Abstract

There are various surgical techniques for the treatment of spinal fractures in the thoracolumbar region. Several implants have been developed for anterior or posterior instrumentation. Optimal treatment of unstable thoracolumbar osseous and ligamentous injuries remains controversial. To compare the stabilizing effects of an antero-lateral, thoracoscopically implantable plate system (macsTL, Aesculap, Germany) with the stability provided by a fixateur interne (SOCON, Aesculap, Germany), this in vitro investigation examined six human bisegmental (T12–L2) spinal units. Specimens were tested intact, and with simulation of osseous lesions in the anterior and ligamentous lesions in the posterior column (combined A/B-fracture). While loaded in the main anatomical planes such as flexion/extension, left and right lateral bending and left and right axial rotation with a bending moment of 7.5 Nm in a special testing jigs, motion analysis was performed. Quantitative interpretation of the stabilizing effect was achieved using a contactless three-dimensional motion analysis system. Each specimen was tested in four different scenarios: the first step measured movements of intact spinal segments. For the second step, specimens underwent simulation of combined A/B-fracture provided with bisegmental (T12/L2) antero-lateral fixation and bone strut graft from the iliac crest. For the third step, segments were additionally stabilized by the fixateur interne. The last measurement (fourth step) was performed after removing the anterior instrumentation. Range of motion (ROM) values were compared and statistically evaluated. Compared to the intact specimens the anterior instrumentation of the combined lesion, simulated A/B-fracture, leads to a stabilizing effect in flexion/extension and lateral bending. In contrast to these findings the torsional instability increased for the upper segment and bisegmentally. A maximum rigidity, beyond intact values, was registered for each anatomical plane with the combined instrumentation: antero-lateral and fixateur interne. After removing the anterior screw plate system maximum movements, in all segments for flexion/extension and lateral bending, bisegmentally and for the upper segment in axial rotation, were less than ROM values measured with the anterior system only. With respect to these findings a combined ventro-dorsal stabilization procedure should be considered for ligamentous disruptions of the posterior column in combination with A-fractures in the thoracolumbar junction.
Literatur
1.
Zurück zum Zitat An HS, Lim TH, You JW, Hong JH, Eck J, McGrady L (1995) Biomechanical evaluation of anterior thoracolumbar spinal instrumentation. Spine 20:1979–1983PubMed An HS, Lim TH, You JW, Hong JH, Eck J, McGrady L (1995) Biomechanical evaluation of anterior thoracolumbar spinal instrumentation. Spine 20:1979–1983PubMed
2.
Zurück zum Zitat Been HD, Bouma GJ (1999) Comparison of two types of surgery for thoraco-lumbar burst fractures: combined anterior and posterior stabilisation vs. posterior instrumentation only. Acta Neurochir (Wien) 141:349–357CrossRef Been HD, Bouma GJ (1999) Comparison of two types of surgery for thoraco-lumbar burst fractures: combined anterior and posterior stabilisation vs. posterior instrumentation only. Acta Neurochir (Wien) 141:349–357CrossRef
3.
Zurück zum Zitat Beisse R, Potulski M, Bühren V (2001) Endoscopic techniques for the management of spinal trauma. Eur J Trauma 27:275–291 Beisse R, Potulski M, Bühren V (2001) Endoscopic techniques for the management of spinal trauma. Eur J Trauma 27:275–291
4.
Zurück zum Zitat Beisse R, Potulski M, Beger J, Bühren V (2002) Development and clinical application of a thoracoscopically implantable anterior plate for treatment of thoracolumbar fractures and instabilities. Orthopäde 31:413–422PubMedCrossRef Beisse R, Potulski M, Beger J, Bühren V (2002) Development and clinical application of a thoracoscopically implantable anterior plate for treatment of thoracolumbar fractures and instabilities. Orthopäde 31:413–422PubMedCrossRef
5.
Zurück zum Zitat Beisse R, Mückley T, Schmidt MH, Hauschild M, Bühren V (2005) Surgical technique and results of endoscopic anterior spinal canal decompression. J Neurosurg Spine 2:128–136PubMedCrossRef Beisse R, Mückley T, Schmidt MH, Hauschild M, Bühren V (2005) Surgical technique and results of endoscopic anterior spinal canal decompression. J Neurosurg Spine 2:128–136PubMedCrossRef
6.
