Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 8/2011

01.08.2011 | Basic Science

Structural properties of a new fixation strategy in double bundle ACL reconstruction: the MiniShim

verfasst von: S. Lenschow, B. Schliemann, K. Dressler, B. Zampogna, S. Vasta, M. Raschke, T. Zantop

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 8/2011

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Double-bundle reconstruction of the ACL has become the focus of scientific and clinical interest in the last years. However, there is still a discussion about the most appropriate technique for graft fixation. Both, extracortical fixation systems like the Endobutton and aperture fixation by interference screws have advantages as well as disadvantages. Aim of this study was to analyze the biomechanical properties of a new small wedge shaped implant (MiniShim, Karl Storz, Germany) for the fixation of a soft tissue graft in double bundle ACL reconstruction and to compare it to an aperture fixation by interference screw and an extracortical fixation.

Methods

Porcine knees and flexor tendons were used for this study. 5 and 6 mm tunnels were drilled. The following fixation strategies were tested: 4 and 5 mm MiniShim (Karl Storz Germany), 6 mm interference screw (MegaFix, Karl Storz, Germany), hybridfixation by FlippTack (FlippTack, Karl Storz, Germany) and MiniShim and hybridfixation by FlippTack and 6 mm interference screw. All fixation strategies were tested with a 5 and 6 mm tendon graft. Maximum load, yield load and stiffness were recorded using a material testing machine. Load was applied in line with the bone tunnel. Grafts were cyclically preconditioned between 0 and 20 N for 10 cycles before the graft–bone-complex was loaded to failure. Statistical evaluation was performed using SPSS Version 11.0.

Results

Load to failure for the 5 mm graft was 81.1 and 118.0 N for the 4 and 5 mm MiniShims. Fixation by interference screw reached 237.4 N. The extracortical fixation resulted in a load to failure of 471.7 N. Load to failure for the 6 mm tendon grafts was 52.0 and 92.8 N for the 4 and 5 mm MiniShims. Fixation by interference screw resulted in a load to failure of 214.0 N. Extracortical fixation failed at 451.7 N. The difference between MiniShim and interference screw was statistically significant. Load to failure was significantly higher for extracortical fixation compared to fixation by MiniShim or interference screw. Hybrid fixation showed higher fixation strength compared to fixation by interference screw or MiniShim alone. This difference was statistically significant. Stiffness was significantly higher for fixation by interference screw compared to extracortical fixation and fixation by MiniShim. Four different modes of failure could be seen. All 4 mm MiniShims failed by slippage of the tendon past the MiniShim. In the 5 mm group the fixation failed by pullout of the MiniShim or the tendon past the MiniShim. Hybrid fixation failed by rupture of the linkage material. When the graft was fixed by an interference screw failure occurred by rupture of the tendon at the fixation side.

