Skip to main content
Erschienen in: Clinical Research in Cardiology 1/2016

01.01.2016 | Original Paper

Two-year outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon: lessons from the bonus freeze protocol

verfasst von: Andreas Metzner, Christian-Hendrik Heeger, Peter Wohlmuth, Bruno Reißmann, Andreas Rillig, Roland Richard Tilz, Shibu Mathew, Christine Lemes, Sebastian Deiß, Tilman Maurer, Ardan Saguner, Feifan Ouyang, Karl-Heinz Kuck, Erik Wißner

Erschienen in: Clinical Research in Cardiology | Ausgabe 1/2016

Einloggen, um Zugang zu erhalten

Abstract

Background

Pulmonary vein isolation (PVI) using the second-generation cryoballoon (CB2) in patients with paroxysmal and persistent atrial fibrillation (AF) has demonstrated encouraging acute and mid-term results. Follow-up data on outcome beyond 1-year is lacking. The purpose of this analysis was to investigate the 2-year clinical outcome after CB2-based PVI.

Methods

Sixty patients (age 62 ± 11 years) with paroxysmal [45/60 (75 %) patients] or short-standing persistent AF [15/60 (25 %) patients] underwent 28-mm CB2-based PVI. Freeze-cycle duration was 240 s. After successful PVI, a bonus freeze-cycle of the same duration was applied. Follow-up was based on outpatient clinic visits at 3, 6, 12, 18, and 24 months including 24 h Holter-ECGs and telephone interviews. Recurrence was defined as any symptomatic and/or documented atrial tachyarrhythmia (ATA) episode >30 s following a 3-month blanking period.

Results

A total of 231 pulmonary veins (PV) were identified and 230/231 (99.6 %) PVs were successfully isolated. Phrenic nerve palsy occurred in 2/60 (3.3 %) patients. No other periprocedural complications occurred. Follow-up was available for 59/60 (98 %) patients with a mean duration of 838 ± 67 days. A total of 43/59 (73 %) patients remained in stable sinus rhythm. In 10/16 (63 %) patients with ATA recurrence, a repeat procedure was performed using radiofrequency energy. The overall success rate after a maximum of two ablation procedures and a follow-up period of 838 ± 67 days was 88 % (52/59) patients.

