Skip to main content
Erschienen in: Archives of Orthopaedic and Trauma Surgery 2/2007

01.02.2007 | Orthopaedic Surgery

Posterior stability in fixed-bearing versus mobile-bearing total knee replacement: a radiological comparison of two implants

verfasst von: R. Siebold, S. Louisia, J. Canty, R. J. Bartlett

Erschienen in: Archives of Orthopaedic and Trauma Surgery | Ausgabe 2/2007

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Posterior tibial translation in total knee replacement (TKR) could be one major factor for PE wear, delamination and loosening of the tibial component due to increased shear forces and component-to-bone interface stress. The aim of this study was to assess the posterior stability of two different designs of posterior cruciate ligament (PCL) substituting TKR.

Method

In this non-randomised consecutive study 43 patients underwent TKR for primary osteoarthritis. Twenty-six patients in group FB received a deep-dished fixed-bearing Duracon TKR (Howmedica, Rutherford, NJ, USA) and 17 patients in group MB a deep-dished rotating mobile-bearing Duracon TKR. In both groups the PCL was resected. All patients had pre- and postoperative kneeling stress radiographs and were clinically evaluated with the Knee Society Score. Posterior tibial translation was measured by tracing a line along the posterior tibial cortex in relationship to the posterior edge of Blumensaat’s line.

Results

The average follow-up was 13 months for group FB and 11 months for group MB. Both groups demonstrated a statistical significant increase of the mean posterior tibial translation on kneeling stress X-ray of 4.1 mm (group FB) (P < 0.001) and of 6.6 mm (group MB) (P < 0.001) compared to pre-operative. Group MB showed a significant higher posterior draw (P < 0.008). Clinical assessment using the Knee Society Score showed comparable short-term results.

