Ohashi H, Takaoka K (2004) Characteristics of polyethylene wear particles isolated from synovial fluid after mobile-bearing and posterior-stabilized total knee arthroplasties. J Biomed Mater Res B Appl Biomater 71:1–6CrossRefPubMed Minoda Y, Kobayashi A, Iwaki H, Miyaguchi M, Kadoya Y, Ohashi H, Takaoka K (2004) Characteristics of polyethylene wear particles isolated from synovial fluid after mobile-bearing and posterior-stabilized total knee arthroplasties. J Biomed Mater Res B Appl Biomater 71:1–6CrossRefPubMed
25.
Zurück zum Zitat Pagnano MW, Trousdale RT, Stuart MJ, Hanssen AD, Jacofsky DJ (2004) Rotating platform knees did not improve patellar tracking: a prospective, randomized study of 240 primary total knee arthroplasties. Clin Orthop Relat Res 428:221–227CrossRefPubMed Pagnano MW, Trousdale RT, Stuart MJ, Hanssen AD, Jacofsky DJ (2004) Rotating platform knees did not improve patellar tracking: a prospective, randomized study of 240 primary total knee arthroplasties. Clin Orthop Relat Res 428:221–227CrossRefPubMed
26.
Zurück zum Zitat Park KK, Chang CB, Kang YG, Seong SC, Kim TK (2007) Correlation of maximum flexion with clinical outcome after total knee replacement in Asian patients. J Bone Joint Surg Br 89:604–608CrossRefPubMed Park KK, Chang CB, Kang YG, Seong SC, Kim TK (2007) Correlation of maximum flexion with clinical outcome after total knee replacement in Asian patients. J Bone Joint Surg Br 89:604–608CrossRefPubMed
27.
Zurück zum Zitat Price AJ, Rees JL, Beard D, Juszczak E, Carter S, White S, de Steiger R, Dodd CA, Gibbons M, McLardy-Smith P, Goodfellow JW, Murray DW (2003) A mobile-bearing total knee prosthesis compared with a fixed-bearing prosthesis. A multicentre single-blind randomised controlled trial. J Bone Joint Surg Br 85:62–67CrossRefPubMed Price AJ, Rees JL, Beard D, Juszczak E, Carter S, White S, de Steiger R, Dodd CA, Gibbons M, McLardy-Smith P, Goodfellow JW, Murray DW (2003) A mobile-bearing total knee prosthesis compared with a fixed-bearing prosthesis. A multicentre single-blind randomised controlled trial. J Bone Joint Surg Br 85:62–67CrossRefPubMed
28.
Zurück zum Zitat Rees JL, Beard DJ, Price AJ, Gill HS, McLardy-Smith P, Dodd CA, Murray DW (2005) Real in vivo kinematic differences between mobile-bearing and fixed-bearing total knee arthroplasties. Clin Orthop Relat Res 432:204–209CrossRefPubMed Rees JL, Beard DJ, Price AJ, Gill HS, McLardy-Smith P, Dodd CA, Murray DW (2005) Real in vivo kinematic differences between mobile-bearing and fixed-bearing total knee arthroplasties. Clin Orthop Relat Res 432:204–209CrossRefPubMed
29.
Zurück zum Zitat Restrepo C, Parvizi J, Dietrich T, Einhorn TA (2007) Safety of simultaneous bilateral total knee arthroplasty. A meta-analysis. J Bone Joint Surg Am 89:1220–1226CrossRefPubMed Restrepo C, Parvizi J, Dietrich T, Einhorn TA (2007) Safety of simultaneous bilateral total knee arthroplasty. A meta-analysis. J Bone Joint Surg Am 89:1220–1226CrossRefPubMed
30.
Zurück zum Zitat Ridgeway S, Moskal JT (2004) Early instability with mobile-bearing total knee arthroplasty: a series of 25 cases. J Arthroplasty 19:686–693CrossRefPubMed Ridgeway S, Moskal JT (2004) Early instability with mobile-bearing total knee arthroplasty: a series of 25 cases. J Arthroplasty 19:686–693CrossRefPubMed
31.
Zurück zum Zitat Seon JK, Song EK, Lee JY (2005) Comparison of range of motion of high-flexion prosthesis and mobile-bearing prosthesis in total knee arthroplasty. Orthopedics 28:1247–1250 Seon JK, Song EK, Lee JY (2005) Comparison of range of motion of high-flexion prosthesis and mobile-bearing prosthesis in total knee arthroplasty. Orthopedics 28:1247–1250
32.
Zurück zum Zitat Watanabe T, Tomita T, Fujii M, Hashimoto J, Sugamoto K, Yoshikawa H (2005) Comparison between mobile-bearing and fixed-bearing knees in bilateral total knee replacements. Int Orthop 29:179–181CrossRefPubMed Watanabe T, Tomita T, Fujii M, Hashimoto J, Sugamoto K, Yoshikawa H (2005) Comparison between mobile-bearing and fixed-bearing knees in bilateral total knee replacements. Int Orthop 29:179–181CrossRefPubMed
33.
Zurück zum Zitat Woolson ST, Northrop GD (2004) Mobile- vs. fixed-bearing total knee arthroplasty: a clinical and radiologic study. J Arthroplasty 19:135–140CrossRefPubMed Woolson ST, Northrop GD (2004) Mobile- vs. fixed-bearing total knee arthroplasty: a clinical and radiologic study. J Arthroplasty 19:135–140CrossRefPubMed
Metadaten
Titel
Early clinical outcomes of floating platform mobile-bearing TKA: longitudinal comparison with fixed-bearing TKA
verfasst von
Tae Kyun Kim
Chong Bum Chang
Yeon Gwi Kang
Byung June Chung
Hyung Joon Cho
Sang Cheol Seong
Publikationsdatum
01.07.2010
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 7/2010
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-009-0985-8

Weitere Artikel der Ausgabe 7/2010

Knee Surgery, Sports Traumatology, Arthroscopy 7/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Knie-TEP: Kein Vorteil durch antibiotikahaltigen Knochenzement

29.05.2024 Periprothetische Infektionen Nachrichten

Zur Zementierung einer Knie-TEP wird in Deutschland zu über 98% Knochenzement verwendet, der mit einem Antibiotikum beladen ist. Ob er wirklich besser ist als Zement ohne Antibiotikum, kann laut Registerdaten bezweifelt werden.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.