Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 7/2012

01.10.2012 | Original paper

Evaluation of in-stent neointimal tissue components using integrated backscatter intravascular ultrasound: comparison of drug-eluting stents and bare-metal stents

verfasst von: Yoshitaka Muraoka, Shinjo Sonoda, Kuninobu Kashiyama, Fumihiko Kamezaki, Yuki Tsuda, Masaru Araki, Masahiro Okazaki, Yutaka Otsuji

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 7/2012

Einloggen, um Zugang zu erhalten

Abstract

Although in-stent restenosis (ISR) occurs after drug-eluting stents (DES) implantation, neointimal tissue characteristics have not been fully investigated. We assessed neointimal tissue components using integrated backscatter intravascular ultrasound (IB-IVUS) after DES and bare-metal stents (BMS) implantation. Fifty-seven consecutive patients with 61 lesions underwent repeated percutaneous coronary intervention (PCI) for the treatment of ISR (DES: 24 lesions, BMS: 37 lesions). PCI was performed using plain old balloon angioplasty (POBA). Before PCI, we assessed neointimal tissue characteristics using IB-IVUS. Neointima was divided into four categories: category 1 (−11 to −29 dB), category 2 (−29 to −35 dB), category 3 (−35 to −49 dB), and category 4 (−49 to −130 dB) according to IB values. We compared neointimal tissue components between DES and BMS. Thirty-three patients with 33 lesions (DES: 17, BMS: 16) were finally included. Neointima was predominantly composed of category 3 tissue in both groups (DES: 68 ± 8%, BMS: 73 ± 5%, P = 0.053). DES had a broader distribution of category 4 tissue component than BMS. After POBA, distal slow flow phenomenon occurred in 5 of DES (29%), whereas none of BMS. In DES, the optimal threshold of category 4 tissue to predict distal slow flow phenomenon after POBA was 30% (sensitivity: 100%, specificity: 92%). Neointima was mainly composed of category 3 tissue at ISR site, irrespective of DES or BMS. In DES, there was a subgroup with category 4 rich tissue, which caused distal slow flow phenomenon after POBA. IB-IVUS might be useful to identify vulnerable neointima in DES restenosis.
Literatur
1.
Zurück zum Zitat Hoffmann R, Mintz GS, Dussaillant GR, Popma JJ, Pichard AD, Satler LF et al (1996) Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study. Circulation 94(6):1247–1254PubMedCrossRef Hoffmann R, Mintz GS, Dussaillant GR, Popma JJ, Pichard AD, Satler LF et al (1996) Patterns and mechanisms of in-stent restenosis. A serial intravascular ultrasound study. Circulation 94(6):1247–1254PubMedCrossRef
2.
Zurück zum Zitat Mehran R, Mintz GS, Hong MK, Tio FO, Bramwell O, Brahimi A et al (1998) Validation of the in vivo intravascular ultrasound measurement of in-stent neointimal hyperplasia volumes. J Am Coll Cardiol 32(3):794–799PubMedCrossRef Mehran R, Mintz GS, Hong MK, Tio FO, Bramwell O, Brahimi A et al (1998) Validation of the in vivo intravascular ultrasound measurement of in-stent neointimal hyperplasia volumes. J Am Coll Cardiol 32(3):794–799PubMedCrossRef
3.
Zurück zum Zitat Grewe PH, Deneke T, Machraoui A, Barmeyer J, Muller KM (2000) Acute and chronic tissue response to coronary stent implantation: pathologic findings in human specimen. J Am Coll Cardiol 35(1):157–163PubMedCrossRef Grewe PH, Deneke T, Machraoui A, Barmeyer J, Muller KM (2000) Acute and chronic tissue response to coronary stent implantation: pathologic findings in human specimen. J Am Coll Cardiol 35(1):157–163PubMedCrossRef
4.
Zurück zum Zitat Murata T, Hiro T, Fujii T, Yasumoto K, Murashige A, Kohno M et al (2002) Impact of the cross-sectional geometry of the post-deployment coronary stent on in-stent neointimal hyperplasia: an intravascular ultrasound study. Circ J 66(5):489–493PubMedCrossRef Murata T, Hiro T, Fujii T, Yasumoto K, Murashige A, Kohno M et al (2002) Impact of the cross-sectional geometry of the post-deployment coronary stent on in-stent neointimal hyperplasia: an intravascular ultrasound study. Circ J 66(5):489–493PubMedCrossRef
5.
Zurück zum Zitat Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M et al (2002) A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 346(23):1773–1780PubMedCrossRef Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M et al (2002) A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 346(23):1773–1780PubMedCrossRef
6.
