Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 9/2009

01.09.2009 | Osteoporotic Fracture Management

Bone quality measured by the radiogrammetric parameter “cortical index” and reoperations after locking plate osteosynthesis in patients sustaining proximal humerus fractures

verfasst von: Pierre Hepp, Jan Theopold, Georg Osterhoff, Bastian Marquass, Christine Voigt, Christoph Josten

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 9/2009

Einloggen, um Zugang zu erhalten

Abstract

Aim

To analyse the radiogrammetric parameter “cortical index” (CI) and its predictive value for proximal humerus fractures. Furthermore, to investigate the reoperations and the cause of reoperations after locking plate osteosynthesis of displaced proximal humerus fractures.

Patients and methods

113 consecutive patients (73 women and 40 men) with a median age of 66 years (range 18–100 years) were included in this study. The median follow-up time in our database was 4.7 years (range 45–72 months). For a comparative matched-group analysis of the CI, patients with a fall on the shoulder without fracture were selected. Demographic data and all reoperations were recorded after median 58 months postoperatively. The CI was measured at the proximal humeral diaphysis.

Results

The CI showed to be significant lower in the fracture group (mean 0.28) when compared to the matched group (mean 0.47, p < 0.01). 39% patients underwent a reoperation within 40 months postoperatively. 24% were reoperated within the first 12 months postoperatively, and 15% were reoperated after 12 months or later. The reoperation was independent of bone quality (p = 0.85).