Zurück zum Zitat Bozkus H, Chamberlain RH, Perez Garza LE, Crawford NR, Dickman CA (2004) Biomechanical comparison of anterolateral plate, lateral plate and pedicle screw-rods for enhancing anterolateral lumbar interbody cage stabilization. Spine 29:635–641PubMedCrossRef Bozkus H, Chamberlain RH, Perez Garza LE, Crawford NR, Dickman CA (2004) Biomechanical comparison of anterolateral plate, lateral plate and pedicle screw-rods for enhancing anterolateral lumbar interbody cage stabilization. Spine 29:635–641PubMedCrossRef
7.
Zurück zum Zitat Brodke DS, Gollogly S, Bachus KN, Mohr RA, Nguyen B-KN (2003) Anterior thoracolumbar instrumentation: stiffness and load sharing characteristics of plate and rod systems. Spine 28:1794–1801PubMedCrossRef Brodke DS, Gollogly S, Bachus KN, Mohr RA, Nguyen B-KN (2003) Anterior thoracolumbar instrumentation: stiffness and load sharing characteristics of plate and rod systems. Spine 28:1794–1801PubMedCrossRef
9.
Zurück zum Zitat Closhy JC, Akbarnia BA, Buchholz RD, Burkus JK, Backer RJ (1992) Neurologic recovery associated with anterior decompression of spine fractures at the thoracolumbar junction (T12-L1). Spine 17(Suppl 8):325S–330S Closhy JC, Akbarnia BA, Buchholz RD, Burkus JK, Backer RJ (1992) Neurologic recovery associated with anterior decompression of spine fractures at the thoracolumbar junction (T12-L1). Spine 17(Suppl 8):325S–330S
10.
Zurück zum Zitat Danisa OA, Shaffrey CI, Jane JA, Whitehill R, Wang G-J, Szabo TA, Hansen CA, Shaffrey ME, Chan DPK (1995) Surgical approaches for the correction of unstable thoracolumbar burst fractures: a retrospective analysis of treatment outcomes. J Neurosurg 83:977–983PubMedCrossRef Danisa OA, Shaffrey CI, Jane JA, Whitehill R, Wang G-J, Szabo TA, Hansen CA, Shaffrey ME, Chan DPK (1995) Surgical approaches for the correction of unstable thoracolumbar burst fractures: a retrospective analysis of treatment outcomes. J Neurosurg 83:977–983PubMedCrossRef
11.
Zurück zum Zitat Dick JC, Brodke DS, Zdeblick TA, Bartel BD, Kunz DN, Rapoff AJ (1997) Anterior instrumentation of the thoracolumbar spine. A biomechanical comparison. Spine 22:744–750PubMedCrossRef Dick JC, Brodke DS, Zdeblick TA, Bartel BD, Kunz DN, Rapoff AJ (1997) Anterior instrumentation of the thoracolumbar spine. A biomechanical comparison. Spine 22:744–750PubMedCrossRef
12.
Zurück zum Zitat Dickman CA, Yahiro MA, Lu HTC, Melkerson MN (1994) Surgical treatment alternatives for fixation of unstable fractures of the thoracic and lumbar spine. A meta analysis. Spine 19(Suppl 20):2266S–2273SPubMed Dickman CA, Yahiro MA, Lu HTC, Melkerson MN (1994) Surgical treatment alternatives for fixation of unstable fractures of the thoracic and lumbar spine. A meta analysis. Spine 19(Suppl 20):2266S–2273SPubMed
13.
Zurück zum Zitat Ferguson RL, Tencer AF, Woodward P, Allen BL Jr (1988) Biomechanical comparison of spinal fracture models and the stabilizing effects of posterior instrumentations. Spine 13:453–460PubMedCrossRef Ferguson RL, Tencer AF, Woodward P, Allen BL Jr (1988) Biomechanical comparison of spinal fracture models and the stabilizing effects of posterior instrumentations. Spine 13:453–460PubMedCrossRef
14.
