Skip to main content
Erschienen in: Intensive Care Medicine 8/2010

01.08.2010 | Original

Small dead space heat and moisture exchangers do not impede gas exchange during noninvasive ventilation: a comparison with a heated humidifier

verfasst von: Alexandre Boyer, Frederic Vargas, Gilles Hilbert, Didier Gruson, Maud Mousset-Hovaere, Yves Castaing, Didier Dreyfuss, Jean Damien Ricard

Erschienen in: Intensive Care Medicine | Ausgabe 8/2010

Einloggen, um Zugang zu erhalten

Abstract

Objective

Adverse respiratory and gasometrical effects have been described in patients with acute respiratory failure (ARF) undergoing noninvasive ventilation (NIV) with standard heat and moisture exchangers (HME). We decided to evaluate respiratory parameters and arterial blood gases (ABG) of patients during NIV with small dead space HME compared with heated humidifier (HH).

Design

Prospective randomized crossover study.

Setting

A 16-bed medical intensive care unit (ICU).

Patients

Fifty patients receiving NIV for ARF.

Measurements

The effects of HME and HH on respiratory rate, minute ventilation, EtCO2, oxygen saturation, airway occlusion pressure at 0.1 s, ABG, and comfort perception were compared during two randomly determined NIV periods of 30 min. The relative impact of HME and HH on these parameters was successively compared with or without addition of a flex tube (40 and 10 patients, respectively).

Main results

No difference was observed between HME and HH regarding any of the studied parameters, whether or not a flex tube was added.

