Purpose

The Freiburg Visual Acuity Test (FrACT) has been suggested as a promising test for quantifying the visual acuity (VA) of patients with very low vision, a condition often classified using the semi-quantitative clinical scale “counting fingers” (CF), “hand motion” (HM), “light perception” (LP) and “no light perception”. The present study was designed to assess FrACT performance in a sizable number of CF, HM, and LP patients in order to generate a setting for future clinical studies in the low vision range.

Methods

We examined a total of 41 patients (LP, n = 11; CF, n = 15; HM, n = 15) with various eye diseases (e.g., diabetic retinopathy, ARMD), covering the clinical VA scale from LP to CF. The FrACT optotypes were presented at a distance of 50 cm on a 17-inch LCD monitor with four random orientations. After training, two FrACT measurements (test and retest) were taken, each comprising 30 trials.

Results

FrACT measures reproducibly the VA of CF and HM patients. In CF patients, FrACT resulted in a mean logMAR = 1.98 ± 0.24 (corresponding to a decimal VA of 0.010), for HM in a mean logMAR = 2.28 ± 0.15 (corresponding to a decimal VA of 0.0052). In all LP patients the FrACT values were close to what would be obtained by random guessing. The mean test–retest 95% confidence interval was 0.21 logMAR for CF patients and 0.31 logMAR for HM respectively. Test-retest variability declined from 24 to 30 trials, showing that at least 30 trials are necessary.

Conclusion

FrACT can reproducibly quantify VA in the CF and HM range. We observed a floor effect for LP, and it was not quantifiable further. Quantitative VA measures are thus obtainable in the very low-vision range using FrACT.
Literatur
1.
Zurück zum Zitat Early Treatment Diabetic Retinopathy Study Group (1991) Early Treatment Diabetic Retinopathy Study design and baseline patient characteristics. ETDRS report number 7. Ophthalmology 98:741–756 Early Treatment Diabetic Retinopathy Study Group (1991) Early Treatment Diabetic Retinopathy Study design and baseline patient characteristics. ETDRS report number 7. Ophthalmology 98:741–756
2.
Zurück zum Zitat Arditi A, Cagenello R (1993) On the statistical reliability of letter-chart visual acuity measurements. Invest Ophthalmol Vis Sci 34:120–129PubMed Arditi A, Cagenello R (1993) On the statistical reliability of letter-chart visual acuity measurements. Invest Ophthalmol Vis Sci 34:120–129PubMed
7.
Zurück zum Zitat Beck RW, Moke PS, Turpin AH, Ferris FL 3rd, SanGiovanni JP, Johnson CA et al (2003) A computerized method of visual acuity testing: adaptation of the early treatment of diabetic retinopathy study testing protocol. Am J Ophthalmol 135:194–205, doi:10.1016/S0002-9394(02)01825-1 PubMedCrossRef Beck RW, Moke PS, Turpin AH, Ferris FL 3rd, SanGiovanni JP, Johnson CA et al (2003) A computerized method of visual acuity testing: adaptation of the early treatment of diabetic retinopathy study testing protocol. Am J Ophthalmol 135:194–205, doi:10.​1016/​S0002-9394(02)01825-1 PubMedCrossRef
8.
Zurück zum Zitat Colenbrander A (2002) Visual standards aspects and ranges of vision loss with emphasis on Population Surveys. Report prepared for the International Council of Ophthalmology at the 29th International Congress of Ophthalmology Sydney, Australia, April 2002 Colenbrander A (2002) Visual standards aspects and ranges of vision loss with emphasis on Population Surveys. Report prepared for the International Council of Ophthalmology at the 29th International Congress of Ophthalmology Sydney, Australia, April 2002
9.
Zurück zum Zitat Colenbrander A, Fletcher DC (1990) Visual acuity measurements in low vision patients. J Vis Rehab 4:1–9 Colenbrander A, Fletcher DC (1990) Visual acuity measurements in low vision patients. J Vis Rehab 4:1–9
11.
Zurück zum Zitat Ferris FL 3rd, Kassoff A, Bresnick GH, Bailey I (1982) New visual acuity charts for clinical research. Am J Ophthalmol 94:91–96PubMed Ferris FL 3rd, Kassoff A, Bresnick GH, Bailey I (1982) New visual acuity charts for clinical research. Am J Ophthalmol 94:91–96PubMed
12.
13.
Zurück zum Zitat Holladay JT (1997) Proper method for calculating average visual acuity. J Refract Surg 13:388–391PubMed Holladay JT (1997) Proper method for calculating average visual acuity. J Refract Surg 13:388–391PubMed
15.
Zurück zum Zitat Lieberman HR, Pentland AP (1982) Microcomputer-based estimation of psychophysical thresholds: The best PEST. Behav Res Meth Instrum 14:21–25 Lieberman HR, Pentland AP (1982) Microcomputer-based estimation of psychophysical thresholds: The best PEST. Behav Res Meth Instrum 14:21–25
17.
Zurück zum Zitat Schulze-Bonsel K, Feltgen N, Burau H, Hansen LL, Bach M (2006) Visual acuities “Hand Motion” and “Counting Fingers” can be quantified using the Freiburg Visual Acuity Test. Invest Ophthalmol Vis Sci 47:1236–1240, doi:10.1167/iovs.05-0981 PubMedCrossRef Schulze-Bonsel K, Feltgen N, Burau H, Hansen LL, Bach M (2006) Visual acuities “Hand Motion” and “Counting Fingers” can be quantified using the Freiburg Visual Acuity Test. Invest Ophthalmol Vis Sci 47:1236–1240, doi:10.​1167/​iovs.​05-0981 PubMedCrossRef
18.
Zurück zum Zitat Treutwein B (1995) Adaptive psychophysical procedures. Vision Res 35:2503–2522PubMed Treutwein B (1995) Adaptive psychophysical procedures. Vision Res 35:2503–2522PubMed
19.
Metadaten
Titel
Resolving the clinical acuity categories “hand motion” and “counting fingers” using the Freiburg Visual Acuity Test (FrACT)
verfasst von
C. Lange
N. Feltgen
B. Junker
K. Schulze-Bonsel
M. Bach
Publikationsdatum
01.01.2009
Verlag
Springer-Verlag
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology / Ausgabe 1/2009
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-008-0926-0