Conclusions

Patients with paroxysmal or short-persistent AF undergoing PVI using the 28-mm CB2 demonstrated a 73 % 2-year single-procedure clinical success rate.
Literatur
1.
Zurück zum Zitat Su W, Kowal R, Kowalski M, Metzner A, Svinarich JT, Wheelan K, Wang P (2015) Best Practice Guide for Cryoballoon Ablation in Atrial Fibrillation: the compilation experience of over 3000 Procedures. Heart Rhythm. 12:1658–1666PubMedCrossRef Su W, Kowal R, Kowalski M, Metzner A, Svinarich JT, Wheelan K, Wang P (2015) Best Practice Guide for Cryoballoon Ablation in Atrial Fibrillation: the compilation experience of over 3000 Procedures. Heart Rhythm. 12:1658–1666PubMedCrossRef
2.
Zurück zum Zitat Metzner A, Reissmann B, Rausch P, Mathew S, Wohlmuth P, Tilz R, Rillig A, Lemes C, Deiss S, Heeger C et al (2014) One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon. Circul Arrhyth Electrophysiol 7:288–292CrossRef Metzner A, Reissmann B, Rausch P, Mathew S, Wohlmuth P, Tilz R, Rillig A, Lemes C, Deiss S, Heeger C et al (2014) One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon. Circul Arrhyth Electrophysiol 7:288–292CrossRef
3.
Zurück zum Zitat Wissner E, Heeger CH, Grahn H, Reissmann B, Wohlmuth P, Lemes C, Rausch P, Mathew S, Rillig A, Deiss S et al (2015) One-year clinical success of a ‘no-bonus’ freeze protocol using the second-generation 28 mm cryoballoon for pulmonary vein isolation. Europace (Epub ahead of print) Wissner E, Heeger CH, Grahn H, Reissmann B, Wohlmuth P, Lemes C, Rausch P, Mathew S, Rillig A, Deiss S et al (2015) One-year clinical success of a ‘no-bonus’ freeze protocol using the second-generation 28 mm cryoballoon for pulmonary vein isolation. Europace (Epub ahead of print)
4.
Zurück zum Zitat Furnkranz A, Bordignon S, Dugo D, Perotta L, Gunawardene M, Schulte-Hahn B, Nowak B, Schmidt B, Chun JK (2014) Improved 1-year clinical success rate of pulmonary vein isolation with the second-generation cryoballoon in patients with paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol 25:840–844PubMedCrossRef Furnkranz A, Bordignon S, Dugo D, Perotta L, Gunawardene M, Schulte-Hahn B, Nowak B, Schmidt B, Chun JK (2014) Improved 1-year clinical success rate of pulmonary vein isolation with the second-generation cryoballoon in patients with paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol 25:840–844PubMedCrossRef
5.
Zurück zum Zitat Chierchia GB, Di Giovanni G, Ciconte G, de Asmundis C, Conte G, Sieira-Moret J, Rodriguez-Manero M, Casado R, Baltogiannis G, Namdar M et al (2014) Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up. Europace. 16:639–644PubMedCrossRef Chierchia GB, Di Giovanni G, Ciconte G, de Asmundis C, Conte G, Sieira-Moret J, Rodriguez-Manero M, Casado R, Baltogiannis G, Namdar M et al (2014) Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up. Europace. 16:639–644PubMedCrossRef
6.
Zurück zum Zitat Ciconte G, de Asmundis C, Sieira J, Conte G, Di Giovanni G, Mugnai G, Saitoh Y, Baltogiannis G, Irfan G, Coutino-Moreno HE et al (2015) Single 3-minute freeze for second-generation cryoballoon ablation: one-year follow-up after pulmonary vein isolation. Heart Rhythm. 12:673–680PubMedCrossRef Ciconte G, de Asmundis C, Sieira J, Conte G, Di Giovanni G, Mugnai G, Saitoh Y, Baltogiannis G, Irfan G, Coutino-Moreno HE et al (2015) Single 3-minute freeze for second-generation cryoballoon ablation: one-year follow-up after pulmonary vein isolation. Heart Rhythm. 12:673–680PubMedCrossRef
7.
Zurück zum Zitat Ciconte G, Ottaviano L, de Asmundis C, Baltogiannis G, Conte G, Sieira J, Di Giovanni G, Saitoh Y, Irfan G, Mugnai G et al (2015) Pulmonary vein isolation as index procedure for persistent atrial fibrillation: one-year clinical outcome after ablation using the second-generation cryoballoon. Heart Rhythm. 12:60–66PubMedCrossRef Ciconte G, Ottaviano L, de Asmundis C, Baltogiannis G, Conte G, Sieira J, Di Giovanni G, Saitoh Y, Irfan G, Mugnai G et al (2015) Pulmonary vein isolation as index procedure for persistent atrial fibrillation: one-year clinical outcome after ablation using the second-generation cryoballoon. Heart Rhythm. 12:60–66PubMedCrossRef
8.
Zurück zum Zitat Ciconte G, Baltogiannis G, de Asmundis C, Sieira J, Conte G, Di Giovanni G, Saitoh Y, Irfan G, Mugnai G, Hunuk B et al (2015) Circumferential pulmonary vein isolation as index procedure for persistent atrial fibrillation: a comparison between radiofrequency catheter ablation and second-generation cryoballoon ablation. Europace. Europace. 17:559–565PubMedCrossRef Ciconte G, Baltogiannis G, de Asmundis C, Sieira J, Conte G, Di Giovanni G, Saitoh Y, Irfan G, Mugnai G, Hunuk B et al (2015) Circumferential pulmonary vein isolation as index procedure for persistent atrial fibrillation: a comparison between radiofrequency catheter ablation and second-generation cryoballoon ablation. Europace. Europace. 17:559–565PubMedCrossRef
9.
Zurück zum Zitat Lemes C, Wissner E, Lin T, Mathew S, Deiss S, Rillig A, Heeger C, Wohlmuth P, Reissmann B, Tilz R et al (2015) One-year clinical outcome after pulmonary vein isolation in persistent atrial fibrillation using the second-generation 28 mm cryoballoon: a retrospective analysis. Europace (Epub ahead of print) Lemes C, Wissner E, Lin T, Mathew S, Deiss S, Rillig A, Heeger C, Wohlmuth P, Reissmann B, Tilz R et al (2015) One-year clinical outcome after pulmonary vein isolation in persistent atrial fibrillation using the second-generation 28 mm cryoballoon: a retrospective analysis. Europace (Epub ahead of print)
