Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 5/2006

01.07.2006 | Original Article

Inferior stability of a biodegradable cement plug

122 total hip replacements randomized to degradable or non-degradable cement restrictor

verfasst von: Stefan Michael Schauss, Marcus Hinz, Eckard Mayr, Christian Michael Bach, Martin Krismer, Martin Fischer

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 5/2006

Einloggen, um Zugang zu erhalten

Abstract

Introduction: Modern cementing technique demands high intramedullar cement pressure to create an optimum fixed cement support of the femoral stem. Pressure resistant, stable closure of the canal therefore is absolutely necessary. Biodegradable cement restrictors, if corresponding to above mentioned attributes, could be of immense advantage in case of potential revision surgery. Material and methods: A prospective, randomized trial was performed on a consecutive series of 130 patients who underwent primary cemented total hip arthroplasty due to hip arthrosis to compare a degradable cement restrictor and a non-degradable cement restrictor in their ability to resist distal migration during stem insertion. Results: The median cement plug length measured 27 mm (range −12 to 126 mm, 95% confidence interval (CI) 20–33 mm) in the biodegradable restrictor group and 15 mm (range 0–61 mm, 95% CI 12–18 mm) in the non-degradable restrictor group (P=0.003). A significant effect of the relationship between the difference of restrictor size and the diameter of the femoral canal on length of cement distal of the tip of the stem in between the two groups was evident (P=0.031). Conclusion: The results indicate insufficient intramedullary plug fixation of the degradable restrictor probably due to the elastic material properties which also may lead to inferior precision in restrictor size choice.
Literatur
1.
Zurück zum Zitat Askew MJ, Steege JW, Lewis JL, Ranieri JR, Wixson RL (1984) Effect of cement pressure and bone strength on polymethylmethacrylate fixation. J Orthop Res 1(4):412–420CrossRefPubMed Askew MJ, Steege JW, Lewis JL, Ranieri JR, Wixson RL (1984) Effect of cement pressure and bone strength on polymethylmethacrylate fixation. J Orthop Res 1(4):412–420CrossRefPubMed
2.
Zurück zum Zitat Bahr W, Stricker A, Gutwald R, Wellens E (1999) Biodegradable osteosynthesis material for stabilization of midface fractures: experimental investigation in sheep. J Craniomaxillofac Surg 27(1):51–57PubMed Bahr W, Stricker A, Gutwald R, Wellens E (1999) Biodegradable osteosynthesis material for stabilization of midface fractures: experimental investigation in sheep. J Craniomaxillofac Surg 27(1):51–57PubMed
3.
Zurück zum Zitat Barrack RL, Mulroy RD Jr, Harris WH (1992) Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. J Bone Joint Surg Br 74(3):385–389PubMed Barrack RL, Mulroy RD Jr, Harris WH (1992) Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. J Bone Joint Surg Br 74(3):385–389PubMed
4.
Zurück zum Zitat Bostman O, Hirvensalo E, Makinen J, Rokkanen P (1990) Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg Br 72(4):592–596PubMed Bostman O, Hirvensalo E, Makinen J, Rokkanen P (1990) Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg Br 72(4):592–596PubMed
5.
Zurück zum Zitat Bostman OM (1991) Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg Br 73(4):679–682PubMed Bostman OM (1991) Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg Br 73(4):679–682PubMed
6.
Zurück zum Zitat Bulstra SK, Geesink RG, Bakker D, Bulstra TH, Bouwmeester SJ, van der Linden AJ (1996) Femoral canal occlusion in total hip replacement using a resorbable and flexible cement restrictor. J Bone Joint Surg Br 78(6):892–898CrossRefPubMed Bulstra SK, Geesink RG, Bakker D, Bulstra TH, Bouwmeester SJ, van der Linden AJ (1996) Femoral canal occlusion in total hip replacement using a resorbable and flexible cement restrictor. J Bone Joint Surg Br 78(6):892–898CrossRefPubMed
7.
Zurück zum Zitat Claes L, Ignatius A (2002) Development of new, biodegradable implants. Chirurg 73(10):990–996CrossRefPubMed Claes L, Ignatius A (2002) Development of new, biodegradable implants. Chirurg 73(10):990–996CrossRefPubMed
8.
Zurück zum Zitat Freund KG, Herold N, Rock ND, Riegels-Nielsen P (2003) Poor results with the Shuttle Stop: resorbable versus nonresorbable intramedullar cement restrictor in a prospective and randomized study with a 2-year follow-up. Acta Orthop Scand 74(1):37–41CrossRefPubMed Freund KG, Herold N, Rock ND, Riegels-Nielsen P (2003) Poor results with the Shuttle Stop: resorbable versus nonresorbable intramedullar cement restrictor in a prospective and randomized study with a 2-year follow-up. Acta Orthop Scand 74(1):37–41CrossRefPubMed
9.
Zurück zum Zitat Goodman SB, Fornasier VL, Kei J (1988) The effects of bulk versus particulate polymethylmethacrylate on bone. Clin Orthop 232:255–262PubMed Goodman SB, Fornasier VL, Kei J (1988) The effects of bulk versus particulate polymethylmethacrylate on bone. Clin Orthop 232:255–262PubMed
10.
Zurück zum Zitat Hile DD, Doherty SA, Trantolo DJ (2004) Prediction of resorption rates for composite polylactide/hydroxylapatite internal fixation devices based on initial degradation profiles. J Biomed Mater Res 71B(1):201–205CrossRef Hile DD, Doherty SA, Trantolo DJ (2004) Prediction of resorption rates for composite polylactide/hydroxylapatite internal fixation devices based on initial degradation profiles. J Biomed Mater Res 71B(1):201–205CrossRef
11.
Zurück zum Zitat Hungerford DS, Krackow KA (1981) A convenient distal plug for the femoral cavity in total hip arthroplasty. Clin Orthop 154:329–330PubMed Hungerford DS, Krackow KA (1981) A convenient distal plug for the femoral cavity in total hip arthroplasty. Clin Orthop 154:329–330PubMed
12.
