Abstract

Objective

The aim of this paper is to demonstrate the usefulness of 2D multiplanar reformatting images (MPR) obtained from rotational acquisitions with cone-beam computed tomography technology during percutaneous extra-vascular spinal procedures performed in the angiography suite.

Methods

We used a 3D rotational angiographic unit with a flat panel detector. MPR images were obtained from a rotational acquisition of 8 s (240 images at 30 fps), tube rotation of 180° and after post-processing of 5 s by a local work-station. Multislice CT (MSCT) is the best guidance system for spinal approaches permitting direct tomographic visualization of each spinal structure. Many operators, however, are trained with fluoroscopy, it is less expensive, allows real-time guidance, and in many centers the angiography suite is more frequently available for percutaneous procedures. We present our 6-year experience in fluoroscopy-guided spinal procedures, which were performed under different conditions using MPR images. We illustrate cases of vertebroplasty, epidural injections, selective foraminal nerve root block, facet block, percutaneous treatment of disc herniation and spine biopsy, all performed with the help of MPR images for guidance and control in the event of difficult or anatomically complex access.

Results and conclusion

The integrated use of “CT-like” MPR images allows the execution of spinal procedures under fluoroscopy guidance alone in all cases of dorso-lumbar access, with evident limitation of risks and complications, and without need for recourse to MSCT guidance, thus eliminating CT-room time (often bearing high diagnostic charges), and avoiding organizational problems for procedures that need, for example, combined use of a C-arm in the CT room.
Literatur
1.
Zurück zum Zitat Orth RC, Wallace MJ, Kuo MD. C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology. J Vasc Interv Radiol. 2008;19(6):814–20.CrossRef Orth RC, Wallace MJ, Kuo MD. C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology. J Vasc Interv Radiol. 2008;19(6):814–20.CrossRef
2.
Zurück zum Zitat Gupta R, Grasruck M, Suess C, et al. Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization. Eur Radiol. 2006;16(6):1191–205.CrossRef Gupta R, Grasruck M, Suess C, et al. Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization. Eur Radiol. 2006;16(6):1191–205.CrossRef
3.
Zurück zum Zitat Powell MF, DiNobile D, Reddy AS. C-arm fluoroscopic cone beam CT for guidance of minimally invasive spine interventions. Pain Physician. 2010;13(1):51–9. Powell MF, DiNobile D, Reddy AS. C-arm fluoroscopic cone beam CT for guidance of minimally invasive spine interventions. Pain Physician. 2010;13(1):51–9.
4.
Zurück zum Zitat Fenton DS, Czervionke LF. Image-guided spine intervention. Philadelphia: Saunders (Elsevier); 2003. p. 23. Fenton DS, Czervionke LF. Image-guided spine intervention. Philadelphia: Saunders (Elsevier); 2003. p. 23.
5.
Zurück zum Zitat Wallace MJ, Kuo MD, Glaiberman C. Three-dimensional C-arm cone-beam CT: applications in the interventional suite. J Vasc Interv Radiol. 2008;19:799–813.CrossRef Wallace MJ, Kuo MD, Glaiberman C. Three-dimensional C-arm cone-beam CT: applications in the interventional suite. J Vasc Interv Radiol. 2008;19:799–813.CrossRef
6.
Zurück zum Zitat Hodek-Wuerz R, Martin JB, Wilhelm K, et al. Percutaneous vertebroplasty: preliminary experiences with rotational acquisitions and 3D reconstructions for therapy control. Cardiovasc Interv Radiol. 2006;29:862–5.CrossRef Hodek-Wuerz R, Martin JB, Wilhelm K, et al. Percutaneous vertebroplasty: preliminary experiences with rotational acquisitions and 3D reconstructions for therapy control. Cardiovasc Interv Radiol. 2006;29:862–5.CrossRef
7.
Zurück zum Zitat Pedicelli A, Rollo M, Piano M, et al. Percutaneous vertebroplasty with a high-quality rotational angiographic unit. Eur J Radiol. 2009;69(2):289–95.CrossRef Pedicelli A, Rollo M, Piano M, et al. Percutaneous vertebroplasty with a high-quality rotational angiographic unit. Eur J Radiol. 2009;69(2):289–95.CrossRef
8.
Zurück zum Zitat Gangi A, Kastler BA, Dietemann JL. Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy. Am J Neuroradiol. 1994;15:83–6. Gangi A, Kastler BA, Dietemann JL. Percutaneous vertebroplasty guided by a combination of CT and fluoroscopy. Am J Neuroradiol. 1994;15:83–6.
9.
Zurück zum Zitat Carlson SK, Bender CE, Classic KL, et al. Benefits and safety of CT fluoroscopy in interventional radiologic procedures. Radiology. 2001;219:515–20.CrossRef Carlson SK, Bender CE, Classic KL, et al. Benefits and safety of CT fluoroscopy in interventional radiologic procedures. Radiology. 2001;219:515–20.CrossRef