10.
Zurück zum Zitat Reddy VY, Sediva L, Petru J, Skoda J, Chovanec M, Chitovova Z, P DIS, Rubin E, Dukkipati S, Neuzil P (2015) Durability of pulmonary vein isolation with cryoballoon ablation: results from the SUstained PV isolation with ARctic Front Advance (SUPIR) Study. J Cardiovasc Electrophysiol 26:493–500 Reddy VY, Sediva L, Petru J, Skoda J, Chovanec M, Chitovova Z, P DIS, Rubin E, Dukkipati S, Neuzil P (2015) Durability of pulmonary vein isolation with cryoballoon ablation: results from the SUstained PV isolation with ARctic Front Advance (SUPIR) Study. J Cardiovasc Electrophysiol 26:493–500
11.
Zurück zum Zitat Bordignon S, Furnkranz A, Perrotta L, Dugo D, Konstantinou A, Nowak B, Schulte-Hahn B, Schmidt B, Chun KR (2015) High rate of durable pulmonary vein isolation after second-generation cryoballoon ablation: analysis of repeat procedures. Europace Europace 17:725–731PubMedCrossRef Bordignon S, Furnkranz A, Perrotta L, Dugo D, Konstantinou A, Nowak B, Schulte-Hahn B, Schmidt B, Chun KR (2015) High rate of durable pulmonary vein isolation after second-generation cryoballoon ablation: analysis of repeat procedures. Europace Europace 17:725–731PubMedCrossRef
12.
Zurück zum Zitat Metzner A, Burchard A, Wohlmuth P, Rausch P, Bardyszewski A, Gienapp C, Tilz RR, Rillig A, Mathew S, Deiss S et al (2013) Increased incidence of esophageal thermal lesions using the second-generation 28-mm cryoballoon. Circul Arrhyth Electrophysiol 6:769–775CrossRef Metzner A, Burchard A, Wohlmuth P, Rausch P, Bardyszewski A, Gienapp C, Tilz RR, Rillig A, Mathew S, Deiss S et al (2013) Increased incidence of esophageal thermal lesions using the second-generation 28-mm cryoballoon. Circul Arrhyth Electrophysiol 6:769–775CrossRef
13.
Zurück zum Zitat Metzner A, Rausch P, Lemes C, Reissmann B, Bardyszewski A, Tilz R, Rillig A, Mathew S, Deiss S, Kamioka M et al (2014) The incidence of phrenic nerve injury during pulmonary vein isolation using the second-generation 28 mm cryoballoon. J Cardiovasc Electrophysiol 25:466–470PubMedCrossRef Metzner A, Rausch P, Lemes C, Reissmann B, Bardyszewski A, Tilz R, Rillig A, Mathew S, Deiss S, Kamioka M et al (2014) The incidence of phrenic nerve injury during pulmonary vein isolation using the second-generation 28 mm cryoballoon. J Cardiovasc Electrophysiol 25:466–470PubMedCrossRef
14.
Zurück zum Zitat Casado-Arroyo R, Chierchia GB, Conte G, Levinstein M, Sieira J, Rodriguez-Manero M, di Giovanni G, Baltogiannis Y, Wauters K, de Asmundis C et al (2013) Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: a comparison between the first- and second-generation balloon. Heart Rhythm. 10:1318–1324PubMedCrossRef Casado-Arroyo R, Chierchia GB, Conte G, Levinstein M, Sieira J, Rodriguez-Manero M, di Giovanni G, Baltogiannis Y, Wauters K, de Asmundis C et al (2013) Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: a comparison between the first- and second-generation balloon. Heart Rhythm. 10:1318–1324PubMedCrossRef
15.
Zurück zum Zitat Ouyang F, Tilz R, Chun J, Schmidt B, Wissner E, Zerm T, Neven K, Kokturk B, Konstantinidou M, Metzner A et al (2010) Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up. Circulation 122:2368–2377PubMedCrossRef Ouyang F, Tilz R, Chun J, Schmidt B, Wissner E, Zerm T, Neven K, Kokturk B, Konstantinidou M, Metzner A et al (2010) Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up. Circulation 122:2368–2377PubMedCrossRef
16.
Zurück zum Zitat Tilz RR, Chun KR, Schmidt B, Fuernkranz A, Wissner E, Koester I, Baensch D, Boczor S, Koektuerk B, Metzner A et al (2010) Catheter ablation of long-standing persistent atrial fibrillation: a lesson from circumferential pulmonary vein isolation. J Cardiovasc Electrophysiol 21:1085–1093PubMedCrossRef Tilz RR, Chun KR, Schmidt B, Fuernkranz A, Wissner E, Koester I, Baensch D, Boczor S, Koektuerk B, Metzner A et al (2010) Catheter ablation of long-standing persistent atrial fibrillation: a lesson from circumferential pulmonary vein isolation. J Cardiovasc Electrophysiol 21:1085–1093PubMedCrossRef
17.
Zurück zum Zitat Tilz RR, Rillig A, Thum AM, Arya A, Wohlmuth P, Metzner A, Mathew S, Yoshiga Y, Wissner E, Kuck KH et al (2012) Catheter ablation of long-standing persistent atrial fibrillation: 5-year outcomes of the Hamburg Sequential Ablation Strategy. J Am Coll Cardiol 60:1921–1929PubMedCrossRef Tilz RR, Rillig A, Thum AM, Arya A, Wohlmuth P, Metzner A, Mathew S, Yoshiga Y, Wissner E, Kuck KH et al (2012) Catheter ablation of long-standing persistent atrial fibrillation: 5-year outcomes of the Hamburg Sequential Ablation Strategy. J Am Coll Cardiol 60:1921–1929PubMedCrossRef
Metadaten
Titel
Two-year outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon: lessons from the bonus freeze protocol
verfasst von
Andreas Metzner
Christian-Hendrik Heeger
Peter Wohlmuth
Bruno Reißmann
Andreas Rillig
Roland Richard Tilz
Shibu Mathew
Christine Lemes
Sebastian Deiß
Tilman Maurer
Ardan Saguner
Feifan Ouyang
Karl-Heinz Kuck
Erik Wißner
Publikationsdatum
01.01.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Research in Cardiology / Ausgabe 1/2016
Print ISSN: 1861-0684
Elektronische ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-015-0890-8