Zurück zum Zitat Flamme CH, Hurschler C, Heymann C, von der Heide N (2005) Comparative biomechanical testing of anterior and posterior stabilization procedures. Spine 30:E352-E362PubMedCrossRef Flamme CH, Hurschler C, Heymann C, von der Heide N (2005) Comparative biomechanical testing of anterior and posterior stabilization procedures. Spine 30:E352-E362PubMedCrossRef
15.
Zurück zum Zitat Fredrickson BE, Edwards WT, Rauschning W, Bayley JC, Yuan HA (1992) Volvo award in experimental studies. Vertebral burst fractures an experimental, morphologic, and radiographic study. Spine 17:1012–1021PubMedCrossRef Fredrickson BE, Edwards WT, Rauschning W, Bayley JC, Yuan HA (1992) Volvo award in experimental studies. Vertebral burst fractures an experimental, morphologic, and radiographic study. Spine 17:1012–1021PubMedCrossRef
16.
Zurück zum Zitat Ghanayem AJ, Zdeblick TA (1997) Anterior instrumentation in the management of thoracolumbar burst fractures. Clin Orthop 335:89–100PubMed Ghanayem AJ, Zdeblick TA (1997) Anterior instrumentation in the management of thoracolumbar burst fractures. Clin Orthop 335:89–100PubMed
17.
Zurück zum Zitat Haas N, Blauth M, Tscherne H (1991) Anterior plating in thoracolumbar spine injuries. Indication, technique and results. Spine 16(Suppl 3):100S–111S Haas N, Blauth M, Tscherne H (1991) Anterior plating in thoracolumbar spine injuries. Indication, technique and results. Spine 16(Suppl 3):100S–111S
18.
Zurück zum Zitat Kaneda K, Taneichi H, Abumi K, Hashimoto T, Satoh S, Fujiya M (1997) Anterior decompression and stabilization with the Kaneda device for thoracolumbar burst fractures associated with neurological deficits. J Bone Joint Surg [Am] 79:69–83 Kaneda K, Taneichi H, Abumi K, Hashimoto T, Satoh S, Fujiya M (1997) Anterior decompression and stabilization with the Kaneda device for thoracolumbar burst fractures associated with neurological deficits. J Bone Joint Surg [Am] 79:69–83
19.
Zurück zum Zitat Knop C, Blauth M, Bastian L, Lange U, Kesting J, Tscherne H (1997) Fractures of the thoracolumbar spine. Late results and consequences of dorsal instrumentation. Unfallchirurg 100:630–639PubMedCrossRef Knop C, Blauth M, Bastian L, Lange U, Kesting J, Tscherne H (1997) Fractures of the thoracolumbar spine. Late results and consequences of dorsal instrumentation. Unfallchirurg 100:630–639PubMedCrossRef
20.
Zurück zum Zitat Kostuik JP (1988) Anterior fixation for burst fractures of the thoracic and lumbar spine with or without neurological involvement. Spine 13:286–293PubMedCrossRef Kostuik JP (1988) Anterior fixation for burst fractures of the thoracic and lumbar spine with or without neurological involvement. Spine 13:286–293PubMedCrossRef
21.
Zurück zum Zitat Krag MH (1991) Biomechanics of thoracolumbar spinal fixation. A review. Spine 16(3 Suppl):84–99CrossRef Krag MH (1991) Biomechanics of thoracolumbar spinal fixation. A review. Spine 16(3 Suppl):84–99CrossRef
22.
Zurück zum Zitat Lim TH, An HS, Hong JH, Ahn JY, You JW, Eck J, McGrady LM (1997) Biomechanical evaluation of anterior and posterior fixations in an unstable calf spine model. Spine 22:261–266PubMedCrossRef Lim TH, An HS, Hong JH, Ahn JY, You JW, Eck J, McGrady LM (1997) Biomechanical evaluation of anterior and posterior fixations in an unstable calf spine model. Spine 22:261–266PubMedCrossRef
23.
