Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 12/2010

01.12.2010 | Shoulder

Clinical and structural evaluation of arthroscopic double-row suture-bridge rotator cuff repair: early results of a novel technique

verfasst von: H. El-Azab, S. Buchmann, K. Beitzel, S. Waldt, Andreas B. Imhoff

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 12/2010

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Assessment of repair integrity and clinical outcome after arthroscopic repair of rotator cuff tears in double-row suture-bridge technique with the use of a new knotless suture-anchor system.

Methods

The first treated 25 patients with arthroscopic rotator cuff repair in the suture-bridge technique using a novel knotless anchor and chain-link suture system were evaluated. Patients with isolated full-thickness supraspinatus tears were selected. They were followed clinically with functional scores (Constant score, ASES index), visual analog scale (VAS), and instrumentally with Isobex digital strength analyzer preoperatively, at 6 and 14 months postoperatively. The repair integrity was evaluated with MRI at an average of 14 months postoperatively.

Results

Significant improvement of pain, strength, range of motion, and functional scores occurred (P < 0.05). There was a re-tear rate of 20%. The subjective parameters (VAS and ASES Index) showed non-significant (n.s.) differences between the re-tear and intact repair groups, whereas the objective parameters (Constant score, muscle power and active ROM) showed significant differences between both groups (P < 0.05).