Conclusion

If one decides to humidify patients’ airways during NIV, one may do so with small dead space HME or HH without altering respiratory parameters.
Literatur
1.
Zurück zum Zitat Ricard J-D (2006) Humidification. In: Tobin M (ed) Principles and practice of mechanical ventilation. McGraw-Hill, New York, pp 1109–1120 Ricard J-D (2006) Humidification. In: Tobin M (ed) Principles and practice of mechanical ventilation. McGraw-Hill, New York, pp 1109–1120
2.
Zurück zum Zitat No author (2001) International consensus conferences in intensive care medicine: noninvasive positive pressure ventilation in acute respiratory failure. Am J Respir Crit Care Med 163:283–291 No author (2001) International consensus conferences in intensive care medicine: noninvasive positive pressure ventilation in acute respiratory failure. Am J Respir Crit Care Med 163:283–291
3.
Zurück zum Zitat Chanques G, Jaber S, Delay J, Perrigault PF, Lefrance J, Eledjam JJ (2003) Phoning study about postoperative practice and application of non-invasive ventilation. Ann Fr Anesth Reanim 22:879–885PubMed Chanques G, Jaber S, Delay J, Perrigault PF, Lefrance J, Eledjam JJ (2003) Phoning study about postoperative practice and application of non-invasive ventilation. Ann Fr Anesth Reanim 22:879–885PubMed
4.
Zurück zum Zitat Le Bourdelles G, Mier L, Fiquet B, Djedaini K, Saumon G, Coste F, Dreyfuss D (1996) Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation. Chest 110:1294–1298CrossRefPubMed Le Bourdelles G, Mier L, Fiquet B, Djedaini K, Saumon G, Coste F, Dreyfuss D (1996) Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during weaning trials from mechanical ventilation. Chest 110:1294–1298CrossRefPubMed
5.
Zurück zum Zitat Pelosi P, Solca M, Ravagnan I, Tubiolo D, Ferrario L, Gattinoni L (1996) Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure. Crit Care Med 24:1184–1188CrossRefPubMed Pelosi P, Solca M, Ravagnan I, Tubiolo D, Ferrario L, Gattinoni L (1996) Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure. Crit Care Med 24:1184–1188CrossRefPubMed
6.
Zurück zum Zitat Girault C, Breton L, Richard JC, Tamion F, Vandelet P, Aboab J, Leroy J, Bonmarchand G (2003) Mechanical effects of airway humidification devices in difficult to wean patients. Crit Care Med 31:1306–1311CrossRefPubMed Girault C, Breton L, Richard JC, Tamion F, Vandelet P, Aboab J, Leroy J, Bonmarchand G (2003) Mechanical effects of airway humidification devices in difficult to wean patients. Crit Care Med 31:1306–1311CrossRefPubMed
7.
Zurück zum Zitat Branson RD, Davis KJ (1996) Evaluation of 21 passive humidifiers according to the ISO 9360 standard: moisture output, dead space, and flow resistance. Respir Care 41:736–743 Branson RD, Davis KJ (1996) Evaluation of 21 passive humidifiers according to the ISO 9360 standard: moisture output, dead space, and flow resistance. Respir Care 41:736–743
8.
Zurück zum Zitat Lellouche F, Maggiore SM, Deye N, Taille S, Pigeot J, Harf A, Brochard L (2002) Effect of the humidification device on the work of breathing during noninvasive ventilation. Intensive Care Med 28:1582–1589CrossRefPubMed Lellouche F, Maggiore SM, Deye N, Taille S, Pigeot J, Harf A, Brochard L (2002) Effect of the humidification device on the work of breathing during noninvasive ventilation. Intensive Care Med 28:1582–1589CrossRefPubMed
9.
Zurück zum Zitat Jaber S, Chanques G, Matecki S, Ramonatxo M, Souche B, Perrigault PF, Eledjam JJ (2002) Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during non-invasive ventilation. Intensive Care Med 28:1590–1594CrossRefPubMed Jaber S, Chanques G, Matecki S, Ramonatxo M, Souche B, Perrigault PF, Eledjam JJ (2002) Comparison of the effects of heat and moisture exchangers and heated humidifiers on ventilation and gas exchange during non-invasive ventilation. Intensive Care Med 28:1590–1594CrossRefPubMed
10.
Zurück zum Zitat Demoule A, Girou E, Richard JC, Taille S, Brochard L (2006) Increased use of noninvasive ventilation in French intensive care units. Intensive Care Med 32:1747–1755CrossRefPubMed Demoule A, Girou E, Richard JC, Taille S, Brochard L (2006) Increased use of noninvasive ventilation in French intensive care units. Intensive Care Med 32:1747–1755CrossRefPubMed
11.
Zurück zum Zitat Brochard L, Isabey D, Piquet J, Amaro P, Mancebo J, Messadi AA, Brun-Buisson C, Rauss A, Lemaire F, Harf A (1990) Reversal of acute exacerbations of chronic obstructive lung disease by inspiratory assistance with a face mask. N Engl J Med 323:1523–1530PubMedCrossRef Brochard L, Isabey D, Piquet J, Amaro P, Mancebo J, Messadi AA, Brun-Buisson C, Rauss A, Lemaire F, Harf A (1990) Reversal of acute exacerbations of chronic obstructive lung disease by inspiratory assistance with a face mask. N Engl J Med 323:1523–1530PubMedCrossRef
12.
Zurück zum Zitat Brochard L, Mancebo J, Wysocki M, Lofaso F, Conti G, Rauss A, Simonneau G, Benito S, Gasparetto A, Lemaire F et al (1995) Noninvasive ventilation for acute exacerbations of chronic obstructive pulmonary disease. N Engl J Med 333:817–822CrossRefPubMed Brochard L, Mancebo J, Wysocki M, Lofaso F, Conti G, Rauss A, Simonneau G, Benito S, Gasparetto A, Lemaire F et al (1995) Noninvasive ventilation for acute exacerbations of chronic obstructive pulmonary disease. N Engl J Med 333:817–822CrossRefPubMed
13.
Zurück zum Zitat Boyer A, Thiery G, Lasry S, Pigné E, Salah A, de Lassence A, Dreyfuss D, Ricard J-D (2003) Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective, clinical, hygrometric and bacteriologic study. Crit Care Med 31:823–829CrossRefPubMed Boyer A, Thiery G, Lasry S, Pigné E, Salah A, de Lassence A, Dreyfuss D, Ricard J-D (2003) Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective, clinical, hygrometric and bacteriologic study. Crit Care Med 31:823–829CrossRefPubMed
14.
Zurück zum Zitat Lellouche F, Maggiore SM, Lyazidi A, Deye N, Taille S, Brochard L (2009) Water content of delivered gases during non-invasive ventilation in healthy subjects. Intensive Care Med 35:987–995CrossRefPubMed Lellouche F, Maggiore SM, Lyazidi A, Deye N, Taille S, Brochard L (2009) Water content of delivered gases during non-invasive ventilation in healthy subjects. Intensive Care Med 35:987–995CrossRefPubMed
15.
Zurück zum Zitat Alberti A, Gallo F, Fongaro A, Valenti S, Rossi A (1995) P0.1 is a useful parameter in setting the level of pressure support ventilation. Intensive Care Med 21:547–553CrossRefPubMed Alberti A, Gallo F, Fongaro A, Valenti S, Rossi A (1995) P0.1 is a useful parameter in setting the level of pressure support ventilation. Intensive Care Med 21:547–553CrossRefPubMed
16.
Zurück zum Zitat Berger KI, Sorkin IB, Norman RG, Rapoport DM, Goldring RM (1996) Mechanism of relief of tachypnea during pressure support ventilation. Chest 109:1320–1327CrossRefPubMed Berger KI, Sorkin IB, Norman RG, Rapoport DM, Goldring RM (1996) Mechanism of relief of tachypnea during pressure support ventilation. Chest 109:1320–1327CrossRefPubMed
17.
Zurück zum Zitat Mancebo J, Albaladejo P, Touchard D, Bak E, Subirana M, Lemaire F, Harf A, Brochard L (2000) Airway occlusion pressure to titrate positive end-expiratory pressure in patients with dynamic hyperinflation. Anesthesiology 93:81–90CrossRefPubMed Mancebo J, Albaladejo P, Touchard D, Bak E, Subirana M, Lemaire F, Harf A, Brochard L (2000) Airway occlusion pressure to titrate positive end-expiratory pressure in patients with dynamic hyperinflation. Anesthesiology 93:81–90CrossRefPubMed
18.
Zurück zum Zitat Lellouche F, L’Her E, Abrouk F, Deye N, Rabbat A, Jaber S, Fartoukh M, Brochard L (2005) Impact of the humidifying device on intubation rate during NIV: results of a multicenter RCT. Intensive Care Med 31:S266 (abstract) Lellouche F, L’Her E, Abrouk F, Deye N, Rabbat A, Jaber S, Fartoukh M, Brochard L (2005) Impact of the humidifying device on intubation rate during NIV: results of a multicenter RCT. Intensive Care Med 31:S266 (abstract)
19.
Zurück zum Zitat Ricard JD, Boyer A (2009) Humidification during oxygen therapy and non-invasive ventilation: do we need some and how much? Intensive Care Med 35:963–965CrossRefPubMed Ricard JD, Boyer A (2009) Humidification during oxygen therapy and non-invasive ventilation: do we need some and how much? Intensive Care Med 35:963–965CrossRefPubMed
Metadaten
Titel
Small dead space heat and moisture exchangers do not impede gas exchange during noninvasive ventilation: a comparison with a heated humidifier
verfasst von
Alexandre Boyer
Frederic Vargas
Gilles Hilbert
Didier Gruson
Maud Mousset-Hovaere
Yves Castaing
Didier Dreyfuss
Jean Damien Ricard
Publikationsdatum
01.08.2010
Verlag
Springer-Verlag
Erschienen in
Intensive Care Medicine / Ausgabe 8/2010
Print ISSN: 0342-4642
Elektronische ISSN: 1432-1238
DOI
https://doi.org/10.1007/s00134-010-1894-5