Conclusion

Hybrid fixation using the MiniShim provides biomechanical properties strong enough to withstand the forces occurring during rehabilitation and comparable to the fixation strength provided by interference screw. While fixation by MiniShim alone does not provide sufficient fixation strength in double bundle ACL reconstruction, hybridfixation using a cortical fixation by FlippTack is an alternative to aperture fixation by interference screw concerning primary stability.
Literatur
1.
Zurück zum Zitat Aglietti P, Giron F, Cuomo P, Losco M, Mondanelli N (2007) Single-and double-incision double-bundle ACL reconstruction. Clin Orthop Relat Res 454:108–113PubMedCrossRef Aglietti P, Giron F, Cuomo P, Losco M, Mondanelli N (2007) Single-and double-incision double-bundle ACL reconstruction. Clin Orthop Relat Res 454:108–113PubMedCrossRef
2.
Zurück zum Zitat Beynnon BD, Johnson RJ, Abate JA, Fleming BC, Nichols CE (2005) Treatment of anterior cruciate ligament injuries, part 2. Am J Sports Med 33(11):1751–1767PubMedCrossRef Beynnon BD, Johnson RJ, Abate JA, Fleming BC, Nichols CE (2005) Treatment of anterior cruciate ligament injuries, part 2. Am J Sports Med 33(11):1751–1767PubMedCrossRef
3.
Zurück zum Zitat Beynnon BD, Johnson RJ, Abate JA, Fleming BC, Nichols CE (2005) Treatment of anterior cruciate ligament injuries, part I. Am J Sports Med 33(10):1579–1602PubMedCrossRef Beynnon BD, Johnson RJ, Abate JA, Fleming BC, Nichols CE (2005) Treatment of anterior cruciate ligament injuries, part I. Am J Sports Med 33(10):1579–1602PubMedCrossRef
4.
Zurück zum Zitat Beynnon BD, Uh BS, Johnson RJ et al (2005) Rehabilitation after anterior cruciate ligament reconstruction: a prospective, randomized, double-blind comparison of programs administered over 2 different time intervals. Am J Sports Med 33(3):347–359PubMedCrossRef Beynnon BD, Uh BS, Johnson RJ et al (2005) Rehabilitation after anterior cruciate ligament reconstruction: a prospective, randomized, double-blind comparison of programs administered over 2 different time intervals. Am J Sports Med 33(3):347–359PubMedCrossRef
5.
Zurück zum Zitat Brand J Jr, Weiler A, Caborn DN, Brown CH Jr, Johnson DL (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28(5):761–774PubMed Brand J Jr, Weiler A, Caborn DN, Brown CH Jr, Johnson DL (2000) Graft fixation in cruciate ligament reconstruction. Am J Sports Med 28(5):761–774PubMed
6.
Zurück zum Zitat Brown GA, Pena F, Grontvedt T, Labadie D, Engebretsen L (1996) Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees: influence of insertion torque, tunnel-bone block gap, and interference. Knee Surg Sports Traumatol Arthrosc 3(4):238–244PubMedCrossRef Brown GA, Pena F, Grontvedt T, Labadie D, Engebretsen L (1996) Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees: influence of insertion torque, tunnel-bone block gap, and interference. Knee Surg Sports Traumatol Arthrosc 3(4):238–244PubMedCrossRef
7.
Zurück zum Zitat Daniel DM, Stone ML, Dobson BE, Fithian DC, Rossman DJ, Kaufman KR (1994) Fate of the ACL-injured patient. A prospective outcome study. Am J Sports Med 22(5):632–644PubMedCrossRef Daniel DM, Stone ML, Dobson BE, Fithian DC, Rossman DJ, Kaufman KR (1994) Fate of the ACL-injured patient. A prospective outcome study. Am J Sports Med 22(5):632–644PubMedCrossRef
8.
Zurück zum Zitat Ferrari JD, BachB (2001) Isolated anterior cruciate ligament injury. In: Chapman MW (ed) Chap-man’s orthopedic surgery.Lippincott, Williams & Wilkins, Philadelphia Ferrari JD, BachB (2001) Isolated anterior cruciate ligament injury. In: Chapman MW (ed) Chap-man’s orthopedic surgery.Lippincott, Williams & Wilkins, Philadelphia
9.