Zurück zum Zitat Stone GW, Ellis SG, Cox DA, Hermiller J, O’Shaughnessy C, Mann JT et al (2004) A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 350(3):221–231PubMedCrossRef Stone GW, Ellis SG, Cox DA, Hermiller J, O’Shaughnessy C, Mann JT et al (2004) A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 350(3):221–231PubMedCrossRef
7.
Zurück zum Zitat Lee SH, Park JS, Shin DG, Kim YJ, Hong GR, Kim W et al (2007) Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation. Am J Cardiol 100(4):627–630PubMedCrossRef Lee SH, Park JS, Shin DG, Kim YJ, Hong GR, Kim W et al (2007) Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation. Am J Cardiol 100(4):627–630PubMedCrossRef
8.
Zurück zum Zitat Kuriyama N, Kobayashi Y, Nakayama T, Kuroda N, Komuro I (2006) Images in cardiovascular medicine. Damage to polymer of a sirolimus-eluting stent. Circulation 114(20):e586–e587PubMedCrossRef Kuriyama N, Kobayashi Y, Nakayama T, Kuroda N, Komuro I (2006) Images in cardiovascular medicine. Damage to polymer of a sirolimus-eluting stent. Circulation 114(20):e586–e587PubMedCrossRef
9.
Zurück zum Zitat Virmani R, Guagliumi G, Farb A, Musumeci G, Grieco N, Motta T et al (2004) Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 109(6):701–705PubMedCrossRef Virmani R, Guagliumi G, Farb A, Musumeci G, Grieco N, Motta T et al (2004) Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 109(6):701–705PubMedCrossRef
10.
Zurück zum Zitat Virmani R, Liistro F, Stankovic G, Di Mario C, Montorfano M, Farb A et al (2002) Mechanism of late in-stent restenosis after implantation of a paclitaxel derivate-eluting polymer stent system in humans. Circulation 106(21):2649–2651PubMedCrossRef Virmani R, Liistro F, Stankovic G, Di Mario C, Montorfano M, Farb A et al (2002) Mechanism of late in-stent restenosis after implantation of a paclitaxel derivate-eluting polymer stent system in humans. Circulation 106(21):2649–2651PubMedCrossRef
11.
Zurück zum Zitat Kwon SW, Kim BK, Kim TH, Kim JS, Ko YG, Choi D et al (2011) Qualitative assessment of neointimal tissue after drug-eluting stent implantation: comparison between follow-up optical coherence tomography and intravascular ultrasound. Am Heart J 161(2):367–372PubMedCrossRef Kwon SW, Kim BK, Kim TH, Kim JS, Ko YG, Choi D et al (2011) Qualitative assessment of neointimal tissue after drug-eluting stent implantation: comparison between follow-up optical coherence tomography and intravascular ultrasound. Am Heart J 161(2):367–372PubMedCrossRef
12.
Zurück zum Zitat Okubo M, Kawasaki M, Ishihara Y, Takeyama U, Kubota T, Yamaki T et al (2008) Development of integrated backscatter intravascular ultrasound for tissue characterization of coronary plaques. Ultrasound Med Biol 34(4):655–663PubMedCrossRef Okubo M, Kawasaki M, Ishihara Y, Takeyama U, Kubota T, Yamaki T et al (2008) Development of integrated backscatter intravascular ultrasound for tissue characterization of coronary plaques. Ultrasound Med Biol 34(4):655–663PubMedCrossRef
13.
Zurück zum Zitat Kawasaki M, Takatsu H, Noda T, Sano K, Ito Y, Hayakawa K et al (2002) In vivo quantitative tissue characterization of human coronary arterial plaques by use of integrated backscatter intravascular ultrasound and comparison with angioscopic findings. Circulation 105(21):2487–2492PubMedCrossRef Kawasaki M, Takatsu H, Noda T, Sano K, Ito Y, Hayakawa K et al (2002) In vivo quantitative tissue characterization of human coronary arterial plaques by use of integrated backscatter intravascular ultrasound and comparison with angioscopic findings. Circulation 105(21):2487–2492PubMedCrossRef
14.
Zurück zum Zitat Okubo M, Kawasaki M, Ishihara Y, Takeyama U, Yasuda S, Kubota T et al (2008) Tissue characterization of coronary plaques: comparison of integrated backscatter intravascular ultrasound with virtual histology intravascular ultrasound. Circ J 72(10):1631–1639PubMedCrossRef Okubo M, Kawasaki M, Ishihara Y, Takeyama U, Yasuda S, Kubota T et al (2008) Tissue characterization of coronary plaques: comparison of integrated backscatter intravascular ultrasound with virtual histology intravascular ultrasound. Circ J 72(10):1631–1639PubMedCrossRef
15.
Zurück zum Zitat Mehran R, Dangas G, Abizaid AS, Mintz GS, Lansky AJ, Satler LF et al (1999) Angiographic patterns of in-stent restenosis: classification and implications for long-term outcome. Circulation 100(18):1872–1878PubMedCrossRef Mehran R, Dangas G, Abizaid AS, Mintz GS, Lansky AJ, Satler LF et al (1999) Angiographic patterns of in-stent restenosis: classification and implications for long-term outcome. Circulation 100(18):1872–1878PubMedCrossRef