Zurück zum Zitat Magerl F, Aebi M, Gertzbein D, Harms J, Nazarian S (1994) A comprehensive classification of thoracic and lumbar injuries. Eur Spine J 3:184–201PubMedCrossRef Magerl F, Aebi M, Gertzbein D, Harms J, Nazarian S (1994) A comprehensive classification of thoracic and lumbar injuries. Eur Spine J 3:184–201PubMedCrossRef
24.
Zurück zum Zitat Mann KA, McGowan DP, Frdrickson BE, Falahee M, Yuan HA (1990) A biomechanical investigation of short segment spinal fixation for burst fractures with varying degrees of posterior disruption. Spine 15:470–478PubMedCrossRef Mann KA, McGowan DP, Frdrickson BE, Falahee M, Yuan HA (1990) A biomechanical investigation of short segment spinal fixation for burst fractures with varying degrees of posterior disruption. Spine 15:470–478PubMedCrossRef
25.
Zurück zum Zitat McAfee PC (1994) Complications of anterior approaches to the thoracolumbar spine. Emphasis on Kaneda instrumentation. Clin Orthop 306:110–119PubMed McAfee PC (1994) Complications of anterior approaches to the thoracolumbar spine. Emphasis on Kaneda instrumentation. Clin Orthop 306:110–119PubMed
26.
Zurück zum Zitat Oertel J, Niendorf W-R, Darwish N, Schroeder HWS, Gaab MR (2004) Limitations of dorsal transpedicular stabilization in unstable fractures of the lower thoracic and lumbar spine: an analysis of 133 patients. Acta Neurochir Wien 146:771–777PubMed Oertel J, Niendorf W-R, Darwish N, Schroeder HWS, Gaab MR (2004) Limitations of dorsal transpedicular stabilization in unstable fractures of the lower thoracic and lumbar spine: an analysis of 133 patients. Acta Neurochir Wien 146:771–777PubMed
27.
Zurück zum Zitat Potulski M, Beisse R, Bühren V (1999) Thoracoscopy-guided management of the “anterior column”. Methods and results. Orthopäde 28:723–730PubMed Potulski M, Beisse R, Bühren V (1999) Thoracoscopy-guided management of the “anterior column”. Methods and results. Orthopäde 28:723–730PubMed
28.
Zurück zum Zitat Rohlmann A, Zander T, Bergmann G (2005) Comparison of the biomechanical effects of posterior and anterior spine-stabilizing implants. Eur Spine J 14:445–453PubMedCrossRef Rohlmann A, Zander T, Bergmann G (2005) Comparison of the biomechanical effects of posterior and anterior spine-stabilizing implants. Eur Spine J 14:445–453PubMedCrossRef
29.
Zurück zum Zitat Sasso RC, Best NM, Reilly TM, McGuire RA Jr (2005) Anterior-only stabilization of three column thoracolumbar injuries. J Spinal Disord Tech 18(Suppl 1):S7–S14PubMedCrossRef Sasso RC, Best NM, Reilly TM, McGuire RA Jr (2005) Anterior-only stabilization of three column thoracolumbar injuries. J Spinal Disord Tech 18(Suppl 1):S7–S14PubMedCrossRef
30.
Zurück zum Zitat Schreiber U, Bence T, Bader R, Beisse R, Grupp T, Mittelmeier W, Steinhauser E (2001) Validation of a newly developed experimental setup for segmental spinal testing. J Biomech 34(Suppl):65–66 Schreiber U, Bence T, Bader R, Beisse R, Grupp T, Mittelmeier W, Steinhauser E (2001) Validation of a newly developed experimental setup for segmental spinal testing. J Biomech 34(Suppl):65–66
31.
Zurück zum Zitat Schreiber U, Bence T, Grupp T, Steinhauser E, Mückley T, Mittelmeier W, Beisse R (2005) Is a single antero lateral screw-plate fixation for the treatment of spinal fractures in the thoracolumbar junction sufficient? A biomechanical in vitro investigation. Eur Spine J 14:197–204PubMedCrossRef Schreiber U, Bence T, Grupp T, Steinhauser E, Mückley T, Mittelmeier W, Beisse R (2005) Is a single antero lateral screw-plate fixation for the treatment of spinal fractures in the thoracolumbar junction sufficient? A biomechanical in vitro investigation. Eur Spine J 14:197–204PubMedCrossRef
32.