10.
Zurück zum Zitat Braak SJ, van Strijen MJ, van Leersum M, et al. Real-time 3D fluoroscopy guidance during needle interventions: technique, accuracy, and feasibility. AJR Am J Roentgenol. 2010;194(5):W445–51.CrossRef Braak SJ, van Strijen MJ, van Leersum M, et al. Real-time 3D fluoroscopy guidance during needle interventions: technique, accuracy, and feasibility. AJR Am J Roentgenol. 2010;194(5):W445–51.CrossRef
11.
Zurück zum Zitat Busser WM, Hoogeveen YL, Veth RP, et al. Percutaneous radiofrequency ablation of osteoid osteomas with use of real-time needle guidance for accurate needle placement: a pilot study. Cardiovasc Interv Radiol. 2011;34(1):180–3.CrossRef Busser WM, Hoogeveen YL, Veth RP, et al. Percutaneous radiofrequency ablation of osteoid osteomas with use of real-time needle guidance for accurate needle placement: a pilot study. Cardiovasc Interv Radiol. 2011;34(1):180–3.CrossRef
12.
Zurück zum Zitat Kim JH, Park KS, Yi S, et al. Real-time CT fluoroscopy (CTF)-guided vertebroplasty in osteoporotic spine fractures. Yonsei Med J. 2005;46(5):635–42.CrossRef Kim JH, Park KS, Yi S, et al. Real-time CT fluoroscopy (CTF)-guided vertebroplasty in osteoporotic spine fractures. Yonsei Med J. 2005;46(5):635–42.CrossRef
13.
Zurück zum Zitat Gangi A, Guth S, Imbert JP, et al. Percutaneous vertebroplasty: indications, technique, and results. Radiographics. 2003;23:e10.CrossRef Gangi A, Guth S, Imbert JP, et al. Percutaneous vertebroplasty: indications, technique, and results. Radiographics. 2003;23:e10.CrossRef
14.
Zurück zum Zitat Daly B, Templeton PA. Real-time CT fluoroscopy: evolution of an interventional tool. Radiology. 1999;211:309–15.CrossRef Daly B, Templeton PA. Real-time CT fluoroscopy: evolution of an interventional tool. Radiology. 1999;211:309–15.CrossRef
15.
Zurück zum Zitat Hott JS, Papadopoulos SM, Theodore N, et al. Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases. Spine (Phila Pa 1976). 2004;29(24):2856–60.CrossRef Hott JS, Papadopoulos SM, Theodore N, et al. Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases. Spine (Phila Pa 1976). 2004;29(24):2856–60.CrossRef
16.
Zurück zum Zitat Tam A, Mohamed A, Pfister M, et al. C-arm cone beam computed tomographic needle path overlay for fluoroscopic-guided placement of translumbar central venous catheters. Cardiovasc Interv Radiol. 2009;32(4):820–4.CrossRef Tam A, Mohamed A, Pfister M, et al. C-arm cone beam computed tomographic needle path overlay for fluoroscopic-guided placement of translumbar central venous catheters. Cardiovasc Interv Radiol. 2009;32(4):820–4.CrossRef
17.
Zurück zum Zitat Tam A, Mohamed A, Pfister M, et al. C-arm cone beam computed tomography needle. Path overlay for fluoroscopic guided vertebroplasty. Spine. 2010;35(10):1095–9.CrossRef Tam A, Mohamed A, Pfister M, et al. C-arm cone beam computed tomography needle. Path overlay for fluoroscopic guided vertebroplasty. Spine. 2010;35(10):1095–9.CrossRef
18.
Zurück zum Zitat Söderman M, Babic D, Holmin S, et al. Brain imaging with a flat detector C-arm: technique and clinical interest of XperCT. Neuroradiology. 2008;50(10):863–8.CrossRef Söderman M, Babic D, Holmin S, et al. Brain imaging with a flat detector C-arm: technique and clinical interest of XperCT. Neuroradiology. 2008;50(10):863–8.CrossRef
19.
Zurück zum Zitat Knight JR, Heran M, Munk PL, et al. C-arm cone-beam CT: applications for spinal cement augmentation demonstrated by three cases. J Vasc Interv Radiol. 2008;19(7):1118–22.CrossRef Knight JR, Heran M, Munk PL, et al. C-arm cone-beam CT: applications for spinal cement augmentation demonstrated by three cases. J Vasc Interv Radiol. 2008;19(7):1118–22.CrossRef
Metadaten
Titel
Interventional spinal procedures guided and controlled by a 3D rotational angiographic unit
verfasst von
Alessandro Pedicelli
Tommaso Verdolotti
Angelo Pompucci
Flora Desiderio
Francesco D’Argento
Cesare Colosimo
Lorenzo Bonomo
Publikationsdatum
01.12.2011
Verlag
Springer Berlin Heidelberg
Erschienen in
Skeletal Radiology / Ausgabe 12/2011
Print ISSN: 0364-2348
Elektronische ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-011-1282-4

Weitere Artikel der Ausgabe 12/2011

Skeletal Radiology 12/2011 Zur Ausgabe

Test Yourself: Question

Teenager with multiple fractures

Darf man die Behandlung eines Neonazis ablehnen?

08.05.2024 Gesellschaft Nachrichten

In einer Leseranfrage in der Zeitschrift Journal of the American Academy of Dermatology möchte ein anonymer Dermatologe bzw. eine anonyme Dermatologin wissen, ob er oder sie einen Patienten behandeln muss, der eine rassistische Tätowierung trägt.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.