Zurück zum Zitat Ignatius AA, Claes LE (1996) In vitro biocompatibility of bioresorbable polymers: poly(l, dl-lactide) and poly(l-lactide-co-glycolide). Biomaterials 17(8):831–839CrossRefPubMed Ignatius AA, Claes LE (1996) In vitro biocompatibility of bioresorbable polymers: poly(l, dl-lactide) and poly(l-lactide-co-glycolide). Biomaterials 17(8):831–839CrossRefPubMed
13.
Zurück zum Zitat Johnson JA, Johnston D el, Hawary R, Tan SR, Wong LA, Gross M (1995) Occlusion and stability of synthetic femoral canal plugs used in cemented hip arthroplasty. J Appl Biomater 6(3):213–218CrossRefPubMed Johnson JA, Johnston D el, Hawary R, Tan SR, Wong LA, Gross M (1995) Occlusion and stability of synthetic femoral canal plugs used in cemented hip arthroplasty. J Appl Biomater 6(3):213–218CrossRefPubMed
14.
Zurück zum Zitat Kristiansen B, Jensen JS (1985) Biomechanical factors in loosening of the Stanmore hip. Acta Orthop Scand 56(1):21–24PubMed Kristiansen B, Jensen JS (1985) Biomechanical factors in loosening of the Stanmore hip. Acta Orthop Scand 56(1):21–24PubMed
15.
Zurück zum Zitat Lindberg HO, Carlsson AS (1983) Mechanical loosening of the femoral component in total hip replacement, Brunswik design. Acta Orthop Scand 54(4):557–561PubMed Lindberg HO, Carlsson AS (1983) Mechanical loosening of the femoral component in total hip replacement, Brunswik design. Acta Orthop Scand 54(4):557–561PubMed
16.
Zurück zum Zitat Malchau H, Herberts P, Ahnfelt L (1993) Prognosis of total hip replacement in Sweden. Follow-up of 92,675 operations performed 1978–1990. Acta Orthop Scand 64(5):497–506PubMedCrossRef Malchau H, Herberts P, Ahnfelt L (1993) Prognosis of total hip replacement in Sweden. Follow-up of 92,675 operations performed 1978–1990. Acta Orthop Scand 64(5):497–506PubMedCrossRef
17.
Zurück zum Zitat Maltry JA, Noble PC, Kamaric E, Tullos HS (1995) Factors influencing pressurization of the femoral canal during cemented total hip arthroplasty. J Arthroplasty 10(4):492–497CrossRefPubMed Maltry JA, Noble PC, Kamaric E, Tullos HS (1995) Factors influencing pressurization of the femoral canal during cemented total hip arthroplasty. J Arthroplasty 10(4):492–497CrossRefPubMed
18.
Zurück zum Zitat Markolf KL, Amstutz HC (1976) In vitro measurement of bone-acrylic interface pressure during femoral component insertion. Clin Orthop 121:60–66PubMed Markolf KL, Amstutz HC (1976) In vitro measurement of bone-acrylic interface pressure during femoral component insertion. Clin Orthop 121:60–66PubMed
19.
Zurück zum Zitat Mjoberg B (1997) The theory of early loosening of hip prostheses. Orthopedics 20(12):1169–1175PubMed Mjoberg B (1997) The theory of early loosening of hip prostheses. Orthopedics 20(12):1169–1175PubMed
20.
Zurück zum Zitat Murray DW, Rushton N (1990) Macrophages stimulate bone resorption when they phagocytose particles. J Bone Joint Surg Br 72(6):988–992PubMed Murray DW, Rushton N (1990) Macrophages stimulate bone resorption when they phagocytose particles. J Bone Joint Surg Br 72(6):988–992PubMed
21.
Zurück zum Zitat Noble PC, Alexander JW, Lindahl LJ, Yew DT, Granberry WM, Tullos HS (1988) The anatomic basis of femoral component design. Clin Orthop 235:148–165PubMed Noble PC, Alexander JW, Lindahl LJ, Yew DT, Granberry WM, Tullos HS (1988) The anatomic basis of femoral component design. Clin Orthop 235:148–165PubMed
22.
Zurück zum Zitat Northmore-Ball MD, Narang OV, Vergroesen D (1991) Distal femoral plug migration with cement pressurization in revision surgery and a simple technique for its prevention. J Arthroplasty 6(3):199–201PubMedCrossRef Northmore-Ball MD, Narang OV, Vergroesen D (1991) Distal femoral plug migration with cement pressurization in revision surgery and a simple technique for its prevention. J Arthroplasty 6(3):199–201PubMedCrossRef
23.
Zurück zum Zitat Oh I, Carlson CE, Tomford WW, Harris WH (1978) Improved fixation of the femoral component after total hip replacement using a methacrylate intramedullary plug. J Bone Joint Surg Am 60(5):608–613PubMed Oh I, Carlson CE, Tomford WW, Harris WH (1978) Improved fixation of the femoral component after total hip replacement using a methacrylate intramedullary plug. J Bone Joint Surg Am 60(5):608–613PubMed
24.
Zurück zum Zitat Rokkanen PU, Bostman O, Hirvensalo E, Makela EA, Partio EK, Patiala H, Vainionpaa SI, Vihtonen K, Tormala P (2000) Bioabsorbable fixation in orthopaedic surgery and traumatology. Biomaterials 21(24):2607–2613CrossRefPubMed Rokkanen PU, Bostman O, Hirvensalo E, Makela EA, Partio EK, Patiala H, Vainionpaa SI, Vihtonen K, Tormala P (2000) Bioabsorbable fixation in orthopaedic surgery and traumatology. Biomaterials 21(24):2607–2613CrossRefPubMed
25.
Zurück zum Zitat Williams DF (1992) Mechanisms of biodegradation of implantable polymers. Clin Mater 10(1–2):9–12CrossRefPubMed Williams DF (1992) Mechanisms of biodegradation of implantable polymers. Clin Mater 10(1–2):9–12CrossRefPubMed
26.
Zurück zum Zitat Wroblewski BM, van der Rijt A (1984) Intramedullary cancellous bone block to improve femoral stem fixation in Charnley low-friction arthroplasty. J Bone Joint Surg Br 66(5):639–644PubMed Wroblewski BM, van der Rijt A (1984) Intramedullary cancellous bone block to improve femoral stem fixation in Charnley low-friction arthroplasty. J Bone Joint Surg Br 66(5):639–644PubMed
27.
Zurück zum Zitat Yee RD, Newton CW, Patterson SS, Swartz ML (1984) The effect of canal preparation on the formation and leakage characteristics of the apical dentin plug. J Endod 10(7):308–317PubMedCrossRef Yee RD, Newton CW, Patterson SS, Swartz ML (1984) The effect of canal preparation on the formation and leakage characteristics of the apical dentin plug. J Endod 10(7):308–317PubMedCrossRef
Metadaten
Titel
Inferior stability of a biodegradable cement plug
122 total hip replacements randomized to degradable or non-degradable cement restrictor
verfasst von
Stefan Michael Schauss
Marcus Hinz
Eckard Mayr
Christian Michael Bach
Martin Krismer
Martin Fischer
Publikationsdatum
01.07.2006
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 5/2006
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-006-0132-7

