Abstract

Since a significant number of implant failures have been reported in association with the procedure of open wedge valgus high tibial osteotomy, the initial biomechanical stability of different fixation devices was investigated in this study. Fifteen third generation Sawbones composite tibiae were used as a model. Four different plates were tested: a short spacer plate (OWO) (n=4), a short spacer plate with multi-directional locking bolts (MSO) (n=5), a prototype version of a long spacer plate with multi-directional locking bolts (MSOnew) (n=2), and a long medial tibia plate fixator with locking bolts (MPF) (n=4). All opening wedge osteotomies were performed by the same surgeon (PL) in a standardized fashion. Axial compression of the tibiae was performed using a materials testing machine under standardized alignment of the loading axis. Single load to failure tests as well as load-controlled cyclical failure tests were performed. The required force and cycles to failure were recorded. Osteotomy gap motion was measured using linear displacement transducers. Residual stability after failure of the opposite lateral cortex was analysed. Failure occurred at the lateral cortex bone-bride in all tested implants. The rigid long plate fixator (MPF) resisted the greatest amount of force (2,881 N) in the single load to failure tests. In the cyclical load-to-failure tests, the constructs with MPF resisted more than twice the amount of loading cycles when compared to the short spacer plates. The osteotomy gap motion was smallest in the MPF, with a reduction of the displacements of up to 65, 66 and 88%, when compared to OWO, MSO and MSOnew, respectively. The highest residual stability after failure of the lateral cortex was observed in MPF as well. The results suggest that the implant design strongly influences the primary stability of medial opening wedge tibial osteotomy. A rigid long plate fixator with angle-stable locking bolts yields the best results.
Literatur
1.
Zurück zum Zitat Bauer T, Hardy P, Lemoine J, Finlayson DF, Tranier S, Lortat-Jacob A (2005) Drop foot after high tibial osteotomy: a prospective study of aetiological factors. Knee Surg Sports Traumatol Arthrosc 13(1):23–33CrossRefPubMed Bauer T, Hardy P, Lemoine J, Finlayson DF, Tranier S, Lortat-Jacob A (2005) Drop foot after high tibial osteotomy: a prospective study of aetiological factors. Knee Surg Sports Traumatol Arthrosc 13(1):23–33CrossRefPubMed
2.
Zurück zum Zitat Coventry MB, Ilstrup DM, Wallrichs SL (1993) Proximal tibial osteotomy. A critical long-term study of eighty-seven cases. J Bone Joint Surg Am 75(2):196–201PubMed Coventry MB, Ilstrup DM, Wallrichs SL (1993) Proximal tibial osteotomy. A critical long-term study of eighty-seven cases. J Bone Joint Surg Am 75(2):196–201PubMed
3.
Zurück zum Zitat Cristofolini L, Viceconti M (2000) Mechanical validation of whole bone composite tibia models. J Biomech 33(3):279–288CrossRefPubMed Cristofolini L, Viceconti M (2000) Mechanical validation of whole bone composite tibia models. J Biomech 33(3):279–288CrossRefPubMed
4.
Zurück zum Zitat Flamme CH, Kohn D, Kirsch L, Hurschler C (1999) Primary stability of different implants used in conjunction with high tibial osteotomy. Arch Orthop Trauma Surg 119(7–8):450–455CrossRefPubMed Flamme CH, Kohn D, Kirsch L, Hurschler C (1999) Primary stability of different implants used in conjunction with high tibial osteotomy. Arch Orthop Trauma Surg 119(7–8):450–455CrossRefPubMed
5.
Zurück zum Zitat Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10(3):585–608PubMed Fujisawa Y, Masuhara K, Shiomi S (1979) The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints. Orthop Clin North Am 10(3):585–608PubMed
6.
Zurück zum Zitat Heiner AD, Brown TD (2001) Structural properties of a new design of composite replicate femurs and tibias. J Biomech 34(6):773–781CrossRefPubMed Heiner AD, Brown TD (2001) Structural properties of a new design of composite replicate femurs and tibias. J Biomech 34(6):773–781CrossRefPubMed
7.
Zurück zum Zitat Korovessis P, Katsoudas G, Salonikides P, Stamatakis M, Baikousis A (1999) Medium- and long-term results of high tibial osteotomy for varus gonarthrosis in an agricultural population. Orthopedics 22(8):729–736PubMed Korovessis P, Katsoudas G, Salonikides P, Stamatakis M, Baikousis A (1999) Medium- and long-term results of high tibial osteotomy for varus gonarthrosis in an agricultural population. Orthopedics 22(8):729–736PubMed