Conclusions

The risk for reoperation is independent of the CI even though the CI may be a predictor for proximal humerus fracture. Younger patients should be aware that surgical treatment of proximal humerus fractures might be a two-stage surgery. Regular follow-up visits for older patients during the first postoperative year must be assured.
Literatur
1.
Zurück zum Zitat Athwal GS, Sperling JW, Rispoli DM, Cofield RH (2007) Acute deep infection after surgical fixation of proximal humeral fractures. J Shoulder Elbow Surg 16(4):408–412PubMedCrossRef Athwal GS, Sperling JW, Rispoli DM, Cofield RH (2007) Acute deep infection after surgical fixation of proximal humeral fractures. J Shoulder Elbow Surg 16(4):408–412PubMedCrossRef
2.
Zurück zum Zitat Bach-Mortensen P, Hyldstrup L, Appleyard M, Hindso K, Gebuhr P, Sonne-Holm S (2006) Digital X-ray radiogrammetry identifies women at risk of osteoporotic fracture: results from a prospective study. Calcif Tissue Int 79(1):1–6PubMedCrossRef Bach-Mortensen P, Hyldstrup L, Appleyard M, Hindso K, Gebuhr P, Sonne-Holm S (2006) Digital X-ray radiogrammetry identifies women at risk of osteoporotic fracture: results from a prospective study. Calcif Tissue Int 79(1):1–6PubMedCrossRef
3.
Zurück zum Zitat Björkenheim JM, Pajarinen J, Savolainen V (2004) Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year. Acta Orthop Scand 75(6):741–745PubMedCrossRef Björkenheim JM, Pajarinen J, Savolainen V (2004) Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year. Acta Orthop Scand 75(6):741–745PubMedCrossRef
4.
Zurück zum Zitat Bloom RA, Laws JW (1970) Humeral cortical thickness as an index of osteoporosis in women. Br J Radiol 43(512):522–527PubMedCrossRef Bloom RA, Laws JW (1970) Humeral cortical thickness as an index of osteoporosis in women. Br J Radiol 43(512):522–527PubMedCrossRef
5.
Zurück zum Zitat Charalambous CP, Siddique I, Valluripalli K, Kovacevic M, Panose P, Srinivasan M, Marynissen H (2007) Proximal humeral internal locking system (PHILOS) for the treatment of proximal humeral fractures. Arch Orthop Trauma Surg 127(3):205–210PubMedCrossRef Charalambous CP, Siddique I, Valluripalli K, Kovacevic M, Panose P, Srinivasan M, Marynissen H (2007) Proximal humeral internal locking system (PHILOS) for the treatment of proximal humeral fractures. Arch Orthop Trauma Surg 127(3):205–210PubMedCrossRef
6.
Zurück zum Zitat Court-Brown CM, Garg A, McQueen MM (2001) The epidemiology of proximal humeral fractures. Acta Orthop Scand 72(4):365–371PubMedCrossRef Court-Brown CM, Garg A, McQueen MM (2001) The epidemiology of proximal humeral fractures. Acta Orthop Scand 72(4):365–371PubMedCrossRef
7.
Zurück zum Zitat Diederichs G, Korner J, Goldhahn J, Linke B (2006) Assessment of bone quality in the proximal humerus by measurement of the contralateral site: a cadaveric analyze. Arch Orthop Trauma Surg 126(2):93–100PubMedCrossRef Diederichs G, Korner J, Goldhahn J, Linke B (2006) Assessment of bone quality in the proximal humerus by measurement of the contralateral site: a cadaveric analyze. Arch Orthop Trauma Surg 126(2):93–100PubMedCrossRef
8.
Zurück zum Zitat Fankhauser F, Boldin C, Schippinger G, Haunschmid C, Szyszkowitz R (2005) A new locking plate for unstable fractures of the proximal humerus. Clin Orthop Relat Res 430:176–181PubMedCrossRef Fankhauser F, Boldin C, Schippinger G, Haunschmid C, Szyszkowitz R (2005) A new locking plate for unstable fractures of the proximal humerus. Clin Orthop Relat Res 430:176–181PubMedCrossRef
9.
Zurück zum Zitat Hente R, Kampshoff J, Kinner B, Fuchtmeier B, Nerlich M (2004) Treatment of dislocated 3- and 4-part fractures of the proximal humerus with an angle-stabilizing fixation plate. Unfallchirurg 107(9):769–782PubMedCrossRef Hente R, Kampshoff J, Kinner B, Fuchtmeier B, Nerlich M (2004) Treatment of dislocated 3- and 4-part fractures of the proximal humerus with an angle-stabilizing fixation plate. Unfallchirurg 107(9):769–782PubMedCrossRef
10.
Zurück zum Zitat Hepp P, Lill H, Bail H, Korner J, Niederhagen M, Haas NP, Josten C, Duda GN (2003) Where should implants be anchored in the humeral head? Clin Orthop Relat Res 415:139–147PubMedCrossRef Hepp P, Lill H, Bail H, Korner J, Niederhagen M, Haas NP, Josten C, Duda GN (2003) Where should implants be anchored in the humeral head? Clin Orthop Relat Res 415:139–147PubMedCrossRef
11.
Zurück zum Zitat Hepp P, Theopold J, Voigt C, Engel T, Josten C, Lill H (2008) The surgical approach for locking plate osteosynthesis of displaced proximal humeral fractures influences the functional outcome. J Shoulder Elbow Surg 17(1):21–28PubMedCrossRef Hepp P, Theopold J, Voigt C, Engel T, Josten C, Lill H (2008) The surgical approach for locking plate osteosynthesis of displaced proximal humeral fractures influences the functional outcome. J Shoulder Elbow Surg 17(1):21–28PubMedCrossRef
12.
Zurück zum Zitat Jergas M, Schmid G (1999) Konventionelle Radiologie der Osteoporose und Röntgenabsorptiometrie. Radiologe 39(3):174–185PubMedCrossRef Jergas M, Schmid G (1999) Konventionelle Radiologie der Osteoporose und Röntgenabsorptiometrie. Radiologe 39(3):174–185PubMedCrossRef
13.
Zurück zum Zitat Kannus P, Palvanen M, Niemi S, Parkkari J, Jarvinen M, Vuori I (2000) Osteoporotic fractures of the proximal humerus in elderly Finnish persons: sharp increase in 1970–1998 and alarming projections for the new millennium. Acta Orthop Scand 71(5):465–470PubMedCrossRef Kannus P, Palvanen M, Niemi S, Parkkari J, Jarvinen M, Vuori I (2000) Osteoporotic fractures of the proximal humerus in elderly Finnish persons: sharp increase in 1970–1998 and alarming projections for the new millennium. Acta Orthop Scand 71(5):465–470PubMedCrossRef