Conclusion

The functional outcome has improved significantly with this new knotless anchor-chain system and was more superior in shoulders with intact repair, whereas the resulted repair integrity was not better than other types of double-row repair techniques mentioned in the recent literature. However, this early report of the novel technique may show limited power for comparison due to the relatively small sample size.
Literatur
1.
Zurück zum Zitat Bigliani LU, Morrison DS (1986) The morphology of the acromion and its relationship to rotator cuff tears. Orthop Trans 10:228–234 Bigliani LU, Morrison DS (1986) The morphology of the acromion and its relationship to rotator cuff tears. Orthop Trans 10:228–234
2.
Zurück zum Zitat Burkhart SS, Cole BJ (2010) Bridging self-reinforcing double-row rotator cuff repair: we really are doing better. Arthroscopy 26:677–680CrossRefPubMed Burkhart SS, Cole BJ (2010) Bridging self-reinforcing double-row rotator cuff repair: we really are doing better. Arthroscopy 26:677–680CrossRefPubMed
3.
Zurück zum Zitat Burkhart SS, Adams CR, Schoolfield JD (2009) A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: the SwiveLock-FiberChain construct versus standard double-row repair. Arthroscopy 25:274–281CrossRefPubMed Burkhart SS, Adams CR, Schoolfield JD (2009) A biomechanical comparison of 2 techniques of footprint reconstruction for rotator cuff repair: the SwiveLock-FiberChain construct versus standard double-row repair. Arthroscopy 25:274–281CrossRefPubMed
4.
Zurück zum Zitat Codman AE (1934) The shoulder: rupture of the supraspinatus tendon and other lesions in or about the subacromial bursa. Todd, Boston Codman AE (1934) The shoulder: rupture of the supraspinatus tendon and other lesions in or about the subacromial bursa. Todd, Boston
5.
Zurück zum Zitat Cole BJ, ElAttrache NS, Anbari A (2007) Arthroscopic rotator cuff repairs: an anatomic and biomechanical rationale for different suture-anchor repair configurations. Arthroscopy 23:662–669CrossRefPubMed Cole BJ, ElAttrache NS, Anbari A (2007) Arthroscopic rotator cuff repairs: an anatomic and biomechanical rationale for different suture-anchor repair configurations. Arthroscopy 23:662–669CrossRefPubMed
6.
Zurück zum Zitat Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164PubMed Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164PubMed
7.
Zurück zum Zitat Frank JB, ElAttrache NS, Dines JS, Blackburn A, Crues J, Tibone JE (2008) Repair site integrity after arthroscopic transosseous-equivalent suture-bridge rotator cuff repair. Am J Sports Med 36:1496–1503CrossRefPubMed Frank JB, ElAttrache NS, Dines JS, Blackburn A, Crues J, Tibone JE (2008) Repair site integrity after arthroscopic transosseous-equivalent suture-bridge rotator cuff repair. Am J Sports Med 36:1496–1503CrossRefPubMed
8.
Zurück zum Zitat Fuchs B, Weishaupt D, Zanetti M, Hodler J, Gerber C (1999) Fatty degeneration of the muscles of the rotator cuff: assessment by computed tomography versus magnetic resonance imaging. J Should Elbow Surg 8:599–605CrossRef Fuchs B, Weishaupt D, Zanetti M, Hodler J, Gerber C (1999) Fatty degeneration of the muscles of the rotator cuff: assessment by computed tomography versus magnetic resonance imaging. J Should Elbow Surg 8:599–605CrossRef
9.
Zurück zum Zitat Gerber C, Schneeberger AG, Hoppeler H, Meyer DC (2007) Correlation of atrophy and fatty infiltration on strength and integrity of rotator cuff repairs: a study in thirteen patients. J Should Elbow Surg 16:691–696CrossRef Gerber C, Schneeberger AG, Hoppeler H, Meyer DC (2007) Correlation of atrophy and fatty infiltration on strength and integrity of rotator cuff repairs: a study in thirteen patients. J Should Elbow Surg 16:691–696CrossRef
10.
Zurück zum Zitat Goutallier D, Postel JM, Radier C, Bernageau J, Zilber S (2009) Long-term functional and structural outcome in patients with intact repairs 1 year after open transosseous rotator cuff repair. J Should Elbow Surg 18:521–528CrossRef Goutallier D, Postel JM, Radier C, Bernageau J, Zilber S (2009) Long-term functional and structural outcome in patients with intact repairs 1 year after open transosseous rotator cuff repair. J Should Elbow Surg 18:521–528CrossRef
11.
