Skip to main content
Erschienen in: Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 2/2011

01.04.2011 | Original article

Pilot study on accuracy and dimensional stability of impression materials using industrial CT technology

verfasst von: Dr. S. Steinhäuser-Andresen, A. Detterbeck, C. Funk, M. Krumm, S. Kasperl, A. Holst, U. Hirschfelder

Erschienen in: Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie | Ausgabe 2/2011

Einloggen, um Zugang zu erhalten

Abstract

Objective

Using computed tomography, scan impressions can be saved and edited as virtual data. The aim of this study was to evaluate the parameters influencing different impression materials and impression trays and their relevance with regard to accuracy and dimensional stability.

Materials and methods

Two alginate impressions (Zhermack Hydrogum®5 and Kaniedenta Tetrachrom®) and a polyether impression (3MEspe Impregum™) were each combined with two acrylic trays (3M Espe Position Tray™ and Profimed Opti-Tray) and CT scanned immediately after impression at the Fraunhofer Institute Development Center for X-ray Technology (EZRT) in Fürth, Germany. Each impression was digitized 10 times on the same day, 3 times after 2 days and twice after 6 days, thus determining the dimensional stability of the various materials. An acrylic model was digitized with a high-resolution µCT research scanner to be used as a reference for assessing the accuracy of the impression materials. For graphic and statistical analysis, VGStudio Max® was used.

Results

Both alginate impressions were less dimensionally stable than the polyether impression material. The Zhermack Hydrogum®5 alginate impression resulted in more deviation (151 µm) after 6 days than the Kaniedenta Tetrachrom® impression. The polyether scans showed a mean deviation of 73 µm. The accuracy of both alginates was similarly precise (mean value: Hydrogum®5 0.129 ± 0.021 mm, Tetrachrom® 0.137 ± 0.002 mm). The type of tray had limited influence on the results of the alginate impressions, while the accuracy of the Impregum™ impression depended on the tray combination chosen.