Conclusion

The deep-dished fixed-bearing TKR as well as the deep-dished rotating mobile-bearing TKR demonstrated significant posterior tibial translation on kneeling stress X-ray. It remains to be determined what amount of joint play is optimal for clinical function and to minimise shear forces and PE wear. Moreover the amount of posterior tibial translation was significantly higher with the mobile-bearing insert, which could be directly related to the asymmetric rotational mobility of the tibial insert. A long-term follow-up is necessary to investigate whether our findings correlate with the survival-rate of these specific implants.
Literatur
1.
Zurück zum Zitat Andriacchi TP, Galante JO, Fermier RW (1982) The influence of total knee replacement design on walking and stair-climbing. J Bone Joint Surg Am 64:1328PubMed Andriacchi TP, Galante JO, Fermier RW (1982) The influence of total knee replacement design on walking and stair-climbing. J Bone Joint Surg Am 64:1328PubMed
2.
Zurück zum Zitat Bartlett J, Osti L, Porteous A (2003) Stress radiography for documentation of posterior instability of the knee. Presented on ISAKOS Congress 2003, Auckland Bartlett J, Osti L, Porteous A (2003) Stress radiography for documentation of posterior instability of the knee. Presented on ISAKOS Congress 2003, Auckland
3.
Zurück zum Zitat Bert JM (1990) Dislocation/subluxation of meniscal bearing elements after New Jersey Low-Contact-Stress total knee arthroplasty. Clin Orthop 254:211–215PubMed Bert JM (1990) Dislocation/subluxation of meniscal bearing elements after New Jersey Low-Contact-Stress total knee arthroplasty. Clin Orthop 254:211–215PubMed
4.
Zurück zum Zitat Buechel FF, Pappas MJ (1990) Long-term survivorship analysis of cruciate-bearing versus cruciate-sacrificing knee prosthesis using meniscal bearing. Clin Orthop 260:162–169PubMed Buechel FF, Pappas MJ (1990) Long-term survivorship analysis of cruciate-bearing versus cruciate-sacrificing knee prosthesis using meniscal bearing. Clin Orthop 260:162–169PubMed
5.
Zurück zum Zitat Callaghan JJ, Insall JN, Greenwald AS, Dennis DA, Komistek RD, Murray DW, Bourne RB, Rorabeck CH, Dorr LD (2000) Mobile-Bearing knee replacement:conceps and results. J Bone Joint Surg 82A:1020–1041 Callaghan JJ, Insall JN, Greenwald AS, Dennis DA, Komistek RD, Murray DW, Bourne RB, Rorabeck CH, Dorr LD (2000) Mobile-Bearing knee replacement:conceps and results. J Bone Joint Surg 82A:1020–1041
6.
7.
Zurück zum Zitat Dejour D, Deschamps G, Garotta L, Dejour H (1999) Laxity in posterior sparing and posterior stabilized total knee prostheses. Clin Orthop 364:182–193PubMedCrossRef Dejour D, Deschamps G, Garotta L, Dejour H (1999) Laxity in posterior sparing and posterior stabilized total knee prostheses. Clin Orthop 364:182–193PubMedCrossRef
8.
Zurück zum Zitat Didurch DR, Insall JN, Scott WN, Scuderi GR, Font-Rodriguez D (1997) Total knee replacement in young, active patients. Long-term follow-up and functional outcome. J Bone Joint Surg [Am] 79-A:575–582 Didurch DR, Insall JN, Scott WN, Scuderi GR, Font-Rodriguez D (1997) Total knee replacement in young, active patients. Long-term follow-up and functional outcome. J Bone Joint Surg [Am] 79-A:575–582
9.
Zurück zum Zitat Engh GA, Parks NL, Ammeen DJ (1994) Tibial osteolysis in cementless total knee arthroplasty. Clin Orthop 309:33PubMed Engh GA, Parks NL, Ammeen DJ (1994) Tibial osteolysis in cementless total knee arthroplasty. Clin Orthop 309:33PubMed
10.
Zurück zum Zitat Fehring TK, Valadie AL (1993) Knee instability after total knee arthroplasty. Clin Orthop 299:157–162 Fehring TK, Valadie AL (1993) Knee instability after total knee arthroplasty. Clin Orthop 299:157–162
11.
Zurück zum Zitat Font-Rondriguez DE, Insall JN (1997) Survivorship of cemented total knee arthroplasty. Clin Orthop 343:79–86 Font-Rondriguez DE, Insall JN (1997) Survivorship of cemented total knee arthroplasty. Clin Orthop 343:79–86
12.
Zurück zum Zitat Furnes O, Espehaug B, Lie SA, Vollset SE, Engesaeter LB, Havelin LI (2002) Early failures among 7,174 primary total knee replacements: a follow-up study from the Norwegian Arthroplasty Register 1994–2000. Acta Orthop Scand 73(2):117–129PubMedCrossRef Furnes O, Espehaug B, Lie SA, Vollset SE, Engesaeter LB, Havelin LI (2002) Early failures among 7,174 primary total knee replacements: a follow-up study from the Norwegian Arthroplasty Register 1994–2000. Acta Orthop Scand 73(2):117–129PubMedCrossRef