16.
Zurück zum Zitat Chieffo A, Foglieni C, Nodari RL, Briguori C, Sangiorgi G, Latib A et al (2009) Histopathology of clinical coronary restenosis in drug-eluting versus bare metal stents. Am J Cardiol 104(12):1660–1667PubMedCrossRef Chieffo A, Foglieni C, Nodari RL, Briguori C, Sangiorgi G, Latib A et al (2009) Histopathology of clinical coronary restenosis in drug-eluting versus bare metal stents. Am J Cardiol 104(12):1660–1667PubMedCrossRef
17.
Zurück zum Zitat Oikawa Y, Yajima J, Costa MA, Matsuno S, Akabane M, Funada R et al (2010) Intravascular ultrasound, angioscopic and histopathological characterisation of heterogeneous patterns of restenosis after sirolimus-eluting stent implantation: insights into potential “thromborestenosis” phenomenon. EuroIntervention 6(3):380–387PubMedCrossRef Oikawa Y, Yajima J, Costa MA, Matsuno S, Akabane M, Funada R et al (2010) Intravascular ultrasound, angioscopic and histopathological characterisation of heterogeneous patterns of restenosis after sirolimus-eluting stent implantation: insights into potential “thromborestenosis” phenomenon. EuroIntervention 6(3):380–387PubMedCrossRef
18.
Zurück zum Zitat van Beusekom HM, Saia F, Zindler JD, Lemos PA, Swager-Ten Hoor SL, van Leeuwen MA et al (2007) Drug-eluting stents show delayed healing: paclitaxel more pronounced than sirolimus. Eur Heart J 28(8):974–979PubMedCrossRef van Beusekom HM, Saia F, Zindler JD, Lemos PA, Swager-Ten Hoor SL, van Leeuwen MA et al (2007) Drug-eluting stents show delayed healing: paclitaxel more pronounced than sirolimus. Eur Heart J 28(8):974–979PubMedCrossRef
19.
Zurück zum Zitat Costa MA, Sabate M, Angiolillo DJ, Jimenez-Quevedo P, Teirstein P, Carter A et al (2006) Intravascular ultrasound characterization of the “black hole” phenomenon after drug-eluting stent implantation. Am J Cardiol 97(2):203–206PubMedCrossRef Costa MA, Sabate M, Angiolillo DJ, Jimenez-Quevedo P, Teirstein P, Carter A et al (2006) Intravascular ultrasound characterization of the “black hole” phenomenon after drug-eluting stent implantation. Am J Cardiol 97(2):203–206PubMedCrossRef
20.
Zurück zum Zitat Goto K, Shiode N, Shirota K, Fukuda Y, Kitamura F, Tominaga K et al (2009) Pathological finding of sirolimus-eluting stent (SES) restenosis lesion with black hole appearance on intravascular ultrasound. Circ J 73(10):1969–1971PubMedCrossRef Goto K, Shiode N, Shirota K, Fukuda Y, Kitamura F, Tominaga K et al (2009) Pathological finding of sirolimus-eluting stent (SES) restenosis lesion with black hole appearance on intravascular ultrasound. Circ J 73(10):1969–1971PubMedCrossRef
21.
Zurück zum Zitat Kang SJ, Mintz GS, Park DW, Lee SW, Kim YH, Lee CW et al (2010) Tissue characterization of in-stent neointima using intravascular ultrasound radiofrequency data analysis. Am J Cardiol 106(11):1561–1565PubMedCrossRef Kang SJ, Mintz GS, Park DW, Lee SW, Kim YH, Lee CW et al (2010) Tissue characterization of in-stent neointima using intravascular ultrasound radiofrequency data analysis. Am J Cardiol 106(11):1561–1565PubMedCrossRef
22.
Zurück zum Zitat Kang SJ, Mintz GS, Akasaka T, Park DW, Lee JY, Kim WJ et al (2011) Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation. Circulation 123(25):2954–2963PubMedCrossRef Kang SJ, Mintz GS, Akasaka T, Park DW, Lee JY, Kim WJ et al (2011) Optical coherence tomographic analysis of in-stent neoatherosclerosis after drug-eluting stent implantation. Circulation 123(25):2954–2963PubMedCrossRef
23.
Zurück zum Zitat Takano M, Yamamoto M, Inami S, Murakami D, Ohba T, Seino Y et al (2010) Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography. J Am Coll Cardiol 55(1):26–32CrossRef Takano M, Yamamoto M, Inami S, Murakami D, Ohba T, Seino Y et al (2010) Appearance of lipid-laden intima and neovascularization after implantation of bare-metal stents extended late-phase observation by intracoronary optical coherence tomography. J Am Coll Cardiol 55(1):26–32CrossRef
Metadaten
Titel
Evaluation of in-stent neointimal tissue components using integrated backscatter intravascular ultrasound: comparison of drug-eluting stents and bare-metal stents
verfasst von
Yoshitaka Muraoka
Shinjo Sonoda
Kuninobu Kashiyama
Fumihiko Kamezaki
Yuki Tsuda
Masaru Araki
Masahiro Okazaki
Yutaka Otsuji
Publikationsdatum
01.10.2012
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 7/2012
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-011-9997-9