Conclusion

The accuracy of the alginate impressions is sufficient for clinical use in orthodontics and produced, with correct storage, acceptable results even after 2 days. Hydrogum®5 impressions proved to be slightly more accurate than the reference material but less dimensionally stable than the Tetrachrom® impressions. The 3M Espe Position Tray™ seemed to be more practical due to a better retentive effect compared to the Opti-Tray made by Profimed.
Literatur
1.
Zurück zum Zitat Alcan T, Ceylanoglu C, Baysal B (2009) The relationship between digital model accuracy and time-dependent deformation of alginate impressions. Angle Orthod 79:30–36PubMedCrossRef Alcan T, Ceylanoglu C, Baysal B (2009) The relationship between digital model accuracy and time-dependent deformation of alginate impressions. Angle Orthod 79:30–36PubMedCrossRef
2.
Zurück zum Zitat Boldt F, Weinzierl C, Hertrich K et al (2009) Comparison of the spatial landmark scatter of various 3D digitalization methods. J Orofac Orthop 70:247–263PubMedCrossRef Boldt F, Weinzierl C, Hertrich K et al (2009) Comparison of the spatial landmark scatter of various 3D digitalization methods. J Orofac Orthop 70:247–263PubMedCrossRef
3.
Zurück zum Zitat Bootvong K, Liu Z, McGrath C et al (2010) Virtual model analysis as an alternative approach to plaster model analysis: reliability and validity. Eur J Orthod Epub ahead of print Bootvong K, Liu Z, McGrath C et al (2010) Virtual model analysis as an alternative approach to plaster model analysis: reliability and validity. Eur J Orthod Epub ahead of print
4.
Zurück zum Zitat Costalos PA, Sarraf K, Cangialosi TJ et al (2005) Evaluation of the accuracy of digital model analysis for the American Board of Orthodontics objective grading system for dental casts. Am J Orthod Dentofacial Orthop 128:624–629PubMedCrossRef Costalos PA, Sarraf K, Cangialosi TJ et al (2005) Evaluation of the accuracy of digital model analysis for the American Board of Orthodontics objective grading system for dental casts. Am J Orthod Dentofacial Orthop 128:624–629PubMedCrossRef
5.
Zurück zum Zitat Dalstra M, Melsen B (2009) From alginate impressions to digital virtual models: accuracy and reproducibility. J Orthod 36:36–41; discussion 14PubMedCrossRef Dalstra M, Melsen B (2009) From alginate impressions to digital virtual models: accuracy and reproducibility. J Orthod 36:36–41; discussion 14PubMedCrossRef
6.
Zurück zum Zitat DeLong R, Heinzen M, Hodges JS et al (2003) Accuracy of a system for creating 3D computer models of dental arches. J Dent Res 82:438–442PubMedCrossRef DeLong R, Heinzen M, Hodges JS et al (2003) Accuracy of a system for creating 3D computer models of dental arches. J Dent Res 82:438–442PubMedCrossRef
7.
Zurück zum Zitat Elefteriadis JN, Athanasiou AE (1996) Evaluation of impacted canines by means of computerized tomography. Int J Adult Orthodon Orthognath Surg 11:257–264PubMed Elefteriadis JN, Athanasiou AE (1996) Evaluation of impacted canines by means of computerized tomography. Int J Adult Orthodon Orthognath Surg 11:257–264PubMed
8.
Zurück zum Zitat Endo T, Finger WJ (2006) Dimensional accuracy of a new polyether impression material. Quintessence Int 37:47–51PubMed Endo T, Finger WJ (2006) Dimensional accuracy of a new polyether impression material. Quintessence Int 37:47–51PubMed
9.
Zurück zum Zitat Faria AC, Rodrigues RC, Macedo AP et al (2008) Accuracy of stone casts obtained by different impression materials. Braz Oral Res 22:293–298PubMedCrossRef Faria AC, Rodrigues RC, Macedo AP et al (2008) Accuracy of stone casts obtained by different impression materials. Braz Oral Res 22:293–298PubMedCrossRef
10.
Zurück zum Zitat Hajeer MY, Millett DT, Ayoub AF et al (2004) Applications of 3D imaging in orthodontics: Part II. J Orthod 31:154–162PubMedCrossRef Hajeer MY, Millett DT, Ayoub AF et al (2004) Applications of 3D imaging in orthodontics: Part II. J Orthod 31:154–162PubMedCrossRef
11.
Zurück zum Zitat Hirschinger R (2001) Digital dentistry: information technology for today’s (and tomorrow’s) dental practice. J Calif Dent Assoc 29:215–221, 223–225PubMed Hirschinger R (2001) Digital dentistry: information technology for today’s (and tomorrow’s) dental practice. J Calif Dent Assoc 29:215–221, 223–225PubMed
12.
Zurück zum Zitat Holst S, Blatz MB, Bergler M et al (2007) Influence of impression material and time on the 3-dimensional accuracy of implant impressions. Quintessence Int 38:67–73PubMed Holst S, Blatz MB, Bergler M et al (2007) Influence of impression material and time on the 3-dimensional accuracy of implant impressions. Quintessence Int 38:67–73PubMed
13.
Zurück zum Zitat Horton HM, Miller JR, Gaillard PR et al (2010) Technique comparison for efficient orthodontic tooth measurements using digital models. Angle Orthod 80:254–261PubMedCrossRef Horton HM, Miller JR, Gaillard PR et al (2010) Technique comparison for efficient orthodontic tooth measurements using digital models. Angle Orthod 80:254–261PubMedCrossRef
14.
Zurück zum Zitat Kamegawa M, Nakamura M, Kitahara K et al (2008) 3D morphological assessment of occlusal treatment by measuring dental casts with a micro-focus X-ray CT. J Oral Rehabil 35:382–389PubMedCrossRef Kamegawa M, Nakamura M, Kitahara K et al (2008) 3D morphological assessment of occlusal treatment by measuring dental casts with a micro-focus X-ray CT. J Oral Rehabil 35:382–389PubMedCrossRef
15.
Zurück zum Zitat Kamegawa M, Nakamura M, Tsutsumi S (2008) 3D morphological measurements of dental casts with occlusal relationship using microfocus X-ray CT. Dent Mater J 27:549–554PubMedCrossRef Kamegawa M, Nakamura M, Tsutsumi S (2008) 3D morphological measurements of dental casts with occlusal relationship using microfocus X-ray CT. Dent Mater J 27:549–554PubMedCrossRef
