Skip to main content
Erschienen in: European Spine Journal 6/2009

01.06.2009 | Original Article

Treatment of pediatric atlantoaxial instability with traditional and modified Goel–Harms fusion constructs

verfasst von: Gregory G. Heuer, Douglas A. Hardesty, Deb A. Bhowmick, Robert Bailey, Suresh N. Magge, Phillip B. Storm

Erschienen in: European Spine Journal | Ausgabe 6/2009

Einloggen, um Zugang zu erhalten

Abstract

There are several treatment options for rigid fixation at C1–C2 including Brooks and Gallie type wired fusions and C1–2 transarticular screws. The use of a Goel–Harms type fusion, a construct with C1 lateral mass screws and C2 pedicle screws, has not been extensively described in pediatric patients. Here, we describe its relatively safe and effective use for treating pediatric patients by retrospective chart review of patients treated by the senior author for atlantoaxial instability with a Goel–Harms-type constructs during a 3-year period (2005–2007). Six patients were treated using Goel–Harms-type constructs. Five patients were treated utilizing a construct containing C1 lateral mass screws and C2 pedicle screws; one patient was treated using construct containing C1 lateral mass screws and C2 trans-laminar screws. The patients ranged in age from 7 to 17 years old (mean 12.7). All patients had findings of an os odontoideum on CT scans and three of the six patients had T2 hyperintensity on MRI. Three of the six patients presented with transient neurologic deficits: quadraplegia in two patients and paresthesias in two patients. In each patient C1 lateral mass and C2 screws were placed and the subluxation was reduced to attain an anatomical alignment. No bone grafts were harvested from the iliac crest or rib. Local morsalized bone and sub-occipital skull graft was used. All patients tolerated the procedure well and were discharged home on post-operative day 3–4. The patients wore a hard cervical collar and no halo-vests were needed. All patients had solid fusion constructs and normal alignment on post-operative imaging studies performed on average 14 months post-operatively (range: 7–29). The results demonstrated that Goel–Harms fusions are a relatively safe and effective method of treating pediatric patients with atlantoaxial instability and are not dependent on vertebral anatomy or an intact ring of C1. Follow-up visits and studies in this limited series of patients demonstrated solid fusion constructs and anatomical alignment in all patients treated.
Literatur
1.
Zurück zum Zitat Anderson RC, Kan P, Gluf WM, Brockmeyer DL (2006) Long-term maintenance of cervical alignment after occipitocervical and atlantoaxial screw fixation in young children. J Neurosurg 105:55–61PubMed Anderson RC, Kan P, Gluf WM, Brockmeyer DL (2006) Long-term maintenance of cervical alignment after occipitocervical and atlantoaxial screw fixation in young children. J Neurosurg 105:55–61PubMed
2.
Zurück zum Zitat Anderson RCE, Ragel BT, Bohman LE, Brockmeyer DL (2007) Selection of a rigid internal fixation construct for stabilization at the craniovertebral junction in pediatric patients. J Neurosurg 107:36–42PubMed Anderson RCE, Ragel BT, Bohman LE, Brockmeyer DL (2007) Selection of a rigid internal fixation construct for stabilization at the craniovertebral junction in pediatric patients. J Neurosurg 107:36–42PubMed
5.
Zurück zum Zitat Brockmeyer DL, Apfelbaum RI (1999) A new occipitocervical fusion construct in pediatric patients with occipitocervical instability. Technical note. J Neurosurg 90:271–275PubMed Brockmeyer DL, Apfelbaum RI (1999) A new occipitocervical fusion construct in pediatric patients with occipitocervical instability. Technical note. J Neurosurg 90:271–275PubMed
6.
Zurück zum Zitat Brockmeyer DL, York JE, Apfelbaum RI (2000) Anatomical suitability of C1–2 transarticular screw placement in pediatric patients. J Neurosurg 92:7–11PubMedCrossRef Brockmeyer DL, York JE, Apfelbaum RI (2000) Anatomical suitability of C1–2 transarticular screw placement in pediatric patients. J Neurosurg 92:7–11PubMedCrossRef
7.
Zurück zum Zitat Brockmeyer DL (2002) A bone and cable girth-hitch technique for atlantoaxial fusion in pediatric patients. Technical note. J Neurosurg 97:400–402PubMed Brockmeyer DL (2002) A bone and cable girth-hitch technique for atlantoaxial fusion in pediatric patients. Technical note. J Neurosurg 97:400–402PubMed
8.
Zurück zum Zitat Brooks AL, Jenkins EB (1978) Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am 60:279–284PubMed Brooks AL, Jenkins EB (1978) Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am 60:279–284PubMed
9.
12.
Zurück zum Zitat Dalinka MK, Rosenbaum AE, Van Houten F (1972) Congenital absence of the posterior arch of the atlas. Radiology 103:581–583PubMed Dalinka MK, Rosenbaum AE, Van Houten F (1972) Congenital absence of the posterior arch of the atlas. Radiology 103:581–583PubMed
14.