Weitere Artikel der Ausgabe 7/2012

The International Journal of Cardiovascular Imaging 7/2012 Zur Ausgabe

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

Erhöhtes Risiko fürs Herz unter Checkpointhemmer-Therapie

28.05.2024 Nebenwirkungen der Krebstherapie Nachrichten

Kardiotoxische Nebenwirkungen einer Therapie mit Immuncheckpointhemmern mögen selten sein – wenn sie aber auftreten, wird es für Patienten oft lebensgefährlich. Voruntersuchung und Monitoring sind daher obligat.

GLP-1-Agonisten können Fortschreiten diabetischer Retinopathie begünstigen

24.05.2024 Diabetische Retinopathie Nachrichten

Möglicherweise hängt es von der Art der Diabetesmedikamente ab, wie hoch das Risiko der Betroffenen ist, dass sich sehkraftgefährdende Komplikationen verschlimmern.

TAVI versus Klappenchirurgie: Neue Vergleichsstudie sorgt für Erstaunen

21.05.2024 TAVI Nachrichten

Bei schwerer Aortenstenose und obstruktiver KHK empfehlen die Leitlinien derzeit eine chirurgische Kombi-Behandlung aus Klappenersatz plus Bypass-OP. Diese Empfehlung wird allerdings jetzt durch eine aktuelle Studie infrage gestellt – mit überraschender Deutlichkeit.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.