16.
Zurück zum Zitat Kasperl S, Hiller J (2009) Artefaktkorrekturen beim dimensionellen Messen mit industrieller Röntgen-Computertomographie. tm – Technisches Messen 76:401–409 Kasperl S, Hiller J (2009) Artefaktkorrekturen beim dimensionellen Messen mit industrieller Röntgen-Computertomographie. tm – Technisches Messen 76:401–409
17.
Zurück zum Zitat Krumm M, Kasperl S, Franz M (2008) Reducing non-linear artifacts of multi-material objects in industrial 3D computed tomography. NDT & E International 41:242–251 Krumm M, Kasperl S, Franz M (2008) Reducing non-linear artifacts of multi-material objects in industrial 3D computed tomography. NDT & E International 41:242–251
18.
Zurück zum Zitat Li C, Wang G, Xu T et al (2005) Orthodontic simulation and diagnosis: an enhanced tool for dentists. Conf Proc IEEE Eng Med Biol Soc 4:4345–4348PubMed Li C, Wang G, Xu T et al (2005) Orthodontic simulation and diagnosis: an enhanced tool for dentists. Conf Proc IEEE Eng Med Biol Soc 4:4345–4348PubMed
19.
Zurück zum Zitat Loos R (2008) Vergleichende Untersuchung von intraoraler und extraoraler Digitalisierung nach Modellherstellung mit CEREC-3D. Med Diss Med. Fakultät Carl Gustav Carus TU Dresden Loos R (2008) Vergleichende Untersuchung von intraoraler und extraoraler Digitalisierung nach Modellherstellung mit CEREC-3D. Med Diss Med. Fakultät Carl Gustav Carus TU Dresden
20.
Zurück zum Zitat Quimby ML, Vig KW, Rashid RG et al (2004) The accuracy and reliability of measurements made on computer-based digital models. Angle Orthod 74:298–303PubMed Quimby ML, Vig KW, Rashid RG et al (2004) The accuracy and reliability of measurements made on computer-based digital models. Angle Orthod 74:298–303PubMed
21.
Zurück zum Zitat Redlich M, Weinstock T, Abed Y et al (2008) A new system for scanning, measuring and analyzing dental casts based on a 3D holographic sensor. Orthod Craniofac Res 11:90–95PubMedCrossRef Redlich M, Weinstock T, Abed Y et al (2008) A new system for scanning, measuring and analyzing dental casts based on a 3D holographic sensor. Orthod Craniofac Res 11:90–95PubMedCrossRef
22.
Zurück zum Zitat Santoro M, Galkin S, Teredesai M et al (2003) Comparison of measurements made on digital and plaster models. Am J Orthod Dentofacial Orthop 124:101–105PubMedCrossRef Santoro M, Galkin S, Teredesai M et al (2003) Comparison of measurements made on digital and plaster models. Am J Orthod Dentofacial Orthop 124:101–105PubMedCrossRef
23.
Zurück zum Zitat Schwenke H, Härtig F, Neuschaefer-Rube U et al (2007) Koordinatenmesstechnik als Schlüsseltechnologie der mechanischen Produktion – Herausforderungen für die PTB. PTB-Mitt 117:349–345 Schwenke H, Härtig F, Neuschaefer-Rube U et al (2007) Koordinatenmesstechnik als Schlüsseltechnologie der mechanischen Produktion – Herausforderungen für die PTB. PTB-Mitt 117:349–345
24.
Zurück zum Zitat Sedda M, Casarotto A, Raustia A et al (2008) Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids. J Contemp Dent Pract 9:59–66PubMed Sedda M, Casarotto A, Raustia A et al (2008) Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids. J Contemp Dent Pract 9:59–66PubMed
25.
Zurück zum Zitat Sjogren AP, Lindgren JE, Huggare JA (2009) Orthodontic Study Cast analysis-reproducibility of recordings and agreement between conventional and 3D virtual measurements. J Digit Imaging Sjogren AP, Lindgren JE, Huggare JA (2009) Orthodontic Study Cast analysis-reproducibility of recordings and agreement between conventional and 3D virtual measurements. J Digit Imaging
26.
Zurück zum Zitat Stevens DR, Flores-Mir C, Nebbe B et al (2006) Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurements. Am J Orthod Dentofacial Orthop 129:794–803PubMedCrossRef Stevens DR, Flores-Mir C, Nebbe B et al (2006) Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurements. Am J Orthod Dentofacial Orthop 129:794–803PubMedCrossRef
27.
Zurück zum Zitat Tarawneh FM, Panos PG, Athanasiou AE (2008) Three-dimensional assessment of dental casts’ occlusal surfaces using two impression materials. J Oral Rehabil 35:821–826PubMedCrossRef Tarawneh FM, Panos PG, Athanasiou AE (2008) Three-dimensional assessment of dental casts’ occlusal surfaces using two impression materials. J Oral Rehabil 35:821–826PubMedCrossRef
28.
Zurück zum Zitat Veenema AC, Katsaros C, Boxum SC et al (2009) Index of complexity, outcome and need scored on plaster and digital models. Eur J Orthod 31:281–286PubMedCrossRef Veenema AC, Katsaros C, Boxum SC et al (2009) Index of complexity, outcome and need scored on plaster and digital models. Eur J Orthod 31:281–286PubMedCrossRef
29.
Zurück zum Zitat Yan B, Wang L, Hu QS et al (2005) Development and study of three-dimensional CT scanning system for dental cast measurement and analysis. Hua Xi Kou Qiang Yi Xue Za Zhi 23:329–331PubMed Yan B, Wang L, Hu QS et al (2005) Development and study of three-dimensional CT scanning system for dental cast measurement and analysis. Hua Xi Kou Qiang Yi Xue Za Zhi 23:329–331PubMed
Metadaten
Titel
Pilot study on accuracy and dimensional stability of impression materials using industrial CT technology
verfasst von
Dr. S. Steinhäuser-Andresen
A. Detterbeck
C. Funk
M. Krumm
S. Kasperl
A. Holst
U. Hirschfelder
Publikationsdatum
01.04.2011
Verlag
Springer-Verlag
Erschienen in
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie / Ausgabe 2/2011
Print ISSN: 1434-5293
Elektronische ISSN: 1615-6714
DOI
https://doi.org/10.1007/s00056-011-0015-6