Zurück zum Zitat Fraser AB, Sen C, Casden AM, Catalano PJ, Post KD (1994) Cervical transdural intramedullary migration of a sublaminar wire A complication of cervical fixation. Spine 19:456–459PubMedCrossRef Fraser AB, Sen C, Casden AM, Catalano PJ, Post KD (1994) Cervical transdural intramedullary migration of a sublaminar wire A complication of cervical fixation. Spine 19:456–459PubMedCrossRef
15.
Zurück zum Zitat Galindo MJ Jr, Francis WR (1983) Atlantal fracture in a child through congenital anterior and posterior arch defects. A case report. Clin Orthop Relat Res (178):220–222 Galindo MJ Jr, Francis WR (1983) Atlantal fracture in a child through congenital anterior and posterior arch defects. A case report. Clin Orthop Relat Res (178):220–222
18.
Zurück zum Zitat Gluf WM, Brockmeyer DL (2005) Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 67 pediatric patients. J Neurosurg Spine 2:164–169PubMedCrossRef Gluf WM, Brockmeyer DL (2005) Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 67 pediatric patients. J Neurosurg Spine 2:164–169PubMedCrossRef
19.
Zurück zum Zitat Gluf WM, Schmidt MH, Appelbaum RI (2005) Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patients. J Neurosurg Spine 2:155–163PubMedCrossRef Gluf WM, Schmidt MH, Appelbaum RI (2005) Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patients. J Neurosurg Spine 2:155–163PubMedCrossRef
22.
25.
Zurück zum Zitat Jea A, Taylor MD, Dirks PB, Kulkarni AV, Rutka JT, Drake JM (2007) Incorporation of C-1 lateral mass screws in occipitocervical and atlantoaxial fusions for children 8 years of age or younger. Technical note. J Neurosurg 107:178–183. doi:10.3171/JNS-07/07/0178 PubMedCrossRef Jea A, Taylor MD, Dirks PB, Kulkarni AV, Rutka JT, Drake JM (2007) Incorporation of C-1 lateral mass screws in occipitocervical and atlantoaxial fusions for children 8 years of age or younger. Technical note. J Neurosurg 107:178–183. doi:10.​3171/​JNS-07/​07/​0178 PubMedCrossRef
27.
Zurück zum Zitat Lapsiwala SB, Anderson PA, Oza A, Resnick DK (2006) Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 58:516–521PubMed Lapsiwala SB, Anderson PA, Oza A, Resnick DK (2006) Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 58:516–521PubMed
28.
Zurück zum Zitat Leonard J, Wright N (2006) Pediatric atlantoaxial fixation with bilateral, crossing C-2 translaminar screws. Technical note. J Neurosurg 104:59–63PubMed Leonard J, Wright N (2006) Pediatric atlantoaxial fixation with bilateral, crossing C-2 translaminar screws. Technical note. J Neurosurg 104:59–63PubMed
29.
Zurück zum Zitat Lowry DW, Pollack IF, Clyde B, Albright AL, Adelson PD (1997) Upper cervical spine fusion in the pediatric population. J Neurosurg 87:671–676PubMed Lowry DW, Pollack IF, Clyde B, Albright AL, Adelson PD (1997) Upper cervical spine fusion in the pediatric population. J Neurosurg 87:671–676PubMed
31.
Zurück zum Zitat Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA (1997) Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 86:961–968PubMedCrossRef Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA (1997) Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 86:961–968PubMedCrossRef
33.
Zurück zum Zitat Martich V, Ben-Ami T, Yousefzadeh DK, Roizen NJ (1992) Hypoplastic posterior arch of C-1 in children with Down syndrome: a double jeopardy. Radiology 183:125–128PubMed Martich V, Ben-Ami T, Yousefzadeh DK, Roizen NJ (1992) Hypoplastic posterior arch of C-1 in children with Down syndrome: a double jeopardy. Radiology 183:125–128PubMed
34.
Zurück zum Zitat McRae DL (1960) The significance of abnormalities of the cervical spine. Am J Roentgenol Radium Ther Nucl Med 84:15–17 McRae DL (1960) The significance of abnormalities of the cervical spine. Am J Roentgenol Radium Ther Nucl Med 84:15–17
37.
Zurück zum Zitat Paramore CG, Dickman CA, Sonntag VK (1996) The anatomical suitability of the C1–2 complex for transarticular screw fixation. J Neurosurg 85:221–224PubMed Paramore CG, Dickman CA, Sonntag VK (1996) The anatomical suitability of the C1–2 complex for transarticular screw fixation. J Neurosurg 85:221–224PubMed
42.
Zurück zum Zitat Smith MD, Kotzar G, Yoo J, Bohlman H (1993) A biomechanical analysis of atlantoaxial stabilization methods using a bovine model. C1/C2 fixation analysis. Clin Orthop Relat Res 290:285–295PubMed Smith MD, Kotzar G, Yoo J, Bohlman H (1993) A biomechanical analysis of atlantoaxial stabilization methods using a bovine model. C1/C2 fixation analysis. Clin Orthop Relat Res 290:285–295PubMed
Metadaten
Titel
Treatment of pediatric atlantoaxial instability with traditional and modified Goel–Harms fusion constructs
verfasst von
Gregory G. Heuer
Douglas A. Hardesty
Deb A. Bhowmick
Robert Bailey
Suresh N. Magge
Phillip B. Storm
Publikationsdatum
01.06.2009
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 6/2009
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-009-0969-x

