Skip to main content
Erschienen in: European Radiology 12/2003

01.12.2003 | Chest

Hyperpolarized 3-helium MR imaging of the lungs: testing the concept of a central production facility

verfasst von: E. J. R. van Beek, J. Schmiedeskamp, J. M. Wild, M. N. J. Paley, F. Filbir, S. Fichele, F. Knitz, G. H. Mills, N. Woodhouse, A. Swift, W. Heil, M. Wolf, E. Otten

Erschienen in: European Radiology | Ausgabe 12/2003

Einloggen, um Zugang zu erhalten

Abstract.

The aim of this study was to test the feasibility of a central production facility with distribution network for implementation of hyperpolarized 3-helium MRI. The 3-helium was hyperpolarized to 50–65% using a large-scale production facility based at a university in Germany. Using a specially designed transport box, containing a permanent low-field shielded magnet and dedicated iron-free glass cells, the hyperpolarized 3-helium gas was transported via airfreight to a university in the UK. At this location, the gas was used to perform in vivo MR experiments in normal volunteers and patients with chronic obstructive lung diseases. Following initial tests, the transport (road–air–road cargo) was successfully arranged on six occasions (approximately once per month). The duration of transport to imaging averaged 18 h (range 16–20 h), which was due mainly to organizational issues such as working times and flight connections. During the course of the project, polarization at imaging increased from 20% to more than 30%. A total of 4 healthy volunteers and 8 patients with chronic obstructive pulmonary disease were imaged. The feasibility of a central production facility for hyperpolarized 3-helium was demonstrated. This should enable a wider distribution of gas for this novel technology without the need for local start-up costs.
Literatur
1.
Zurück zum Zitat Murray CJ, Lopez AD (1997) Alternative projections of mortality and disability by cause 1990–2020: global burden of disease study. Lancet 349:1498–1504CrossRefPubMed Murray CJ, Lopez AD (1997) Alternative projections of mortality and disability by cause 1990–2020: global burden of disease study. Lancet 349:1498–1504CrossRefPubMed
2.
Zurück zum Zitat Kauczor HU, Hanke A, van Beek EJR (2002) Assessment of lung ventilation by MR imaging: current status and future perspectives. Eur Radiol 12:1962–1970PubMed Kauczor HU, Hanke A, van Beek EJR (2002) Assessment of lung ventilation by MR imaging: current status and future perspectives. Eur Radiol 12:1962–1970PubMed
3.
Zurück zum Zitat Ebert M, Grossmann T, Heil W et al. (1996) Nuclear magnetic resonance imaging on humans using hyperpolarised 3He. Lancet 347:1297–1299PubMed Ebert M, Grossmann T, Heil W et al. (1996) Nuclear magnetic resonance imaging on humans using hyperpolarised 3He. Lancet 347:1297–1299PubMed
4.
Zurück zum Zitat MacFall JR, Charles HC, Black RD et al. (1996) Human lung air spaces: potential for MR imaging with hyperpolarized He-3. Radiology 200:553–558PubMed MacFall JR, Charles HC, Black RD et al. (1996) Human lung air spaces: potential for MR imaging with hyperpolarized He-3. Radiology 200:553–558PubMed
5.
Zurück zum Zitat Deninger AJ, Eberle B, Ebert M et al. (1999) Quantification of regional intrapulmonary oxygen partial pressure evolution during apnea. J Magn Reson 141:207–216PubMed Deninger AJ, Eberle B, Ebert M et al. (1999) Quantification of regional intrapulmonary oxygen partial pressure evolution during apnea. J Magn Reson 141:207–216PubMed
6.
Zurück zum Zitat Salerno M, Altes TA, Brookeman JR, de Lange EE, Mugler JP III (2001) Dynamic spiral MR imaging of pulmonary gas flow using hyperpolarized 3He: preliminary studies in healthy and diseased lungs. Magn Reson Med 46:667–677PubMed Salerno M, Altes TA, Brookeman JR, de Lange EE, Mugler JP III (2001) Dynamic spiral MR imaging of pulmonary gas flow using hyperpolarized 3He: preliminary studies in healthy and diseased lungs. Magn Reson Med 46:667–677PubMed