Weitere Artikel der Ausgabe 2/2011

Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie 2/2011 Zur Ausgabe

Informationen

DGKFO-Seiten

Parodontalbehandlung verbessert Prognose bei Katheterablation

19.04.2024 Vorhofflimmern Nachrichten

Werden Personen mit Vorhofflimmern in der Blanking-Periode nach einer Katheterablation gegen eine bestehende Parodontitis behandelt, verbessert dies die Erfolgsaussichten. Dafür sprechen die Resultate einer prospektiven Untersuchung.

Invasive Zahnbehandlung: Wann eine Antibiotikaprophylaxe vor infektiöser Endokarditis schützt

11.04.2024 Endokarditis Nachrichten

Bei welchen Personen eine Antibiotikaprophylaxe zur Prävention einer infektiösen Endokarditis nach invasiven zahnärztlichen Eingriffen sinnvoll ist, wird diskutiert. Neue Daten stehen im Einklang mit den europäischen Leitlinienempfehlungen.

Zell-Organisatoren unter Druck: Mechanismen des embryonalen Zahnwachstums aufgedeckt

08.04.2024 Zahnmedizin Nachrichten

Der Aufbau von Geweben und Organen während der Embryonalentwicklung wird von den Zellen bemerkenswert choreografiert. Für diesen Prozess braucht es spezielle sogenannte „Organisatoren“. In einer aktuellen Veröffentlichung im Fachjournal Nature Cell Biology berichten Forschende durch welchen Vorgang diese Organisatoren im Gewebe entstehen und wie sie dann die Bildung von Zähnen orchestrieren.

Die Oralprophylaxe & Kinderzahnheilkunde umbenannt

11.03.2024 Kinderzahnmedizin Nachrichten

Infolge der Umbenennung der Deutschen Gesellschaft für Kinderzahnheilkunde in Deutsche Gesellschaft für Kinderzahnmedizin (DGKiZ) wird deren Mitgliederzeitschrift Oralprophylaxe & Kinderzahnheilkunde in Oralprophylaxe & Kinderzahnmedizin umbenannt. Aus diesem Grunde trägt die erste Ausgabe in 2024 erstmalig den neuen Titel.

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.