Abstract
The force imparted by removable thermoplastic appliances (RTA) onto teeth has not been investigated in the past. This investigation was designed to explore a novel methodology to measure the magnitude and identify the pattern of this force. Eight patients with moderate malocclusion were selected. In each patient, the palatally mal-positioned upper first premolar was corrected by wearing a series of four ClearSmile® RTA over a duration of 8 weeks. When constructing RTA, the ClearSmile® Company was advised that the amount of movement to be programmed into each appliance was 0.5 mm. The Pressurex® film was used to measure the pressure generated by ClearSmile® RTA against the palatal surface of the upper first premolar for buccal tipping movement. Three measurements were conducted respectively upon the issue and retrieval of each appliance (after 2 weeks of wear), resulting in 24 pressure measurements for each patient. Digital imaging and spectrophotometry analysis were employed to quantify the stain intensity mounted by the pressure on the films. The irrelevant forces were subtracted out to allow an assessment of the force purely acting to buccally repositioning the tooth. The results revealed that (1) the mean force magnitude over 2 weeks of RTA wear was 1.12 N (SE = 0.72 N); (2) the higher force magnitude of 5.12 N (SE = 0.80 N) seen at the issue of the appliance declined drastically to −2.67 N at the time of retrieval. These findings suggest that ClearSmile® RTA exerts a high level of force against the tooth to be moved at the initial stage followed by a rapid force diminish.
Similar content being viewed by others
References
Celi A., Merrill-Skoloff G., Gross P., Falati S., Sim D. S., Flaumenhaft R., Furie B. C., Furie B. Thrombus formation: direct real-time observation and digital analysis of thrombus assembly in a living mouse by confocal and widefield intravital microscopy. J. Thromb. Haemost. 1:60–68, 2003
Djeu G., Shelton C., A. Maganzini. Outcome assessment of Invisalign and traditional orthodontic treatment compared with the American Board of Orthodontics objective grading system. Am. J. Orthod. Dentofacial Orthop. 128:292–298; discussion 298, 2005
Dorow C., Krstin N., Sander F. G. Experimental model of tooth mobility in the human “in vivo”. Biomed. Tech. (Berl.) 47:20–25, 2002
Eliades T., Eliades G., D. C. Watts. Structural conformation of in vitro and in vivo aged orthodontic elastomeric modules. Eur. J. Orthod. 21:649–658, 1999
Hale J. E., T. D. Brown. Contact stress gradient detection limits of Pressensor film. J. Biomech. Eng. 114:352–357, 1992
Hori K., Ono T., Iwata H., Nokubi T., I. Kumakura. Tongue pressure against hard palate during swallowing in post-stroke patients. Gerodontology 22:227–233, 2005
Huget E. F., Patrick K. S., L. J. Nunez. Observations on the elastic behavior of a synthetic orthodontic elastomer. J. Dent. Res. 69:496–501, 1990
Kesling H. D. The philosophy of the tooth positioning appliance. Am. J. Orthod. Oral Surg. 31:297–304, 1945
Liggins A. B. The practical application of Fuji Prescale pressure-sensitive film. In: Optical Measurement Methods in Biomechanics, edited by Orr J. F., Shelton J. C. London: Chapman and Hall; 1997, pp. 173–186
Liggins A. B., J. B. Finlay. Image-averaging in the analysis of data from Fiji pressure-sensitive film. Exp. Technique 21:19–22, 1997
Liggins A. B., Hardie W. R., Finlay J. B. The spatial and pressure resolution of Fuji pressure-sensitive film. Exp. Mech. 35:166–173, 1995
Liggin A. B., Surry K., J. B. Finlay. Sealing Fuji prescale pressure-sensitive film for protection against fluid damage: the effects on its response. Strain 31:57–62, 1995
Liu Z. J., Herring S. W. Bone surface strains and internal bony pressures at the jaw joint of the miniature pig during masticatory muscle contraction. Arch Oral Biol. 45:95–112, 2000
Nakagami G., Sanada H., Konya C., Kitagawa A., Tadaka E., Tabata K. Comparison of two pressure ulcer preventive dressings for reducing shear force on the heel. J. Wound Ostomy Continence Nurs. 33:267–272, 2006
Robinson J. W. Spectrophotometry, colorimetry and polarimetry. In: Undergraduate Instrumental Analysis, edited by Robinson J. W. New York: Marcel Dekker Inc, 1995, pp. 386–403
Schuster S., Eliades G., Zinelis S., Eliades T., T. G. Bradley. Structural conformation and leaching from in vitro aged and retrieved Invisalign appliances. Am. J. Orthod. Dentofacal Orthop. 126:725–728, 2004
Sheridan J. J. The Readers’ Corner. 2. What percentage of your patients are being treated with Invisalign appliances? J. Clin. Orthod. 38:544–545, 2004
Shrive N. G. Soft tissue strain measurement. In: Optical Measurement Methods in Biomechanics, edited by Orr J. F., Shelton J. C. London: Champman and Hall, 1997, pp. 154–159
Venugopal K., R. N. Saha. New, simple and validated UV-spectrophotometric methods for the estimation of gatifloxacin in bulk and formulations. Farmaco. 60:906–912, 2005
Yip S. K., Pang M. W., Sahota D. S. Measurement of tension-free vaginal tape trocar insertion and exit forces. Gynecol. Obstet. Invest. 62: 55–60, 2006
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Barbagallo, L.J., Shen, G., Jones, A.S. et al. A Novel Pressure Film Approach for Determining the Force Imparted by Clear Removable Thermoplastic Appliances. Ann Biomed Eng 36, 335–341 (2008). https://doi.org/10.1007/s10439-007-9424-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10439-007-9424-5