Weitere Artikel der Ausgabe 1/2009

Graefe's Archive for Clinical and Experimental Ophthalmology 1/2009 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Metastase in der periokulären Region

Metastasen Leitthema

Orbitale und periokuläre metastatische Tumoren galten früher als sehr selten. Aber mit der ständigen Aktualisierung von Medikamenten und Nachweismethoden für die Krebsbehandlung werden neue Chemotherapien und Strahlenbehandlungen eingesetzt. Die …

Staging und Systemtherapie bei okulären und periokulären Metastasen

Metastasen Leitthema

Metastasen bösartiger Erkrankungen sind die häufigsten Tumoren, die im Auge diagnostiziert werden. Sie treten bei ungefähr 5–10 % der Patienten mit soliden Tumoren im Verlauf der Erkrankung auf. Besonders häufig sind diese beim Mammakarzinom und …

Wundheilung nach Trabekulektomie

Trabekulektomie CME-Artikel

Die überschießende Wundheilung in der filtrierenden Glaukomchirurgie ist ein zentraler Faktor für ein operatives Versagen. Nach der Einführung der Trabekulektomie in den 1960er-Jahren wurden viele Faktoren erkannt, die mit einer vermehrten …

„standard operating procedures“ (SOP) – Vorschlag zum therapeutischen Management bei periokulären sowie intraokulären Metastasen

Metastasen Leitthema

Peri- sowie intraokuläre Metastasen sind insgesamt gesehen selten und meist Zeichen einer fortgeschrittenen primären Tumorerkrankung. Die Therapie ist daher zumeist palliativ und selten kurativ. Zudem ist die Therapiefindung sehr individuell. Die …

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.