Weitere Artikel der Ausgabe 8/2010

Intensive Care Medicine 8/2010 Zur Ausgabe

Mehr Frauen im OP – weniger postoperative Komplikationen

21.05.2024 Allgemeine Chirurgie Nachrichten

Ein Frauenanteil von mindestens einem Drittel im ärztlichen Op.-Team war in einer großen retrospektiven Studie aus Kanada mit einer signifikanten Reduktion der postoperativen Morbidität assoziiert.

„Übersichtlicher Wegweiser“: Lauterbachs umstrittener Klinik-Atlas ist online

17.05.2024 Klinik aktuell Nachrichten

Sie sei „ethisch geboten“, meint Gesundheitsminister Karl Lauterbach: mehr Transparenz über die Qualität von Klinikbehandlungen. Um sie abzubilden, lässt er gegen den Widerstand vieler Länder einen virtuellen Klinik-Atlas freischalten.

Delir bei kritisch Kranken – Antipsychotika versus Placebo

16.05.2024 Delir Nachrichten

Um die Langzeitfolgen eines Delirs bei kritisch Kranken zu mildern, wird vielerorts auf eine Akuttherapie mit Antipsychotika gesetzt. Eine US-amerikanische Forschungsgruppe äußert jetzt erhebliche Vorbehalte gegen dieses Vorgehen. Denn es gibt neue Daten zum Langzeiteffekt von Haloperidol bzw. Ziprasidon versus Placebo.

Klinikreform soll zehntausende Menschenleben retten

15.05.2024 Klinik aktuell Nachrichten

Gesundheitsminister Lauterbach hat die vom Bundeskabinett beschlossene Klinikreform verteidigt. Kritik an den Plänen kommt vom Marburger Bund. Und in den Ländern wird über den Gang zum Vermittlungsausschuss spekuliert.

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.