13.
Zurück zum Zitat Garino JP, Lotke PA (1994) Sacrificing the posterior cruciate ligament with and without substitution in total knee arthroplasty. In: Fu F (ed) Knee surgery. Williams and Wilkins, Baltimore, pp 1313–1320 Garino JP, Lotke PA (1994) Sacrificing the posterior cruciate ligament with and without substitution in total knee arthroplasty. In: Fu F (ed) Knee surgery. Williams and Wilkins, Baltimore, pp 1313–1320
14.
Zurück zum Zitat Goodfellow J, O’Connor J (1978) The mechanics of the knee and prosthesis design. J Bone Joint Surg 60B(3):358–369 Goodfellow J, O’Connor J (1978) The mechanics of the knee and prosthesis design. J Bone Joint Surg 60B(3):358–369
15.
Zurück zum Zitat Hirsch HS, Lotke PA, Morrison CD (1994) The PCL in total knee surgery: save, sacrifice or substitute? Clin Orthop 309:64–68PubMed Hirsch HS, Lotke PA, Morrison CD (1994) The PCL in total knee surgery: save, sacrifice or substitute? Clin Orthop 309:64–68PubMed
16.
Zurück zum Zitat Hofmann AA, Tkach TK, Evanich CJ, Camargo MP (2000) Posterior stabilization in total knee arthroplasty with use of an ultracongruent polyethylene insert. J Arthroplasty 15(5):576–583PubMedCrossRef Hofmann AA, Tkach TK, Evanich CJ, Camargo MP (2000) Posterior stabilization in total knee arthroplasty with use of an ultracongruent polyethylene insert. J Arthroplasty 15(5):576–583PubMedCrossRef
17.
Zurück zum Zitat Huang CH, Ma HM, Liau JJ, Ho FY, Cheng CK (2002) Late dislocation of rotating platform in New Jersey Low-Contact Stress Knee Prosthesis. Clin Orthop 405:189–194PubMedCrossRef Huang CH, Ma HM, Liau JJ, Ho FY, Cheng CK (2002) Late dislocation of rotating platform in New Jersey Low-Contact Stress Knee Prosthesis. Clin Orthop 405:189–194PubMedCrossRef
18.
Zurück zum Zitat Insall J, Lachiewicz P, Burstein A (1982) The posterior stabilized condylar prosthesis: a modification of the total condylar design. J Bone Joint Surg 64A:1317–1323 Insall J, Lachiewicz P, Burstein A (1982) The posterior stabilized condylar prosthesis: a modification of the total condylar design. J Bone Joint Surg 64A:1317–1323
19.
Zurück zum Zitat Laskin RS, Maruyama Y et al (2000) Deep-dish congruent tibial component use in total knee arthroplasty: a randomised prospective study. Clin Orthop 380:36–44PubMedCrossRef Laskin RS, Maruyama Y et al (2000) Deep-dish congruent tibial component use in total knee arthroplasty: a randomised prospective study. Clin Orthop 380:36–44PubMedCrossRef
20.
Zurück zum Zitat Lewis P, Rorabeck CH, Bourne RB et al (1994) Posteromedial tibial polyethylene failure in total knee replacement. Clin Orthop 299:11PubMed Lewis P, Rorabeck CH, Bourne RB et al (1994) Posteromedial tibial polyethylene failure in total knee replacement. Clin Orthop 299:11PubMed
21.
Zurück zum Zitat Li PL, Zamora J, Bentley G (1999) The results at ten years of the Insall-Burstein II total knee replacement. Clinical, radiological and survivership studies. J Bone Joint Surg Br 81:647–653PubMedCrossRef Li PL, Zamora J, Bentley G (1999) The results at ten years of the Insall-Burstein II total knee replacement. Clinical, radiological and survivership studies. J Bone Joint Surg Br 81:647–653PubMedCrossRef
22.
Zurück zum Zitat Lombardi A, Mallory T, Waterman R, Eberle R (1995) Intercondylar distal femoral fracture. J Arthroplasty 10:643–650PubMedCrossRef Lombardi A, Mallory T, Waterman R, Eberle R (1995) Intercondylar distal femoral fracture. J Arthroplasty 10:643–650PubMedCrossRef
23.
Zurück zum Zitat Mikulak SA, Mahoney OM, dela Rosa MA, Schmalzried TP (2001) Loosening and osteolysis with the press-fit condylar posterior cruciate-substituting total knee replacement. J Bone Joint Surg Am 83:398–403PubMed Mikulak SA, Mahoney OM, dela Rosa MA, Schmalzried TP (2001) Loosening and osteolysis with the press-fit condylar posterior cruciate-substituting total knee replacement. J Bone Joint Surg Am 83:398–403PubMed
24.
Zurück zum Zitat Misra AN, Hussain MRA, Fiddian NJ, Newton G (2002) The role of posterior cruciate ligament in total knee replacement. J Bone Joint Surg Br 85-B(3):389–392 Misra AN, Hussain MRA, Fiddian NJ, Newton G (2002) The role of posterior cruciate ligament in total knee replacement. J Bone Joint Surg Br 85-B(3):389–392