Weitere Artikel der Ausgabe 6/2009

European Spine Journal 6/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Ein Drittel der jungen Ärztinnen und Ärzte erwägt abzuwandern

07.05.2024 Klinik aktuell Nachrichten

Extreme Arbeitsverdichtung und kaum Supervision: Dr. Andrea Martini, Sprecherin des Bündnisses Junge Ärztinnen und Ärzte (BJÄ) über den Frust des ärztlichen Nachwuchses und die Vorteile des Rucksack-Modells.

Aquatherapie bei Fibromyalgie wirksamer als Trockenübungen

03.05.2024 Fibromyalgiesyndrom Nachrichten

Bewegungs-, Dehnungs- und Entspannungsübungen im Wasser lindern die Beschwerden von Patientinnen mit Fibromyalgie besser als das Üben auf trockenem Land. Das geht aus einer spanisch-brasilianischen Vergleichsstudie hervor.

Endlich: Zi zeigt, mit welchen PVS Praxen zufrieden sind

IT für Ärzte Nachrichten

Darauf haben viele Praxen gewartet: Das Zi hat eine Liste von Praxisverwaltungssystemen veröffentlicht, die von Nutzern positiv bewertet werden. Eine gute Grundlage für wechselwillige Ärztinnen und Psychotherapeuten.

Proximale Humerusfraktur: Auch 100-Jährige operieren?

01.05.2024 DCK 2024 Kongressbericht

Mit dem demographischen Wandel versorgt auch die Chirurgie immer mehr betagte Menschen. Von Entwicklungen wie Fast-Track können auch ältere Menschen profitieren und bei proximaler Humerusfraktur können selbst manche 100-Jährige noch sicher operiert werden.

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.