Zurück zum Zitat Grimberg J, Diop A, Kalra K, Charousset C, Duranthon LD, Maurel N (2010) In vitro biomechanical comparison of three different types of single- and double-row arthroscopic rotator cuff repairs: Analysis of continuous bone-tendon contact pressure and surface during different simulated joint positions. J Should Elbow Surg 19:236–243CrossRef Grimberg J, Diop A, Kalra K, Charousset C, Duranthon LD, Maurel N (2010) In vitro biomechanical comparison of three different types of single- and double-row arthroscopic rotator cuff repairs: Analysis of continuous bone-tendon contact pressure and surface during different simulated joint positions. J Should Elbow Surg 19:236–243CrossRef
12.
Zurück zum Zitat Harryman DT II, Mack LA, Wang KY, Jackins SE, Richardson ML, Matsen FA (1991) Repairs of the rotator cuff. Correlation of functional results with integrity of the cuff. J Bone Joint Surg Am 73:982–989PubMed Harryman DT II, Mack LA, Wang KY, Jackins SE, Richardson ML, Matsen FA (1991) Repairs of the rotator cuff. Correlation of functional results with integrity of the cuff. J Bone Joint Surg Am 73:982–989PubMed
13.
Zurück zum Zitat Huijsmans PE, Pritchard MP, Berghs BM, van Rooyen KS, Wallace AL, de Beer JF (2007) Arthroscopic rotator cuff repair with double-row fixation. J Bone Joint Surg Am 89:1248–1257CrossRefPubMed Huijsmans PE, Pritchard MP, Berghs BM, van Rooyen KS, Wallace AL, de Beer JF (2007) Arthroscopic rotator cuff repair with double-row fixation. J Bone Joint Surg Am 89:1248–1257CrossRefPubMed
14.
Zurück zum Zitat Kim KC, Rhee KJ, Shin HD (2009) Revision of a pull-out suture anchor in the lateral row during the suture-bridge technique: technical note. Knee Surg Sports Traumatol Arthrosc 17:1463–1465CrossRefPubMed Kim KC, Rhee KJ, Shin HD (2009) Revision of a pull-out suture anchor in the lateral row during the suture-bridge technique: technical note. Knee Surg Sports Traumatol Arthrosc 17:1463–1465CrossRefPubMed
15.
Zurück zum Zitat Kim KC, Rhee KJ, Shin HD, Kim PS (2009) Arthroscopic footprint reconstruction of bursal-side delaminated rotator cuff tears using the suture-bridge technique. Knee Surg Sports Traumatol Arthrosc 17:840–843CrossRefPubMed Kim KC, Rhee KJ, Shin HD, Kim PS (2009) Arthroscopic footprint reconstruction of bursal-side delaminated rotator cuff tears using the suture-bridge technique. Knee Surg Sports Traumatol Arthrosc 17:840–843CrossRefPubMed
16.
Zurück zum Zitat Klepps S, Bishop J, Lin J, Strauss A, Hayes P, Flatow EL (2004) Prospective evaluation of the effect of rotator cuff integrity on the outcome of open rotator cuff repairs. Am J Sports Med 32:1716–1722CrossRefPubMed Klepps S, Bishop J, Lin J, Strauss A, Hayes P, Flatow EL (2004) Prospective evaluation of the effect of rotator cuff integrity on the outcome of open rotator cuff repairs. Am J Sports Med 32:1716–1722CrossRefPubMed
17.
Zurück zum Zitat Lafosse L, Brozska R, Toussaint B, Gobezie R (2007) The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique. J Bone Joint Surg Am 89:1533–1541CrossRefPubMed Lafosse L, Brozska R, Toussaint B, Gobezie R (2007) The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique. J Bone Joint Surg Am 89:1533–1541CrossRefPubMed
18.
Zurück zum Zitat Liu SH, Baker CL (1994) Arthroscopically assisted rotator cuff repair: correlation of functional results with integrity of the cuff. Arthroscopy 10:54–60CrossRefPubMed Liu SH, Baker CL (1994) Arthroscopically assisted rotator cuff repair: correlation of functional results with integrity of the cuff. Arthroscopy 10:54–60CrossRefPubMed
19.
Zurück zum Zitat Nho SJ, Adler RS, Tomlinson DP et al (2009) Arthroscopic rotator cuff repair: prospective evaluation with sequential ultrasonography. Am J Sports Med 37:1938–1945CrossRefPubMed Nho SJ, Adler RS, Tomlinson DP et al (2009) Arthroscopic rotator cuff repair: prospective evaluation with sequential ultrasonography. Am J Sports Med 37:1938–1945CrossRefPubMed
20.
Zurück zum Zitat Park JY, Siti HT, Keum JS, Moon SG, Oh KS (2009) Does an Arthroscopic Suture Bridge Technique Maintain Repair Integrity?: A Serial Evaluation by Ultrasonography. Clin Orthop Relat Res. 468(6):1578–1587CrossRefPubMed Park JY, Siti HT, Keum JS, Moon SG, Oh KS (2009) Does an Arthroscopic Suture Bridge Technique Maintain Repair Integrity?: A Serial Evaluation by Ultrasonography. Clin Orthop Relat Res. 468(6):1578–1587CrossRefPubMed
21.
Zurück zum Zitat Park MC, ElAttrache NS, Tibone JE, Ahmad CS, Jun BJ, Lee TQ (2007) Part I: footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Should Elbow Surg 16:461–468CrossRef Park MC, ElAttrache NS, Tibone JE, Ahmad CS, Jun BJ, Lee TQ (2007) Part I: footprint contact characteristics for a transosseous-equivalent rotator cuff repair technique compared with a double-row repair technique. J Should Elbow Surg 16:461–468CrossRef