Zurück zum Zitat Franceschi JP, Sbihi A, Champsaur P (2002) Arthroscopic reconstruction of the anterior cruciate ligament using double anteromedial and posterolateral bundles. Rev Chir Orthop Reparatrice Appar Mot 88(7):691–697PubMed Franceschi JP, Sbihi A, Champsaur P (2002) Arthroscopic reconstruction of the anterior cruciate ligament using double anteromedial and posterolateral bundles. Rev Chir Orthop Reparatrice Appar Mot 88(7):691–697PubMed
10.
Zurück zum Zitat Frank CB, Jackson DW (1997) The science of reconstruction of the anterior cruciate ligament. J Bone Joint Surg Am 79(10):1556–1576PubMed Frank CB, Jackson DW (1997) The science of reconstruction of the anterior cruciate ligament. J Bone Joint Surg Am 79(10):1556–1576PubMed
11.
Zurück zum Zitat Giurea M, Zorilla P, Amis AA, Aichroth P (1999) Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction. Am J Sports Med 27(5):621–625PubMed Giurea M, Zorilla P, Amis AA, Aichroth P (1999) Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction. Am J Sports Med 27(5):621–625PubMed
12.
Zurück zum Zitat Holden JP, Grood ES, Korvick DL, Cummings JF, Butler DL, Bylski-Austrow DI (1994) In vivo forces in the anterior cruciate ligament: direct measurements during walking and trotting in a quadruped. J Biomech 27(5):517–526PubMedCrossRef Holden JP, Grood ES, Korvick DL, Cummings JF, Butler DL, Bylski-Austrow DI (1994) In vivo forces in the anterior cruciate ligament: direct measurements during walking and trotting in a quadruped. J Biomech 27(5):517–526PubMedCrossRef
13.
Zurück zum Zitat Hulstyn M, Fadale PD, Abate J, Walsh WR (1993) Biomechanical evaluation of interference screw fixation in a bovine patellar bone-tendon-bone autograft complex for anterior cruciate ligament reconstruction. Arthroscopy 9(4):417–424PubMedCrossRef Hulstyn M, Fadale PD, Abate J, Walsh WR (1993) Biomechanical evaluation of interference screw fixation in a bovine patellar bone-tendon-bone autograft complex for anterior cruciate ligament reconstruction. Arthroscopy 9(4):417–424PubMedCrossRef
14.
Zurück zum Zitat Kondo E, Yasuda K, Azuma H, Tanabe Y, Yagi T (2008) Prospective clinical comparisons of anatomic double-bundle versus single-bundle anterior cruciate ligament reconstruction procedures in 328 consecutive patients. Am J Sports Med 36(9):1675–1687PubMedCrossRef Kondo E, Yasuda K, Azuma H, Tanabe Y, Yagi T (2008) Prospective clinical comparisons of anatomic double-bundle versus single-bundle anterior cruciate ligament reconstruction procedures in 328 consecutive patients. Am J Sports Med 36(9):1675–1687PubMedCrossRef
15.
Zurück zum Zitat Kurosaka M, Yoshiya S, Andrish JT (1987) A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction. Am J Sports Med 15(3):225–229PubMedCrossRef Kurosaka M, Yoshiya S, Andrish JT (1987) A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstruction. Am J Sports Med 15(3):225–229PubMedCrossRef
16.
Zurück zum Zitat Lehmann AK, Osada N, Zantop T, Raschke MJ, Petersen W (2009) Femoral bridge stability in double-bundle ACL reconstruction: impact of bridge width and different fixation techniques on the structural properties of the graft/femur complex. Arch Orthop Trauma Surg 129(8):1127–1132PubMedCrossRef Lehmann AK, Osada N, Zantop T, Raschke MJ, Petersen W (2009) Femoral bridge stability in double-bundle ACL reconstruction: impact of bridge width and different fixation techniques on the structural properties of the graft/femur complex. Arch Orthop Trauma Surg 129(8):1127–1132PubMedCrossRef
17.
Zurück zum Zitat Lenschow S, Herbort M, Strasser A et al (2011) Structural properties of a new device for graft fixation in cruciate ligament reconstruction: the shim technique. Arch Orthop Trauma Surg Lenschow S, Herbort M, Strasser A et al (2011) Structural properties of a new device for graft fixation in cruciate ligament reconstruction: the shim technique. Arch Orthop Trauma Surg