Weitere Artikel der Ausgabe 5/2006

Archives of Orthopaedic and Trauma Surgery 5/2006 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Knie-TEP: Kein Vorteil durch antibiotikahaltigen Knochenzement

29.05.2024 Periprothetische Infektionen Nachrichten

Zur Zementierung einer Knie-TEP wird in Deutschland zu über 98% Knochenzement verwendet, der mit einem Antibiotikum beladen ist. Ob er wirklich besser ist als Zement ohne Antibiotikum, kann laut Registerdaten bezweifelt werden.

Häusliche Gewalt in der orthopädischen Notaufnahme oft nicht erkannt

28.05.2024 Häusliche Gewalt Nachrichten

In der Notaufnahme wird die Chance, Opfer von häuslicher Gewalt zu identifizieren, von Orthopäden und Orthopädinnen offenbar zu wenig genutzt. Darauf deuten die Ergebnisse einer Fragebogenstudie an der Sahlgrenska-Universität in Schweden hin.

Fehlerkultur in der Medizin – Offenheit zählt!

28.05.2024 Fehlerkultur Podcast

Darüber reden und aus Fehlern lernen, sollte das Motto in der Medizin lauten. Und zwar nicht nur im Sinne der Patientensicherheit. Eine negative Fehlerkultur kann auch die Behandelnden ernsthaft krank machen, warnt Prof. Dr. Reinhard Strametz. Ein Plädoyer und ein Leitfaden für den offenen Umgang mit kritischen Ereignissen in Medizin und Pflege.

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.