14.
Zurück zum Zitat Koukakis A, Apostolou CD, Taneja T, Korres DS, Amini A (2006) Fixation of proximal humerus fractures using the PHILOS plate: early experience. Clin Orthop Relat Res 442:115–120PubMedCrossRef Koukakis A, Apostolou CD, Taneja T, Korres DS, Amini A (2006) Fixation of proximal humerus fractures using the PHILOS plate: early experience. Clin Orthop Relat Res 442:115–120PubMedCrossRef
15.
Zurück zum Zitat Lill H, Hepp P, Gowin W, Oestmann JW, Korner J, Haas NP, Josten C, Duda GN (2002) Age- and gender-related distribution of bone mineral density and mechanical properties of the proximal humerus. Röfo 174(12):1544–1550PubMed Lill H, Hepp P, Gowin W, Oestmann JW, Korner J, Haas NP, Josten C, Duda GN (2002) Age- and gender-related distribution of bone mineral density and mechanical properties of the proximal humerus. Röfo 174(12):1544–1550PubMed
16.
Zurück zum Zitat Monoot P, Ashwood N, Hamlet M (2007) Early results for treatment of three- and four-part fractures of the proximal humerus using the PHILOS plate system. J Bone Joint Surg Br 89:1206–1209CrossRef Monoot P, Ashwood N, Hamlet M (2007) Early results for treatment of three- and four-part fractures of the proximal humerus using the PHILOS plate system. J Bone Joint Surg Br 89:1206–1209CrossRef
17.
Zurück zum Zitat Neer CS 2nd (2002) Four-segment classification of proximal humeral fractures: purpose and reliable use. J Shoulder Elbow Surg 11(4):389–400PubMedCrossRef Neer CS 2nd (2002) Four-segment classification of proximal humeral fractures: purpose and reliable use. J Shoulder Elbow Surg 11(4):389–400PubMedCrossRef
18.
Zurück zum Zitat Noh SJ, Brophy RH, Barker JU, Cornell CN, MacGillivray JD (2007) Management of proximal humeral fractures based on current literature. J Bone Joint Surg Am 89(Suppl 3):44–58 Noh SJ, Brophy RH, Barker JU, Cornell CN, MacGillivray JD (2007) Management of proximal humeral fractures based on current literature. J Bone Joint Surg Am 89(Suppl 3):44–58
19.
Zurück zum Zitat Plecko M, Kraus A (2005) Internal fixation of proximal humerus fractures using the locking proximal humerus plate. Oper Orthop Traumatol 17(1):25–50PubMedCrossRef Plecko M, Kraus A (2005) Internal fixation of proximal humerus fractures using the locking proximal humerus plate. Oper Orthop Traumatol 17(1):25–50PubMedCrossRef
20.
Zurück zum Zitat Smith AM, Mardones RM, Sperling JW, Cofield RH (2007) Early complications of operatively treated proximal humeral fractures. J Shoulder Elbow Surg 16(1):14–24PubMedCrossRef Smith AM, Mardones RM, Sperling JW, Cofield RH (2007) Early complications of operatively treated proximal humeral fractures. J Shoulder Elbow Surg 16(1):14–24PubMedCrossRef
21.
Zurück zum Zitat Strohm PC, Köstler W, Südkamp NP (2005) Locking plate fixation of proximal humerus fractures. Techn Shoulder Elbow Surg 6(1):8–13 Strohm PC, Köstler W, Südkamp NP (2005) Locking plate fixation of proximal humerus fractures. Techn Shoulder Elbow Surg 6(1):8–13
22.
Zurück zum Zitat Tingart MJ, Apreleva M, von Stechow D, Zurakowski D, Warner JJ (2003) The cortical thickness of the proximal humeral diaphysis predicts bone mineral density of the proximal humerus. J Bone Joint Surg Br 85(4):611–617PubMedCrossRef Tingart MJ, Apreleva M, von Stechow D, Zurakowski D, Warner JJ (2003) The cortical thickness of the proximal humeral diaphysis predicts bone mineral density of the proximal humerus. J Bone Joint Surg Br 85(4):611–617PubMedCrossRef
23.
Zurück zum Zitat Tingart MJ, Bouxsein ML, Zurakowski D, Warner JP, Apreleva M (2003) Three-dimensional distribution of bone density in the proximal humerus. Calcif Tissue Int 73(6):531–536PubMed Tingart MJ, Bouxsein ML, Zurakowski D, Warner JP, Apreleva M (2003) Three-dimensional distribution of bone density in the proximal humerus. Calcif Tissue Int 73(6):531–536PubMed
24.
Zurück zum Zitat Voigt C, Woltmann A, Partenheimer A, Lill H (2007) Management of complications after angularly stable locking proximal humerus plate fixation. Chirurg 78(1):40–46PubMedCrossRef Voigt C, Woltmann A, Partenheimer A, Lill H (2007) Management of complications after angularly stable locking proximal humerus plate fixation. Chirurg 78(1):40–46PubMedCrossRef
25.
Zurück zum Zitat Yamada M, Briot J, Pedrono A, Sans N, Mansat P, Mansat M, Swider P (2007) Age- and gender-related distribution of bone tissue of osteoporotic humeral head using computed tomography. J Shoulder Elbow Surg 16(5):596–602PubMedCrossRef Yamada M, Briot J, Pedrono A, Sans N, Mansat P, Mansat M, Swider P (2007) Age- and gender-related distribution of bone tissue of osteoporotic humeral head using computed tomography. J Shoulder Elbow Surg 16(5):596–602PubMedCrossRef
Metadaten
Titel
Bone quality measured by the radiogrammetric parameter “cortical index” and reoperations after locking plate osteosynthesis in patients sustaining proximal humerus fractures
verfasst von
Pierre Hepp
Jan Theopold
Georg Osterhoff
Bastian Marquass
Christine Voigt
Christoph Josten
Publikationsdatum
01.09.2009
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 9/2009
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-009-0889-6

Weitere Artikel der Ausgabe 9/2009

Archives of Orthopaedic and Trauma Surgery 9/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.