Ausgabe 2/2005
Inhalt (35 Artikel)
Computer-assisted detection of pulmonary nodules: evaluation of diagnostic performance using an expert knowledge-based detection system with variable reconstruction slice thickness settings
Katharina Marten, Andreas Grillhösl, Tobias Seyfarth, Silvia Obenauer, Ernst J. Rummeny, Christoph Engelke
Scoring CT/HRCT findings among asbestos-exposed workers: effects of patient’s age, body mass index and common laboratory test results
T. Vehmas, L. Kivisaari, M. S. Huuskonen, M. S. Jaakkola
Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging
Young Kon Kim, Jeong Min Lee, Chong Soo Kim, Gyung Ho Chung, Chan Young Kim, In Hee Kim
Well-differentiated adenocarcinoma of the gallbladder with intratumoral cystic components due to abundant mucin production: a mimicker of adenomyomatosis
Kengo Yoshimitsu, Hiroyuki Irie, Hitoshi Aibe, Tsuyoshi Tajima, Akihiro Nishie, Yoshiki Asayama, Kunishige Matake, Kouji Yamaguchi, Shuji Matsuura, Hiroshi Honda
A tamponade leading to death after radiofrequency ablation of hepatocellular carcinoma
Ahmed Moumouh, Jérôme Hannequin, Carine Chagneau, Fatima Rayeh, Arnaud Jeanny, Alexandre Weber-Holtzscherer, Jean-Pierre Tasu
Multidetector CT enteroclysis: comparison of the reading performance for axial and coronal views
Sabine Schmidt, Patrick Chevallier, Marc Chalaron, Bertrand Bessoud, Francis R. Verdun, Philippe Frascarolo, Pierre Schnyder, Alban Denys
Automated mass detection in contrast-enhanced CT colonography: an approach based on contrast and volume
W. Luboldt, C. Tryon, M. Kroll, T. L. Toussaint, K. Holzer, N. Hoepffner, T. J. Vogl
Gastrointestinal complications of bariatric Roux-en-Y gastric bypass surgery
Kumaresan Sandrasegaran, Arumugam Rajesh, Chandana Lall, Gerardo A. Gomez, John C. Lappas, Dean D. Maglinte
CT and MR findings of a retrorectal cystic hamartoma confused with an adnexal mass on ultrasound
L. Menassa-Moussa, H. Kanso, A. Checrallah, J. Abboud, M. Ghossain
Diffusion tensor imaging of partial intractable epilepsy
Anne Dumas de la Roque, Catherine Oppenheim, Francine Chassoux, Sebastian Rodrigo, Frédéric Beuvon, Catherine Daumas-Duport, Bertrand Devaux, Jean-François Meder
Screening for cerebellopontine angle tumors: is a CISS sufficient?
Einar Goebell, Thorsten Ries, Thomas Kucinski, Ullrich Grzyska, Bernd Eckert, Jens Fiehler, Britta Eickhoff, Jan Regelsberger, Christoph Koch, Herrmann Zeumer
Real time fMRI: a tool for the routine presurgical localisation of the motor cortex
M. Möller, M. Freund, C. Greiner, W. Schwindt, C. Gaus, W. Heindel
Coronary arteries: assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time
Xavier L. Hamoir, Thomas Flohr, Vincent Hamoir, Laurent Labaki, Jean-Yves Tricquet, Alain Duhamel, Jacques Kirsch
MDCT of the proximal anastomoses created by nitinol implants in coronary artery bypass grafting: a retrospective two-observer evaluation
M. Fawad Khan, Christopher Herzog, Kai Landenberger, Sven Martens, Adel Maataoui, Hanns Ackermann, Markus Dietrich, Anton Moritz, Thomas J. Vogl
Assessment of right ventricular function by 16-detector-row CT: comparison with magnetic resonance imaging
K. Koch, F. Oellig, K. Oberholzer, P. Bender, P. Kunz, P. Mildenberger, U. Hake, K.-F. Kreitner, M. Thelen
Noninvasive measurements of cardiac high-energy phosphate metabolites in dilated cardiomyopathy by using 31P spectroscopic chemical shift imaging
A. Hansch, R. Rzanny, J.-P. Heyne, U. Leder, J. R. Reichenbach, W. A. Kaiser
Lung MRI at 3.0 T: a comparison of helical CT and high-field MRI in the detection of diffuse lung disease
G. Lutterbey, J. Gieseke, M. von Falkenhausen, N. Morakkabati, H. Schild
Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience
Konstantin Nikolaou, Thomas Flohr, Karl Stierstorfer, Christoph R. Becker, Maximilian F. Reiser
Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose
B. Wintersperger, T. Jakobs, P. Herzog, S. Schaller, K. Nikolaou, C. Suess, C. Weber, M. Reiser, C. Becker
Improved diagnosis of vascular dissection by ultrasound B-flow: a comparison with color-coded Doppler and power Doppler sonography
D.-A. Clevert, N. Rupp, M. Reiser, E. M. Jung
Abdominal aortic aneurysms: virtual imaging and analysis through a remote web server
Emanuele Neri, Irene Bargellini, Michael Rieger, Andrea Giachetti, Claudio Vignali, Massimiliano Tuveri, Werner Jaschke, Carlo Bartolozzi
Multi-slice spiral CT imaging after surgical treatment of aortic coarctation
Ulrich Baum, Katharina Anders, Dieter Ropers, Anton Noemayr, Axel Schmid, Theresa Seeliger, Helmut Singer, Werner G. Daniel, Werner Bautz, Stephan Achenbach
Sonographic findings in stress fractures of the lower limb: preliminary findings
Gerd Bodner, Bernhard Stöckl, Anke Fierlinger, Michael Schocke, Maria Bernathova
Percutaneous vertebroplasty immediately relieves pain of osteoporotic vertebral compression fractures and prevents prolonged immobilization of patients
Kiyokazu Kobayashi, Keiji Shimoyama, Keiya Nakamura, Kiyoshi Murata
Detection of dysbaric osteonecrosis in military divers using magnetic resonance imaging
H. Bolte, A. Koch, K. Tetzlaff, E. Bettinghausen, M. Heller, M. Reuter
Quantification of C2 cervical spine rotatory fixation by X-ray, MRI and CT
Georg Gradl, Tamara Maier-Bosse, Randolph Penning, Axel Stäbler
Liposarcoma subtypes: identification with computed tomography and ultrasound-guided percutaneous needle biopsy
Paul Nikolaidis, Stuart G. Silverman, Edmund S. Cibas, Eric vanSonnenberg, Frank J. Rybicki, Judith B. Manola, Kemal Tuncali, Steven H. Karshbaum, Samuel Singer, Christopher D. M. Fletcher, George D. Demetri
Early changes in experimental osteoarthritis using the Pond-Nuki dog model: technical procedure and initial results of in vivo MR imaging
Martin Libicher, Mate Ivancic, Volker Hoffmann, Wolfram Wenz