18.
Zurück zum Zitat Liu SH, Kabo JM, Osti L (1995) Biomechanics of two types of bone-tendon-bone graft for ACL reconstruction. J Bone Joint Surg Br 77(2):232–235PubMed Liu SH, Kabo JM, Osti L (1995) Biomechanics of two types of bone-tendon-bone graft for ACL reconstruction. J Bone Joint Surg Br 77(2):232–235PubMed
19.
Zurück zum Zitat Marcacci M, Molgora AP, Zaffagnini S, Vascellari A, Iacono F, Presti ML (2003) Anatomic double-bundle anterior cruciate ligament reconstruction with hamstrings. Arthroscopy 19(5):540–546PubMedCrossRef Marcacci M, Molgora AP, Zaffagnini S, Vascellari A, Iacono F, Presti ML (2003) Anatomic double-bundle anterior cruciate ligament reconstruction with hamstrings. Arthroscopy 19(5):540–546PubMedCrossRef
20.
Zurück zum Zitat Muneta T, Koga H, Morito T, Yagishita K, Sekiya I (2006) A retrospective study of the midterm outcome of two-bundle anterior cruciate ligament reconstruction using quadrupled semitendinosus tendon in comparison with one-bundle reconstruction. Arthroscopy 22(3):252–258PubMedCrossRef Muneta T, Koga H, Morito T, Yagishita K, Sekiya I (2006) A retrospective study of the midterm outcome of two-bundle anterior cruciate ligament reconstruction using quadrupled semitendinosus tendon in comparison with one-bundle reconstruction. Arthroscopy 22(3):252–258PubMedCrossRef
21.
Zurück zum Zitat Petersen W, Zantop T (2007) Anatomy of the anterior cruciate ligament with regard to its two bundles. Clin Orthop Relat Res 454:35–47PubMedCrossRef Petersen W, Zantop T (2007) Anatomy of the anterior cruciate ligament with regard to its two bundles. Clin Orthop Relat Res 454:35–47PubMedCrossRef
22.
Zurück zum Zitat Petersen W, Zantop T (2009) Das vordere Kreuzband.Deutscher Ärzteverlag, Heidelberg Petersen W, Zantop T (2009) Das vordere Kreuzband.Deutscher Ärzteverlag, Heidelberg
23.
Zurück zum Zitat Shelbourne KD, Patel DV (1996) Rehabilitation after autogenous bone-patellar tendon-bone ACL reconstruction. Instr Course Lect 45:263–273PubMed Shelbourne KD, Patel DV (1996) Rehabilitation after autogenous bone-patellar tendon-bone ACL reconstruction. Instr Course Lect 45:263–273PubMed
24.
Zurück zum Zitat Siebold R, Dehler C, Ellert T (2008) Prospective randomized comparison of double-bundle versus single-bundle anterior cruciate ligament reconstruction. Arthroscopy 24(2):137–145PubMedCrossRef Siebold R, Dehler C, Ellert T (2008) Prospective randomized comparison of double-bundle versus single-bundle anterior cruciate ligament reconstruction. Arthroscopy 24(2):137–145PubMedCrossRef
25.
Zurück zum Zitat Singhatat W, Lawhorn KW, Howell SM, Hull ML (2002) How four weeks of implantation affect the strength and stiffness of a tendon graft in a bone tunnel: a study of two fixation devices in an extraarticular model in ovine. Am J Sports Med 30(4):506–513PubMed Singhatat W, Lawhorn KW, Howell SM, Hull ML (2002) How four weeks of implantation affect the strength and stiffness of a tendon graft in a bone tunnel: a study of two fixation devices in an extraarticular model in ovine. Am J Sports Med 30(4):506–513PubMed
26.
Zurück zum Zitat Strobel MJ, Zantop T (2010) Vorderes Kreuzband. Endopress, Tuttlingen Strobel MJ, Zantop T (2010) Vorderes Kreuzband. Endopress, Tuttlingen
27.
Zurück zum Zitat Weiler A, Peine R, Pashmineh-Azar A, Abel C, Sudkamp NP, Hoffmann RF (2002) Tendon healing in a bone tunnel. Part I: Biomechanical results after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep. Arthroscopy 18(2):113–123PubMedCrossRef Weiler A, Peine R, Pashmineh-Azar A, Abel C, Sudkamp NP, Hoffmann RF (2002) Tendon healing in a bone tunnel. Part I: Biomechanical results after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep. Arthroscopy 18(2):113–123PubMedCrossRef
