Orthodontic Study Cast Analysis—Reproducibility of Recordings and Agreement Between Conventional and 3D Virtual Measurements

verfasst von: Anders P. G. Sjögren, Jan E. Lindgren, Jan Å. V. Huggare

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 4/2010

Einloggen, um Zugang zu erhalten

Abstract

Digital imaging of dental casts has become an alternative to conventional cast analysis in orthodontic treatment planning. The reproducibility of angular measurements made on virtual digital models has not as yet been evaluated. In order to study reproducibility for and agreement between a conventional analysis technique and virtual 3D imaging, 20 dental casts from subjects in the early mixed dentition, were measured twice with each technique by two orthodontists. Variables of interest were incisor rotation, angulation and irregularity, arch width, arch circumference, overjet, and overbite. Standard deviation (Dahlberg 1940) and coefficient of variation were used for evaluation of reproducibility. Mean differences between methods and examiners, correlation between mean differences and mean levels and 95% limits of agreement were used for describing systematic errors. The conventional technique showed less intraexaminer variation for angular variables than the 3D imaging method. Linear variables, with the exception of overbite, showed no clear trend as regards differences in reproducibility between the two methods. In general, examiner 1 showed less intraexaminer variation than examiner 2. The mean differences between the two methods expressed higher values for assessment of rotations with the O3DM method. Both angular and linear variables exhibited poor 95% limits of agreement. The conventional technique showed better overall reproducibility and thus appears to be more suitable for scientific work. However, the reproducibility attained by O3DM is clearly acceptable for clinical use. The two methods should not be used interchangeably.
Literatur
1.
Zurück zum Zitat Dahlberg G: Statistical Methods for Medical and Biological Students. London: George Allen & Unwin Ltd, 1940, pp 122–132 Dahlberg G: Statistical Methods for Medical and Biological Students. London: George Allen & Unwin Ltd, 1940, pp 122–132
2.
Zurück zum Zitat Edwards JG: A long-term prospective evaluation of the circumferential supracrestal fiberotomy in alleviating orthodontic relapse. Am J Orthod Dentofacial Orthop 93:380–387, 1988CrossRefPubMed Edwards JG: A long-term prospective evaluation of the circumferential supracrestal fiberotomy in alleviating orthodontic relapse. Am J Orthod Dentofacial Orthop 93:380–387, 1988CrossRefPubMed
3.
Zurück zum Zitat Reitan K: Tissue rearrangement during the retention of orthodontically rotated teeth. Angle Orthod 29:105–113, 1959 Reitan K: Tissue rearrangement during the retention of orthodontically rotated teeth. Angle Orthod 29:105–113, 1959
4.
Zurück zum Zitat Surbeck B, Årtun J: Associations between initial, posttreatment and postretention alignment of maxillary anterior teeth. Am J Orthod 113(2):186–195, 1998 Surbeck B, Årtun J: Associations between initial, posttreatment and postretention alignment of maxillary anterior teeth. Am J Orthod 113(2):186–195, 1998
5.
Zurück zum Zitat Little RM: The irregularity index: a quantitative score of mandibular anterior alignment. Am J Orthod 68:554–563, 1975CrossRefPubMed Little RM: The irregularity index: a quantitative score of mandibular anterior alignment. Am J Orthod 68:554–563, 1975CrossRefPubMed
6.
Zurück zum Zitat Naraghi S, Andren A, Kjellberg H, Mohlin BO: Relapse tendency after orthodontic correction of upper front teeth retained with a bonded retainer. Angle Orthod 76:570–576, 2006PubMed Naraghi S, Andren A, Kjellberg H, Mohlin BO: Relapse tendency after orthodontic correction of upper front teeth retained with a bonded retainer. Angle Orthod 76:570–576, 2006PubMed
7.
Zurück zum Zitat Little RM, Riedel RA, Artun J: An evaluation of changes in mandibular anterior alignment from 10 to 20 years postretention. Am J Orthod Dentofacial Orthop 93:423–428, 1988CrossRefPubMed Little RM, Riedel RA, Artun J: An evaluation of changes in mandibular anterior alignment from 10 to 20 years postretention. Am J Orthod Dentofacial Orthop 93:423–428, 1988CrossRefPubMed
8.
Zurück zum Zitat Gracco A, Buranello M, Cozzani M, Siciliani G: Digital and plaster models: a comparison of measurements and times. Prog Orthod 8:252–259, 2007PubMed Gracco A, Buranello M, Cozzani M, Siciliani G: Digital and plaster models: a comparison of measurements and times. Prog Orthod 8:252–259, 2007PubMed
9.
Zurück zum Zitat Quimby ML, Vig KW, Rashid RG, Firestone AR: The accuracy and reliability of measurements made on computer-based digital models. Angle Orthod 74:298–303, 2004PubMed Quimby ML, Vig KW, Rashid RG, Firestone AR: The accuracy and reliability of measurements made on computer-based digital models. Angle Orthod 74:298–303, 2004PubMed
10.