Zurück zum Zitat Schultheiss M, Hartwig E, Kinzl L, Claes L, Wilke HJ (2004) Thoracolumbar fracture stabilization: comparative biomechanical evaluation of a new video-assisted implantable system. Eur Spine J 13:93–100PubMedCrossRef Schultheiss M, Hartwig E, Kinzl L, Claes L, Wilke HJ (2004) Thoracolumbar fracture stabilization: comparative biomechanical evaluation of a new video-assisted implantable system. Eur Spine J 13:93–100PubMedCrossRef
33.
Zurück zum Zitat Slosar PJ, Patwardhan AG, Lorenz M, Havey R, Sartori M (1995) Instability of the lumbar burst fracture and limitations of transpedicular instrumentation. Spine 20:1452–1461PubMedCrossRef Slosar PJ, Patwardhan AG, Lorenz M, Havey R, Sartori M (1995) Instability of the lumbar burst fracture and limitations of transpedicular instrumentation. Spine 20:1452–1461PubMedCrossRef
34.
Zurück zum Zitat Wilke HJ, Wenger K, Claes LE (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of the spinal implants. Eur Spine J 7:148–154PubMedCrossRef Wilke HJ, Wenger K, Claes LE (1998) Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of the spinal implants. Eur Spine J 7:148–154PubMedCrossRef
35.
Zurück zum Zitat Wilke HJ, Kemmerich V, Claes LE, Arand M (2001) Combined anteroposterior spinal fixation provides superior stabilisation to a single anterior or posterior procedure. J Bone Joint Surg [Br] 83:609–617CrossRef Wilke HJ, Kemmerich V, Claes LE, Arand M (2001) Combined anteroposterior spinal fixation provides superior stabilisation to a single anterior or posterior procedure. J Bone Joint Surg [Br] 83:609–617CrossRef
36.
Zurück zum Zitat Wood GW 2nd, Boyd RJ, Carothers TA, Mansfield FL, Rechtine GL, Rozen MJ, Sutterlin CE 3rd (1995) The effect of pedicle screw/plate fixation on lumbar/lumbosacral autogenous bone graft fusions in patients with degenerative disc disease. Spine 20:819–830PubMedCrossRef Wood GW 2nd, Boyd RJ, Carothers TA, Mansfield FL, Rechtine GL, Rozen MJ, Sutterlin CE 3rd (1995) The effect of pedicle screw/plate fixation on lumbar/lumbosacral autogenous bone graft fusions in patients with degenerative disc disease. Spine 20:819–830PubMedCrossRef
37.
Zurück zum Zitat Wood KB, Bohn D, Mehbod A (2005) Anterior versus posterior treatment of stable thoracolumbar burst fractures without neurologic deficit. A prospective, randomized study. J Spinal Disord Tech 18(Suppl 1):S15–S23PubMedCrossRef Wood KB, Bohn D, Mehbod A (2005) Anterior versus posterior treatment of stable thoracolumbar burst fractures without neurologic deficit. A prospective, randomized study. J Spinal Disord Tech 18(Suppl 1):S15–S23PubMedCrossRef
Metadaten
Titel
Two column lesions in the thoracolumbar junction: anterior, posterior or combined approach? A comparative biomechanical in vitro investigation
verfasst von
Tibor Bence
Ulrich Schreiber
Thomas Grupp
Erwin Steinhauser
Wolfram Mittelmeier
Publikationsdatum
01.06.2007
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 6/2007
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-006-0201-1

Weitere Artikel der Ausgabe 6/2007

European Spine Journal 6/2007 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Lever-Sign-Test hilft beim Verdacht auf Kreuzbandriss

15.05.2024 Vordere Kreuzbandruptur Nachrichten

Mit dem Hebelzeichen-Test lässt sich offenbar recht zuverlässig feststellen, ob ein vorderes Kreuzband gerissen ist. In einer Metaanalyse war die Vorhersagekraft vor allem bei positivem Testergebnis hoch.

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.