28.
Zurück zum Zitat Yagi M, Kuroda R, Nagamune K, Yoshiya S, Kurosaka M (2007) Double-bundle ACL reconstruction can improve rotational stability. Clin Orthop Relat Res 454:100–107PubMedCrossRef Yagi M, Kuroda R, Nagamune K, Yoshiya S, Kurosaka M (2007) Double-bundle ACL reconstruction can improve rotational stability. Clin Orthop Relat Res 454:100–107PubMedCrossRef
29.
Zurück zum Zitat Yagi M, Wong EK, Kanamori A, Debski RE, Fu FH, Woo SL (2002) Biomechanical analysis of an anatomic anterior cruciate ligament reconstruction. Am J Sports Med 30(5):660–666PubMed Yagi M, Wong EK, Kanamori A, Debski RE, Fu FH, Woo SL (2002) Biomechanical analysis of an anatomic anterior cruciate ligament reconstruction. Am J Sports Med 30(5):660–666PubMed
30.
Zurück zum Zitat Yasuda K, Kondo E, Ichiyama H et al (2004) Anatomic reconstruction of the anteromedial and posterolateral bundles of the anterior cruciate ligament using hamstring tendon grafts. Arthroscopy 20(10):1015–1025PubMedCrossRef Yasuda K, Kondo E, Ichiyama H et al (2004) Anatomic reconstruction of the anteromedial and posterolateral bundles of the anterior cruciate ligament using hamstring tendon grafts. Arthroscopy 20(10):1015–1025PubMedCrossRef
31.
Zurück zum Zitat Yasuda K, Kondo E, Ichiyama H, Tanabe Y, Tohyama H (2006) Clinical evaluation of anatomic double-bundle anterior cruciate ligament reconstruction procedure using hamstring tendon grafts: comparisons among 3 different procedures. Arthroscopy 22(3):240–251PubMedCrossRef Yasuda K, Kondo E, Ichiyama H, Tanabe Y, Tohyama H (2006) Clinical evaluation of anatomic double-bundle anterior cruciate ligament reconstruction procedure using hamstring tendon grafts: comparisons among 3 different procedures. Arthroscopy 22(3):240–251PubMedCrossRef
32.
Zurück zum Zitat Zantop T, Kubo S, Petersen W, Musahl V, Fu FH (2007) Current techniques in anatomic anterior cruciate ligament reconstruction. Arthroscopy 23(9):938–947PubMedCrossRef Zantop T, Kubo S, Petersen W, Musahl V, Fu FH (2007) Current techniques in anatomic anterior cruciate ligament reconstruction. Arthroscopy 23(9):938–947PubMedCrossRef
33.
Zurück zum Zitat Zantop T, Petersen W, Sekiya JK, Musahl V, Fu FH (2006) Anterior cruciate ligament anatomy and function relating to anatomical reconstruction. Knee Surg Sports Traumatol Arthrosc 14(10):982–992PubMedCrossRef Zantop T, Petersen W, Sekiya JK, Musahl V, Fu FH (2006) Anterior cruciate ligament anatomy and function relating to anatomical reconstruction. Knee Surg Sports Traumatol Arthrosc 14(10):982–992PubMedCrossRef
34.
Zurück zum Zitat Zantop T, Weimann A, Schmidtko R, Herbort M, Raschke MJ, Petersen W (2006) Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d, l-lactide, and poly-d, l-lactide-tricalcium phosphate screws. Arthroscopy 22(11):1204–1210PubMedCrossRef Zantop T, Weimann A, Schmidtko R, Herbort M, Raschke MJ, Petersen W (2006) Graft laceration and pullout strength of soft-tissue anterior cruciate ligament reconstruction: in vitro study comparing titanium, poly-d, l-lactide, and poly-d, l-lactide-tricalcium phosphate screws. Arthroscopy 22(11):1204–1210PubMedCrossRef
Metadaten
Titel
Structural properties of a new fixation strategy in double bundle ACL reconstruction: the MiniShim
verfasst von
S. Lenschow
B. Schliemann
K. Dressler
B. Zampogna
S. Vasta
M. Raschke
T. Zantop
Publikationsdatum
01.08.2011
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 8/2011
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-011-1331-4

Weitere Artikel der Ausgabe 8/2011

Archives of Orthopaedic and Trauma Surgery 8/2011 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update Orthopädie und Unfallchirurgie