Zurück zum Zitat Zilberman O, Huggare JA, Parikakis KA: Evaluation of the validity of tooth size and arch width measurements using conventional and three-dimensional virtual orthodontic models. Angle Orthod 73:301–306, 2003PubMed Zilberman O, Huggare JA, Parikakis KA: Evaluation of the validity of tooth size and arch width measurements using conventional and three-dimensional virtual orthodontic models. Angle Orthod 73:301–306, 2003PubMed
11.
Zurück zum Zitat Asquith J, Gillgrass T, Mossey P: Three-dimensional imaging of orthodontic models: a pilot study. Eur J Orthod 29:517–522, 2007CrossRefPubMed Asquith J, Gillgrass T, Mossey P: Three-dimensional imaging of orthodontic models: a pilot study. Eur J Orthod 29:517–522, 2007CrossRefPubMed
12.
Zurück zum Zitat Hildebrand JC, Palomo JM, Palomo L, Sivik M, Hans M: Evaluation of a software program for applying the American Board of Orthodontics objective grading system to digital casts. Am J Orthod Dentofacial Orthop 133:283–289, 2008CrossRefPubMed Hildebrand JC, Palomo JM, Palomo L, Sivik M, Hans M: Evaluation of a software program for applying the American Board of Orthodontics objective grading system to digital casts. Am J Orthod Dentofacial Orthop 133:283–289, 2008CrossRefPubMed
13.
Zurück zum Zitat Mok CW, Zhou L, McGrath C, Hagg U, Bendeus M: Digital images as an alternative to orthodontic casts in assessing malocclusion and orthodontic treatment need. Acta Odontol Scand 65:362–368, 2007CrossRefPubMed Mok CW, Zhou L, McGrath C, Hagg U, Bendeus M: Digital images as an alternative to orthodontic casts in assessing malocclusion and orthodontic treatment need. Acta Odontol Scand 65:362–368, 2007CrossRefPubMed
14.
Zurück zum Zitat Okunami TR, Kusnoto B, BeGole E, Evans CA, Sadowsky C, Fadavi S: Assessing the American Board of Orthodontics objective grading system: digital vs plaster dental casts. Am J Orthod Dentofacial Orthop 131:51–56, 2007CrossRefPubMed Okunami TR, Kusnoto B, BeGole E, Evans CA, Sadowsky C, Fadavi S: Assessing the American Board of Orthodontics objective grading system: digital vs plaster dental casts. Am J Orthod Dentofacial Orthop 131:51–56, 2007CrossRefPubMed
15.
Zurück zum Zitat Stevens DR, Flores-Mir C, Nebbe B, Raboud DW, Heo G, Major PW: Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurements. Am J Orthod Dentofacial Orthop 129:794–803, 2006CrossRefPubMed Stevens DR, Flores-Mir C, Nebbe B, Raboud DW, Heo G, Major PW: Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurements. Am J Orthod Dentofacial Orthop 129:794–803, 2006CrossRefPubMed
16.
Zurück zum Zitat Costalos PA, Sarraf K, Cangialosi TJ, Efstratiadis S: Evaluation of the accuracy of digital model analysis for the American Board of Orthodontics objective grading system for dental casts. Am J Orthod Dentofacial Orthop 128:624–629, 2005CrossRefPubMed Costalos PA, Sarraf K, Cangialosi TJ, Efstratiadis S: Evaluation of the accuracy of digital model analysis for the American Board of Orthodontics objective grading system for dental casts. Am J Orthod Dentofacial Orthop 128:624–629, 2005CrossRefPubMed
17.
Zurück zum Zitat Mullen SR, Martin CA, Ngan P, Gladwin M: Accuracy of space analysis with emodels and plaster models. Am J Orthod Dentofacial Orthop 132:346–352, 2007CrossRefPubMed Mullen SR, Martin CA, Ngan P, Gladwin M: Accuracy of space analysis with emodels and plaster models. Am J Orthod Dentofacial Orthop 132:346–352, 2007CrossRefPubMed
18.
Zurück zum Zitat Santoro M, Galkin S, Teredesai M, Nicolay OF, Cangialosi TJ: Comparison of measurements made on digital and plaster models. Am J Orthod Dentofacial Orthop 124:101–105, 2003CrossRefPubMed Santoro M, Galkin S, Teredesai M, Nicolay OF, Cangialosi TJ: Comparison of measurements made on digital and plaster models. Am J Orthod Dentofacial Orthop 124:101–105, 2003CrossRefPubMed
19.
Zurück zum Zitat Tomassetti JJ, Taloumis LJ, Denny JM, Fischer Jr., JR: A comparison of 3 computerized Bolton tooth-size analyses with a commonly used method. Angle Orthod 71:351–357, 2001PubMed Tomassetti JJ, Taloumis LJ, Denny JM, Fischer Jr., JR: A comparison of 3 computerized Bolton tooth-size analyses with a commonly used method. Angle Orthod 71:351–357, 2001PubMed
20.
Zurück zum Zitat Bland M: An Introduction to Medical Statistics, Oxford: Oxford University Press, 1991 Bland M: An Introduction to Medical Statistics, Oxford: Oxford University Press, 1991
21.
Zurück zum Zitat Altman DG: Practical Statistics for Medical Research, UK: Chapman & Hall/CRC, 1999 Altman DG: Practical Statistics for Medical Research, UK: Chapman & Hall/CRC, 1999
Metadaten
Titel
Orthodontic Study Cast Analysis—Reproducibility of Recordings and Agreement Between Conventional and 3D Virtual Measurements
verfasst von
Anders P. G. Sjögren
Jan E. Lindgren
Jan Å. V. Huggare
Publikationsdatum
01.08.2010
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 4/2010
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-009-9211-y

