Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 8/2010

01.08.2010 | Arthroscopy and Sports Medicine

Hybrid hamstring graft tibial fixation in anterior cruciate ligament reconstruction

verfasst von: Miroslav Z. Milankov, Natasa Miljkovic, Natasa Janjic

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 8/2010

Einloggen, um Zugang zu erhalten

Abstract

Tibial fixation of the anterior cruciate ligament hamstring tendon graft is commonly considered more problematic than femoral fixation. When interference screws are used for tibial hamstring tendon graft fixation, graft sometimes looses its tension, so a hybrid fixation (more than one method of fixation) must be applied. Biomechanical studies show that an implementation of interference screws combined with different indirect distal hamstring tendon fixation techniques can withstand much higher tearing forces when compared with one type of fixation. We made a technique of hybrid tibial fixation of the hamstring graft using round interference screws and an additional bi-cortical 4.5-mm diameter screw with a modified head that allows control over the initial tension of the graft.
Literatur
1.
Zurück zum Zitat Brand J Jr, Weiler A, Caborn DNM, Brown CH Jr, Johnson DL (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28:761–774PubMed Brand J Jr, Weiler A, Caborn DNM, Brown CH Jr, Johnson DL (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28:761–774PubMed
2.
Zurück zum Zitat Giurea M, Zorilla P, Amis AA, Aichroth P (1999) Comparative pull-out and cyclic loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction. Am J Sports Med 27:621–625PubMed Giurea M, Zorilla P, Amis AA, Aichroth P (1999) Comparative pull-out and cyclic loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction. Am J Sports Med 27:621–625PubMed
3.
Zurück zum Zitat Ishibashi Y, Rudy TW, Livesay GA, Stone JD, Fu FH, Woo SL (1997) The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: Evaluation using a robotic testing system. Arthroscopy 13:177–182CrossRefPubMed Ishibashi Y, Rudy TW, Livesay GA, Stone JD, Fu FH, Woo SL (1997) The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: Evaluation using a robotic testing system. Arthroscopy 13:177–182CrossRefPubMed
4.
Zurück zum Zitat Lee CH, Huang GS, Chao KH, Wu SS, Chen Q (2005) Differential pretensions of a flexor tendon graft for anterior cruciate ligament reconstruction: a biomechanical comparison in a porcine knee model. Arthroscopy 21:540–546CrossRefPubMed Lee CH, Huang GS, Chao KH, Wu SS, Chen Q (2005) Differential pretensions of a flexor tendon graft for anterior cruciate ligament reconstruction: a biomechanical comparison in a porcine knee model. Arthroscopy 21:540–546CrossRefPubMed
5.
Zurück zum Zitat Magen HE, Howell SM, Hull ML (1999) Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am J Sports Med 27:35–43PubMed Magen HE, Howell SM, Hull ML (1999) Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am J Sports Med 27:35–43PubMed
6.
Zurück zum Zitat Melby A III, Noble JS, Askew MJ, Boom AA, Hurst FW (1991) The effects of graft tensioning on the laxity and kinematics of the anterior cruciate ligament reconstructed knee. Arthroscopy 7:257–266CrossRefPubMed Melby A III, Noble JS, Askew MJ, Boom AA, Hurst FW (1991) The effects of graft tensioning on the laxity and kinematics of the anterior cruciate ligament reconstructed knee. Arthroscopy 7:257–266CrossRefPubMed
7.
Zurück zum Zitat Scheffler SU, Südkamp NP, Göckenjan A, Hoffmann RF, Weiler A (2002) Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: the impact of fixation level and fixation method under cyclic loading. Arthroscopy 18:304–315CrossRefPubMed Scheffler SU, Südkamp NP, Göckenjan A, Hoffmann RF, Weiler A (2002) Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: the impact of fixation level and fixation method under cyclic loading. Arthroscopy 18:304–315CrossRefPubMed
8.
Zurück zum Zitat Tetsumura S, Fujita A, Nakajima M, Abe M (2006) Biomechanical comparison of different fixation methods on the tibial side in anterior cruciate ligament reconstruction: a biomechanical study in porcine tibial bone. J Orthop Sci 11:278–282CrossRefPubMed Tetsumura S, Fujita A, Nakajima M, Abe M (2006) Biomechanical comparison of different fixation methods on the tibial side in anterior cruciate ligament reconstruction: a biomechanical study in porcine tibial bone. J Orthop Sci 11:278–282CrossRefPubMed
9.
Zurück zum Zitat Weimann A, Rodieck M, Zantop T, Hassenpflug J, Petersen W (2005) Primary stability of hamstring graft fixation with biodegradable suspension versus interference screws. Arthroscopy 21:266–274CrossRefPubMed Weimann A, Rodieck M, Zantop T, Hassenpflug J, Petersen W (2005) Primary stability of hamstring graft fixation with biodegradable suspension versus interference screws. Arthroscopy 21:266–274CrossRefPubMed
10.
Zurück zum Zitat Yoo JC, Ahn JH, Kim JH, Kim BK, Choi KW, Bae TS, Lee CY (2006) Biomechanical testing of hybrid hamstring graft tibial fixation in anterior cruciate ligament reconstruction. Knee 13:455–459CrossRefPubMed Yoo JC, Ahn JH, Kim JH, Kim BK, Choi KW, Bae TS, Lee CY (2006) Biomechanical testing of hybrid hamstring graft tibial fixation in anterior cruciate ligament reconstruction. Knee 13:455–459CrossRefPubMed
11.
Zurück zum Zitat Zantop T, Weimann A, Schmidtko R, Herbort M, Raschke MJ, Petersen W (2006) Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d, l-lactide, and poly-d, l-lactide–tricalcium phosphate screws. Arthroscopy 22:1204–1210CrossRefPubMed Zantop T, Weimann A, Schmidtko R, Herbort M, Raschke MJ, Petersen W (2006) Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d, l-lactide, and poly-d, l-lactide–tricalcium phosphate screws. Arthroscopy 22:1204–1210CrossRefPubMed
Metadaten
Titel
Hybrid hamstring graft tibial fixation in anterior cruciate ligament reconstruction
verfasst von
Miroslav Z. Milankov
Natasa Miljkovic
Natasa Janjic
Publikationsdatum
01.08.2010
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 8/2010
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-010-1124-1

Weitere Artikel der Ausgabe 8/2010

Archives of Orthopaedic and Trauma Surgery 8/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Traumatologische Notfälle Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.