7.
Zurück zum Zitat De Lange EE, Mugler JP, Brookeman JR et al. (1999) Lung air spaces: MR imaging evaluation with hyperpolarized 3-He gas. Radiology 210:851–857PubMed De Lange EE, Mugler JP, Brookeman JR et al. (1999) Lung air spaces: MR imaging evaluation with hyperpolarized 3-He gas. Radiology 210:851–857PubMed
8.
Zurück zum Zitat Altes TA, Powers PL, Knight-Scott J et al. (2001) Hyperpolarized 3-He MR lung ventilation imaging in asthmatics: preliminary findings. J Magn Reson Imaging 13:378–384PubMed Altes TA, Powers PL, Knight-Scott J et al. (2001) Hyperpolarized 3-He MR lung ventilation imaging in asthmatics: preliminary findings. J Magn Reson Imaging 13:378–384PubMed
9.
Zurück zum Zitat Miron E, Schaefer S, Schreiber D, van Wijngaarden WA, Zeng X, Happer W (1984) Polarisation of the nuclear spins of noble-gas atoms by spin-exchange with optically-pumped alkali-metal atoms. Phys Rev A29:3092–3110 Miron E, Schaefer S, Schreiber D, van Wijngaarden WA, Zeng X, Happer W (1984) Polarisation of the nuclear spins of noble-gas atoms by spin-exchange with optically-pumped alkali-metal atoms. Phys Rev A29:3092–3110
10.
Zurück zum Zitat Becker J, Heil W, Krug B et al. (1994) Study of mechanical compression of spin-polarized 3-He gas. Nucl Instrum Meth A 346:45–51CrossRef Becker J, Heil W, Krug B et al. (1994) Study of mechanical compression of spin-polarized 3-He gas. Nucl Instrum Meth A 346:45–51CrossRef
11.
Zurück zum Zitat Grossmann T (2000) Vervollständigung des 3-He kreislaufs zur geschwindigkeitselektiven 3-He-magnet-resonance-tomography. Diploma Thesis, University of Mainz Grossmann T (2000) Vervollständigung des 3-He kreislaufs zur geschwindigkeitselektiven 3-He-magnet-resonance-tomography. Diploma Thesis, University of Mainz
12.
Zurück zum Zitat Filbir F (2001) Echtzeit 3-He-kernspin-polarimetrie mittels induktionsstossmessung. Diploma Thesis, University of Mainz Filbir F (2001) Echtzeit 3-He-kernspin-polarimetrie mittels induktionsstossmessung. Diploma Thesis, University of Mainz
13.
Zurück zum Zitat Wild JM, Paley MNJ, Viallon M, Schreiber WG, van Beek EJR, Griffiths PD (2002) k-Space filtering in 2D gradient echo breath-hold hyper-polarised 3-He MRI: spatial resolution and signal to noise considerations. Magn Reson Med 47:687–695CrossRefPubMed Wild JM, Paley MNJ, Viallon M, Schreiber WG, van Beek EJR, Griffiths PD (2002) k-Space filtering in 2D gradient echo breath-hold hyper-polarised 3-He MRI: spatial resolution and signal to noise considerations. Magn Reson Med 47:687–695CrossRefPubMed
14.
Zurück zum Zitat Schreiber WG, Weiler N, Kauczor HU et al. (2000) Ultraschnelle MRT der lungenventilation mittels hochpolarisiertem Helium-3. Rofo Fortschr Geb Roentgenstr Neuen Bildgeb Verfahr 172:129–133CrossRef Schreiber WG, Weiler N, Kauczor HU et al. (2000) Ultraschnelle MRT der lungenventilation mittels hochpolarisiertem Helium-3. Rofo Fortschr Geb Roentgenstr Neuen Bildgeb Verfahr 172:129–133CrossRef
15.
Zurück zum Zitat Wild JM, Paley MNJ, Kasuboski L et al. (2003) Dynamic radial projection MRI of inhaled hyperpolarized 3He. Magn Reson Med 49:991–997CrossRefPubMed Wild JM, Paley MNJ, Kasuboski L et al. (2003) Dynamic radial projection MRI of inhaled hyperpolarized 3He. Magn Reson Med 49:991–997CrossRefPubMed
Metadaten
Titel
Hyperpolarized 3-helium MR imaging of the lungs: testing the concept of a central production facility
verfasst von
E. J. R. van Beek
J. Schmiedeskamp
J. M. Wild
M. N. J. Paley
F. Filbir
S. Fichele
F. Knitz
G. H. Mills
N. Woodhouse
A. Swift
W. Heil
M. Wolf
E. Otten
Publikationsdatum
01.12.2003
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 12/2003
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-003-2094-2

Weitere Artikel der Ausgabe 12/2003

European Radiology 12/2003 Zur Ausgabe

Calendar of events

December 2003

Letter to the Editor

Reply

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.