Weitere Artikel der Ausgabe 4/2010

Journal of Digital Imaging 4/2010 Zur Ausgabe

EditorialNotes

The Magical iPad

Akuter Schwindel: Wann lohnt sich eine MRT?

28.04.2024 Schwindel Nachrichten

Akuter Schwindel stellt oft eine diagnostische Herausforderung dar. Wie nützlich dabei eine MRT ist, hat eine Studie aus Finnland untersucht. Immerhin einer von sechs Patienten wurde mit akutem ischämischem Schlaganfall diagnostiziert.

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

S3-Leitlinie zu Pankreaskrebs aktualisiert

23.04.2024 Pankreaskarzinom Nachrichten

Die Empfehlungen zur Therapie des Pankreaskarzinoms wurden um zwei Off-Label-Anwendungen erweitert. Und auch im Bereich der Früherkennung gibt es Aktualisierungen.

Fünf Dinge, die im Kindernotfall besser zu unterlassen sind

18.04.2024 Pädiatrische Notfallmedizin Nachrichten

Im Choosing-Wisely-Programm, das für die deutsche Initiative „Klug entscheiden“ Pate gestanden hat, sind erstmals Empfehlungen zum Umgang mit Notfällen von Kindern erschienen. Fünf Dinge gilt es demnach zu vermeiden.

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.