Weitere Artikel der Ausgabe 1/2016

Clinical Research in Cardiology 1/2016 Zur Ausgabe

Screening-Mammografie offenbart erhöhtes Herz-Kreislauf-Risiko

26.04.2024 Mammografie Nachrichten

Routinemäßige Mammografien helfen, Brustkrebs frühzeitig zu erkennen. Anhand der Röntgenuntersuchung lassen sich aber auch kardiovaskuläre Risikopatientinnen identifizieren. Als zuverlässiger Anhaltspunkt gilt die Verkalkung der Brustarterien.

Niedriger diastolischer Blutdruck erhöht Risiko für schwere kardiovaskuläre Komplikationen

25.04.2024 Hypotonie Nachrichten

Wenn unter einer medikamentösen Hochdrucktherapie der diastolische Blutdruck in den Keller geht, steigt das Risiko für schwere kardiovaskuläre Ereignisse: Darauf deutet eine Sekundäranalyse der SPRINT-Studie hin.

Therapiestart mit Blutdrucksenkern erhöht Frakturrisiko

25.04.2024 Hypertonie Nachrichten

Beginnen ältere Männer im Pflegeheim eine Antihypertensiva-Therapie, dann ist die Frakturrate in den folgenden 30 Tagen mehr als verdoppelt. Besonders häufig stürzen Demenzkranke und Männer, die erstmals Blutdrucksenker nehmen. Dafür spricht eine Analyse unter US-Veteranen.

Adipositas-Medikament auch gegen Schlafapnoe wirksam

24.04.2024 Adipositas Nachrichten

Der als Antidiabetikum sowie zum Gewichtsmanagement zugelassene Wirkstoff Tirzepatid hat in Studien bei adipösen Patienten auch schlafbezogene Atmungsstörungen deutlich reduziert, informiert der Hersteller in einer Vorab-Meldung zum Studienausgang.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.