8.
Zurück zum Zitat Lobenhoffer P, Agneskirchner J, Zoch W (2004) Open valgus alignment osteotomy of the proximal tibia with fixation by medial plate fixator. Orthopäde 33(2):153–160CrossRefPubMed Lobenhoffer P, Agneskirchner J, Zoch W (2004) Open valgus alignment osteotomy of the proximal tibia with fixation by medial plate fixator. Orthopäde 33(2):153–160CrossRefPubMed
9.
Zurück zum Zitat Lobenhoffer P, Agneskirchner J, Zoch W (2004) Open-wedge high tibial osteotomy with special medial plate fixator. Orthopäde 33(2):153–160CrossRefPubMed Lobenhoffer P, Agneskirchner J, Zoch W (2004) Open-wedge high tibial osteotomy with special medial plate fixator. Orthopäde 33(2):153–160CrossRefPubMed
10.
Zurück zum Zitat Lobenhoffer P, Agneskirchner JD (2003) Improvements in surgical technique of valgus high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 11(3):132–138PubMed Lobenhoffer P, Agneskirchner JD (2003) Improvements in surgical technique of valgus high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 11(3):132–138PubMed
11.
Zurück zum Zitat Lobenhoffer P, De Simoni C, Staubli AE (2002) Open wedge high-tibial osteotomy with rigid plate fixation. Tech Knee Surg 1(2):93–105 Lobenhoffer P, De Simoni C, Staubli AE (2002) Open wedge high-tibial osteotomy with rigid plate fixation. Tech Knee Surg 1(2):93–105
12.
Zurück zum Zitat Lootvoet L, Massinon A, Rossillon R, Himmer O, Lambert K, Ghosez JP (1993) Upper tibial osteotomy for gonarthrosis in genu varum. Apropos of a series of 193 cases reviewed 6 to 10 years later. Rev Chir Orthop Reparatrice Appar Mot 79(5):375–384PubMed Lootvoet L, Massinon A, Rossillon R, Himmer O, Lambert K, Ghosez JP (1993) Upper tibial osteotomy for gonarthrosis in genu varum. Apropos of a series of 193 cases reviewed 6 to 10 years later. Rev Chir Orthop Reparatrice Appar Mot 79(5):375–384PubMed
13.
Zurück zum Zitat Odenbring S, Egund N, Knutson K, Lindstrand A, Larsen ST (1990) Revision after osteotomy for gonarthrosis. A 10-19-year follow-up of 314 cases. Acta Orthop Scand 61(2):128–130PubMed Odenbring S, Egund N, Knutson K, Lindstrand A, Larsen ST (1990) Revision after osteotomy for gonarthrosis. A 10-19-year follow-up of 314 cases. Acta Orthop Scand 61(2):128–130PubMed
14.
Zurück zum Zitat Spahn G, Wittig R (2002) Primary stability of various implants in tibial opening wedge osteotomy: a biomechanical study. J Orthop Sci 7(6):683–687CrossRefPubMed Spahn G, Wittig R (2002) Primary stability of various implants in tibial opening wedge osteotomy: a biomechanical study. J Orthop Sci 7(6):683–687CrossRefPubMed
15.
Zurück zum Zitat Stoffel K, Stachowiak G, Kuster M (2004) Open wedge high tibial osteotomy: biomechanical investigation of the modified arthrex osteotomy plate (Puddu plate) and the TomoFix Plate. Clin Biomech (Bristol, Avon) 19(9):944–950 Stoffel K, Stachowiak G, Kuster M (2004) Open wedge high tibial osteotomy: biomechanical investigation of the modified arthrex osteotomy plate (Puddu plate) and the TomoFix Plate. Clin Biomech (Bristol, Avon) 19(9):944–950
16.
Zurück zum Zitat Warden SJ, Morris HG, Crossley KM, Brukner PD, Bennell KL (2005) Delayed- and non-union following opening wedge high tibial osteotomy: surgeons’ results from 182 completed cases. Knee Surg Sports Traumatol Arthrosc 13(1):34–37CrossRefPubMed Warden SJ, Morris HG, Crossley KM, Brukner PD, Bennell KL (2005) Delayed- and non-union following opening wedge high tibial osteotomy: surgeons’ results from 182 completed cases. Knee Surg Sports Traumatol Arthrosc 13(1):34–37CrossRefPubMed
Metadaten
Titel
Primary stability of four different implants for opening wedge high tibial osteotomy
verfasst von
J. D. Agneskirchner
D. Freiling
C. Hurschler
P. Lobenhoffer
Publikationsdatum
01.03.2006
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 3/2006
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-005-0690-1

Weitere Artikel der Ausgabe 3/2006

Knee Surgery, Sports Traumatology, Arthroscopy 3/2006 Zur Ausgabe

Editorial

Knee anatomy

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.