22.
Zurück zum Zitat Patte D (1990) Classification of rotator cuff lesions. Clin Orthop Relat Res. 254:81–86PubMed Patte D (1990) Classification of rotator cuff lesions. Clin Orthop Relat Res. 254:81–86PubMed
23.
Zurück zum Zitat Richards RRBL, Friedman RJ, Gartsman GM, Lannotti JP (1994) A standardaized method for assessment of shoulder function. J Should Elbow Surg 3:347–352CrossRef Richards RRBL, Friedman RJ, Gartsman GM, Lannotti JP (1994) A standardaized method for assessment of shoulder function. J Should Elbow Surg 3:347–352CrossRef
24.
Zurück zum Zitat Rockwood CABW (1988) Management of patients with massive rotator cuff defects by acromioplasty and rotator cuff debridement. Orthop Trans. 12:190–199 Rockwood CABW (1988) Management of patients with massive rotator cuff defects by acromioplasty and rotator cuff debridement. Orthop Trans. 12:190–199
25.
Zurück zum Zitat Snyder SJ (1993) Evaluation and treatment of the rotator cuff. Orthop Clin North Am 24:173–192PubMed Snyder SJ (1993) Evaluation and treatment of the rotator cuff. Orthop Clin North Am 24:173–192PubMed
26.
Zurück zum Zitat Spang JT, Buchmann S, Brucker PU, Kouloumentas P, Obst T, Imhoff AB (2009) A biomechanical comparison of 2 transosseous-equivalent double-row rotator cuff repair techniques using bioabsorbable anchors: cyclic loading and failure behavior. Arthroscopy 25:872–879CrossRefPubMed Spang JT, Buchmann S, Brucker PU, Kouloumentas P, Obst T, Imhoff AB (2009) A biomechanical comparison of 2 transosseous-equivalent double-row rotator cuff repair techniques using bioabsorbable anchors: cyclic loading and failure behavior. Arthroscopy 25:872–879CrossRefPubMed
27.
Zurück zum Zitat Sugaya H, Maeda K, Matsuki K, Moriishi J (2007) Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study. J Bone Joint Surg Am 89:953–960CrossRefPubMed Sugaya H, Maeda K, Matsuki K, Moriishi J (2007) Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study. J Bone Joint Surg Am 89:953–960CrossRefPubMed
28.
Zurück zum Zitat Thomazeau H, Rolland Y, Lucas C, Duval JM, Langlais F (1996) Atrophy of the supraspinatus belly. Assessment by MRI in 55 patients with rotator cuff pathology. Acta Orthop Scand 67:264–268CrossRefPubMed Thomazeau H, Rolland Y, Lucas C, Duval JM, Langlais F (1996) Atrophy of the supraspinatus belly. Assessment by MRI in 55 patients with rotator cuff pathology. Acta Orthop Scand 67:264–268CrossRefPubMed
29.
Zurück zum Zitat Zanetti M, Gerber C, Hodler J (1998) Quantitative assessment of the muscles of the rotator cuff with magnetic resonance imaging. Invest Radiol 33:163–170CrossRefPubMed Zanetti M, Gerber C, Hodler J (1998) Quantitative assessment of the muscles of the rotator cuff with magnetic resonance imaging. Invest Radiol 33:163–170CrossRefPubMed
Metadaten
Titel
Clinical and structural evaluation of arthroscopic double-row suture-bridge rotator cuff repair: early results of a novel technique
verfasst von
H. El-Azab
S. Buchmann
K. Beitzel
S. Waldt
Andreas B. Imhoff
Publikationsdatum
01.12.2010
Verlag
Springer-Verlag
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 12/2010
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-010-1257-3

Weitere Artikel der Ausgabe 12/2010

Knee Surgery, Sports Traumatology, Arthroscopy 12/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Sind Frauen die fähigeren Ärzte?

30.04.2024 Gendermedizin Nachrichten

Patienten, die von Ärztinnen behandelt werden, dürfen offenbar auf bessere Therapieergebnisse hoffen als Patienten von Ärzten. Besonders gilt das offenbar für weibliche Kranke, wie eine Studie zeigt.

Notfall-TEP der Hüfte ist auch bei 90-Jährigen machbar

26.04.2024 Hüft-TEP Nachrichten

Ob bei einer Notfalloperation nach Schenkelhalsfraktur eine Hemiarthroplastik oder eine totale Endoprothese (TEP) eingebaut wird, sollte nicht allein vom Alter der Patientinnen und Patienten abhängen. Auch über 90-Jährige können von der TEP profitieren.

Arthroskopie kann Knieprothese nicht hinauszögern

25.04.2024 Gonarthrose Nachrichten

Ein arthroskopischer Eingriff bei Kniearthrose macht im Hinblick darauf, ob und wann ein Gelenkersatz fällig wird, offenbar keinen Unterschied.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.