25.
Zurück zum Zitat Noyes FR, Stowers SF, Grood ES, Cummings J, VanGinkel LA (1993) Posterior subluxations of the medial and lateral tibiofemoral compartments. An in vitro ligament sectioning study in cadaveric knees. Am J Sports Med 21(3):407–414PubMedCrossRef Noyes FR, Stowers SF, Grood ES, Cummings J, VanGinkel LA (1993) Posterior subluxations of the medial and lateral tibiofemoral compartments. An in vitro ligament sectioning study in cadaveric knees. Am J Sports Med 21(3):407–414PubMedCrossRef
26.
Zurück zum Zitat Puloski SK, McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB (2001) Tibial post wear in posterior stabilized total knee arthroplasty.An unrecognized source of polyethylene debris. J Bone Joint Surg Am 83:390–397PubMed Puloski SK, McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB (2001) Tibial post wear in posterior stabilized total knee arthroplasty.An unrecognized source of polyethylene debris. J Bone Joint Surg Am 83:390–397PubMed
27.
Zurück zum Zitat Rand JA, Trousdale RT, Ilstrup D, Harmsen S (2003) Factors affecting the durability of primary total knee prosthesis. J Bone Joint Surg Am 85(2):259–268PubMed Rand JA, Trousdale RT, Ilstrup D, Harmsen S (2003) Factors affecting the durability of primary total knee prosthesis. J Bone Joint Surg Am 85(2):259–268PubMed
28.
Zurück zum Zitat Robertsson O, Dunbar M, Pehrsson T, Knutson K, Lidgren L (2000) Patient satisfaction after knee arthroplasty: a report on 27372 knees operated on between 1981 and 1995 in Sweden. Acta Orthop Scand 71:262–267PubMedCrossRef Robertsson O, Dunbar M, Pehrsson T, Knutson K, Lidgren L (2000) Patient satisfaction after knee arthroplasty: a report on 27372 knees operated on between 1981 and 1995 in Sweden. Acta Orthop Scand 71:262–267PubMedCrossRef
29.
Zurück zum Zitat Robinson EJ, Mulliken BD, Bourne RD et al (1995) Catastrophic osteolysis in total knee replacement: a report of 17 cases. Clin Orthop 321:98PubMed Robinson EJ, Mulliken BD, Bourne RD et al (1995) Catastrophic osteolysis in total knee replacement: a report of 17 cases. Clin Orthop 321:98PubMed
30.
Zurück zum Zitat Scott R, Thornhill T (1994) Posterior cruciate supplementing total knee replacement using conforming inserts and cruciate recession. Clin Orthop 205:146–149 Scott R, Thornhill T (1994) Posterior cruciate supplementing total knee replacement using conforming inserts and cruciate recession. Clin Orthop 205:146–149
31.
Zurück zum Zitat Walker PS, Wang CJ, Masse Y (2003) Joint laxity as a criterion for the design of condylar knee prostheses 1974. Clin Orthop Relat Res 410:5–12PubMedCrossRef Walker PS, Wang CJ, Masse Y (2003) Joint laxity as a criterion for the design of condylar knee prostheses 1974. Clin Orthop Relat Res 410:5–12PubMedCrossRef
32.
Zurück zum Zitat White SH, O’Connor JJ, Goodfellow JW (1991) Sagital plane laxity following knee arthroplasty. J Bone Joint Surg 73-B:268–270 White SH, O’Connor JJ, Goodfellow JW (1991) Sagital plane laxity following knee arthroplasty. J Bone Joint Surg 73-B:268–270
33.
Zurück zum Zitat Wright TM, Rimnac CM, Stulberg SD, Mintz L, Tsao AK, Klein RW, McCrae C (1992) Wear of polyethylene in total joint replacement. Clin Orthop 276:126–134PubMed Wright TM, Rimnac CM, Stulberg SD, Mintz L, Tsao AK, Klein RW, McCrae C (1992) Wear of polyethylene in total joint replacement. Clin Orthop 276:126–134PubMed
Metadaten
Titel
Posterior stability in fixed-bearing versus mobile-bearing total knee replacement: a radiological comparison of two implants
verfasst von
R. Siebold
S. Louisia
J. Canty
R. J. Bartlett
Publikationsdatum
01.02.2007
Verlag
Springer-Verlag
Erschienen in
Archives of Orthopaedic and Trauma Surgery / Ausgabe 2/2007
Print ISSN: 0936-8051
Elektronische ISSN: 1434-3916
DOI
https://doi.org/10.1007/s00402-006-0232-4

Weitere Artikel der Ausgabe 2/2007

Archives of Orthopaedic and Trauma Surgery 2/2007 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

TEP mit Roboterhilfe führt nicht zu größerer Zufriedenheit

15.05.2024 Knie-TEP Nachrichten

Der Einsatz von Operationsrobotern für den Einbau von Totalendoprothesen des Kniegelenks hat die Präzision der Eingriffe erhöht. Für die postoperative Zufriedenheit der Patienten scheint das aber unerheblich zu sein, wie eine Studie zeigt.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.